970 resultados para Weaning mechanical ventilation


Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To assess the suitability of a hot-wire anemometer infant monitoring system (Florian, Acutronic Medical Systems AG, Hirzel, Switzerland) for measuring flow and tidal volume (Vt) proximal to the endotracheal tube during high-frequency oscillatory ventilation. DESIGN: In vitro model study. SETTING: Respiratory research laboratory. SUBJECT: In vitro lung model simulating moderate to severe respiratory distress. INTERVENTION: The lung model was ventilated with a SensorMedics 3100A ventilator. Vt was recorded from the monitor display (Vt-disp) and compared with the gold standard (Vt-adiab), which was calculated using the adiabatic gas equation from pressure changes inside the model. MEASUREMENTS AND MAIN RESULTS: A range of Vt (1-10 mL), frequencies (5-15 Hz), pressure amplitudes (10-90 cm H2O), inspiratory times (30% to 50%), and Fio2 (0.21-1.0) was used. Accuracy was determined by using modified Bland-Altman plots (95% limits of agreement). An exponential decrease in Vt was observed with increasing oscillatory frequency. Mean DeltaVt-disp was 0.6 mL (limits of agreement, -1.0 to 2.1) with a linear frequency dependence. Mean DeltaVt-disp was -0.2 mL (limits of agreement, -0.5 to 0.1) with increasing pressure amplitude and -0.2 mL (limits of agreement, -0.3 to -0.1) with increasing inspiratory time. Humidity and heating did not affect error, whereas increasing Fio2 from 0.21 to 1.0 increased mean error by 6.3% (+/-2.5%). CONCLUSIONS: The Florian infant hot-wire flowmeter and monitoring system provides reliable measurements of Vt at the airway opening during high-frequency oscillatory ventilation when employed at frequencies of 8-13 Hz. The bedside application could improve monitoring of patients receiving high-frequency oscillatory ventilation, favor a better understanding of the physiologic consequences of different high-frequency oscillatory ventilation strategies, and therefore optimize treatment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION. A two-step assessment (readiness to wean (RW) followed by spontaneousbreathing trial (SBT)) of predefined criteria is recommended before planned extubation(PE)1.OBJECTIVES. We aimed to evaluate if compliance to all guideline criteria was associatedwith better respiratory outcome within 48 h after PE.METHODS. The data (extracted from our clinical information system) of 458 consecutivepatients who underwent PE after C48 h of invasive ventilation in our medico-surgical ICUwere analyzed. We evaluated compliance with guidelines [1] regarding respiratory rate, tidalvolume, PaO2, FiO2, PEEP, PaCO2, pH, heart rate, systolic arterial pressure and arrhythmiaduringRWand SBT assessment (RW and SBT within 2 h). A patient was classified as RW+ ifallRWcriteria were fulfilled andRW-if at least 1 criterion was violated. The same approachwas used to define SBT+ and SBT- patients. During the 48 h following PE, we assessed theoccurrence of post-PE respiratory failure (PRF) (defined as the presence of at least 1 consensuscriterion of respiratory failure [1]), reintubation (after NIV failure or because of immediateintubation criteria) and cumulative duration of post-PE ventilation (PPEV = Post-PE invasive+ non-invasive ventilation). ICU mortality was recorded. Comparisons for variousoutcomes were performed by Chi-square and t tests.RESULTS. All consensus criteria were fulfilled in 77.3% of the patients during RW and in68.1% of the patients during SBT.[Compliance to weaning criteria and outcome]N = 458 PRF (%) Reintubation (%) PPEV (min) ICU mortality (%)All patients 53.5 10.0 542 ± 664 6.1RW+ 50.0 9.3 490 ± 626 5.4RW- 65.4* 12.5 718 ± 757** 8.7SBT+ 52.6 8.0 498 ± 594 6.7SBT- 55.5 14.4*** 637 ± 788**** 4.8Occurrence of PRF only was not associated with increased ICU mortality: 4.2 versus 7.8%,p = 0.11. By contrast, ICU mortality was significantly increased in patients requiring reintubation:21.7 versus 4.4%. p\0.001; * p = 0.006 RW+ versus RW-; ** p = 0.003RW+ versus RW-; *** p = 0.035 SBT+ versus SBT-; **** p = 0.030 SBT+ versusSBTCONCLUSIONS.In our ICU, compliance to all criteria of the two-step published approach ofrespiratory weaning was not optimal but reintubation rate was comparable to published data.Compliance with consensus conference guidelines was associated with lower reintubation rateand shorter PPEV but not with ICU mortality. As mortality was increased by reintubation,more sensitive and specific criteria to predict the risk of reintubation are probably needed.REFERENCE. Boles JM, et al. Eur Respir J 2007;29:1033-56.