977 resultados para anti-CD18 antibody


Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report the detection of specific IgA antibodies and the determination of IgG avidity in sequential serum samples from a patient exhibiting significant levels of Toxoplasma-specific IgM antibodies for seven years after the onset of the clinical symptoms of toxoplasmosis. IgM antibodies were detected by an indirect immunofluorescence test and by three commercial enzyme-linked immunosorbent assays (ELISA). Anti-T. gondii IgA was quantified by the a-capture ELISA technique using a commercial kit. As defined by the manufacturer of the IgA ELISA test used, most patients with acute toxoplasmosis have antibody levels > 40 arbitrary units per ml (AU/mL). At this cut-off level, the patient still had a positive ELISA result (45 AU/mL) in a serum sample taken one year after the beginning of clinical manifestations. The IgG avidity-ELISA test was performed with the Falcon assay screening test (F.A.S.T.®) - ELISA system. Avidity indices compatible with a recent Toxoplasma infection were found only in serum samples taken during the first 5 months after the onset of the clinical symptoms of toxoplasmosis. These results show that the interpretation of positive IgM results as indicative of recently acquired toxoplasmosis requires additional laboratory confirmation either by other tests or by the demonstration of a significant rise in the antibody titers in sequential serum samples.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The authors studied 70 leprosy patients and 20 normal individuals, comparing the traditional sera collection method and the finger prick blood with the conservation on filter paper for specific antibodies against the native phenolic glycolipid-I (PGL-I) from Mycobacterium leprae. The finger prick blood dried on filter paper was eluated in phosphate buffer saline (PBS) containing 0.5% gelatin. The classical method for native PGL-I was performed for these eluates, and compared with the antibody determination for sera. It was observed that there is a straight correlation comparing these two methods; although the titles found for the eluates were lower than those obtained for serology. This blood collection method could be useful for investigation of new leprosy cases in field, specially in contacts individuals.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We describe the production of the potential monoclonal antibodies (MoAbs) using BALB/c mice immunized with vesicular fluid (VF)-Tcra (T. crassiceps) antigen. Immune sera presented anti-VF-Tcra (<20kD) IgG and IgM antibodies with cross-reactivity with T. solium (Tso) antigen (8-12, 14, and 18 kD). After cell fusion, we selected 33 anti-Tcra and anti-Tso reactive IgM-clones and 53 anti-Tcra specific IgG-clones, 5 of them also recognizing Tso antigens. Two clones identified the 8-14 and 18kD peptides of VF-Tcra.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The clinical significance of isolated anti-HBc is still a challenge. To elucidate the real importance of this finding in our blood donors, an investigation algorithm was tested. One hundred and twelve isolated anti-HBc seropositive blood donors underwent clinical evaluation and retesting of HBV markers. Those who presented repeatedly reactive isolated anti-HBc, received a single dose of hepatitis B recombinant vaccine to verify anti-HBs early response. A HBV-DNA determination by PCR was done for those who did not test positive to anti-HBs after vaccine. The level of anti-HBc was recorded as a ratio of the sample-to-cut-off values (S:C ratio) in 57 candidates at donation. Comparing true and false-positive anti-HBc results, the different S:C ratios of them were statistically significant and when less than 2, implying in a false-positive result probability over 80%. A high percent of false-positive results (16.07%) was verified after anti-HBc retesting. HBV immunity was characterized in 49.11%, either by anti-HBs detection in retesting (15.18%), or after a single dose HBV vaccination (33.93%). HBV-DNA was negative in all tested donors. In conclusion, this algorithm was useful to clarify the meaning of isolated anti-HBc in most of our blood donors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Simple and rapid latex-based diagnostic tests have been used for detecting specific antigens or antibodies in several diseases. In this article, we present the preliminary results obtained with a latex agglutination test (LAT) for diagnosing neurocysticercosis by detection of antibodies in CSF. A total of 43 CSF samples were assayed by the LAT: 19 CSF samples from patients with neurocysticercosis and 24 CSF samples from patients with other neurologic disorders (neurosyphilis, n = 8; neurotoxoplasmosis, n = 3; viral meningitis, n = 4, chronic headache, n = 9). The LAT exhibited 89.5% sensitivity and 75% specificity. The use of LAT seems to be an additional approach for the screening of neurocysticercosis with advantage of simplicity and rapidity. Further studies could be performed using purified antigens and serum samples.