588 resultados para attentional blink
Resumo:
Background - Inhibition of return (IOR) is thought to reflect inhibition of previously attended but irrelevant stimuli. Deficient IOR would increase the likelihood of revisiting previously searched locations or objects, thus leading to unproductive perseverations. Method - Therefore, using a novel IOR task, we investigated whether high scoring checkers attentional biases to threat would result in dysfunctional inhibitory functioning compared to low checkers. In two tasks, we compared 53 subclinical high and 49 low checkers regarding IOR effects for stimuli that were concordant with the concerns of high but not of low checkers (electrical kitchen appliances: e.g., toaster, kettle). The difference between the two tasks was the cueing procedure. In one task, an appliance was switched “ON” and “OFF” as an unpredictive cue, drawing attention to the functionality of the stimulus. Results - In this task, IOR was specifically attenuated in high checkers. In the other task, however, the cue was more abstract in form of a yellow outline that appeared around one of two appliances. Although the appliance was either “ON” or “OFF,” this did not seem to matter and high checkers revealed a typical IOR pattern similar to low checkers. Conclusions - We conclude that IOR mechanisms might not be generally deficient in high checkers; rather only when attention is drawn to the threatening aspects of ecologically valid stimuli, then disengagement of attention is deficient in high checkers. We make suggestions on how our task-specific findings may inform cognitive interventions that target attentional control in the treatment of checking/obsessive–compulsive disorder.
Resumo:
Four patients that had received an anterior cingulotomy (ACING) and five patients that had received both an ACING and an anterior capsulotomy (ACAPS) as an intervention for chronic, treatment refractory depression were presented with a series of dynamic emotional stimuli and invited to identify the emotion portrayed. Their performance was compared with that of a group of non-surgically treated patients with major depression (n = 17) and with a group of matched, never-depressed controls (n = 22). At the time of testing, four of the nine neurosurgery patients had recovered from their depressive episode, whereas five remained depressed. Analysis of emotion recognition accuracy revealed no significant differences between depressed and non-depressed neurosurgically treated patients. Similarly, no significant differences were observed between the patients treated with ACING alone and those treated with both ACING and ACAPS. Comparison of the emotion recognition accuracy of the neurosurgically treated patients and the depressed and healthy control groups revealed that the surgically treated patients exhibited a general impairment in their recognition accuracy compared to healthy controls. Regression analysis revealed that participants' emotion recognition accuracy was predicted by the number of errors they made on the Stroop colour-naming task. It is plausible that the observed deficit in emotion recognition accuracy was a consequence of impaired attentional control, which may have been a result of the surgical lesions to the anterior cingulate cortex. © 2007 Elsevier Ltd. All rights reserved.
Resumo:
PURPOSE. To examine the relation between ocular surface temperature (OST) assessed by dynamic thermal imaging and physical parameters of the anterior eye in normal subjects. METHODS. Dynamic ocular thermography (ThermoTracer 7102MX) was used to record body temperature and continuous ocular surface temperature for 8 s after a blink in the right eyes of 25 subjects. Corneal thickness, corneal curvature, and anterior chamber depth (ACD) were assessed using Orbscan II; noninvasive tear break-up time (NIBUT) was assessed using the tearscope; slit lamp photography was used to record tear meniscus height (TMH) and objective bulbar redness. RESULTS. Initial OST after a blink was significantly correlated only with body temperature (r = 0.80, p < 0.0005), NIBUT (r = -0.68, p < 0.005) and corneal curvature (r = -0.40, p = 0.05). A regression model containing all the variables accounted for 70% (p = 0.002) of the variance in OST, of which NIBUT (29%, p = 0.004), and body temperature (18%, p = 0.005) contributed significantly. CONCLUSIONS. The results support previous theoretical models that OST radiation is principally related to the tear film; and demonstrate that it is less related to other characteristics such as corneal thickness, corneal curvature, and anterior chamber depth. © 2007 American Academy of Optometry.
