995 resultados para VOLUME TOMOGRAPHY
Resumo:
Our objective was to establish the age-related 3D size of maxillary, sphenoid, and frontal sinuses. A total of 179 magnetic resonance imaging (MRI) of children under 17 years (76 females, 103 males) were included and sinuses were measured in the three axes. Maxillary sinuses measured at birth (mean+/-standard deviation) 7.3+/-2.7 mm length (or antero-posterior)/4.0+/-0.9 mm height (or cranio-caudal)/2.7+/-0.8 mm width (or transverse). At 16 years old, maxillary sinus measured 38.8+/-3.5 mm/36.3+/-6.2 mm/27.5+/-4.2 mm. Sphenoid sinus pneumatization starts in the third year of life after conversion from red to fatty marrow with mean values of 5.8+/-1.4 mm/8.0+/-2.3 mm/5.8+/-1.0 mm. Pneumatization progresses gradually to reach at 16 years 23.0+/-4.5 mm/22.6+/-5.8 mm/12.8+/-3.1 mm. Frontal sinuses present a wide variation in size and most of the time are not valuable with routine head MRI techniques. They are not aerated before the age of 6 years. Frontal sinuses dimensions at 16 years were 12.8+/-5.0 mm/21.9+/-8.4 mm/24.5+/-13.3 mm. A sinus volume index (SVI) of maxillary and sphenoid sinus was computed using a simplified ellipsoid volume formula, and a table with SVI according to age with percentile variations is proposed for easy clinical application. Percentile curves of maxillary and sphenoid sinuses are presented to provide a basis for objective determination of sinus size and volume during development. These data are applicable to other techniques such as conventional X-ray and CT scan.
Resumo:
BACKGROUND: Prospective assessment of pedicled extrathoracic muscle flaps for the closure of large intrathoracic airway defects after noncircumferential resection in situations where an end-to-end reconstruction seemed risky (defects of > 4-cm length, desmoplastic reactions after previous infection or radiochemotherapy). METHODS: From 1996 to 2001, 13 intrathoracic muscle transpositions (6 latissimus dorsi and 7 serratus anterior muscle flaps) were performed to close defects of the intrathoracic airways after noncircumferential resection for tumor (n = 5), large tracheoesophageal fistula (n = 2), delayed tracheal injury (n = 1) and bronchopleural fistula (n = 5). In 2 patients, the extent of the tracheal defect required reinforcement of the reconstruction by use of a rib segment embedded into the muscle flap followed by temporary tracheal stenting. Patient follow-up was by clinical examination bronchoscopy and biopsy, pulmonary function tests, and dynamic virtual bronchoscopy by computed tomographic (CT) scan during inspiration and expiration. RESULTS: The airway defects ranged from 2 x 1 cm to 8 x 4 cm and involved up to 50% of the airway circumference. They were all successfully closed using muscle flaps with no mortality and all patients were extubated within 24 hours. Bronchoscopy revealed epithelialization of the reconstructions without dehiscence, stenosis, or recurrence of fistulas. The flow-volume loop was preserved in all patients and dynamic virtual bronchoscopy revealed no significant difference in the endoluminal cross surface areas of the airway between inspiration and expiration above (45 +/- 21 mm(2)), at the site (76 +/- 23 mm(2)) and below the reconstruction (65 +/- 40 mm(2)). CONCLUSIONS: Intrathoracic airway defects of up to 50% of the circumference may be repaired using extrathoracic muscle flaps when an end-to-end reconstruction is not feasible.
