671 resultados para bipolar
Resumo:
In recent years, the network vulnerability to natural hazards has been noticed. Moreover, operating on the limits of the network transmission capabilities have resulted in major outages during the past decade. One of the reasons for operating on these limits is that the network has become outdated. Therefore, new technical solutions are studied that could provide more reliable and more energy efficient power distributionand also a better profitability for the network owner. It is the development and price of power electronics that have made the DC distribution an attractive alternative again. In this doctoral thesis, one type of a low-voltage DC distribution system is investigated. Morespecifically, it is studied which current technological solutions, used at the customer-end, could provide better power quality for the customer when compared with the current system. To study the effect of a DC network on the customer-end power quality, a bipolar DC network model is derived. The model can also be used to identify the supply parameters when the V/kW ratio is approximately known. Although the model provides knowledge of the average behavior, it is shown that the instantaneous DC voltage ripple should be limited. The guidelines to choose an appropriate capacitance value for the capacitor located at the input DC terminals of the customer-end are given. Also the structure of the customer-end is considered. A comparison between the most common solutions is made based on their cost, energy efficiency, and reliability. In the comparison, special attention is paid to the passive filtering solutions since the filter is considered a crucial element when the lifetime expenses are determined. It is found out that the filter topology most commonly used today, namely the LC filter, does not provide economical advantage over the hybrid filter structure. Finally, some of the typical control system solutions are introduced and their shortcomings are presented. As a solution to the customer-end voltage regulation problem, an observer-based control scheme is proposed. It is shown how different control system structures affect the performance. The performance meeting the requirements is achieved by using only one output measurement, when operating in a rigid network. Similar performance can be achieved in a weak grid by DC voltage measurement. An additional improvement can be achieved when an adaptive gain scheduling-based control is introduced. As a conclusion, the final power quality is determined by a sum of various factors, and the thesis provides the guidelines for designing the system that improves the power quality experienced by the customer.
Resumo:
During mitotic cell division, the genetic material packed into chromosomes is divided equally between two daughter cells. Before the separation of the two copies of a chromosome (sister chromatids), each chromosome has to be properly connected with microtubules of the mitotic spindle apparatus and aligned to the centre of the cell. The spindle assembly checkpoint (SAC) monitors connections between microtubules and chromosomes as well as tension applied across the centromere. Microtubules connect to a chromosome via kinetochores, which are proteinaceous organelles assembled onto the centromeric region of the sister chromatids. Improper kinetochore-microtubule attachments activate the SAC and block chromosome segregation until errors are corrected and all chromosomes are connected to the mitotic spindle in a bipolar manner. The purpose of this surveillance mechanism is to prevent loss or gain of chromosomes in daughter cells that according to current understanding contributes to cancer formation. Numerous proteins participate in the regulation of mitotic progression. In this thesis, the mitotic tasks of three kinetochore proteins, Shugoshin 1 (Sgo1), INCENP, and p38 MAP kinase (p38 MAPK), were investigated. Sgo1 is a protector of centromeric cohesion. It is also described in the tension-sensing mechanism of the SAC and in the regulation of kinetochore-microtubule connections. Our results revealed a central role for Sgo1 in a novel branch of kinetochore assembly. INCENP constitutes part of the chromosomal passenger complex (CPC). The other members of the core complex are the Aurora B kinase, Survivin and Borealin. CPC is an important regulatory element of cell division having several roles at various stages of mitosis. Our results indicated that INCENP and Aurora B are highly dynamic proteins at the mitotic centromeres and suggested a new role for CPC in regulation of chromosome movements and spindle structure during late mitosis. The p38 MAPK has been implicated in G1 and G2 checkpoints during the cell cycle. However, its role in mitotic progression and control of SAC signaling has been controversial. In this thesis, we discovered a novel function for p38γ MAPK in chromosome orientation and spindle structure as well as in promotion of viability of mitotic cells.
