953 resultados para blood lactate concentration


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Several studies have tried to find countermeasures against musculoskeletal de-conditioning during bed-rest, but none of them yielded decisive results. We hypothesised that resistive vibration exercise (RVE) might be a suitable training modality. We have therefore carried out a bed-rest study to evaluate its feasibility and efficacy during 56 days of bed-rest. Twenty healthy male volunteers aged 24 to 43 years were recruited and, after medical check-ups, randomised to a non-exercising control (Ctrl) group or a group that performed RVE 11 times per week. Strict bed-rest was controlled by video surveillance. The diet was controlled. RVE was performed in supine position, with a static force component of about twice the body weight and a smaller dynamic force component. RVE comprised four different units (squats, heel raises, toe raises, kicks), each of which lasted 60 - 100 seconds. Pre and post exercise levels of lactate were measured once weekly. Body weight was measured daily on a bed scale. Pain questionnaires were obtained in regular intervals during and after the bed-rest. Vibration frequency was set to 19 Hz at the beginning and progressed to 25.9 Hz (SD 1.9) at the end of the study, suggesting that the dynamic force component increased by 90%. The maximum sustainable exercise time for squat exercise increased from 86 s (SD 21) on day 11 of the BR to 176 s (SD 73) on day 53 (p = 0.006). On the same days, post-exercise lactate levels increased from 6.9 mmol/l (SD2.3) to 9.2 mmol/l (SD 3.5, p = 0.01). On average, body weight was unchanged in both groups during bed-rest, but single individuals in both groups depicted significant weight changes ranging from -10% to + d10% (p < 0.001). Lower limb pain was more frequent during bed-rest in the RVE subjects than in Ctrl (p = 0.035). During early recovery, subjects of both groups suffered from muscle pain to a comparable extent, but foot pain was more common in Ctrl than in RVE (p = 0.013 for plantar pain, p = 0.074 for dorsal foot pain). Our results indicate that RVE is feasible twice daily during bed-rest in young healthy males, provided that one afternoon and one entire day per week are free. Exercise progression, mainly by progression of vibration frequency, yielded increases in maximum sustainable exercise time and blood lactate. In conclusion, RVE as performed in this study, appears to be safe.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Muscle glycogen inharmoniously regulates glycogen synthase activity, glucose uptake, and proximal insulin signaling. Am J Physiol Endocrinol Metab 290: E154-E162, 2006. First published August 23, 2005; doi:10.1152/ajpendo. 00330.2005.-Insulin-stimulated glucose uptake and incorporation of glucose into skeletal muscle glycogen contribute to physiological regulation of blood glucose concentration. In the present study, glucose handling and insulin signaling in isolated rat muscles with low glycogen (LG, 24-h fasting) and high glycogen (HG, refed for 24 h) content were compared with muscles with normal glycogen (NG, rats kept on their normal diet). In LG, basal and insulin-stimulated glycogen synthesis and glycogen synthase activation were higher and glycogen synthase phosphorylation (Ser645, Ser649, Ser653, Ser657) lower than in NG. GLUT4 expression, insulin-stimulated glucose uptake, and PKB phosphorylation were higher in LG than in NG, whereas insulin receptor tyrosyl phosphorylation, insulin receptor substrate-1-associated phosphatidylinositol 3-kinase activity, and GSK-3 phosphorylation were unchanged. Muscles with HG showed lower insulin-stimulated glycogen synthesis and glycogen synthase activation than NG despite similar dephosphorylation. Insulin signaling, glucose uptake, and GLUT4 expression were similar in HG and NG. This discordant regulation of glucose uptake and glycogen synthesis in HG resulted in higher insulin-stimulated glucose 6-phosphate concentration, higher glycolytic flux, and intracellular accumulation of nonphosphorylated 2-deoxyglucose. In conclusion, elevated glycogen synthase activation, glucose uptake, and GLUT4 expression enhance glycogen resynthesis in muscles with low glycogen. High glycogen concentration per se does not impair proximal insulin signaling or glucose uptake. Insulin resistance is observed at the level of glycogen synthase, and the reduced glycogen synthesis leads to increased levels of glucose 6-phosphate, glycolytic flux, and accumulation of nonphosphorylated 2-deoxyglucose.