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Spontaneous ventilation, mechanical controlled ventilation, apneic intermittent ventilation, and jet ventilation are commonly used during interventional suspension microlaryngoscopy. The aim of this study was to investigate specific complications of each technique, with special emphasis on transtracheal and transglottal jet ventilation. METHODS: The authors performed a retrospective single-institution analysis of a case series of 1,093 microlaryngoscopies performed in 661 patients between January 1994 and January 2004. Data were collected from two separate prospective databases. Feasibility and complications encountered with each technique of ventilation were analyzed as main outcome measures. RESULTS: During 1,093 suspension microlaryngoscopies, ventilation was supplied by mechanical controlled ventilation via small endotracheal tubes (n = 200), intermittent apneic ventilation (n = 159), transtracheal jet ventilation (n = 265), or transglottal jet ventilation (n = 469). Twenty-nine minor and 4 major complications occurred. Seventy-five percent of the patients with major events had an American Society of Anesthesiologists physical status classification of III. Five laryngospasms were observed with apneic intermittent ventilation. All other 24 complications (including 7 barotrauma) occurred during jet ventilation. Transtracheal jet ventilation was associated with a significantly higher complication rate than transglottal jet ventilation (P < 0.0001; odds ratio, 4.3 [95% confidence interval, 1.9-10.0]). All severe complications were related to barotraumas resulting from airway outflow obstruction during jet ventilation, most often laryngospasms. CONCLUSIONS: The use of a transtracheal cannula was the major independent risk factor for complications during jet ventilation for interventional microlaryngoscopy. The anesthetist's vigilance in clinically detecting and preventing outflow airway obstruction remains the best prevention of barotrauma during subglottic jet ventilation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Current bilevel positive-pressure ventilators for home noninvasive ventilation (NIV) provide physicians with software that records items important for patient monitoring, such as compliance, tidal volume (Vt), and leaks. However, to our knowledge, the validity of this information has not yet been independently assessed. METHODS: Testing was done for seven home ventilators on a bench model adapted to simulate NIV and generate unintentional leaks (ie, other than of the mask exhalation valve). Five levels of leaks were simulated using a computer-driven solenoid valve (0-60 L/min) at different levels of inspiratory pressure (15 and 25 cm H(2)O) and at a fixed expiratory pressure (5 cm H(2)O), for a total of 10 conditions. Bench data were compared with results retrieved from ventilator software for leaks and Vt. RESULTS: For assessing leaks, three of the devices tested were highly reliable, with a small bias (0.3-0.9 L/min), narrow limits of agreement (LA), and high correlations (R(2), 0.993-0.997) when comparing ventilator software and bench results; conversely, for four ventilators, bias ranged from -6.0 L/min to -25.9 L/min, exceeding -10 L/min for two devices, with wide LA and lower correlations (R(2), 0.70-0.98). Bias for leaks increased markedly with the importance of leaks in three devices. Vt was underestimated by all devices, and bias (range, 66-236 mL) increased with higher insufflation pressures. Only two devices had a bias < 100 mL, with all testing conditions considered. CONCLUSIONS: Physicians monitoring patients who use home ventilation must be aware of differences in the estimation of leaks and Vt by ventilator software. Also, leaks are reported in different ways according to the device used.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article addresses the need for providing good standards of indoor air quality (IAQ) in buildings from the view point of health, well-being and productivity of building occupants. It briefly outlines the role of ventilation in achieving the required IAQ targets and discusses the performance of different types of ventilation systems in use. As a result of new energy efficiency directives and legislations in Europe and elsewhere, the ventilation energy component of HVAC systems has increased in relative terms and this article introduces a method for evaluating the performance air distribution systems that is based on ventilation and energy effectiveness. A range of ventilation systems are discussed, including mechanical and natural ventilation, and results for more recently developed mechanical air distribution systems are compared with conventional systems. The article provides an assessment and comparison of some of these systems with reference to ventilation performance and energy efficiency