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The prevalence of anti-human parvovirus B19 IgG antibodies was determined in sera from 165 chronic hemolytic anemia patients, receiving medical care at Instituto Estadual de Hematologia (IEHE), Rio de Janeiro, during the year of 1994. This sample represents around 10% of the chronic hemolytic anemia patients attending at IEHE. Most of these patients (140) have sickle cell disease. Anti-B19 IgG antibodies were detected in 32.1% of patients. No statistically significant difference (p > 0.05) was seen between IgG antibody prevalence in male (27.8%) and female (35.5%) patients. Anti-B19 IgG antibodies were more frequent in older (37.6%) than younger (28.2%) than 20 years old patients, although this difference had no statistical significance (p > 0.05). Anti-B19 IgG antibody prevalence showed that 67.9% of patients enrolled in the study were susceptible to B19 acute infection. With the aim to detect acute B19 infection, patients follow up continued until February 1996. During this period four patients presented transient aplastic crisis due to human parvovirus B19 as confirmed by the detection of specific IgM antibodies. All four patients were younger than 20 years old, and 3 were younger than 10 years old. Three of them were sickle cell disease patients. Three of the four acute B19 infection occurred during 1994 springtime.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Serological survey was performed to detect IgG antibodies anti-Taenia solium metacestodes in blood donors of Hemocentro Regional de Uberlândia, Minas Gerais, Brazil. A total of 1133 sera from blood donors coming from four cities of Triângulo Mineiro area were analyzed by the indirect fluorescence antibody test (IFAT) and the enzyme linked immunosorbent assay (ELISA). Specific IgG antibodies were found in 5.6% of the studied population, showing differences in the positive rates according to their origin: Araguari (13.5%), Tupaciguara (5.0%), Monte Alegre de Minas (4.8%) and Uberlândia (4.7%). The results indicate the probable endemicity of cysticercosis in this population.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work proposes a novel approach for a suitable orientation of antibodies (Ab) on an immunosensing platform, applied here to the determination of 8-hydroxy-2′-deoxyguanosine (8OHdG), a biomarker of oxidative stress that has been associated to chronic diseases, such as cancer. The anti-8OHdG was bound to an amine modified gold support through its Fc region after activation of its carboxylic functions. Non-oriented approaches of Ab binding to the platform were tested in parallel, in order to show that the presented methodology favored Ab/Ag affinity and immunodetection of the antigen. The immunosensor design was evaluated by quartz-crystal microbalance with dissipation, atomic force microscopy, electrochemical impedance spectroscopy (EIS) and square-wave voltammetry. EIS was also a suitable technique to follow the analytical behavior of the device against 8OHdG. The affinity binding between 8OHdG and the antibody immobilized in the gold modified platform increased the charge transfer resistance across the electrochemical set-up. The observed behavior was linear from 0.02 to 7.0 ng/mL of 8OHdG concentrations. The interference from glucose, urea and creatinine was found negligible. An attempt of application to synthetic samples was also successfully conducted. Overall, the presented approach enabled the production of suitably oriented Abs over a gold platform by means of a much simpler process than other oriented-Ab binding approaches described in the literature, as far as we know, and was successful in terms of analytical features and sample application.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work proposes a novel approach for a suitable orientation of antibodies (Ab) on an immunosensing platform, applied here to the determination of 8-hydroxy-2’-deoxyguanosine (8OHdG), a biomarker of oxidative stress that has been associated to chronic diseases, such as cancer. The Anti-8OHdG was bound to an amine modified gold support through its Fc region after activation of its carboxylic functions. Non-oriented approaches of Ab binding to the platform were tested in parallel, in order to show that the presented proposal favored Ab/Ag affinity. The immunosensor design was evaluated by Quartz-Crystal microbalance with Dissipation, Atomic Force Microscopy, Electrochemical Impedance Spectroscopy (EIS) and Square-Wave Voltammetry. EIS was also a suitable technique to follow the analytical behavior of the device against 8OHdG. The affinity binding between 8OHdG and the antibody immobilized in the gold modified platform increased the charged transfer resistance across the electrochemical sep-up. The observed behavior was linear from 0.02 to 7.0 ng/mL of 8OHdG concentrations. The interference from Glucose, Urea and Creatinine was found negligible. An attempt of application to synthetic samples was also successfully conducted. Overall, the presented approach enabled the production of suitably oriented Abs over a gold platform by means of a much simpler process than other oriented-Ab binding approaches described in the literature, as far as we know, and was successful in terms of analytical features and sample application.