Resumo:
OBJECT: In this study the accuracy of multislice computerized tomography (MSCT) angiography in the postoperative examination of clip-occluded intracranial aneurysms was compared with that of intraarterial digital subtraction (DS) angiography METHODS: Forty-nine consecutive patients with 60 clipped aneurysms (41 of which had ruptured) were studied with the aid of postoperative MSCT and DS angiography. Both types of radiological studies were reviewed independently by two observers to assess the quality of the images, the artifacts left by the clips, the completeness of aneurysm occlusion, the patency of the parent vessel, and the duration and cost of the examination. The quality of MSCT angiography was good in 42 patients (86%). Poor-quality MSCT angiograms (14%) were a result of the late acquisition of images in three patients and the presence of clip or motion artifacts in four. Occlusion of the aneurysm on good-quality MSCT angiograms was confirmed in all but two patients in whom a small (2-mm) remnant was confirmed on DS angiograms. In one patient, occlusion of a parent vessel was seen on DS angiograms but missed on MSCT angiograms. The sensitivity and specificity for detecting neck remnants on MSCT angiography were both 100%, and the sensitivity and specificity for evaluating vessel patency were 80 and 100%, respectively (95% confidence interval 29.2-100%). Interobserver agreements were 0.765 and 0.86, respectively. The mean duration of the examination was 13 minutes for MSCT angiography and 75 minutes for DS angiography (p < 0.05). Multislice CT angiography was highly cost effective (p < 0.01). CONCLUSIONS: Current-generation MSCT angiography is an accurate noninvasive tool used for assessment of clipped aneurysms in the anterior circulation. Its high sensitivity and low cost warrant its use for postoperative routine control examinations following clip placement on an aneurysm. Digital subtraction angiography must be performed if the interpretation of MSCT angiograms is doubtful or if the aneurysm is located in the posterior circulation.
Resumo:
Most cases of emphysema are managed conservatively. However, in severe symptomatic emphysema associated with hyperinflation, lung volume reduction (LVR) may be proposed to improve dyspnea, exercice capacity, pulmonary functions, walk distance and to decrease long-term mortality. LVR may be achieved either surgically (LVRS) or endoscopically (EVLR by valves or coils) according to specific clinical criteria. Currently, the optimal approach is discussed in a multidisciplinary setting. The latter permits a personalized evaluation the patient's clinical status and allows the best possible therapeutic intervention to be proposed to the patient.
Resumo:
The multiscale finite volume (MsFV) method has been developed to efficiently solve large heterogeneous problems (elliptic or parabolic); it is usually employed for pressure equations and delivers conservative flux fields to be used in transport problems. The method essentially relies on the hypothesis that the (fine-scale) problem can be reasonably described by a set of local solutions coupled by a conservative global (coarse-scale) problem. In most cases, the boundary conditions assigned for the local problems are satisfactory and the approximate conservative fluxes provided by the method are accurate. In numerically challenging cases, however, a more accurate localization is required to obtain a good approximation of the fine-scale solution. In this paper we develop a procedure to iteratively improve the boundary conditions of the local problems. The algorithm relies on the data structure of the MsFV method and employs a Krylov-subspace projection method to obtain an unconditionally stable scheme and accelerate convergence. Two variants are considered: in the first, only the MsFV operator is used; in the second, the MsFV operator is combined in a two-step method with an operator derived from the problem solved to construct the conservative flux field. The resulting iterative MsFV algorithms allow arbitrary reduction of the solution error without compromising the construction of a conservative flux field, which is guaranteed at any iteration. Since it converges to the exact solution, the method can be regarded as a linear solver. In this context, the schemes proposed here can be viewed as preconditioned versions of the Generalized Minimal Residual method (GMRES), with a very peculiar characteristic that the residual on the coarse grid is zero at any iteration (thus conservative fluxes can be obtained).