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Pediatria - FMB

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To investigate the use of nasal intermittent positive pressure ventilation (NIPPV) in level three neonatal intensive care units (NICU) in northeastern Brazil. Methods: This observational cross-sectional survey was conducted from March 2009 to January 2010 in all level three NICUs in northeastern Brazil that are registered in the Brazilian Registry of Health Establishments (Cadastro Nacional de Estabelecimentos de Saude, CNES) of the Ministry of Health. Questionnaires about the use of NIPPV were sent to the NICU directors in each institution. Statistical analysis was conducted using the software Epi-Info 6.04 and double data entry. A chi-square test was used to compare variables, and the level of statistical significance was set at p <= 0.05. Results: This study identified 93 level three NICUs in northeastern Brazil registered in CNES, and 87% answered the study questionnaire. Most classified themselves as private institutions (30.7%); 98.7% used NIPPV; 92.8 % adapted mechanical ventilators for NIPPV and used short binasal prongs as the interface (94.2%). Only 17.3% of the units had a protocol for the use of NIPPV. Mean positive inspiratory pressure and positive end-expiratory pressure were 20.0 cmH(2)O (standard deviation [SD]: 4.47) and 5.0 cmH(2)O (SD: 0.84). Conclusion: NICUs in northeastern Brazil use nasal intermittent positive pressure ventilation, but indications and ventilation settings are not the same in the different institutions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The real utilisation scenario of non-invasive ventilation (NIV) in Swiss ICUs has never been reported. Using a survey methodology, we developed a questionnaire sent to the directors of the 79 adult ICUs to identify the perceived pattern of NIV utilisation. We obtained a response rate of 62%. The overall utilisation rate for NIV was 26% of all mechanical ventilations, but we found significant differences in the utilisation rates among different linguistic areas, ranging from 20% in the German part to 48% in the French part (p <0.01). NIV was mainly indicated for the acute exacerbations of COPD (AeCOPD), acute cardiogenic pulmonary edema (ACPE) and acute respiratory failure (ARF) in selected do-not-intubate patients. In ACPE, CPAP was much less used than bi-level ventilation and was still applied in AeCOPD. The first line interface was a facial mask (81%) and the preferred type of ventilator was an ICU machine with an NIV module (69%). The perceived use of NIV is generally high in Switzerland, but regional variations are remarkable. The indications of NIV use are in accordance with international guidelines. A high percentage of units consider selected do-not-intubate conditions as an important additional indication.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A one-year-old healthy sheep received an implant stenting the mural ('posterior') leaflet of the mitral valve. The experiment was authorized by the Cantonal Ethical Committee. The surgery was performed on the open, beating heart during cardiopulmonary bypass (CPB). Management of anaesthesia was based on isoflurane with mechanical intermittent positive pressure ventilation (IPPV) of the lungs, combined with intercostal nerve blocks and intravenous fentanyl and lidocaine. Marked cardiovascular depression occurred towards the end of CPB time and required high doses of dopamine, dobutamine, lidocaine and ephedrine to allow for weaning off the CPB pump. Moreover, severe pulmonary dysfunction developed when IPPV was re-initiated after CPB. Hypoxaemia persisted throughout the recovery from general anaesthesia. Multiple organ failure developed gradually during the three postoperative days, leading to euthanasia of the animal. As described in this case, marked lung injury associated with some degree of failure of other vital organs may occur in sheep after CPB. Intraoperative cardiorespiratory complications when weaning-off may indicate the development of 'post-pump syndrome'.