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Few studies have focused on the metabolic responses to alternating high- and low-intensity exercise and, specifically, compared these responses to those seen during constant-load exercise performed at the same average power output. This study compared muscle metabolic responses between two patterns of exercise during which the intensity was either constant and just below critical power (CP) or that oscillated above and below CP. Six trained males (mean +/- SD age 23.6 +/- 2.6 y) completed two 30-minute bouts of cycling (alternating and constant) at an average intensity equal to 90% of CR The intensity during alternating exercise varied between 158% CP and 73% CP. Biopsy samples from the vastus lateralis muscle were taken before (PRE), at the midpoint and end (POST) of exercise and analysed for glycogen, lactate, PCr and pH. Although these metabolic variables in muscle changed significantly during both patterns of exercise, there were no significant differences (p > 0.05) between constant and alternating exercise for glycogen (PRE: 418.8 +/- 85 vs. 444.3 +/- 70; POST: 220.5 +/- 59 vs. 259.5 +/- 126mmol.kg(-1) dw), lactate (PRE: 8.5 +/- 7.7 vs. 8.5 +/- 8.3; POST: 49.9 +/- 19.0 vs. 42.6 +/- 26.6 mmol.kg(-1)dw), phosphocreatine (PRE: 77.9 +/- 11.6 vs. 75.7 +/- 16.9; POST: 65.8 +/- 12.1 vs. 61.2 +/- 12.7mmol.kg(-1)dw) or pH (PRE: 6.99 +/- 0.12 vs. 6.99 +/- 0.08; POST: 6.86 +/- 0.13 vs. 6.85 +/- 0.06), respectively. There were also no significant differences in blood lactate responses to the two patterns of exercise. These data suggest that, when the average power output is similar, large variations in exercise intensity exert no significant effect on muscle metabolism.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

I was recently part of a small committee looking at higher qualifications in contact lens practice and the discussion turned to future technologies. There was mention of different materials and different applications of contact lenses. Drug delivery with contact lenses was discussed as this has been talked about in the literature for a while. The first paper I could find that talked about using contact lenses for drug delivery dates back over 40 years. There was a review paper in CLAE in 2008 that looked specifically at this too [1]. However, where are these products? Why are we not seeing them in the market place? Maybe the technology is not quite there yet, or maybe patents are prohibiting usage or maybe the market is not big enough to develop such products? We do have lenses on the market with slow release of lubricating agents but not therapeutic agents used for ocular or systemic conditions. Contact lenses with pathogen detectors may be part of our contact lens armoury of the future and again we can already see papers in the literature that have trialled this technology for glucose monitoring in diabetics or lactate concentration in the tear film. Future contact lenses may incorporate better optics based on aberration control and we see this starting to emerge with aspheric designs designed to minimise spherical aberration. Irregular corneas can be fitted with topography based designs and again this technology exists and is being used by some manufacturers in their designs already. Moreover, the topography based fitting of irregular corneas is certainly something we see a lot of today and CLAE has seen many articles related to this over the last decade or so. What about further into the future? Well one interesting area must the 3-dimensional contact lenses, or contact lenses with electronic devices built in that simulate a display screen. A little like the virtual display spectacles that are already sold by electronics companies. It does not take much of a stretch of the imagination to see a large electronic company taking this technology on and making it viable. Will we see people on the train watching movies on these electronic virtual reality contact lenses? I think we will, but when is harder to know.