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A rapid test based on an immunochromatography assay - Determine™ Syphilis TP (Abbott Lab.) for detecting specific antibodies to Treponema pallidum was evaluated against serum samples from patients with clinical, epidemiological and serological diagnosis of syphilis, patients with sexually transmitted disease other than syphilis, and individuals with negative serology for syphilis. The Determine™ test presented the sensitivity of 93.6%, specificity of 92.5%, and positive predictive value and negative predictive value of 95.2% and 93.7%, respectively. One serum sample from patient with recent latent syphilis showed a prozone reaction. Determine™ is a rapid assay, highly specific and easy to perform. This technique obviates the need of equipment and its diagnostic features demonstrate that it may be applicable as an alternative assay for syphilis screening under some emergency conditions or for patients living in remote localities.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In a transversal study on a sample of 386 children and adolescents from an outpatient clinic for filariasis in Recife, Northeast Brazil, the frequency of anti-Toxocara antibodies and its relation to age, gender, number of peripheral eosinophils, Wuchereria bancrofti microfilariae and intestinal helminths was determined. The total anti-Toxocara IgG antibody frequency was 39.4%, by ELISA technique. The difference in frequency between males (40.1%) and females (37.6%) was not statistically significant. The 6 to 10-year-old subset presented the highest frequency of anti-Toxocara antibodies (60%), and within this age group there was a statistically significant male bias. There was also a significant association between the number of eosinophils and the presence of anti-Toxocara antibodies. Intestinal parasite frequency was 52.1%, but no association was found between this data and the presence of anti-Toxocara antibodies. In the present sample, 42.2% of the patients were Wuchereria bancrofti carriers, however, again this was not associated with the presence of anti-Toxocara antibodies. In conclusion, anti-Toxocara antibodies were highly prevalent in this sample. The present data show that there is no cross correlation between anti-Toxocara IgG antibody and the presence of intestinal helminths and filariasis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A total of 354 serum samples from inhabitants who frequent the Clinical Laboratory in Catalão, Goiás, in the central-western region of Brazil, were collected from June to August, 2002. The samples were evaluated by indirect immunofluorescence antibody tests and an enzyme linked immunosorbent assay in order to detect anti-Taenia solium metacestode IgG antibodies. Reactive and inconclusive samples were tested by Western blotting (WB). Considering WB as a confirmation, the frequency of antibodies in the serum samples of the above population was 11.3% (CI 5.09 - 17.51). The immunodominant bands most frequently recognized in WB were 64-68 kDa (97.5%) and 47-52 kDa (80%). The percentage of seropositivity to cysticercosis was significantly higher for individuals residing in areas without sewage systems (p < 0.0001). In conclusion, the results indicate a probable endemic situation of cysticercosis in this population. These results reinforce the urgent need for control and prevention measures to be taken by the local public health services.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Prospective testing for posttransplant circulating anti-HLA antibodies seems to be a critical noninvasive tool, but confirmatory data are lacking. MATERIALS AND METHODS: Over the last 3 years, peritubular capillary (PTC) C4d deposition was prospectively sought by an immunofluorescence technique applied to frozen tissue in biopsies obtained for allograft dysfunction. Screening for circulating anti-HLA class I/II alloantibodies (AlloAb) by the flow cytometric test was performed simultaneously. RESULTS: We evaluated 132 sets of biopsies and simultaneous serum samples. PTC C4d deposition was demonstrated in 15.9% (21/132) of biopsies. Circulating anti-HLA I/II AlloAb were