Resumo:
A mancha-amarela do trigo, causada pelo fungo Drechslera tritici-repentis, é de ocorrência mundial e uma das principais doenças da cultura. No Brasil, a mesma está presente em todas as safras e pode reduzir o rendimento de grãos em mais de 40%. A sua ampla adaptabilidade a ambientes diversos pode estar relacionada à capacidade dos esporos germinarem sob diferentes temperaturas, assunto que foi examinado neste experimento conduzido na UPF, em 2011. Suspensões de conídios (350 µL) foram depositadas em placas de Petri com meio ágar-água e incubadas em câmara tipo BOD, na presença e ausência de luz, a -5, 0, 5, 10, 15, 20, 25, 30, 35 e 40ºC, por 2, 4, 6, 8 e 10 horas. O trabalho foi conduzido duas vezes, em delineamento inteiramente casualizado, com quatro repetições. Os conídios germinaram tanto na presença como na ausência de luz. A germinação foi nula a -5ºC ou 40ºC. A mesma foi detectada após 2h e aumentou com o tempo de incubação. Através de polinômios de segundo grau estimou-se a máxima germinação a 19ºC e 9,5h de incubação. Houve predominância da germinação bipolar (frequência de 45,0%), seguida da intercalar (33,5%) e da unipolar (21,5%). Os resultados obtidos indicam grande amplitude térmica para germinação dos conídios de D. tritici-repentis, o que explica, parcialmente, sua ampla distribuição geográfica.
Resumo:
Tehoelektroniikkalaitteiden tehon kasvun myötä niiden hyötysuhteesta on tullut yksi niiden tärkeimmistä ominaisuuksista. Suurilla tehoilla prosentuaalisesti pienetkin tehohäviöt ovat merkittäviä ja aiheuttavat laitteen käyttäjälle ylimääräisiä energiakustannuksia ja tarvetta hukkalämmön poistolle. Näistä syistä asiakkaat vaativat hyvällä hyötysuhteella toimivia laitteita, joten laitevalmistajat pyrkivät tekemään niistä sellaisia. Simulaatiomallit ovat arvokkaita työkaluja laitesuunnittelussa. Hyötysuhdeoptimoinnin kannalta tehohäviöt tulisi pystyä mallintamaan, jotta komponenttivalintojen, ohjaustapojen ja pääpiiritopologioiden vaikutusta hyötysuhteeseen voitaisiin arvioida. Tässä työssä perehdytään eristehilabipolaaritransistorista (IGBT) tehtyihin simulaatiomalleihin ja arvioidaan niiden soveltuvuutta IGBT:ssä syntyvien tehohäviöiden mallintamiseen. Lisäksi verrataan mallia mittaukseen ja pohditaan, millaiset vaatimukset simulaatiomalliin todellisuudessa kohdistuvat.
Resumo:
Nowadays power drives are the essential part almost of all technological processes. Improvement of efficiency and reduction of losses require development of semiconductor switches. It has a particular meaning for the constantly growing market of renewable sources, especially for wind turbines, which demand more powerful semiconductor devices for control with growth of power. Also at present semiconductor switches are the key component in energy transmission, optimization of generation and network connection. The aim of this thesis is to make a survey of contemporary semiconductor components, showing difference in structures, advantages, disadvantages and most suitable applications. There is topical information about voltage, frequency and current limits of different switches. Study tries to compare dimensions and price of different components. Main manufacturers of semiconductor components are presented with the review of devices produced by them, and a conclusion about their availability was made. IGBT is selected as a main component in this study, because nowadays it is the most attractive component for usage in power drives, especially at the low levels of medium voltage. History of development of IGBT structure, static and dynamic characteristics are considered. Thesis tells about assemblies and connection of components and problems which can appear. One of key questions about semiconductor materials and their future development was considered. For the purpose of comparison strong and weak sides of different switches, calculation of losses of IGBT and its basic competitor – IGCT is presented. This master’s thesis makes an effort to answer the question if there are at present possibilities of accurate selection of switches for electrical drives of different rates of power and looks at future possible ways of development of semiconductor market.