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: This work investigates how short-term changes in blood glucose concentration affect the refractive components of the diabetic eye in patients with long-term Type 1 and Type 2 diabetes. Methods: Blood glucose concentration, refractive error components (mean spherical equivalent MSE, J0, J45), central corneal thickness (CCT), anterior chamber depth (ACD), crystalline lens thickness (LT), axial length (AL) and ocular aberrations were monitored at two-hourly intervals over a 12-hour period in: 20 T1DM patients (mean age ± SD) 38±14 years, baseline HbA1c 8.6±1.9%; 21 T2DM patients (mean age ± SD) 56±11 years, HbA1c 7.5±1.8%; and in 20 control subjects (mean age ± SD) 49±23 years, HbA1c 5.5±0.5%. The refractive and biometric results were compared with the corresponding changes in blood glucose concentration. Results: Blood glucose concentration at different times was found to vary significantly within (p<0.0005) and between groups (p<0.0005). However, the refractive error components and ocular aberrations were not found to alter significantly over the day in either the diabetic patients or the control subjects (p>0.05). Minor changes of marginal statistical or optical significance were observed in some biometric parameters. Similarly there were some marginally significant differences between the baseline biometric parameters of well-controlled and poorly-controlled diabetic subjects. Conclusion: This work suggests that normal, short-term fluctuations (of up to about 6 mM/l on a timescale of a few hours) in the blood glucose levels of diabetics are not usually associated with acute changes in refractive error or ocular wavefront aberrations. It is therefore possible that factors other than refractive error fluctuations are sometimes responsible for the transient visual problems often reported by diabetic patients. © 2012 Huntjens et al.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Les procédures appliquées avant l’abattage des animaux influencent directement la qualité de la viande en modulant l’état physiologique des porcs; ainsi, l’augmentation de la température corporelle, les taux élevés de lactate sanguin et l’épuisement des réserves de glycogène entre autres, occasionnent la majorité des baisses de qualité. L’objectif de cette thèse était de valider des outils indicateurs de stress porcin pour les fermes et les abattoirs. Ceux-ci seraient appliqués à la surveillance du bien-être animal et à la prédiction de variation de qualité de la viande porcine au niveau commercial. Premierement, les résultats de la thèse ont permis de conclure qu’un des outils développés (analyseur portatif de lactate) mesure la variation du niveau de lactate sanguin associé à l’état physiologique des porcs dans la phase péri-mortem et aide à expliquer la variation de la qualité de la viande chez le porc à l’abattoir, en particulier dans les muscles du jambon. Deuxièmement, les résultats des audits du bien-être animal appliqués de la ferme à l’abattoir ont démontré que la qualité du système d’élevage à la ferme d’origine et les compétences du chauffeur de camion sont d’importants critères affectant la réponse comportementale des porcs à la manipulation avant l’abattage. Ces résultats ont également démontré que les conditions de logement à la ferme (la faible densité et l’enrichissement dans les enclos), le comportement des porcs en période pré-abattage (glissade), ainsi que les interventions du manipulateur (utilisation du bâton électrique) dans la zone d’étourdissement de l’abattoir affectent négativement la variation de la qualité de la viande. L’application des protocoles d’audits dans la filière porcine a également démontré que le respect des critères de bien-être animal fixés par un outil de vérification est primordiale et permet de contrôler les conditions de bien-être des porcs à chaque étape de la période pré-abattage, de produire une viande de qualité supérieure et de réduire les pertes. Les audits de bien-être animal sont donc un outil qui apporte des resultats très pertinents pour aider a éviter les variations de la qualité de la viande chez le porc. Troisièmement, la