912 resultados para analytical method
Resumo:
International audience
Resumo:
Dissertação (mestrado)—Universidade de Brasília, Instituto de Química, 2016.
Resumo:
An accurate and easy method for the extraction, cleanup, and HRGC-HRMS analysis of dioxin-like PCBs (DL-PCBs) in low-volume serum samples (1 mL) was developed. Serum samples were extracted several times using n-hexane and purified by acid washing. Recovery rates of labeled congeners ranged from 70 to 110 % and the limits of detection were below 1 pg/g on lipid basis. Although human studies are limited and contradictory, several studies have shown that DL-PCBs can have adverse effects on the male reproductive system. In this way, the present method was applied to 21 serum samples of male patients attending fertility clinics. The total levels obtained for the patients ranged from 6.90 to 84.1 pg WHO-TEQ/g lipid, with a mean value of 20.3 pg WHO-TEQ/g lipid. The predominant PCBs (the sum of PCB 118, 156, and 105) contributed 67 % to the mean concentration of total DL-PCBs in the samples analyzed.
Resumo:
The Potengi river estuary is located in the region of Natal (RN, Brazil), comprising a population of approximately 1,000,000 inhabitants. Besides the dominant urban presence, the estuary has fragments of mangrove forest. The objective of this study is to determine the aliphatic hydrocarbons found in the bottom sediments of this estuary, identifying their levels, distribution and their possible origins through the diagnostic rates, indexes and results comparisons with the local anthropic and natural characteristics. The samples were obtained according to a plan that allowed sampling of the estuary up to 12 km upstream from it as mounth. 36 stations were selected, grouped into 12 cross sections through the course of the river and spaced on average by 1 km. Each section consisted of three stations: the right margin, the deepest point and the left margin. The hydrocarbon n-alkanes from C10 to C36, the isoprenoids pristane and phytane, the unresolved complex mixture (UCM) and the total resolved hydrocarbons were analyzed by gas chromatography. N-alkanes, pristane, phytane and UCM were detected only at some stations. In the other, the concentration was below the detection limit defined by the analytical method (0.1 mg / kg), preventing them from being analyzed to determine the origin of the material found. By using different parameters, the results show that the estuary receives both the input of petrogenic hydrocarbons, but also of biogenic hydrocarbons, featuring a mixture of sources and relatively impacted portions. Based on the characteristics and activities found in the region, it is possible to affirm that petrogenic sources related to oil products enter the estuary via urban runoff or boats traffic, boat washing and fueling. Turning to the biogenic source, the predominant origin was terrestrial, characterized by vascular plants, indicating contribution of mangrove vegetation. It was evident the presence of, at specific points in the estuary, hydrocarbon pollution, and, therefore is recommended the adoption of actions aimed at interrupting or, at least, mitigating the sources potentially capable of damp petrogenic hydrocarbons in the estuary studied.
Resumo:
Gunshot residue (GSR) is the term used to describe the particles originating from different parts of the firearm and ammunition during the discharge. A fast and practical field tool to detect the presence of GSR can assist law enforcement in the accurate identification of subjects. A novel field sampling device is presented for the first time for the fast detection and quantitation of volatile organic compounds (VOCs). The capillary microextraction of volatiles (CMV) is a headspace sampling technique that provides fast results (< 2 min. sampling time) and is reported as a versatile and high-efficiency sampling tool. The CMV device can be coupled to a Gas Chromatography-Mass Spectrometry (GC-MS) instrument by installation of a thermal separation probe in the injection port of the GC. An analytical method using the CMV device was developed for the detection of 17 compounds commonly found in polluted environments. The acceptability of the CMV as a field sampling method for the detection of VOCs is demonstrated by following the criteria established by the Environmental Protection Agency (EPA) compendium method TO-17. The CMV device was used, for the first time, for the detection of VOCs on swabs from the hands of shooters, and non-shooters and spent cartridges from different types of ammunition (i.e., pistol, rifle, and shotgun). The proposed method consists in the headspace extraction of VOCs in smokeless powders present in the propellant of ammunition. The sensitivity of this method was demonstrated with method detection limits (MDLs) 4-26 ng for diphenylamine (DPA), nitroglycerine (NG), 2,4-dinitrotoluene (2,4-DNT), and ethyl centralite (EC). In addition, a fast method was developed for the detection of the inorganic components (i.e., Ba, Pb, and Sb) characteristic of GSR presence by Laser Induced Breakdown Spectroscopy (LIBS). Advantages of LIBS include fast analysis (~ 12 seconds per sample) and good sensitivity, with expected MDLs in the range of 0.1-20 ng for target elements. Statistical analysis of the results using both techniques was performed to determine any correlation between the variables analyzed. This work demonstrates that the information collected from the analysis of organic components has the potential to improve the detection of GSR.