Resumo:
OBJECT Monoenergetic imaging with dual-energy CT has been proposed to reduce metallic artifacts in comparison with conventional polychromatic CT. The purpose of this study is to systematically evaluate and define the optimal dual-energy CT imaging parameters for specific cervical spinal implant alloy compositions. METHODS Spinal fixation rods of cobalt-chromium or titanium alloy inserted into the cervical spine section of an Alderson Rando anthropomorphic phantom were imaged ex vivo with fast-kilovoltage switching CT at 80 and 140 peak kV. The collimation width and field of view were varied between 20 and 40 mm and medium to large, respectively. Extrapolated monoenergetic images were generated at 70, 90, 110, and 130 kiloelectron volts (keV). The standard deviation of voxel intensities along a circular line profile around the spine was used as an index of the magnitude of metallic artifact. RESULTS The metallic artifact was more conspicuous around the fixation rods made of cobalt-chromium than those of titanium alloy. The magnitude of metallic artifact seen with titanium fixation rods was minimized at monoenergies of 90 keV and higher, using a collimation width of 20 mm and large field of view. The magnitude of metallic artifact with cobalt-chromium fixation rods was minimized at monoenergies of 110 keV and higher; collimation width or field of view had no effect. CONCLUSIONS Optimization of acquisition settings used with monoenergetic CT studies might yield reduced metallic artifacts.
Resumo:
Background: To report a single-center experience in 19 patients (pts) with anal canal cancer treated with helical tomotherapy (HT) and concurrent chemotherapy, and compare the dosimetric results with fixed-field intensitymodulated radiotherapy (IMRT) and 3D conformal radiotherapy (3D RT). Materials and Methods: Between 2007 and 2008, 19 consecutive pts were treated with HT and concurrent CT for anal canal cancer. Median age was 59 years (range, 38−83), and female/male ratio was 14/5. The majority of the pts had T2 or T3 tumours (68.4%), and 52.6% had positive lymph nodes. In all 19 pts, pelvic and inguinal nodes, and tumour irradiation was given using HT upto a median dose of 36 Gy (1.8 Gy/fr) followed by a 1-week gap. A boost dose of 23.4 Gy (1.8 Gy/fr) was delivered to the tumour and involved nodes using 3DRT (n = 12), HT (n = 6), or IMRT (n = 1). Simultaneous integrated boost was used in none of the pts. All but one patient with a T1N0 tumour received concomitant mitomycin/5- fluorouracil (n = 12) or mitomycin/capecitabin (n = 7) CT. Toxicity was scored according to the Common Terminology Criteria for Adverse Events (NCICTCAE v3.0). HT plans and treatments were generated using Tomotherapy, Inc., software and hardware; and 3D or IMRT boost plans with the CMS treatment planning system (TPS), using 6−18 MV photons from a Siemens Primus accelerator. For dosimetric comparison, computed tomography data sets of 10 pts were imported into the TPS, and 3D and 5-field step-andshoot IMRT plans were generated for each case. Plans were optimized with the aim of assessing organs at risk (OAR) and healthy-tissue sparing while enforcing highly conformal target coverage, and evaluated by dose-volume histograms (DVH) of planning target volumes (PTV) and OAR. Results: With a median follow-up of 13 months (range, 3−18), all pts are alive and well; except one patient developing local recurrence at 12 months. No patient developed grade 3 or more acute toxicity. No unplanned treatment interruption was necessary because of toxicity. With 360-degree-of-freedom beam projection, HT showed an advantage over 3D or IMRT plans in terms of dose conformity around the PTV, and dose gradients were steeper outside the PTV, resulting in reduced doses to OARs. Using HT, acute toxicity was acceptable, and seemed to be better than historical standards. Conclusion: We conclude that HT combined with concurrent chemotherapy for anal canal cancer is effective and tolerable. Compared to 3DRT or 5-field IMRT, there is better conformity around the PTV, and OAR sparing.