thermographie infrarouge s’est avéré être une technique prometteuse permettant d’évaluer la variation de température corporelle de l’animal pendant et après un stress physique, en particulier lorsque cette mesure est prise derrière les oreilles. En conclusion, les outils validés à travers cette thèse représentent des méthodologies non invasives et potentiellement complémentaires à d’autres approches d’évaluation de l’état physiologique et du bien-être animal par rapport au stress, permettant de réduire les pertes de qualité de viande (par exemple en utilisation conjointe avec le niveau de lactate sanguin et les indicateurs de stress comportemental, entre autres).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background. The pharmacokinetics and pharmacodynamics of lumefantrine, a component of the most widely used treatment for malaria, artemether-lumefantrine, has not been adequately characterized in young children. Methods. Capillary whole-blood lumefantrine concentration and treatment outcomes were determined in 105 Ugandan children, ages 6 months to 2 years, who were treated for 249 episodes of Plasmodium falciparum malaria with artemether-lumefantrine. Results. Population pharmacokinetics for lumefantrine used a 2-compartment open model with first-order absorption. Age had a significant positive correlation with bioavailability in a model that included allometric scaling. Children not receiving trimethoprim-sulfamethoxazole with capillary whole blood concentrations <200 ng/mL had a 3-fold higher hazard of 28-day recurrent parasitemia, compared with those with concentrations >200 ng/mL (P =. 0007). However, for children receiving trimethoprim-sulfamethoxazole, the risk of recurrent parasitemia did not differ significantly on the basis of this threshold. Day 3 concentrations were a stronger predictor of 28-day recurrence than day 7 concentrations. Conclusions. We demonstrate that age, in addition to weight, is a determinant of lumefantrine exposure, and in the absence of trimethoprim-sulfamethoxazole, lumefantrine exposure is a determinant of recurrent parasitemia. Exposure levels in children aged 6 months to 2 years was generally lower than levels published for older children and adults. Further refinement of artemether-lumefantrine dosing to improve exposure in infants and very young children may be warranted. © 2016 The Author.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this study was to investigate whether rinsing the mouth with a carbohydrate solution could improve skill-specific fencing performance and cognitive function following a fatigue inducing simulated bout of fencing in epee fencers. Eleven healthy, competitive epee fencers (three female; eight male; 33.9 ± 14.7 years; body mass 79 ± 16 kg; height 162 ± 54 cm) volunteered to participant in a single-blind crossover design study. During visit 1 participants completed a 1-minute lunge test and stroop test pre and post fatigue inducing fencing protocol. A 30 second electroencephalography (EEG) recording was taken pre-protocol participants were instructed stay in a seated stationary position with their eyes closed. Heart rate and ratings of perceived exertion were recorded following each fight during the fatiguing protocol. Participants mouth rinsed (10 seconds) either 25ml of a 6.7% maltodextrin solution (CHO) or 25ml of water (placebo) between fights and during the EEG recording. Blood lactate and glucose measurements were taken at baseline, pre and post protocol. All measurements and tests were repeated during a 2nd visit to the laboratory, except participants were given a different solution to mouth rinse, separated by a minimum of 5 days. The results showed an increase in heart rate (P < 0.05) and overall RPE (P < 0.001) over time in both trials. There were no recorded differences in blood glucose (F(1,8) = 0.634, P = 0.4, ηp 0.07) or blood lactate levels (F(1,8) = 0.123, P = 0.7, ηp 0.01) between trials. There was a significant improvement in lunge test accuracy in the CHO trial (F(1,8) = 5.214, P = 0.05, ηp 0.40). However, there was no recorded difference in response time to congruent (F(1,8) = 0.326, P = 0.58, ηp 0.04) or incongruent (F(1,8) = 0.189, P = 0.68, ηp 0.02) stimuli between trials. In conclusion mouth rinsing a CHO solution significantly improves accuracy of skill-specific fencing performance but does not affect cognitive function following a fatigue inducing fencing protocol in epee fencers.