980 resultados para aortic banding


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study sought to describe the natural history of combined stenotic and regurgitant aortic valve disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although routine ultrasound screening for abdominal aortic aneurysm (AAA) reduces mortality in subjects at risk, it is often omitted in clinical practice. Because computerized alerts may systematically identify subjects at risk of AAA, we hypothesized that such alerts would encourage physicians to perform an ultrasound screening test.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To report percutaneous fenestration of aortic dissection flaps to relieve distal ischemia using a novel intravascular ultrasound (IVUS)-guided fenestration device. CASE REPORTS: Two men (47 and 62 years of age) with aortic dissection and intermittent claudication had percutaneous ultrasound-guided fenestration performed under local anesthesia. Using an ipsilateral transfemoral approach, the intimal flap was punctured under real-time IVUS guidance using a needle-catheter combination through which a guidewire was placed across the dissection flap into the false lumen. The fenestration was achieved using balloon catheters of increasing diameter introduced over the guidewire. Stenting of the re-entry was performed in 1 patient to equalize pressure across the dissection membrane in both lumens. The procedures were performed successfully and without complications. In both patients, ankle-brachial indexes improved from 0.76 to 1.07 and from 0.8 to 1.1, respectively. Both patients were without claudication at the 3- and 6-month follow-up examination. CONCLUSION: Percutaneous intravascular ultrasound-guided fenestration and stenting at the level of the iliac artery in aortic dissection patients with claudication is a technically feasible and safe procedure and relieves symptoms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The study was conducted to determine activation of coagulation in patients undergoing open and endovascular infrarenal abdominal aortic aneurysm repair (EVAR). METHODS: In a prospective, comparative study, 30 consecutive patients undergoing open repair (n = 15) or EVAR (n = 15) were investigated. Blood samples to determine fibrinopeptide A, fibrin monomer, thrombin-antithrombin complex, and D-dimer were taken up to 5 days postoperatively. Routine hematologic and hematochemical parameters as well as clinical data were collected. RESULTS: Both groups showed comparable demographic variables. Operating time was longer in open repair (249 +/- 77 minutes vs 186 +/- 69 minutes, P < .05). Perioperatively elevated markers of coagulation were measured in both groups. Fibrinopeptide A levels did not differ significantly between the groups (P = .55). The levels of fibrin monomer and thrombin-antithrombin complex were significantly higher in patients undergoing EVAR (P < .0001), reflecting increased thrombin activity and thrombin formation compared with open surgery. The D-dimer level did not differ significantly between the groups. These results were also valid after correction for hemodilution. CONCLUSION: These data suggest increased procoagulant activity in EVAR compared with open surgery. A procoagulant state may favor possible morbidity derived from micro- and macrovascular thrombosis, such as in myocardial infarction, multiple organ dysfunction, venous thrombosis and thromboembolism, or disseminated intravascular coagulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: The goal of this study was to assess the prevalence of left ventricular (LV) hypertrophy in patients with aortic stenosis late (>6 months) after aortic valve replacement and its impact on cardiac-related morbidity and mortality. METHODS AND RESULTS: In a single tertiary centre, echocardiographic data of LV muscle mass were collected. Detailed information of medical history and angiographic data were gathered. Ninety-nine of 213 patients (46%) had LV hypertrophy late (mean 5.8 +/- 5.4 years) after aortic valve replacement. LV hypertrophy was associated with impaired exercise capacity, higher New York Heart Association dyspnoea class, a tendency for more frequent chest pain expressed as higher Canadian Cardiovascular Society class, and more rehospitalizations. 24% of patients with normal LV mass vs. 39% of patients with LV hypertrophy reported cardiac-related morbidity (p = 0.04). In a multivariate logistic regression model, LV hypertrophy was an independent predictor of cardiac-related morbidity (odds ratio 2.31, 95% CI 1.08 to 5.41), after correction for gender, baseline ejection fraction, and coronary artery disease and its risk factors. Thirty seven deaths occurred during a total of 1959 patient years of follow-up (mean follow-up 9.6 years). Age at aortic valve replacement (hazard ratio 1.85, 95% CI 1.39 to 2.47, for every 5 years increase in age), coexisting coronary artery disease at the time of surgery (hazard ratio 3.36, 95% CI 1.31 to 8.62), and smoking (hazard ratio 4.82, 95% CI 1.72 to 13.45) were independent predictors of overall mortality late after surgery, but not LV hypertrophy. CONCLUSIONS: In patients with aortic valve