detected in 25% (33/132) of serum samples. Employing receiver-operator characteristic (ROC) curves for all C4d-positive biopsies, screening for AlloAb showed a global specificity of 82% and sensitivity of 61.9%. When this analysis was restricted to biopsies obtained in the first month posttransplantation, the sensitivity increased to 81.8%, but the specificity decreased to 76.9%. After the first month posttransplantation, we observed sensitivity of 40.0% and a specificity of 86.4%. In the first month posttransplantation, all patients with a diagnosis of acute antibody-mediated rejection displayed circulating anti-HLA class I/II, but not always at the same time as the C4d-positive biopsy. CONCLUSIONS: In the first month posttransplantation, prospective monitoring of anti-HLA antibodies may be useful. The high sensitivity allows the identification of patients at risk, affording an earlier diagnosis of antibody-mediated rejection. After the first month, the test can be used to evaluate allograft dysfunction episodes, since positivity is highly suggestive of an antibody-mediated process.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim: To characterise clinically the patients with C4d in peritubular capillaries deposits (C4dPTCD) and/or circulating anti-HLA class I/II alloantibodies. To determine the correlation between positive C4dPTCD and circulating anti-HLA class I/II alloantibodies during episodes of graft dysfunction. Subjects and Methods: C4d staining was performed in biopsies with available frozen tissue obtained between January 2004 and December 2006. The study was prospective from March 2005, when a serum sample was obtained at the time of biopsy to detect circulating anti-HLA class I/II alloantibodies. Results: We studied 109 biopsies in 86 cadaver renal transplant patients. Sixteen of these (14.7%) presented diffuse positive C4dPTCD. There was a 13.5% rate of +C4dPTCD incidence within the first six months of transplantation and 16% after six months (p>0.05). Half of the +C4dPTCD in the first six months was associated with acute humoral rejection. After six months, the majority of +C4dPTCD (n=7/8) was present in biopsies with evidence of interstitial fibrosis/tubular atrophy and/or transplant glomerulopathy. The C4dPTCD was more frequent in patients with positive anti-HCV antibodies(p<0.0001), a previous renal transplant (p=0.007), and with a panel reactivity antibody (PRA) ≥ 50%(p=0.0098). The anti-HCV+ patients had longer time on dialysis (p=0.0019) and higher PRA(p=0.005). Circulating anti-HLA I/II alloantibodies were screened in 46 serum samples. They were positive in 10.9% of samples, all obtained after six months post transplant. Circulating alloantibodies were absent in 92.5% of the C4d negative biopsies. Conclusion: We found an association between the presence of C4dPTCD and 2nd transplant recipients,higher PRA and the presence of anti-HCV antibodies. The presence of HCV antibodies is not a risk factor for C4dPTCD per se, but appears to reflect longer time on dialysis and presensitisation. In renal dysfunction a negative alloantibody screening is associated with a reduced risk of C4dPTCD (<10%).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The immune response expressed by IgG antibodies in BALB/c mice experimentally infected with Toxocara canis, was studied with the aim of verifying the possible in vivo cross-reactivity between antigens of T. canis and other parasites (Ascaris suum, Taenia crassiceps, Schistosoma mansoni, Strongyloides venezuelensis and Toxoplasma gondii). Experiments included three groups of mice: one infected only by T. canis, another with one of the other species of parasites and a third concomitantly infected with T. canis and the other species in question. Animals were bled by orbital plexus at 23, 38 and 70 days post infection (p.i.). Sera were analyzed for anti-Toxocara antibodies by ELISA and Immunoblotting, using excretion-secretion antigens (ES), obtained from culture of third-stage larvae of T. canis. For all experiments a control group comprised by ten non-infected mice was used. Only in the case of A. suum infection, in these experimental conditions, the occurrence of cross-reactivity with T. canis was observed. However, in the case of co-infection of T. canis - S. mansoni, T. canis - S. venezuelensis and T. canis - T. crassiceps the production of anti-Toxocara antibodies was found at levels significantly lower than those found in mice infected with T. canis only. Co-infection with S. mansoni or S. venezuelensis showed lower mortality rates compared to what occurred in the animals with single infections. Results obtained in mice infected with T. canis and T. gondii showed significant differences between the mean levels of the optical densities of animals infected with T. canis and concomitantly infected with the protozoan only in the 23rd day p.i.