Resumo:
Aim: To determine the dynamic emitted temperature changes of the anterior eye during and immediately after wearing different materials and modalities of soft contact lenses. Method: A dynamic, non-contact infrared camera (Thermo-Tracer TH7102MX, NEC San-ei) was used to record the ocular surface temperature (OST) in 48 subjects (mean age 21.7 ± 1.9 years) wearing: lotrafilcon-A contact lenses on a daily wear (LDW; n = 8) or continuous wear (LCW; n = 8) basis; balafilcon-A contact lenses on a daily wear (BDW; n = 8) or continuous wear (BCW; n = 8) basis; etafilcon-A contact lenses on a daily disposable regimen (EDW; n = 8); and no lenses (controls; n = 8). OST was measured continuously five times, for 8 s after a blink, following a minimum of 2 h wear and immediately following lens removal. Absolute temperature, changes in temperature post-blink and the dynamics of temperature changes were calculated. Results: OST immediately following contact lens wear was significantly greater compared to non-lens wearers (37.1 ± 1.7 °C versus 35.0 ± 1.1 °C; p < 0.005), predominantly in the LCW group (38.6 ± 1.0 °C; p < 0.0001). Lens surface temperature was highly correlated (r = 0.97) to, but lower than OST (by -0.62 ± 0.3 °C). There was no difference with modality of wear (DW 37.5 ± 1.6 °C versus CW 37.8 ± 1.9 °C; p = 0.63), but significant differences were found between etafilcon A and silicone hydrogel lens materials (35.3 ± 1.1 °C versus 37.5 ± 1.5 °C; p < 0.0005). Ocular surface cooling following a blink was not significantly affected by contact lens wear with (p = 0.07) or without (p = 0.47) lenses in situ. Conclusions: Ocular surface temperature is greater with hydrogel and greater still with silicone hydrogel contact lenses in situ, regardless of modality of wear. The effect is likely to be due to the thermal transmission properties of a contact lens. © 2004 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Resumo:
Although slow waves of the electroencephalogram (EEG) have been associated with attentional processes, the functional significance of the alpha component in the EEG (8.1–12 Hz) remains uncertain. Conventionally, synchronisation in the alpha frequency range is taken to be a marker of cognitive inactivity, i.e. ‘cortical idling’. However, it has been suggested that alpha may index the active inhibition of sensory information during internally directed attentional tasks such as mental imagery. More recently, this idea has been amended to encompass the notion of alpha synchronisation as a means of inhibition of non-task relevant cortical areas irrespective of the direction of attention. Here we test the adequacy of the one idling and two inhibition hypotheses about alpha. In two experiments we investigated the relation between alpha and internally vs. externally directed attention using mental imagery vs. sensory-intake paradigms. Results from both experiments showed a clear relationship between alpha and both attentional factors and increased task demands. At various scalp sites alpha amplitudes were greater during internally directed attention and during increased load, results incompatible with alpha reflecting cortical idling and more in keeping with suggestions of active inhibition necessary for internally driven mental operations.
Resumo:
We report results from two experiments assessing distribution of attention and cue use in adults with dyslexia (AwD) and in a group of typically reading controls. Experiment 1 showed normal effects of cueing in AwD, with faster responses when probes were presented within a cued area and normal effects of eccentricity and stimulus onset asynchrony (SOA). In addition, AwD showed stronger benefits of a longer SOA when they had to move attention farther, and stronger effects of inclusion on the left, suggesting that cueing is particularly important in more difficult conditions. Experiment 2 tested the use of cues in a texture detection task involving a wider range of eccentricities and a shorter SOA. In this paradigm, focused attention at the central location is actually detrimental and cueing further reduces performance. Thus, if AwD have a more distributed attention, they should show a reduced performance drop at central locations and, if they do not use cues, they should show less negative effects of cueing. In contrast, AwD showed a larger drop and a positive effect of cueing. These results are better accounted for by a smaller and weaker spotlight of attention. Performance does not decrease at central locations because the attentional spotlight is already deployed with maximum intensity, which cannot be further enhanced at central locations. Instead, use of cueing helps to focus limited resources. Cues orient attention to the right area without enhancing it to the point where this is detrimental for texture detection. Implications for reading are discussed.
Resumo:
Purpose: To quantify the end-of-day silicone-hydrogel daily disposable contact lens fit and its influence of on ocular comfort, physiology and lens wettability. Methods: Thirty-nine subjects (22.1. ±. 3.5 years) were randomised to wear each of 3 silicone-hydrogel daily-disposable contact lenses (narafilcon A, delefilcon A and filcon II 3), bilaterally, for one week. Lens fit was assessed objectively using a digital video slit-lamp at 8, 12 and 16. h after lens insertion. Hyperaemia, non-invasive tear break-up time, tear meniscus height and comfort were also evaluated at these timepoints, while corneal and conjunctival staining were assessed on lens removal. Results: Lens fit assessments were not different between brands (P > 0.05), with the exception of the movement at blink where narafilcon A was more mobile. Overall, lag reduced but push-up speed increased from 8 to 12. h (P <. 0.05), but remained stable from 12 to 16. h (P > 0.05). Movement-on-blink was unaffected by wear-time (F = 0.403, P = 0.670). A more mobile lens fit with one brand did not indicate that person would have a more mobile fit with another brand (r = -0.06 to 0.63). Lens fit was not correlated with comfort, ocular physiology or lens wettability (P > 0.01). Conclusions: Among the lenses tested, objective lens fit changed between 8. h and 12. h of lens wear. The weak correlation in individual lens fit between brands indicates that fit is dependent on more than ocular shape. Consequently, substitution of a different lens brand with similar parameters will not necessarily provide comparable lens fit.