Resumo:
In the scope of the discussions about microgeneration (and microgrids), the avoided electrical losses are often pointed out as an important value to be credited to those entities. Therefore, methods to assess the impact of microgeneration on losses must be developed in order to support the definition of a suitable regulatory framework for the economic integration of microgeneration on distribution networks. This paper presents an analytical method to quantify the value of avoided losses that microgeneration may produce on LV networks. Intervals of expected avoided losses are used to account for the variation of avoided losses due to the number, size and location of microgenerators, as well as for the kind of load distribution on LV networks.
Resumo:
Dans le département des Pyrénées orientales, nombreux sont ceux qui apprennent le catalan, langue régionale aux côtés du français. Cet espace géographique plurilingue se rattache à l’entité plus vaste de la Catalogne, berceau de conflits diglossique virulents, au coeur de revendications d’autonomie qui secouent le climat politique actuel en Espagne. Cet article rend compte d’une enquête réalisée dans le cadre du projet «Représentations des langues et des identités en Méditerranée en contexte plurilingue» (EA 739 Dipralang). Il s’agit de mettre en évidence les représentations du catalan et du français chez les apprenants de catalan, qu’ils soient locuteurs natifs, étudiants à l’université, dans les filières spécifiques ou comme option, ou encore qu’ils se destinent à l’enseigner dans les classes bilingues. Nous faisons l’hypothèse que ces représentations diffèrent en fonction de l’implication dans la diglossie français-catalan et qu’elles sont un écho au conflit linguistique propre à la Catalogne. Pour la vérifier, nous utilisons la méthode d’analyse combinée mise au point par Bruno Maurer.
Resumo:
O atenolol é um fármaco β-bloqueador normalmente encontrado em águas residuais devido à incapacidade que os processos convencionais de tratamento destas águas têm em removê-lo. Neste trabalho foram utilizados microcosmos de leitos construídos de macrófitas de fluxo sub-superficial utilizando uma matriz de argila expandida (LECA) e plantados com Phragmites australis para avaliar a sua capacidade em remover atenolol das águas residuais. Para a detecção e quantificação do atenolol em soluções aquosas (águas e efluentes) desenvolveu-se e optimizou-se uma metodologia analítica usando separação cromatográfica por HPLC e detecção espectrofotométrica por diode array (HPLC-DAD) ou por ultravioleta visível (HPLC-UV-Vis). Desenvolveu-se também um procedimento de limpeza e concentração de amostra por extracção em fase sólida (SPE), o qual foi utilizado sempre que as concentrações do analito se encontraram abaixo dos limites de quantificação do equipamento. A utilização desta metodologia de HPLC, combinada com uma eficaz pré-concentração por SPE, resultou num método analítico com um limite de quantificação muito reduzido (9 ngmL-1) e elevada reprodutibilidade (RSD<4%). A eficiência de remoção de atenolol pelos sistemas de macrófitas estudados foi de 93% após um tempo de retenção de 4 dias. Foram testados leitos só com LECA e com LECA e plantas para remoção do atenolol. Nos leitos só com LECA, a cinética de remoção foi caracterizada por um rápido passo inicial (uma remoção de aproximadamente 75% após apenas 24 h), o qual é frequentemente atribuído à adsorção na matriz de LECA. A remoção de atenolol nos leitos de LECA continuou a aumentar de forma constante até ao final do ensaio (8 dias), sendo, contudo cerca de 5-10% mais baixo do que o valor observado nos leitos das plantas após os 4 primeiros dias. Para o tempo de retenção de 4 dias a maioria do atenolol é removido pela matriz de LECA, porém um acréscimo de cerca de 12-14% relativamente à eficiência de remoção global pode ser atribuído às plantas (Phragmites australis), o que está de acordo com trabalhos anteriormente publicados. Apesar de ser necessário realizar mais testes utilizando sistemas em larga escala, de modo a conseguir avaliar totalmente o comportamento do atenolol num sistema de leitos construídos de macrófitas, o presente estudo apresenta a possibilidade de aplicar este tipo de sistemas, relativamente baratos, no tratamento de águas residuais contaminadas com atenolol. ABSTRACT: Atenolol is a β-blocker drug