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Resuscitation guidelines encourage the use of cardiopulmonary resuscitation (CPR) feedback devices implying better outcomes after sudden cardiac arrest. Whether effective continuous feedback could also be given verbally by a second rescuer ("human feedback") has not been investigated yet. We, therefore, compared the effect of human feedback to a CPR feedback device. METHODS In an open, prospective, randomised, controlled trial, we compared CPR performance of three groups of medical students in a two-rescuer scenario. Group "sCPR" was taught standard BLS without continuous feedback, serving as control. Group "mfCPR" was taught BLS with mechanical audio-visual feedback (HeartStart MRx with Q-CPR-Technology™). Group "hfCPR" was taught standard BLS with human feedback. Afterwards, 326 medical students performed two-rescuer BLS on a manikin for 8 min. CPR quality parameters, such as "effective compression ratio" (ECR: compressions with correct hand position, depth and complete decompression multiplied by flow-time fraction), and other compression, ventilation and time-related parameters were assessed for all groups. RESULTS ECR was comparable between the hfCPR and the mfCPR group (0.33 vs. 0.35, p = 0.435). The hfCPR group needed less time until starting chest compressions (2 vs. 8 s, p < 0.001) and showed fewer incorrect decompressions (26 vs. 33 %, p = 0.044). On the other hand, absolute hands-off time was higher in the hfCPR group (67 vs. 60 s, p = 0.021). CONCLUSIONS The quality of CPR with human feedback or by using a mechanical audio-visual feedback device was similar. Further studies should investigate whether extended human feedback training could further increase CPR quality at comparable costs for training.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background and objective: There are no data about the influence of anaesthetics on cardiovascular variables during pressure support ventilation of the lungs through the laryngeal mask airway. We compared propofol, sevoflurane and isoflurane for maintenance of anaesthesia with the ProSeal (R) laryngeal mask airway during pressure support ventilation. Methods: Sixty healthy adults undergoing peripheral musculo-skeletal surgery were randomized for maintenance with sevoflurane end-tidal 29%, isoflurane end-tidal 1.1% or propofol 6 mg kg(-1) h(-1) in oxygen 33% and air. Pressure support ventilation comprised positive end-expiratory pressure set at 5 cmH(2)O, and pressure support set 5 cmH(2)O above positive end-expiratory pressure. Pressure support was initiated when inspiration produced a 2 cmH(2)O reduction in airway pressure. A blinded observer recorded cardiorespiratory variables (heart rate, mean blood pressure, oxygen saturation, air-way occlusion pressure, respiratory rate, expired tidal volume, expired minute volume and end-tidal CO2), adverse events and emergence times. Results: Respiratory rate and minute volume were 10-21% lower, and end-tidal CO2 6-11% higher with the propofol group compared with the sevoflurane or isoflurane groups, but otherwise cardiorespiratory variables were similar among groups. No adverse events occurred in any group. Emergence times were longer with the propofol group compared with the sevoflurane or isoflurane groups (10 vs. 7 vs. 7 min). Conclusion: Lung ventilation is less effective and emergence times are longer with propofol than sevoflurane or isoflurane for maintenance of anaesthesia during pressure support ventilation with the ProSeal (R) laryngeal mask airway. However, these differences are small and of doubtful clinical importance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Functional electrical impedance tomography (EIT) measures relative impedance change that occurs in the chest during a distinct observation period and an EIT image describing regional relative impedance change is generated. Analysis of such an EIT image may be erroneous because it is based on an impedance signal that has several components. Most of the change in relative impedance in the chest is caused by air movement but other physiological events such as cardiac activity change in end expiratory level or pressure swings originating from a ventilator circuit can influence the impedance signal. We obtained EIT images and signals in spontaneously breathing healthy adults, in extremely prematurely born infants on continuous positive airway pressure and in ventilated sheep on conventional mechanical or high frequency oscillatory ventilation (HFOV). Data were analyzed in the frequency domain and results presented after band pass filtering within the frequency range of the physiological event of interest. Band pass filtering of EIT data is necessary in premature infants and on HFOV to differentiate and eliminate relative impedance changes caused by physiological events other than the one of interest.