Resumo:
INTRODUCTION. Neurally Adjusted Ventilatory Assist (NAVA) is an assisted ventilatorymode in which the ventilator is driven by the electrical activity of the diaphragm (Eadi).NAVAimproves patient-ventilator synchrony [1] but little is known about how to set the NAVA gaini.e., how to choose the ratio between Eadi and delivered pressure. The aim of the present studywas to assess the relationship between Eadi and tidal volume (Vt) at various NAVA gainsettings and to evaluate whether modifying the gain influenced this relationship in non-invasivelyventilated (NIV) patients.METHODS. Prospective interventional study comparing 3 values of NAVA gain during NIV(20 min each). NAVA100 was set by the clinician according to the manufacturer's recommendations.In NAVA50 and NAVA150 the gain was set as -50% and +50% of NAVA100gain respectively. Vt and maximal Eadi value (Eadi max) were recorded. The ratio Vt/Eadi wasthen assessed for each breath. 5-95% range (range 90) of Vt/Eadi was calculated for eachpatient at each NAVA gain setting. Vt/Eadi ratio has the advantage to give an objectiveassessment Vt/Eadi max relationship independently from the nature of this relationship. Asmaller Range90 indicates a better matching of Vt to Eadi max.RESULTS. 12 patients were included, 5 had obstructive pulmonary disease and 2 mixedobstructive and restrictive disease. For NAVA100, the median [IQR] Range 90 was 32[19-87]. For NAVA150 Range 90 was 37 [20-95] and for NAVA50 Range 90 was 33 [16-92].That means that globally NAVA100 allowed a better match between Eadi max and Vt thanNAVA50 and 150. However, by patient, NAVA100 had the lowest Range 90 value for only 4patients (33%), NAVA150 for 2 (17%) and NAVA50 for 6 (50%) patients, indicating thatNAVA100 was not the best NAVA gain for minimizing Range 90 in every patients.Comparing the lowest Range 90 value to the next lowest for each patient, showed that 3 patientshad differences of less than 10% (one each for NAVA50, NAVA100 and NAVA150). Theremainder had differences from 17 to 24%, indicating that most patients (9/12 or 75%) had aclear better match between Eadi and Vt for one specific NAVA gain.CONCLUSIONS. Different NAVA gains yielded markedly different ability to match Vt toEadi max. This approach could be a new way to determine optimalNAVAgain for each patientbut require further investigations.REFERENCE. Piquilloud L, et al. Intensive Care Med 2011;37:263-71.
Resumo:
Stiffness tomography is a new atomic force microscopy imaging technique that allows highlighting structures located underneath the surface of the sample. In this imaging mode, such structures are identified by investigating their mechanical properties. We present here, for the first time, a description of the use of this technique to acquire detailed stiffness maps of fixed and living macrophages. Indeed, the mechanical properties of several macrophages were studied through stiffness tomography imaging, allowing some insight of the structures lying below the cell's surface. Through these investigations, we were able to evidence the presence and properties of stiff column-like features located underneath the cell membrane. To our knowledge, this is the first evidence of the presence, underneath the cell membrane, of such stiff features, which are in dimension and form compatible with phagosomes. Moreover, by exposing the cells to cytochalasin, we were able to study the induced modifications, obtaining an indication of the location and mechanical properties of the actin cytoskeleton. Copyright © 2012 John Wiley & Sons, Ltd.
Resumo:
BACKGROUND: Positron emission tomography (PET) during the cold pressor test (CPT) has been used to assess endothelium-dependent coronary vasoreactivity, a surrogate marker of cardiovascular events. However, its use remains limited by cardiac PET availability. As multidetector computed tomography (MDCT) is more widely available, we aimed to develop a measurement of endothelium-dependent coronary vasoreactivity with MDCT and similar radiation burden as with PET. METHODS AND RESULTS: A study group of 18 participants without known cardiovascular risk factor (9F/9M; age 60±6 years) underwent cardiac PET with (82)Rb and unenhanced ECG-gated MDCT within 4h, each time at rest and during CPT. The relation between absolute myocardial blood flow (MBF) response to CPT by PET (ml·min(-1)·g(1)) and relative changes in MDCT-measured coronary artery surface were assessed using linear regression analysis and Spearman's correlation. MDCT and PET/CT were analyzed in all participants. Hemodynamic conditions during CPT at MDCT and PET were similar (P>0.3). Relative changes in coronary artery surface because of CPT (2.0-21.2%) correlated to changes in MBF (-0.10-0.52ml·min(-1)·g(1)) (ρ=0.68, P=0.02). Effective dose was 1.3±0.2mSv for MDCT and 3.1mSv for PET/CT. CONCLUSIONS: Assessment of endothelium-dependent coronary vasoreactivity using MDCT CPT appears feasible. Because of its wider availability, shorter examination time and similar radiation burden, MDCT could be attractive in clinical research for coronary status assessment.