Resumo:
This report describes a leiomyoma of the inferior third section of the esophagus removed during laparoscopic cholecystectomy. The patient is a woman 55-years-age, carrying esophageal myoma of 40 mm in diameter wide, situated in the posterior wall of the lower esophagus. Indications for surgery were based mainly on the growth of the mass (6 mm when discovered 7 years previously, increased to 40 mm). Recently the patient returned suffering from pain, which could be attributed to his litiasic cholecystopaty. A small degree of low disphagia could also be observed. Radiologic imaging, direct endoscopic examination and endoscopic ultrasound showed that the mioma protruded on to the oesophagic lumen, discreetly diminishing there. A laparoscopic esophageal myomectomy was indicated at the same session of the laparoscopic cholecystectomy. Once the pneunoperitoneum was installed, five ports were placed as if for a hiatus hernia surgery. The cholecystectomy was uneventful. Next, an esophagoscopy was performed so as to determine the precise area covering the base of the tumour; at the right-lateral site. Longitudinal and circular fibres of the esophagus was severed over the lesion and the enucleation of the tumour was performed alternating the monopolar dissection, bipolar and hidrodisection. Control-endoscopy was carried out to verify mucosa integrity. Four suture points with poliglactine 3-0 string so as to close the musculature followed this. One suture was placed in for diminution of the size of the esophagean hiatus. Total time of intervention: two hours (30m for the cholecystectomy and one hour and thirty minutes for the myomectomy). Postoperative period: uneventful. Disappearance of the disphagia was observed. Radiologic transit control with water-soluble contrast at 4th post-operative day: good passage. Diagnosis from laboratory of pathology: conjunctive tumour formed by muscle non-striated cells: leiomyoma. The patient was re-examined on the two-month postoperative follow-up. General conditions were good and there were no complain of dysphagia. Neither there were any symptoms of gastro-esophageal reflux.
Resumo:
OBJETIVO: Estabelecer um modelo de insuficiência renal crônica (IRC) em coelhos, com perspectivas de seu uso para ações terapêuticas e reparadoras. MÉTODO: Foram utilizados 19 coelhos da linhagem Nova Zelândia, machos, adultos, aleatoriamente distribuídos em três Grupos: Grupo 1 - Controle (n =5), Grupo 2- Simulação (n =7), Grupo 3 - Experimental (n =7). Os animais foram anestesiados com Cetamina e Diazepam e Fentanil por via intramuscular e Sevorane, através de vaporizador. No Grupo 3 realizou-se uma nefrectomia bipolar esquerda e após quatro semanas, uma nefrectomia direita. Todas as amostras do parênquima renal foram pesadas. O Grupo 2 foi submetido a duas laparotomias, sem nefrectomia.. Em todos os grupos foram realizadas avaliações: bioquímicas com dosagens de uréia, creatinina, sódio e potássio; ultra-sonográficas abdominais; cintigráficas e histológicas. RESULTADOS: No Grupo 3 houve aumento progressivo da uréia (p=0.0001), creatinina (p=0,0001), sódio (p= 0,0002) e potássio (p=0,0003). A comparação destes resultados com os dos Grupos 1 e 2, nos diversos intervalos, também revelou elevação sérica, com significância estatística (p < 0,05). A ultra-sonografia identificou aumento do rim esquerdo no grupo 3, após 16 semanas. A cintigrafia comprovou, na 4ª semana, perda de 75%da massa renal esquerda. No Grupo 3, a avaliação histológica evidenciou fibrose subcapsular e intersticial e regeneração tubular. CONCLUSÃO: O modelo experimental de IRC é exeqüível, com sobrevida dos animais, em médio prazo, o que permite o uso deste intervalo como janela terapêutica para testar diferentes ações reparadoras ao parênquima renal comprometido.
Resumo:
OBJETIVO: identificar e avaliar as complicações do tratamento da hérnia inguinal com a colocação de tela totalmente extraperitoneal. MÉTODOS: Foram incluídos, em uma série consecutiva de 4565 reparos de hérnia laparoscópica, pacientes que haviam sido submetidos ao procedimento TEP entre janeiro de 2001 e janeiro de 2011. Os critérios de inclusão foram: diagnóstico com hérnia inguinal sintomática, incluindo recorrência após correção de hérnia inguinal e cirurgia prévia em abdômen inferior e pelve. Todos os pacientes > 18 anos de idade. Pacientes com hérnia encarcerada na urgência foram excluídos do estudo. RESULTADOS: Um total de 4565 hérnias foram incluídas no estudo. Ocorreram 27 complicações graves (0,6%): 12 hemorragias (0,25%), duas lesões da bexiga (0,04%), cinco oclusões (0,11%), quatro perfurações intestinais (0,09%), uma lesão da veia ilíaca (0,02%), uma lesão do nervo femoral (0,02%), duas lesões dos vasos deferentes (0,04%) e dois óbitos (0,02%) (embolia pulmonar, peritonite). CONCLUSÃO: A taxa de complicações com o procedimento TEP é baixa. Correção de hérnia laparoscópica é uma técnica reprodutível e confiável. Em nossa experiência, existem contraindicações para o procedimento de TEP. A técnica TEP deve ser minuciosa para evitar complicações intraoperatórias (diatermia bipolar). As complicações podem ocorrer mesmo após o cirurgião ter adquirido experiência substancial.