Resumo:
Purpose: To assess the validity and repeatability of objective compared to subjective contact lens fit analysis. Methods: Thirty-five subjects (aged 22.0. ±. 3.0 years) wore two different soft contact lens designs. Four lens fit variables: centration, horizontal lag, post-blink movement in up-gaze and push-up recovery speed were assessed subjectively (four observers) and objectively from slit-lamp biomicroscopy captured images and video. The analysis was repeated a week later. Results: The average of the four experienced observers was compared to objective measures, but centration, movement on blink, lag and push-up recovery speed all varied significantly between them (p <. 0.001). Horizontal lens centration was on average close to central as assessed both objectively and subjectively (p > 0.05). The 95% confidence interval of subjective repeatability was better than objective assessment (±0.128. mm versus ±0.168. mm, p = 0.417), but utilised only 78% of the objective range. Vertical centration assessed objectively showed a slight inferior decentration (0.371. ±. 0.381. mm) with good inter- and intrasession repeatability (p > 0.05). Movement-on-blink was lower estimated subjectively than measured objectively (0.269. ±. 0.179. mm versus 0.352. ±. 0.355. mm; p = 0.035), but had better repeatability (±0.124. mm versus ±0.314. mm 95% confidence interval) unless correcting for the smaller range (47%). Horizontal lag was lower estimated subjectively (0.562. ±. 0.259. mm) than measured objectively (0.708. ±. 0.374. mm, p <. 0.001), had poorer repeatability (±0.132. mm versus ±0.089. mm 95% confidence interval) and had a smaller range (63%). Subjective categorisation of push-up speed of recovery showed reasonable differentiation relative to objective measurement (p <. 0.001). Conclusions: The objective image analysis allows an accurate, reliable and repeatable assessment of soft contact lens fit characteristics, being a useful tool for research and optimisation of lens fit in clinical practice.
Resumo:
This study identifies and investigates the potential use of in-eye trigger mechanisms to supplement the widely available information on release of ophthalmic drugs from contact lenses under passive release conditions. Ophthalmic dyes and surrogates have been successfully employed to investigate how these factors can be drawn together to make a successful system. The storage of a drug-containing lens in a pH lower than that of the ocular environment can be used to establish an equilibrium that favours retention of the drug in the lens prior to ocular insertion. Although release under passive conditions does not result in complete dye elution, the use of mechanical agitation techniques which mimic the eyelid blink action in conjunction with ocular tear chemistry promotes further release. In this way differentiation between passive and triggered in vitro release characteristics can be established. Investigation of the role of individual tear proteins revealed significant differences in their ability to alter the equilibrium between matrix-held and eluate-held dye or drug. These individual experiments were then investigated in vivo using ophthalmic dyes. Complete elution was found to be achievable in-eye; this demonstrated the importance of that fraction of the drug retained under passive conditions and the triggering effect of in-eye conditions on the release process. Understanding both the structure-property relationship between drug and material and in-eye trigger mechanisms, using ophthalmic dyes as a surrogate, provides the basis of knowledge necessary to design ocular drug delivery vehicles for in-eye release in a controllable manner.