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study aimed to determine if ice slurry ingestion improved self-paced intermittent exercise in the heat. After a familiarisation session, 12 moderately trained males (30.4 ± 3.4 year, 1.8 ± 0.1 cm, 73.5 ± 14.3 kg, inline imageO2max 58.5 ± 8.1 mL/kg/min) completed two separate 31 min self-paced intermittent protocols on a non-motorised treadmill in 30.9 ± 0.9 °C, 41.1 ± 4.0% RH. Thirty minutes prior to exercise, participants consumed either 7.5 g/kg ice slurry (0.1 ± 0.1 °C) (ICE) or 7.5 g/kg water (23.4 ± 0.9 °C) (CONTROL). Despite reductions in Tc (ΔTc: −0.51 ± 0.3 °C, P < 0.05) and thermal sensation prior to exercise, ICE did not enhance self-paced intermittent exercise compared to CONTROL. The average speed during the walk (CONTROL: 5.90 ± 1.0 km, ICE: 5.90 ± 1.0 km), jog (CONTROL: 8.89 ± 1.7 km, ICE: 9.11 ± 1.5 km), run (CONTROL: 12.15 ± 1.7 km, ICE: 12.54 ± 1.5 km) and sprint (CONTROL: 17.32 ± 1.3 km, ICE: 17.18 ± 1.4 km) was similar between conditions (P > 0.05). Mean Tsk, Tb, blood lactate, heart rate and RPE were similar between conditions (P > 0.05). The findings suggest that lowering Tc prior to self-paced intermittent exercise does not translate into an improved performance.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study investigated the impact that mouth rinsing carbohydrate solution has on skill-specific performance and reaction time following a fatigue inducing bout of fencing in epee fencers. Nine healthy, national level epee fencers visited a laboratory on 2 occasions, separated by a minimum of 5 days, to complete a 1-minute lunge test and Stroop test pre and post fatigue. Heart rate and ratings of perceived exertion (RPE) were recorded during completion of the fatiguing protocol. Between fights the participants mouth rinsed for 10 seconds, either 25ml of 6.7% maltodextrin solution (MALT) or water (PLAC). Blood lactate and glucose were recorded at baseline, pre- and post-testing. Results showed an increase in heart rate and overall RPE over time in both conditions. There were no differences in blood glucose (F(1,8)=.63, P=.4, ηp=.07) or blood lactate levels (F(1,8)=.12, P=.70, ηp=.01) between conditions as a function of time. There was a significant improvement in lunge test accuracy during the MALT trial (F(1,8)=5.21, P=.05, ηp=.40) with an increase from pre (81.2 ±8.3%) to post (87.6 ±9.4%), whereas there was no significant change during the placebo (pre 82.1 ±8.8%, post 78.8 ±6.4%). There were no recorded differences between conditions in response time to congruent (F(1,8)=.33, P=.58, ηp=.04) or incongruent stimuli (F(1,8)=.19, P=.68, ηp=.02). The study indicates that when fatigued mouth rinsing MALT significantly improves accuracy of skill-specific fencing performance but no corresponding influence on reaction time was observed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Dissertação de Mestrado Integrado em Medicina Veterinária

Relevância:

80.00% 80.00%

Publicador:

Resumo:

No âmbito do Trabalho de Investigação Aplicada foi elaborada uma caracterização fisiológica do soldado nas operações em áreas edificadas, tendo como objetivo geral contribuir para o quadro teórico e prático na área da motricidade humana, relativamente às aptidões fisiológicas, designadamente: a Frequência Cardíaca, o Consumo de Oxigénio máximo (VO2max) e o Lactato Sanguíneo. Neste estudo foi executada uma pista de combate em áreas edificadas, com o nível de dificuldade crescente, inicialmente sem e com carga (colete balístico) de seguida com o inimigo armado com airsoft e para finalizar, a esquadra de assalto com armas de airsoft. A pista desenrolou-se na Aldeia de Camões em Mafra. Para medição dos parâmetros em estudo, utilizou os monitores cardíacos Garmin Forerunner 310XT, que fornecem os valores das Frequências Cardíacas e o Lactete Plus, que nos dão os valores dos níveis de Lactato Sanguíneo. Verificou-se que não existe uma doutrina de referência que evidencie o treino físico orientado para o combate em áreas edificadas nos dias de hoje. Da análise dos resultados obtidos verificámos que a intensidade do esforço, durante a execução das pistas de combate, foi predominantemente realizada no regime anaeróbio. Com os resultados alcançados durante a realização da pista de combate, identificámos algumas das tarefas mais críticas na sua execução. Apurámos através dos níveis de lactato que a função do comandante de esquadra é de uma intensidade de esforço físico superior a exigida na restante esquadra de assalto.