commonly found in wastewaters due to the inability of the conventional wastewater treatment processes to remove it. ln this study, subsurface flow constructed wetland microscosm systems have been established with a matrix of light expanded clay aggregates (LECA) and planted with Phragmites australis in order to evaluate their ability to remove atenolol from wastewater. For the detection and quantification of atenolol in aqueous solutions (water and wastewater), an adequate analytical methodology was developed and optimized using chromatographic separation by HPLC and diode array (DAD) or UV-Vis spectrophotometric detection. A sample clean-up and preconcentration procedure by solid phase extraction (SPE) was also developed for use whenever the concentration levels of the analyte were below the instrument's limit of quantification. Combined with an efficient SPE concentration step, the use of HPLC yielded an analytical method for atenolol quantification with very low LOQ (9 ngmL-1) and high reproducibility (RSD< 4%). Overall atenolol removal efficiency of 93% was achieved after a retention time of only 4 days with the microcosm systems planted with Phragmites australis. The removal kinetics was characterized by an initial fast step (removal of about 75% after just 24h) which is mainly attributable to adsorption on the LECA matrix. Atenolol removal in LECA beds continues to increase in a steady pace up to the end of the assay (8 days) being nevertheless about 5-l 0% lower than those observed in the planted beds after the first 4 days. For the retention time of 4 days most of the atenolol is removed by the LECA matrix but an additional 12-14% to the overall removal efficiency can be attributed to the Phragmites plants, which comes in agreement with other published reports. Despite the fact that further tests using larger scale systems are required to fully evaluate the atenolol behavior in a constructed wetland system, this study points out to the possible application of these low-cost wastewater systems to treat atenolol contaminated wastewater.
Resumo:
A ocorrência e destino de fármacos no ambiente aquático tem vindo a ser reconhecido como um problema emergente em química ambiental. Alguns compostos são resistentes à degradação nas estações de tratamento de águas residuais, ETARs, enquanto que outros, ainda que sofram degradação parcial, continuam a ser lançados nos meios aquáticos em quantidades apreciáveis. O Ibuprofeno, IB, um dos anti inflamatórios mais consumidos por todo o mundo, é um dos fármacos mais detectados no meio hídrico. Apesar dos sistemas de tratamento convencionais utilizados nas ETARs removerem até 90% do IB das águas residuais, é frequente o efluente descarregado conter ainda quantidades significativas deste poluente. A presença destes compostos no ambiente deve ser avaliada dado que possuem actividade biológica, mesmo a baixas concentrações. Os processos avançados de oxidação com peróxido de hidrogénio, na presença de catalisadores heterogéneos, permitem melhorar significativamente a remoção deste tipo de compostos em águas. Assim, foi objectivo deste trabalho o estudo da utilização de peróxido de hidrogénio como agente oxidante na remoção de IB em soluções aquosas, na presença de complexo de acetilacetonato de Ni (II) disperso em PDMS ou encapsulado em zeólitos NaY. Para o doseamento do fármaco em solução foi necessário desenvolver um método analítico consistindo de separação cromatográfica por HPLC e detecção e quantificação por UV-Vis. Não houve necessidade de recorrer a um passo de pré concentração de amostras por extracção em fase sólida (SPE) devido ao facto das concentrações de IB medidas ao longo do trabalho se terem sempre encontrado acima do LOQ (811 g L-1) do método analítico por injecção directa. Deste estudo pode concluir-se que o catalisador que apresentou melhor actividade catalítica e consequentemente maior remoção do IB em solução, foi o complexo de acetilacetonato de Ni (II), disperso em PDMS. Foi avaliada a influência, na conversão do IB, de diferentes parâmetros como a concentração inicial de peróxido de hidrogénio adicionada, quantidade de catalisador utilizada na mistura reaccional e temperatura. Os resultados permitiram concluir que os aumentos destes parâmetros conduzem a um aumento da actividade catalítica da reacção. A estabilidade catalítica do acetilacetonato de Ni (II)/PDMS, foi avaliada em ensaios consecutivos com a mesma amostra e nas mesmas condições, tendo-se observado que, após 8 utilizações, o catalisador perde ligeiramente a actividade (cerca de 11% do seu valor inicial). ABSTRACT: The presence and fate of pharmaceuticals in the aquatic environment is an emergent issue in environmental chemistry. Some compounds are poorly removed in wastewater treatment plants (WWTPs) while others, in spite of being partially removed, are still present in the WWTPs effluents and discharged in the receiving water bodies. Ibuprofen, IB, a non-steroid anti-inflammatory drug, is one of the most used and also one of the most frequently detected pharmaceutical contaminants in aquifers worldwide. Its removal by conventional wastewater treatment processes used in most WWTPs is usually high (up to 90% of incoming IB may be removed), but duet the high loads present in the influents, still significant amounts of IB usually leave the WWTPs in the treated effluents. The presence of these compounds in the environment must be evaluated considering that they may have some biological activity even at low concentrations. Advanced oxidation processes using hydrogen peroxide, in the presence of heterogeneous catalysts, provide a significantly improved removal of this type of substances from waters. Therefore, it was the aim of this work to study the use of hydrogen peroxide as an oxidizing agent in the removal of IB from aqueous solutions, in the presence of the catalyst nickel (II) acetylacetonate dispersed in PDMS or encapsulated in the NaY zeolite. For the quantification of the pharmaceutical in aqueous solution it was necessary to develop an analytical methodology based in chromatographic separation by HPLC and with UV-Vis detection and quantification. There was no need for a preconcentration step of the samples by solid phase extraction (SPE) as the IB concentrations measured were always above the limit of quantification (811 bL1 of) the analytical method. The results from this study have shown that the catalyst which presented the best catalytic activity and the highest IB removal in solution was nickel (II) acetylacetonate dispersed in PDMS.
Resumo:
In this paper, we consider a modified anomalous subdiffusion equation with a nonlinear source term for describing processes that become less anomalous as time progresses by the inclusion of a second fractional time derivative acting on the diffusion term. A new implicit difference method is constructed. The stability and convergence are discussed using a new energy method. Finally, some numerical examples are given. The numerical results demonstrate the effectiveness of theoretical analysis
Analytical Solution for the Time-Fractional Telegraph Equation by the Method of Separating Variables
Resumo:
In this paper, a method of separating variables is effectively implemented for solving a time-fractional telegraph equation (TFTE) in two and three dimensions. We discuss and derive the analytical solution of the TFTE in two and three dimensions with nonhomogeneous Dirichlet boundary condition. This method can be extended to other kinds of the boundary conditions.
Resumo:
We present an analytical field-effect method to extract the density of subgap states (subgap DOS) in amorphous semiconductor thin-film transistors (TFTs), using a closed-form relationship between surface potential and gate voltage. By accounting the interface states in the subthreshold characteristics, the subgap DOS is retrieved, leading to a reasonably accurate description of field-effect mobility and its gate voltage dependence. The method proposed here is very useful not only in extracting device performance but also in physically based compact TFT modeling for circuit simulation.
Resumo:
We present an analytical field-effect method to extract the density of subgap states (subgap DOS) in amorphous semiconductor thin-film transistors (TFTs), using a closed-form relationship between surface potential and gate voltage. By accounting the interface states in the subthreshold characteristics, the subgap DOS is retrieved, leading to a reasonably accurate description of field-effect mobility and its gate voltage dependence. The method proposed here is very useful not only in extracting device performance but also in physically based compact TFT modeling for circuit simulation. © 2012 IEEE.