Resumo:
Frequency converters are widely used in the industry to enable better controllability and efficiency of variable speed AC motor drives. Despite these advantages, certain challenges concerning the inverter and motor interfacing have been present for decades. As insulated gate bipolar transistors entered the market, the inverter output voltage transition rate significantly increased compared with their predecessors. Inverters operate based on pulse width modulation of the output voltage, and the steep voltage edge fed by the inverter produces a motor terminal overvoltage. The overvoltage causes extra stress to the motor insulation, which may lead to a prematuremotor failure. The overvoltage is not generated by the inverter alone, but also by the sum effect of the motor cable length and the impedance mismatch between the cable and the motor. Many solutions have been shown to limit the overvoltage, and the mainstream products focus on passive filters. This doctoral thesis studies an alternative methodology for motor overvoltage reduction. The focus is on minimization of the passive filter dimensions, physical and electrical, or better yet, on operation without any filter. This is achieved by additional inverter control and modulation. The studied methods are implemented on different inverter topologies, varying in nominal voltage and current.For two-level inverters, the studied method is termed active du/dt. It consists of a small output LC filter, which is controlled by an independent modulator. The overvoltage is limited by a reduced voltage transition rate. For multilevel inverters, an overvoltage mitigation method operating without a passive filter, called edge modulation, is implemented. The method uses the capability of the inverter to produce two switching operations in the same direction to cancel the oscillating voltages of opposite phases. For parallel inverters, two methods are studied. They are both intended for two-level inverters, but the first uses individual motor cables from each inverter while the other topology applies output inductors. The overvoltage is reduced by interleaving the switching operations to produce a similar oscillation accumulation as with the edge modulation. The implementation of these methods is discussed in detail, and the necessary modifications to the control system of the inverter are presented. Each method is experimentally verified by operating industrial frequency converters with the modified control. All the methods are found feasible, and they provide sufficient overvoltage protection. The limitations and challenges brought about by the methods are discussed.
Resumo:
In this doctoral thesis, methods to estimate the expected power cycling life of power semiconductor modules based on chip temperature modeling are developed. Frequency converters operate under dynamic loads in most electric drives. The varying loads cause thermal expansion and contraction, which stresses the internal boundaries between the material layers in the power module. Eventually, the stress wears out the semiconductor modules. The wear-out cannot be detected by traditional temperature or current measurements inside the frequency converter. Therefore, it is important to develop a method to predict the end of the converter lifetime. The thesis concentrates on power-cycling-related failures of insulated gate bipolar transistors. Two types of power modules are discussed: a direct bonded copper (DBC) sandwich structure with and without a baseplate. Most common failure mechanisms are reviewed, and methods to improve the power cycling lifetime of the power modules are presented. Power cycling curves are determined for a module with a lead-free solder by accelerated power cycling tests. A lifetime model is selected and the parameters are updated based on the power cycling test results. According to the measurements, the factor of improvement in the power cycling lifetime of modern IGBT power modules is greater than 10 during the last decade. Also, it is noticed that a 10 C increase in the chip temperature cycle amplitude decreases the lifetime by 40%. A thermal model for the chip temperature estimation is developed. The model is based on power loss estimation of the chip from the output current of the frequency converter. The model is verified with a purpose-built test equipment, which allows simultaneous measurement and simulation of the chip temperature with an arbitrary load waveform. The measurement system is shown to be convenient for studying the thermal behavior of the chip. It is found that the thermal model has a 5 C accuracy in the temperature estimation. The temperature cycles that the power semiconductor chip has experienced are counted by the rainflow algorithm. The counted cycles are compared with the experimentally verified power cycling curves to estimate the life consumption based on the mission profile of the drive. The methods are validated by the lifetime estimation of a power module in a direct-driven wind turbine. The estimated lifetime of the IGBT power module in a direct-driven wind turbine is 15 000 years, if the turbine is located in south-eastern Finland.
