968 resultados para backward pump
Resumo:
An improved digital backward propagation (DBP) is proposed to compensate inter-nonlinear effects and dispersion jointly in WDM systems based on an advanced perturbation technique (APT). A non-iterative weighted concept is presented to replace the iterative in analytical recursion expression, which can dramatically simplify the complexity and improve accuracy compared to the traditional perturbation technique (TPT). Furthermore, an analytical recursion expression of the output after backward propagation is obtained initially. Numerical simulations are executed for various parameters of the transmission system. The results indicate that the advanced perturbation technique will relax the step size requirements and reduce the oversampling factor when launch power is higher than -2 dBm. We estimate this technique will reduce computational complexity by a factor of around seven with respect to the conventional DBP. © 2013 Optical Society of America.
Resumo:
An injection-locking-based pump recovery system for phase-sensitively amplified links is proposed and studied experimentally. Measurements with 10 Gbaud DQPSK signals show penalty-free recovery of 0.8 GHz FWHM bandwidth pump with 63 dB overall amplification. © 2012 OSA.
Resumo:
In this work we explore numerically an experimentally the dependence of the broadened spectra on the choice of fibers and we analyze a series of basic rules to be taken into account when using nonlinear broadening to reduce the gain ripple of broadband Raman amplifiers
Resumo:
In this work, we utilize modulation instability to the broadening of the two CW-pumps of a wideband Raman amplifier. Applying nonlinear fiber process, we demonstrate a feasibility of a certain control over the broadening process, leading to clear improvements in the flatness of the amplifier gain over its operational bandwidth.
Resumo:
Optical pump controlled, remotely tunable phase-shifted fiber grating transmission filters were analyzed. The transmission peak had a full width hail maximum (FWHM) bandwidth. With increasing control pump power, the resonant peak shifted towards the longer wavelength side. The efficiency of the system was largely affected by the greater number of sections of doped fiber as well as the absence of recirculation of unabsorbed pump beam. The configuration, besides its simplicity and cost-effectiveness, exhibited wavelength-independent pump-induced phase shifts and no anisotropic effects during operation.
Resumo:
Focal points: A systematic review of the use of proton pump inhibitors was conducted among patients undergoing diagnostic fibreoptic endoscopic examination of the upper gastrointestinal tract during the period July 2001 to February 2002 inclusive A total of 2,557 patients received a PPI following endoscopy and healing doses were prescribed to 75.3 per cent of these patients An “unknown indication” was stated as a diagnosis in 958 patients (37.5 per cent) of patients studied Although endoscopic diagnosis does not appear possible in all cases, the present study demonstrates that NICE guidance to employ the lowest appropriate dose of PPI is followed
Resumo:
We present an analysis of the performance of backward-pumped discrete Raman amplifier modules designed for simultaneous amplification and dispersion and/or dispersion slope compensation, both in single-channel and in multichannel systems. Optimal module parameters are determined within a realistic range of pump and signal powers.
Resumo:
WDM signal degradation from pump phase-modulation in a one-pump 20dB net-gain fibre optical parametric amplifier is experimentally and numerically characterised for the first time using 10x59Gb/s QPSK signals.
Fibre optical parametric amplifier incorporating a Raman-pump for reduced four-wave mixing crosstalk
Resumo:
We propose and investigate an application of the method of fundamental solutions (MFS) to the radially symmetric and axisymmetric backward heat conduction problem (BHCP) in a solid or hollow cylinder. In the BHCP, the initial temperature is to be determined from the temperature measurements at a later time. This is an inverse and ill-posed problem, and we employ and generalize the MFS regularization approach [B.T. Johansson and D. Lesnic, A method of fundamental solutions for transient heat conduction, Eng. Anal. Boundary Elements 32 (2008), pp. 697–703] for the time-dependent heat equation to obtain a stable and accurate numerical approximation with small computational cost.
Resumo:
We propose and investigate an application of the method of fundamental solutions (MFS) to the radially symmetric and axisymmetric backward heat conduction problem (BHCP) in a solid or hollow cylinder. In the BHCP, the initial temperature is to be determined from the temperature measurements at a later time. This is an inverse and ill-posed problem, and we employ and generalize the MFS regularization approach [B.T. Johansson and D. Lesnic, A method of fundamental solutions for transient heat conduction, Eng. Anal. Boundary Elements 32 (2008), pp. 697–703] for the time-dependent heat equation to obtain a stable and accurate numerical approximation with small computational cost.
Resumo:
I circuti di tipo charge-pump trovano vasto impiego nell'elettronica moderna in quanto offrono un metodo semplice e totalmente integrato per elevare le basse tensioni di alimentazione tipiche dei circuiti digitali e trasformarle nelle alimentazioni adatte al pilotaggio di circuti di programmazione delle memorie, al pilotaggio dei mos di potenza, alla generazione della tensione di riferimento dei VCO nei PLL e in numerose altre applicazioni. Questa tesi studia il circuito charge-pump di Dickson nel suo comportamento sia a regime stazionario sia a regime dinamico. Al fine di aumentare l'efficienza è infatti importante attivare il circuito solo all'occorrenza, prestando attenzione al transitorio di accensione. Ogni aspetto teorico viene verificato per mezzo di simulazioni su LTSpice. Si è quindi potuto constatare che un dimensionamento corretto del numero di stadi ottimizza le prestazioni sia statiche che dinamiche sotto il vincolo di una massima occupazione d'area. L'impiego dei circuiti charge-pump si prevede possa essere sempre più diffuso in futuro, visto il trend verso un maggiore livello di integrazione dei sistemi elettronici e la tendenza ad utilizzare tensioni di alimentazione sempre più basse.
Resumo:
Inscriptions: Verso: [stamped] Photograph by Freda Leinwand. [463 West Street, Studio 229G, New York, NY 10014].
Resumo:
BACKGROUND: Observational studies evaluating the possible interaction between proton pump inhibitors (PPIs) and clopidogrel have shown mixed results. We conducted a systematic review comparing the safety of individual PPIs in patients with coronary artery disease taking clopidogrel. METHODS AND RESULTS: Studies performed from January 1995 to December 2013 were screened for inclusion. Data were extracted, and study quality was graded for 34 potential studies. For those studies in which follow-up period, outcomes, and multivariable adjustment were comparable, meta-analysis was performed.The adjusted odds or hazard ratios for the composite of cardiovascular or all-cause death, myocardial infarction, and stroke at 1 year were reported in 6 observational studies with data on individual PPIs. Random-effects meta-analyses of the 6 studies revealed an increased risk for adverse cardiovascular events for those taking pantoprazole (hazard ratio 1.38; 95% CI 1.12-1.70), lansoprazole (hazard ratio 1.29; 95% CI 1.09-1.52), or esomeprazole (hazard ratio 1.27; 95% CI 1.02-1.58) compared with patients on no PPI. This association was not significant for omeprazole (hazard ratio 1.16; 95% CI 0.93-1.44). Sensitivity analyses for the coronary artery disease population (acute coronary syndrome versus mixed) and exclusion of a single study due to heterogeneity of reported results did not have significant influence on the effect estimates for any PPIs. CONCLUSIONS: Several frequently used PPIs previously thought to be safe for concomitant use with clopidogrel were associated with greater risk of adverse cardiovascular events. Although the data are observational, they highlight the need for randomized controlled trials to evaluate the safety of concomitant PPI and clopidogrel use in patients with coronary artery disease.