Resumo:
INTRODUCTION Hemodynamic resuscitation should be aimed at achieving not only adequate cardiac output but also sufficient mean arterial pressure (MAP) to guarantee adequate tissue perfusion pressure. Since the arterial pressure response to volume expansion (VE) depends on arterial tone, knowing whether a patient is preload-dependent provides only a partial solution to the problem. The objective of this study was to assess the ability of a functional evaluation of arterial tone by dynamic arterial elastance (Ea(dyn)), defined as the pulse pressure variation (PPV) to stroke volume variation (SVV) ratio, to predict the hemodynamic response in MAP to fluid administration in hypotensive, preload-dependent patients with acute circulatory failure. METHODS We performed a prospective clinical study in an adult medical/surgical intensive care unit in a tertiary care teaching hospital, including 25 patients with controlled mechanical ventilation who were monitored with the Vigileo(®) monitor, for whom the decision to give fluids was made because of the presence of acute circulatory failure, including arterial hypotension (MAP ≤65 mmHg or systolic arterial pressure <90 mmHg) and preserved preload responsiveness condition, defined as a SVV value ≥10%. RESULTS Before fluid infusion, Ea(dyn) was significantly different between MAP responders (MAP increase ≥15% after VE) and MAP nonresponders. VE-induced increases in MAP were strongly correlated with baseline Ea(dyn) (r(2) = 0.83; P < 0.0001). The only predictor of MAP increase was Ea(dyn) (area under the curve, 0.986 ± 0.02; 95% confidence interval (CI), 0.84-1). A baseline Ea(dyn) value >0.89 predicted a MAP increase after fluid administration with a sensitivity of 93.75% (95% CI, 69.8%-99.8%) and a specificity of 100% (95% CI, 66.4%-100%). CONCLUSIONS Functional assessment of arterial tone by Ea(dyn), measured as the PVV to SVV ratio, predicted arterial pressure response after volume loading in hypotensive, preload-dependent patients under controlled mechanical ventilation.
Resumo:
BACKGROUND: In numerous high-risk medical and surgical conditions, a greater volume of patients undergoing treatment in a given setting or facility is associated with better survival. For patients with pulmonary embolism, the relation between the number of patients treated in a hospital (volume) and patient outcome is unknown. METHODS: We studied discharge records from 186 acute care hospitals in Pennsylvania for a total of 15 531 patients for whom the primary diagnosis was pulmonary embolism. The study outcomes were all-cause mortality in hospital and within 30 days after presentation for pulmonary embolism and the length of hospital stay. We used logistic models to study the association between hospital volume and 30-day mortality and discrete survival models to study the association between in-hospital mortality and time to hospital discharge. RESULTS: The median annual hospital volume for pulmonary embolism was 20 patients (interquartile range 10-42). Overall in-hospital mortality was 6.0%, whereas 30-day mortality was 9.3%. In multivariable analysis, very-high-volume hospitals (> or = 42 cases per year) had a significantly lower odds of in-hospital death (odds ratio [OR] 0.71, 95% confidence interval [CI] 0.51-0.99) and of 30-day death (OR 0.71, 95% CI 0.54-0.92) than very-low-volume hospitals (< 10 cases per year). Although patients in the very-high-volume hospitals had a slightly longer length of stay than those in the very-low-volume hospitals (mean difference 0.7 days), there was no association between volume and length of stay. INTERPRETATION: In hospitals with a high volume of cases, pulmonary embolism was associated with lower short-term mortality. Further research is required to determine the causes of the relation between volume and outcome for patients with pulmonary embolism.
Resumo:
[Mahābhārata (français). 1863-]