Resumo:
Objetivo: comparar o grau de aderências no ovário de acordo com diferentes tipos de fechamento do córtex ovariano. Métodos: quinze coelhos foram distribuídos aleatoriamente em três grupos, de acordo com o tipo de fechamento do córtex ovariano, sendo utilizados a diatermia bipolar, a poliglactina 910 5-0 e o categute simples 5-0. Após 2 semanas os animais foram sacrificados e o grau de aderências do ovário direito foi avaliado segundo a classificação de Diamond. O ovário esquerdo, não incisado, serviu de controle. Na análise estatística foram empregados a análise de variância (ANOVA), o teste de Scheffé e o teste t de Student. Resultados: as médias dos escores de aderência para o grupo bipolar, poliglactina e categute simples foram 0,7, 1,5 e 2,0, respectivamente. A análise de variância detectou diferença significativa (p=0,02) entre os três grupos. Usando-se o teste de Scheffé para a comparação dos grupos dois a dois, encontrou-se uma diferença significativa apenas entre o grupo bipolar e o grupo do categute simples. Comparando-se o grupo em que se usaram suturas (independente do material empregado) com o grupo bipolar verificou-se uma diferença estatisticamente significativa (p=0,01) entre as médias dos escores de aderência do ovário direito (1,8 e 0,7, respectivamente). Conclusões: os resultados obtidos no presente estudo estão de acordo com os dados da literatura, indicando que o fechamento por segunda intenção do córtex ovariano é mais vantajoso, em relação à formação de aderências, que o fechamento com o uso de suturas.
Resumo:
OBJETIVO: descrever as complicações maternas decorrentes dos procedimentos endoscópicos terapêuticos em Medicina fetal, realizados em um centro universitário no Brasil. MÉTODOS: estudo observacional retrospectivo que incluiu gestantes atendidas no período de Abril de 2007 a Maio de 2010. Esses casos foram submetidos aos seguintes procedimentos: ablação vascular placentária com laser (AVPL) por síndrome de transfusão feto-fetal (STFF) grave; oclusão traqueal fetal (OTF) e retirada de balão traqueal por via endoscópica por hérnia diafragmática congênita (HDC) grave e AVPL, com ou sem cauterização bipolar do cordão umbilical, por síndrome da perfusão arterial reversa (SPAR) em gêmeo acárdico. As principais variáveis descritas para cada condição clínica/tipo de cirurgia foram as complicações maternas e a sobrevida (alta do berçário) do neonato/lactente. RESULTADOS: cinquenta e seis gestantes foram submetidas a 70 procedimentos: STFF grave (34 pacientes; 34 cirurgias); HDC grave (16 pacientes; 30 cirurgias) e SPAR (6 pacientes; 6 cirurgias). Entre as 34 gestantes tratadas com AVPL por STFF, duas (2/34=5,9%) apresentaram perda de líquido amniótico para a cavidade peritoneal e sete (7/34=20,6%) tiveram abortamento após os procedimentos. A sobrevida de pelo menos um gêmeo foi de 64,7% (22/34). Entre as 30 intervenções realizadas para HDC, houve perda de líquido amniótico para a cavidade peritoneal materna em um caso (1/30=3,3%) e rotura prematura pré-termo de membranas após três (3/30=30%) fetoscopias para retirada do balão traqueal. A sobrevida com alta do berçário foi de 43,8% (7/16). Entre os seis casos de SPAR, houve sangramento materno para a cavidade peritoneal após uma cirurgia (1/6=16,7%) e a sobrevida com alta do berçário foi de 50% (3/6). CONCLUSÕES: em concordância com os dados disponíveis na literatura, em nosso centro, os benefícios relacionados às intervenções endoscópicas terapêuticas em casos de STFF, HDC e SPAR parecem superar os riscos de complicações maternas que, raramente, foram consideradas graves.