Resumo:
Purpose: To investigate how initial HEMA and silicone-hydrogel (SiHy) contact lens fit on insertion, which informs prescribing decisions, reflect end of day fit. Methods: Thirty participants (aged 22.9. ±. 4.9 years) were fitted contralaterally with HEMA and SiHy contact lenses. Corneal topography and tear break-up time were assessed pre-lens wear. Centration, lag, post-blink movement during up-gaze and push-up recovery speed were recorded after 5,10,20. min and 8. h of contact lens wear by a digital slit-lamp biomicroscope camera, along with reported comfort. Lens fit metrics were analysed using bespoke software. Results: Comfort and centration were similar with the HEMA and SiHy lenses (p > 0.05), but comfort decreased with time (p <. 0.01) whereas centration remained stable (F = 0.036, p = 0.991). Movement-on-blink and lag were greater with the HEMA than the SiHy lens (p <. 0.01), but movement-on-blink decreased with time after insertion (F = 22.423, p <. 0.001) whereas lag remained stable (F = 1.967, p = 0.129). Push-up recovery speed was similar with the HEMA and the SiHy lens 5-20. min after insertion (p > 0.05), but was slower with SiHy after 8. h wear (p = 0.016). Lens movement on blink and push-up recovery speed was predictive of the movement after 8. h of wear after 10-20. min SiHy wear, but after 5 to 20. min of HEMA lens wear. Conclusions: A HEMA or SiHy contact lens with poor movement on blink/push-up after at least 10. min after insertion should be rejected.
Resumo:
This study aimed to: i) determine if the attention bias towards angry faces reported in eating disorders generalises to a non-clinical sample varying in eating disorder-related symptoms; ii) examine if the bias occurs during initial orientation or later strategic processing; and iii) confirm previous findings of impaired facial emotion recognition in non-clinical disordered eating. Fifty-two females viewed a series of face-pairs (happy or angry paired with neutral) whilst their attentional deployment was continuously monitored using an eye-tracker. They subsequently identified the emotion portrayed in a separate series of faces. The highest (n=18) and lowest scorers (n=17) on the Eating Disorders Inventory (EDI) were compared on the attention and facial emotion recognition tasks. Those with relatively high scores exhibited impaired facial emotion recognition, confirming previous findings in similar non-clinical samples. They also displayed biased attention away from emotional faces during later strategic processing, which is consistent with previously observed impairments in clinical samples. These differences were related to drive-for-thinness. Although we found no evidence of a bias towards angry faces, it is plausible that the observed impairments in emotion recognition and avoidance of emotional faces could disrupt social functioning and act as a risk factor for the development of eating disorders.
Resumo:
The aims of this thesis were to investigate the neuropsychological, neurophysiological, and cognitive contributors to mobility changes with increasing age. In a series of studies with adults aged 45-88 years, unsafe pedestrian behaviour and falls were investigated in relation to i) cognitive functions (including response time variability, executive function, and visual attention tests), ii) mobility assessments (including gait and balance and using motion capture cameras), iii) motor initiation and pedestrian road crossing behavior (using a simulated pedestrian road scene), iv) neuronal and functional brain changes (using a computer based crossing task with magnetoencephalography), and v) quality of life questionnaires (including fear of falling and restricted range of travel). Older adults are more likely to be fatally injured at the far-side of the road compared to the near-side of the road, however, the underlying mobility and cognitive processes related to lane-specific (i.e. near-side or far-side) pedestrian crossing errors in older adults is currently unknown. The first study explored cognitive, motor initiation, and mobility predictors of unsafe pedestrian crossing behaviours. The purpose of the first study (Chapter 2) was to determine whether collisions at the near-side and far-side would be differentially predicted by mobility indices (such as walking speed and postural sway), motor initiation, and cognitive function (including spatial planning, visual attention, and within participant variability) with increasing age. The results suggest that near-side unsafe pedestrian crossing errors are related to processing speed, whereas far-side errors are related to spatial planning difficulties. Both near-side and far-side crossing errors were related to walking speed and motor initiation measures (specifically motor initiation variability). The salient mobility predictors of unsafe pedestrian crossings determined in the above study were examined in Chapter 3 in conjunction with the presence of a history of falls. The purpose of this study was to determine the extent to which walking speed (indicated as a salient predictor of unsafe crossings and start-up delay in Chapter 2), and previous falls can be predicted and explained by age-related changes in mobility and cognitive function changes (specifically within participant variability and spatial ability). 53.2% of walking speed variance was found to be predicted by self-rated mobility score, sit-to-stand time, motor initiation, and within participant variability. Although a significant model was not found to predict fall history variance, postural sway and attentional set shifting ability was found to be strongly related to the occurrence of falls within the last year. Next in Chapter 4, unsafe pedestrian crossing behaviour and pedestrian predictors (both mobility and cognitive measures) from Chapter 2 were explored in terms of increasing hemispheric laterality of attentional functions and inter-hemispheric oscillatory beta power changes associated with increasing age. Elevated beta (15-35 Hz) power in the motor cortex prior to movement, and reduced beta power post-movement has been linked to age-related changes in mobility. In addition, increasing recruitment of both hemispheres has been shown to occur and be beneficial to perform similarly to younger adults in cognitive tasks (Cabeza, Anderson, Locantore, & McIntosh, 2002). It has been hypothesised that changes in hemispheric neural beta power may explain the presence of more pedestrian errors at the farside of the road in older adults. The purpose of the study was to determine whether changes in age-related cortical oscillatory beta power and hemispheric laterality are linked to unsafe pedestrian behaviour in older adults. Results indicated that