replacement for isolated aortic stenosis, LV hypertrophy late after surgery is associated with increased morbidity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Myocardial depression after cardiac surgery is modulated by cardiopulmonary bypass (CPB) and the underlying heart disease. The sodium pump is a key component for myocardial function. We hypothesized that the change in sodium pump expression during CPB correlates with intraoperative and postoperative laboratory and clinical parameters in neonates and children with various congenital heart defects. Sodium pump isoforms alpha1 (ATP1A1) and alpha3 (ATP1A3) mRNA expression in right atrial myocardium, excised before and after CPB, was quantified. Groups were assigned according to presence (VO group, n = 8) or absence (NO group, n = 8) of right atrial volume overload. CPB and aortic clamp time correlated with postoperative troponin-I values and ICU stay. ATP1A1 (P = 0.008) and ATP1A3 (P = 0.038) mRNA expression were significantly reduced during CPB. Longer aortic clamp times were associated with lower postoperative ATP1A1 (P = 0.045) and ATP1A3 (P = 0.002) mRNA expression. Low postoperative ATP1A1 (P = 0.043) and ATP1A3 (P = 0.002) expressions were associated with high troponin-I values. These results were restricted to the VO group. No correlation of sodium pump mRNA expression was found with the duration of ICU stay or ventilation. The postoperative troponin-I and clinical parameters correlated with the length of CPB, regardless of volume overload. In contrast, only dilated right atrium seemed to be susceptible to CPB in terms of sodium pump expression, showing a reduction during the operation and a correlation of sodium pump with postoperative troponin-I values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: New equipment and techniques in winter sports, such as carving skis and snowboards, have brought up new trauma patterns into the spectrum of leisure trauma. The injuries resemble high-energy trauma known from road crashes. The aim of the present study was to assess the incidence of acute traumatic descending aortic rupture in recreational skiing-crashes. MATERIAL: Between January 1995 and December 2004, 22 patients were admitted to our hospital for aortic rupture. Four patients had skiing crashes (18.2%). Mean age was 31 years, all patients were male. In two cases, aortic rupture was associated with fractures of the upper and lower extremities. One patient additionally had a cerebral contusion with an initial Glasgow Coma Scale score of 13. In two patients, isolated aortic rupture was diagnosed. RESULTS: Two patients were treated by graft interposition, and one by endograft. One patient arrived under mechanical resuscitation without blood pressure. He died at admission. He had been observed for 5 hours in another hospital, complaining of severe intrascapular back pain, before transport to our trauma unit for unknown bleeding. In the other three cases, treatment was successful. CONCLUSION: Rescue services and paramedics should be aware of this new type of injury. Acute aortic rupture has to be considered as possible injury in high velocity skiing crashes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Plasma concentrations of D-dimer may prove a valuable addition in the diagnostic work-up of acute type A aortic dissection, but not as means of predicting mortality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Integrity of the abdominal aortic aneurysm (AAA) neck is crucial for the long-term success of endovascular AAA repair (EVAR). However, suitable tools for reliable assessment of changes in small aortic volumes are lacking. The purpose of this study was to assess the intraobserver and interobserver variability of software-enhanced 64-row computed tomographic angiography (CTA) AAA neck volume measurements in patients after EVAR. METHODS: A total of 25 consecutive patients successfully treated by EVAR underwent 64-row follow-up CTA in 1.5-mm collimation. Manual CTA measurements were performed twice by three blinded and independent readers in random order with at least a 4-week interval between readings. Maximum and minimum transverse aortic neck diameters were measured twice on two different levels within the proximal neck. Volumetry of the proximal aortic neck was performed by using dedicated software. Variability was calculated as 1.96 SD of the mean arithmetic difference according to Bland and Altman. Two-sided and paired t tests were used to compare measurements. P values <.05 were considered to indicate statistical significance. RESULTS: Intraobserver agreement was excellent for dedicated aneurysmal neck volumetry, with mean differences of less than 1 mL (P > .05), whereas it was poor for transverse aortic neck diameter measurements (P < .05). However, interobserver variability was statistically significant for both neck volumetry (P < .005) and neck diameter measurements (P < .015). CONCLUSIONS: The reliability of dedicated AAA neck volumetry by using 64-row CTA is excellent for serial measurements by individual readers, but not between different readers. Therefore, studies should be performed with aortic neck volumetry by a single experienced reader.