929 resultados para Water Distribution Networks Leak Detection I
Resumo:
It may be difficult for small and medium cities to obtain information about the fluoride content of public water, because of the lack of equipments and technicians. This study aimed to analyze the fluoride levels of the water supplied by the public treatment stations of 40 cities situated in the northwest region of São Paulo State, during a period of 6 months, to verify if fluoridation occurs in a continuous manner and if the fluoride levels are within the recommended. Maps of the water distribution system were obtained from the water treatment companies and utilized to randomize the addresses of the collection sites, so that they included all regions with treated water sources. One water sample by month was collected and analyzed in duplicate using an ion-specific-electrode. Samples with 0.6 to 0.8 mgF/L were considered acceptable. In the 38 cities that regularly provided the samples in the 6 months of the study, water from 144 collection sites was collected and a total of 864 samples were analyzed, of which 61.81 percent were classified as unacceptable. It was observed that 33 cities performed fluoridation but in 78.79 percent of these cities there were variations in the fluoride level among the sites and in the same site during the period of study. One can conclude that most of these cities do not control the fluoride levels in the public water, since fluoridation occurs in a discontinuous manner and in most of the situations not within the recommended concentrations.
Resumo:
With the considerable increase of the losses in electric utilities of developing countries, such as Brazil, there is an investigation for loss calculation methodologies, considering both technical (inherent of the system) and non-technical (usually associated to the electricity theft) losses. In general, all distribution networks know the load factor, obtained by measuring parameters directly from the network. However, the loss factor, important for the energy loss cost calculation, can only be obtained in a laborious way. Consequently, several formulas have been developed for obtaining the loss factor. Generally, it is used the expression that relates both factors, through the use of a coefficient k. Last reviews introduce a range of factor k within 0.04 - 0.30. In this work, an analysis with real life load curves is presented, determining new values for the coefficient k in a Brazilian electric utility. © 2006 IEEE.
Resumo:
In this paper, an expert and interactive system for developing protection system for overhead and radial distribution feeders is proposed. In this system the protective devices can be allocated through heuristic and an optimized way. In the latter one, the placement problem is modeled as a mixed integer non-linear programming, which is solved by genetic algorithm (GA). Using information stored in a database as well as a knowledge base, the computational system is able to obtain excellent conditions of selectivity and coordination for improving the feeder reliability indices. Tests for assessment of the algorithm efficiency were carried out using a real-life 660-nodes feeder. © 2006 IEEE.
Resumo:
The need for a rational use of water and supply of food for a growing world population have led to the development of research in the area of irrigation systems. Thus, some irrigation systems which join efficiency with low cost of material have been developed. Although some technical characteristics are provided by the manufacturers, tests are required to verify functioning of the system and uniformity of water distribution. Continuous research on uniformity, characteristics of the materials and design of water distribution systems is essential for system improvement. Therefore, the objective of this work was to evaluate the CV (manufacturer's coefficient of variation) of Amanco microsprinkler (1.0 mm light green nipple) using bench testing in the laboratory of Irrigation at UNESP - FCA campus of Botucatu-SP. Twenty-five microsprinklers in a sequential design were used in the tests. Three flow systems were tested as follows: a Coil system based on serial connected pipes; a Lateral system, the most common system in which secondary lines are fed by a main line; and a Mesh system used in the urban water supply. The results showed that 4.17% CVf met the production standards and the Lateral and Mesh systems were similar regarding outflow using bench testing. The Mesh system presented the highest mean value of outflow and the lowest range of variation.
Resumo:
This paper deals with results of a research and development (R&D) project in cooperation with Electric Power Distribution Company in São Paulo (Brazil) regarding the development and experimental analysis of a new concept of power drive system suitable for application in traction systems of electrical vehicles pulled by electrical motors, which can be powered by urban DC or AC distribution networks. The proposed front-end structure is composed by five boost power cells in interleaving connection, operating in discontinuous conduction mode as AC-DC converter, or as DC-DC converter, in order to provide the proper DC output voltage range required by DC or AC adjustable speed drivers. Therefore, when supplied by single-phase AC distribution networks, and operating as AC-DC converter, it is capable to provide high power factor, reduced harmonic distortion in the input current, complying with the restrictions imposed by the IEC 61000-3-4 standards resulting in significant improvements for the trolleybuses systems efficiency and for the urban distribution network costs. Considering the compliance with input current restrictions imposed by IEC 61000-3-4 standards, two digital control strategies were evaluated. The digital controller has been implemented using a low cost FPGA (XC3S200) and developed totally using a hardware description language VHDL and fixed point arithmetic. Experimental results from a 15 kW low power scale prototype operating in DC and AC conditions are presented, in order to verify the feasibility and performance of the proposed system. © 2009 IEEE.
Resumo:
Distribution networks paradigm is changing currently requiring improved methodologies and tools for network analysis and planning. A relevant issue is analyzing the impact of the Distributed Generation penetration in passive networks considering different operation scenarios. Studying DG optimal siting and sizing the planner can identify the network behavior in presence of DG. Many approaches for the optimal DG allocation problem successfully used multi-objective optimization techniques. So this paper contributes to the fundamental stage of multi-objective optimization of finding the Pareto optimal solutions set. It is proposed the application of a Multi-objective Tabu Search and it was verified a better performance comparing to the NSGA-II method. © 2009 IEEE.
Resumo:
This paper proposes a methodology to consider the effects of the integration of DG on planning. Since DG has potential to defer investments in networks, the impact of DG on grid capacity is evaluated. A multi-objective optimization tool based on the meta-heuristic MEPSO is used, supporting an alternative approach to exploiting the Pareto front features. Tests were performed in distinct conditions with two well-known distribution networks: IEEE-34 and IEEE-123. The results combined minimization and maximization in order to produce different Pareto fronts and determine the extent of the impact caused by DG. The analysis provides useful information, such as the identification of futures that should be considered in planning. A future means a set of realizations of all uncertainties. MEPSO also presented a satisfactory performance in obtaining the Pareto fronts. © 2011 IEEE.
Resumo:
In Brazil, the state of São Paulo contains both preserved areas (Juréia-Itatins Ecological Station) and extremely impacted ones (Cubatão Municipality). This study evaluated the concentrations of five metals (Cu, Cd, Cr, Pb, and Hg) in two mangroves with different levels of anthropogenic impact and the apparent genotoxicity to Ucides cordatus. Water and sediment samples were obtained, and metal concentrations were determined with an atomic absorption spectrophotometer. The genotoxic impact was quantified based on the number of micronucleated cells per 1,000 analyzed (MN‰), using hemolymph slides stained with Giemsa. Metal concentrations in water were below the detection limit, except for lead, although no significant difference was observed between the areas (P > 0.05). Sediment from Cubatão had higher concentrations of Cd, Pb, Cr, and Cu than sediment from Juréia-Itatins (P < 0.05), but no significant differences in metal concentrations were detected among depth strata of the sediment (P > 0.05). Crabs from Cubatão had a 2.6 times higher mean frequency of micronucleated cells (5.2 ± 1.8 MN‰) than those from Juréia-Itatins (2.0 ± 1.0 MN‰; P < 0.0001). The more-polluted conditions found in the mangrove sediments of Cubatão were reflected in the micronucleus assay, demonstrating their genotoxic effect; however, genetic damage should be attributed to a synergistic effect with other kinds of pollutants previously recorded in different environments of Cubatão. U. cordatus proved to be an excellent bioindicator of mangrove pollution. This study established, for the first time, the normal frequency of MN‰ in a population of this species within an ecological station. © 2013 Springer Science+Business Media Dordrecht.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)