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The present dissertation aimed to develop a new microfluidic system for a point-of-care hematocrit device. Stabilization of microfluidic systems via surfactant additives and integration of semipermeable SnakeSkin® membranes was investigated. Both methods stabilized the microfluidic systems by controlling electrolysis bubbles. Surfactant additives, Triton X-100 and SDS stabilized promoted faster bubble detachment at electrode surfaces by lowering surface tension and decreased gas bubble formation by increasing gas solubility. The SnakeSkin® membranes blocked bubbles from entering the microchannel and thus less disturbance to the electric field by bubbles occurred in the microchannel. Platinum electrode performance was improved by carbonizing electrode surface using red blood cells. Irreversibly adsorbed RBCs lysed on platinum electrode surfaces and formed porous carbon layers while current response measurements. The formed carbon layers increase the platinum electrode surface area and thus electrode performance was improved by 140 %. The microfluidic system was simplified by employing DC field to use as a platform for a point-of-care hematocrit device. Feasibility of the microfluidic system for hematocrit determination was shown via current response measurements of red blood cell suspensions in phosphate buffered saline and plasma media. The linear trendline of current responses over red blood cell concentration was obtained in both phosphate buffered saline and plasma media. This research suggested that a new and simple microfluidic system could be a promising solution to develop an inexpensive and reliable point-of-care hematocrit device.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

To investigate the validity and reliability of surface electromyography (EMG) as a new non-invasive determinant of the metabolic response to incremental exercise in elite cyclists. The relation between EMG activity and other more conventional methods for analysing the aerobic-anaerobic transition such as blood lactate measurements (lactate threshold (LT) and onset of blood lactate accumulation (OBLA)) and ventilatory parameters (ventilatory thresholds 1 and 2 (VT1 and VT2)) was studied.Twenty eight elite road cyclists (age 24 (4) years; VO2MAX 69.9 (6.4) ml/kg/min; values mean (SD)) were selected as subjects. Each of them performed a ramp protocol (starting at 0 W, with increases of 5 W every 12 seconds) on a cycle ergometer (validity study). In addition, 15 of them performed the same test twice (reliability study). During the tests, data on gas exchange and blood lactate levels were collected to determine VT1, VT2, LT, and OBLA. The root mean squares of EMG signals (rms-EMG) were recorded from both the vastus lateralis and the rectus femoris at each intensity using surface electrodes. Results - A two threshold response was detected in the rms-EMG recordings from both muscles in 90% of subjects, with two breakpoints, EMG(T1) and EMG(T2), at around 60-70% and 80-90% of VO2MAX respectively. The results of the reliability study showed no significant differences (p > 0.05) between mean values of EMG(T1) and EMG(T2) obtained in both tests. Furthermore, no significant differences (p > 0.05) existed between mean values of EMG(T1), in the vastus lateralis and rectus femoris, and VT1 and LT (62.8 (14.5) and 69.0 (6.2) and 64.6 (6.4) and 68.7 (8.2)% of VO2MAX respectively), or between mean values of EMG(T2), in the vastus lateralis and rectus femoris, and VT2 and OBLA (86.9 (9.0) and 88.0 (6.2) and 84.6 (6.5) and 87.7 (6.4)% of VO2MAX respectively). Rms-EMG may be a useful complementary non-invasive method for analysing the aerobic-anaerobic transition (ventilatory and lactate thresholds) in elite cyclists.