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Viscosupplements, used for treating joint and cartilage diseases, restore the rheological properties of synovial fluid, regulate joint homeostasis and act as scaffolds for cell growth and tissue regeneration. Most viscosupplements are hydrogels composed of hyaluronic acid (HA) microparticles suspended in fluid HA. These microparticles are crosslinked with chemicals to assure their stability against enzyme degradation and to prolong the action of the viscosupplement. However, the crosslinking also modifies the mechanical, swelling and rheological properties of the HA microparticle hydrogels, with consequences on the effectiveness of the application. The aim of this study is to correlate the crosslinking degree (CD) with these properties to achieve modulation of HA/DVS microparticles through CD control. Because divinyl sulfone (DVS) is the usual crosslinker of HA in viscosupplements, we examined the effects of CD by preparing HA microparticles at 1:1, 2:1, 3:1, and 5:1 HA/DVS mass ratios. The CD was calculated from inductively coupled plasma spectrometry data. HA microparticles were previously sized to a mean diameter of 87.5 µm. Higher CD increased the viscoelasticity and the extrusion force and reduced the swelling of the HA microparticle hydrogels, which also showed Newtonian pseudoplastic behavior and were classified as covalent weak. The hydrogels were not cytotoxic to fibroblasts according to an MTT (3-[4,5-dimethylthiazol-2-yl]-2,5-diphenyltetrazolium bromide) assay. © 2014 Wiley Periodicals, Inc. J Biomed Mater Res Part A, 2014.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to use mechanical and photoelastic tests to compare the performance of cannulated screws with other fixation methods in mandibular symphysis fractures. Ten polyurethane mandibles were allocated to each group and fixed as follows: group PRP, 2 perpendicular miniplates; group PLL, 1 miniplate and 1 plate, parallel; and group CS, 2 cannulated screws. Vertical linear loading tests were performed. The differences between mean values were analyzed with the Tukey test. The photoelastic test was carried out using a polariscope. The results revealed differences between the CS and PRP groups at 1, 3, 5, and 10 millimeters of displacement. The photoelastic test confirmed higher stress concentration in all groups close to the mandibular base, whereas the CS group showed it throughout the region assessed. Conical cannulated screws performed well in mechanical and photoelastic tests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

P2X7 receptors play an important role in inflammatory hyperalgesia, but the mechanisms involved in their hyperalgesic role are not completely understood. In this study, we hypothesized that P2X7 receptor activation induces mechanical hyperalgesia via the inflammatory mediators bradykinin, sympathomimetic amines, prostaglandin E2 (PGE2), and pro-inflammatory cytokines and via neutrophil migration in rats. We found that 2'(3')-O-(4-benzoylbenzoyl)adenosine 5'-triphosphate triethylammonium salt (BzATP), the most potent P2X7 receptor agonist available, induced a dose-dependent mechanical hyperalgesia that was blocked by the P2X7 receptor-selective antagonist A-438079 but unaffected by the P2X1,3,2/3 receptor antagonist TNP-ATP. These findings confirm that, although BzATP also acts at both P2X1 and P2X3 receptors, BzATP-induced hyperalgesia was mediated only by P2X7 receptor activation. Co-administration of selective antagonists of bradykinin B1 (Des-Arg(8)-Leu(9)-BK (DALBK)) or B2 receptors (bradyzide), β1 (atenolol) or β2 adrenoceptors (ICI 118,551), or local pre-treatment with the cyclooxygenase inhibitor indomethacin or the nonspecific selectin inhibitor fucoidan each significantly reduced BzATP-induced mechanical hyperalgesia in the rat hind paw. BzATP also induced the release of the pro-inflammatory cytokines tumor necrosis factor α (TNF-α), interleukin (IL)-1β, IL-6 and cytokine-induced neutrophil chemoattractant-1 (CINC-1), an effect that was significantly reduced by A-438079. Co-administration of DALBK or bradyzide with BzATP significantly reduced BzATP-induced IL-1β and CINC-1 release. These results indicate that peripheral P2X7 receptor activation induces mechanical hyperalgesia via inflammatory mediators, especially bradykinin, which may contribute to pro-inflammatory cytokine release. These pro-inflammatory cytokines in turn may mediate the contributions of PGE2, sympathomimetic amines and neutrophil migration to the mechanical hyperalgesia induced by local P2X7 receptor activation.