pedestrian errors at the near-side are linked to hemispheric bilateralisation, and neural overcompensation post-movement, 4 whereas far-side unsafe errors are linked to not employing neural compensation methods (hemispheric bilateralisation). Finally, in Chapter 5, fear of falling, life space mobility, and quality of life in old age were examined to determine their relationships with cognition, mobility (including fall history and pedestrian behaviour), and motor initiation. In addition to death and injury, mobility decline (such as pedestrian errors in Chapter 2, and falls in Chapter 3) and cognition can negatively affect quality of life and result in activity avoidance. Further, number of falls in Chapter 3 was not significantly linked to mobility and cognition alone, and may be further explained by a fear of falling. The objective of the above study (Study 2, Chapter 3) was to determine the role of mobility and cognition on fear of falling and life space mobility, and the impact on quality of life measures. Results indicated that missing safe pedestrian crossing gaps (potentially indicating crossing anxiety) and mobility decline were consistent predictors of fear of falling, reduced life space mobility, and quality of life variance. Social community (total number of close family and friends) was also linked to life space mobility and quality of life. Lower cognitive functions (particularly processing speed and reaction time) were found to predict variance in fear of falling and quality of life in old age. Overall, the findings indicated that mobility decline (particularly walking speed or walking difficulty), processing speed, and intra-individual variability in attention (including motor initiation variability) are salient predictors of participant safety (mainly pedestrian crossing errors) and wellbeing with increasing age. More research is required to produce a significant model to explain the number of falls.
Resumo:
Technological advancements and the ever-evolving demands of a global marketplace may have changed the way in which training is designed, implemented, and even managed, but the ultimate goal of organizational training programs remains the same: to facilitate learning of a knowledge, skill, or other outcome that will yield improvement in employee performance on the job and within the organization (Colquitt, LePine, & Noe, 2000; Tannenbaum & Yukl, 1992). Studies of organizational training have suggested medium to large effect sizes for the impact of training on employee learning (e.g., Arthur, Bennett, Edens, & Bell, 2003; Burke & Day, 1986). However, learning may be differentially affected by such factors as the (1) level and type of preparation provided prior to training, (2) targeted learning outcome, (3) training methods employed, and (4) content and goals of training (e.g., Baldwin & Ford, 1988). A variety of pre-training interventions have been identified as having the potential to enhance learning from training and practice (Cannon-Bowers, Rhodenizer, Salas, & Bowers, 1998). Numerous individual studies have been conducted examining the impact of one or more of these pre-training interventions on learning. ^ I conducted a meta-analytic examination of the effect of these pre-training interventions on cognitive, skill, and affective learning. Results compiled from 359 independent studies (total N = 37,038) reveal consistent positive effects for the role of pre-training interventions in enhancing learning. In most cases, the provision of a pre-training intervention explained approximately 5–10% of the variance in learning, and in some cases, explained up to 40–50% of variance in learning. Overall attentional advice and meta-cognitive strategies (as compared with advance organizers, goal orientation, and preparatory information) seem to result in the most consistent learning gains. Discussion focuses on the most beneficial match between an intervention and the learning outcome of interest, the most effective format of these interventions, and the most appropriate circumstances under which these interventions should be utilized. Also highlighted are the implications of these results for practice, as well as propositions for important avenues for future research. ^
Resumo:
Dry eye syndrome is a multifactorial disease of the tear film, resulting from the instability of the lacrimal functional unit that produces volume change, up or tear distribution. In patients in intensive care the cause is enhanced due to various risk factors, such as mechanical ventilation, sedation, lagophthalmos, low temperatures, among others. The study's purpose is to build an assessment tool of Dry Eye Severity in patients in intensive care units based on the systematization of nursing care and their classification systems. The aim of this study is to build an assessment tool of Dry Eye Severity in hospitalized patients in Care Unit Intensiva.Trata is a methodological study conducted in three stages, namely: context analysis, concept analysis, construction of operational definitions and magnitudes of nursing outcome. For the first step we used the methodological framework for Hinds, Chaves and Cypress (1992). For the second step we used the model of Walker and Avant and an integrative review Whitemore seconds, Knalf (2005). This step enabled the identification of the concept of attributes, background and consequent ground and the construction of the settings for the result of nursing severity of dry eye. For the construction of settings and operational magnitudes, it was used Psicometria proposed by Pasquali (1999). As a result of context analysis, visualized from the reflection that the matter should be discussed and that nursing needs to pay attention to the problem of eye injury, so minimizing strategies are created this event with a high prevalence. With the integrative review were located from the crosses 19 853 titles, selected 215, and from the abstracts 96 articles were read in full. From reading 10 were excluded culminating in the sample of 86 articles that were used to analyze the concept and construction of settings. Selected articles were found in greater numbers in the Scopus database (55.82%), performed in the United States (39.53%), and published mainly in the last five years (48.82). Regarding the concept of analysis were identified as antecedents: age, lagophthalmos, environmental factors, medication use, systemic diseases, mechanical ventilation and ophthalmic surgery. As attributes: TBUT <10s, Schimer I test <5 mm in Schimer II test <10mm, reduced osmolarity. As consequential: the ocular surface damage, ocular discomfort, visual instability. The settings were built and added indicators such as: decreased blink mechanism and eyestrain.