Resumo:
PURPOSE: To verify the predictors of intravasation rate during hysteroscopy.METHODS: Prospective observational study (Canadian Task Force classification II-1). All cases (n=200 women; 22 to 86 years old) were treated in an operating room setting. Considering respective bag overfill to calculate water balance, we tested two multiple linear regression models: one for total intravasation (mL) and the other for absorption rate (mL.min-1). The predictors tested (independent variables) were energy (mono/bipolar), tube patency (with/without tubal ligation), hysterometry (cm), age≤50 years, body surface area (m2), surgical complexity (with/without myomectomy) and duration (min).RESULTS: Mean intravasation was significantly higher when myomectomy was performed (442±616 versus 223±332 mL; p<0.01). In the proposed multiple linear regression models for total intravasation (adjusted R2=0.44; p<0.01), the only significant predictors were myomectomy and duration (p<0.01).In the proposed model for intravasation rate (R2=0.39; p<0.01), only myomectomy and hysterometry were significant predictors (p=0.02 and p<0.01, respectively).CONCLUSIONS: Not only myomectomy but also hysterometry were significant predictors of intravasation rate during operative hysteroscopy.
Resumo:
OBJETIVO: Avaliar os resultados reprodutivos após septoplastia histeroscópica.MÉTODOS: Estudo retrospetivo observacional por meio de análise dos registos clínicos de 28 mulheres com antecedentes de infertilidade ou de abortos recorrentes, submetidas à septoplastia histeroscópica. Para a avaliação do desfecho reprodutivo foram consultados os registos informáticos dos Cuidados de Saúde Primários e do nosso Centro Hospitalar, no período compreendido entre a septoplastia e a primeira gravidez ou o presente. Os outcomes primários foram a taxa de gravidez, de recém-nascidos e de abortos após septoplastia. O septo uterino foi diagnosticado por ecografia 2D ou 3D e classificado de acordo com a classificação da American Fertility Society. A septoplastia foi realizada na fase folicular do ciclo menstrual, com recurso da energia monopolar, bipolar e/ou microtesoura. Os programas Microsoft Excel e SPSS versão 17 foram utilizados para comparação do desfecho reprodutivo prévio e posterior à septoplastia. Foi utilizado o teste exato de Fisher, considerando significado estatístico quando p<0,05.RESULTADOS: Foi realizada septoplastia histeroscópica em 20 doentes (72%) com infertilidade secundária e 8 (28%) com infertilidade primária, tendo sido necessária segunda intervenção para remoção completa do septo em 5 casos (18%). Ocorreu um caso perfuração uterina minor. Após septoplastia histeroscópica, 64% das mulheres engravidaram, obtendo-se uma taxa de nados vivos de 48%; gravidez tubária de 4%; e 19% das doentes tiveram abortos espontâneos.CONCLUSÕES: Os resultados do presente estudo estão de acordo com o descrito na literatura, tendo-se obtido uma melhoria significativa dos desfechos reprodutivos, com uma redução da taxa de aborto espontâneo de cinco vezes após a septoplastia histeroscópica.
Resumo:
In the last few years, the use of laparoscopy in veterinary medicine has expanded and consequently so was the need for studies that establish the advantages, disadvantages and possible complications of each procedure. The purpose of the current study was to describe a laparoscopic splenectomy technique and the alterations due to this access, and compare it to the open procedure in dogs. A total of 15 healthy female mongrel dogs were used, with mean weight of 17.4±2.5kg. The animals were distributed into three groups: Group IA of open splenectomy (laparotomy) using double ligation of the vessels of the splenic hilum with poliglicolic acid, Group IB of open splenectomy (laparotomy) with bipolar electrocoagulation of the splenic hilum, and Group II of laparoscopic access with bipolar electrocoagulation of the splenic hilum. Operative time, blood loss, size of incisions, complications during and after surgery were evaluated. Other parameters included pain scores, white blood cell (WBC) counts and postoperative serum concentrations of alanine aminotransferase (ALT), alkaline phosphatase (ALP), creatine kinase (CK), C-reactive protein (CRP), glucose and cortisol. No differences were found in the evaluation of parameters between both open splenectomy techniques employed. Laparoscopic access presented significant differences (p<0,05) when compared with open surgery: Longer operative time, smaller abdominal access, decrease in blood loss, lower concentrations of CRP, higher levels of CK and ALP, and lower scores in the pain scale. Laparoscopic surgery showed fewer complications of the surgical wound. No significant differences were observed between groups in the postoperative temperature, WBC, ALT, cortisol and glucose concentrations. In conclusion, the laparoscopic technique is useful for splenectomy in dogs, being advantageous in terms of blood loss, surgical stress and surgical wounds. However, it expends more operative time and causes transitory increase in hepatic and muscular enzymes.