Resumo:
Pour être performant au plus haut niveau, les athlètes doivent posséder une capacité perceptivo-cognitive supérieure à la moyenne. Cette faculté, reflétée sur le terrain par la vision et l’intelligence de jeu des sportifs, permet d’extraire l’information clé de la scène visuelle. La science du sport a depuis longtemps observé l’expertise perceptivo-cognitive au sein de l’environnement sportif propre aux athlètes. Récemment, des études ont rapporté que l’expertise pouvait également se refléter hors de ce contexte, lors d’activités du quotidien par exemple. De plus, les récentes théories entourant la capacité plastique du cerveau ont amené les chercheurs à développer des outils pour entraîner les capacités perceptivo-cognitives des athlètes afin de les rendre plus performants sur le terrain. Ces méthodes sont la plupart du temps contextuelles à la discipline visée. Cependant, un nouvel outil d’entraînement perceptivo-cognitif, nommé 3-Dimensional Multiple Object Tracking (3D-MOT) et dénué de contexte sportif, a récemment vu le jour et a fait l’objet de nos recherches. Un de nos objectifs visait à mettre en évidence l’expertise perceptivo-cognitive spécifique et non-spécifique chez des athlètes lors d’une même étude. Nous avons évalué la perception du mouvement biologique chez des joueurs de soccer et des non-athlètes dans une salle de réalité virtuelle. Les sportifs étaient systématiquement plus performants en termes d’efficacité et de temps de réaction que les novices pour discriminer la direction du mouvement biologique lors d’un exercice spécifique de soccer (tir) mais également lors d’une action issue du quotidien (marche). Ces résultats signifient que les athlètes possèdent une meilleure capacité à percevoir les mouvements biologiques humains effectués par les autres. La pratique du soccer semble donc conférer un avantage fondamental qui va au-delà des fonctions spécifiques à la pratique d’un sport. Ces découvertes sont à mettre en parallèle avec la performance exceptionnelle des athlètes dans le traitement de scènes visuelles dynamiques et également dénuées de contexte sportif. Des joueurs de soccer ont surpassé des novices dans le test de 3D-MOT qui consiste à suivre des cibles en mouvement et stimule les capacités perceptivo-cognitives. Leur vitesse de suivi visuel ainsi que leur faculté d’apprentissage étaient supérieures. Ces résultats confirmaient des données obtenues précédemment chez des sportifs. Le 3D-MOT est un test de poursuite attentionnelle qui stimule le traitement actif de l’information visuelle dynamique. En particulier, l’attention sélective, dynamique et soutenue ainsi que la mémoire de travail. Cet outil peut être utilisé pour entraîner les fonctions perceptivo-cognitives des athlètes. Des joueurs de soccer entraînés au 3D-MOT durant 30 sessions ont montré une amélioration de la prise de décision dans les passes de 15% sur le terrain comparés à des joueurs de groupes contrôles. Ces données démontrent pour la première fois un transfert perceptivo-cognitif du laboratoire au terrain suivant un entraînement perceptivo-cognitif non-contextuel au sport de l’athlète ciblé. Nos recherches aident à comprendre l’expertise des athlètes par l’approche spécifique et non-spécifique et présentent également les outils d’entraînements perceptivo-cognitifs, en particulier le 3D-MOT, pour améliorer la performance dans le sport de haut-niveau.