951 resultados para Time-domain nuclear magnetic resonance relaxometry


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The vascular properties of large vessels in the obese have not been adequately studied. We used cardiovascular magnetic resonance imaging to quantify the cross-sectional area and elastic properties of the ascending thoracic and abdominal aorta in 21 clinically healthy obese young adult men and 25 men who were age-matched lean controls. Obese subjects had greater maximal cross-sectional area of the ascending thoracic aorta (984 +/- 252 vs 786 +/- 109 mm(2), p <0.01) and of the abdominal aorta (415 +/- 71 vs 374 +/- 51 mm(2), p <0.05). When indexed for height the differences persisted, but when indexed for body surface area, a significant difference between groups was found only for the maximal abdominal aortic cross-sectional area. The obese subjects also had decreased abdominal aortic elasticity, characterized by 24% lower compliance (0.0017 +/- 0.0004 vs 0.0021 +/- 0.0005 mm(2)/kPa/mm, p <0.01), 22% higher stiffness index beta (6.0 +/- 1.5 vs 4.9 +/- 0.7, p <0.005), and 41% greater pressure-strain elastic modulus (72 +/- 25 vs 51 +/- 9, p <0.005). At the ascending thoracic aorta, only the pressure-strain elastic modulus was different between obese and lean subjects (85 +/- 42 vs 65 +/- 26 kPa, respectively; p <0.05), corresponding to a 31% difference-but arterial compliance and stiffness index were not significantly different between groups. In clinically healthy young adult obese men, obesity is associated with increased cross-sectional aortic area and decreased aortic elasticity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this work was to develop an alternative methodology to study and characterize the phosphate crystalline properties, directly associated with solubility and plant availability, in biochar from swine bones. Some phosphate symmetry properties of pyrolyzed swine bones were established, using solid state nuclear magnetic resonance spectroscopy, principal component analysis, and multivariate curve resolution analysis, on four pyrolyzed samples at different carbonization intensities. Increasing carbonization parameters (temperature or residence time) generates diverse phosphate structures, increasing their symmetry and decreasing the crossed polarizability of the pair ¹H-31P, producing phosphates with, probably, lower solubility than the ones produced at lower carbonization intensity. Additionally, a new methodology is being developed to study and characterize phosphate crystalline properties directly associated with phosphate solubility and availability to plants.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper the problem of intensity inhomogeneity athigh magnetic field on magnetic resonance images isaddressed. Specifically, rat brain images at 9.4Tacquired with a surface coil are bias corrected. Wepropose a low- pass frequency model that takes intoaccount not only background-object contours but alsoother important contours inside the image. Twopre-processing filters are proposed: first, to create avolume of interest without contours, and second, toextrapolate the image values of such masked area to thewhole image. Results are assessed quantitatively andvisually in comparison to standard low pass filterapproach, and they show as expected better accuracy inenhancing image intensity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Patients with type 1 diabetes and nephropathy maintain an excess cardiovascular mortality compared with diabetic patients with normoalbuminuria. We sought to evaluate coronary and aortic atherosclerosis in a cohort of asymptomatic type 1 diabetic patients with and without diabetic nephropathy using cardiovascular magnetic resonance imaging. METHODS AND RESULTS: In a cross-sectional study, 136 subjects with long-standing type 1 diabetes without symptoms or history of cardiovascular disease, including 63 patients (46%) with nephropathy and 73 patients with normoalbuminuria, underwent cardiovascular magnetic resonance imaging. All subjects underwent cardiac exercise testing and noninvasive tests for peripheral artery disease and autonomic neuropathy. Coronary artery stenoses were identified in 10% of subjects with nephropathy (versus 0% with normoalbuminuria; P=0.007). Coronary plaque burden, expressed as right coronary artery mean wall thickness (1.7+/-0.3 versus 1.3+/-0.2 mm; P<0.001) and maximum right coronary artery wall thickness (2.2+/-0.5 versus 1.6+/-0.3 mm; P<0.001), was greater in subjects with nephropathy. The prevalence of thoracic (3% versus 0%; P=0.28) and abdominal aortic plaque (22% versus 16%; P=0.7) was similar in both groups. Subjects with and without abdominal aortic plaques had similar coronary plaque burden. CONCLUSIONS: In asymptomatic type 1 diabetes, cardiovascular magnetic resonance imaging reveals greater coronary plaque burden in subjects with nephropathy compared with those with normoalbuminuria.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

STUDY DESIGN.: Retrospective radiologic study on a prospective patient cohort. OBJECTIVE.: To devise a qualitative grading of lumbar spinal stenosis (LSS), study its reliability and clinical relevance. SUMMARY OF BACKGROUND DATA.: Radiologic stenosis is assessed commonly by measuring dural sac cross-sectional area (DSCA). Great variation is observed though in surfaces recorded between symptomatic and asymptomatic individuals. METHODS.: We describe a 7-grade classification based on the morphology of the dural sac as observed on T2 axial magnetic resonance images based on the rootlet/cerebrospinal fluid ratio. Grades A and B show cerebrospinal fluid presence while grades C and D show none at all. The grading was applied to magnetic resonance images of 95 subjects divided in 3 groups as follows: 37 symptomatic LSS surgically treated patients; 31 symptomatic LSS conservatively treated patients (average follow-up, 2.5 and 3.1 years); and 27 low back pain (LBP) sufferers. DSCA was also digitally measured. We studied intra- and interobserver reliability, distribution of grades, relation between morphologic grading and DSCA, as well relation between grades, DSCA, and Oswestry Disability Index. RESULTS.: Average intra- and interobserver agreement was substantial and moderate, respectively (k = 0.65 and 0.44), whereas they were substantial for physicians working in the study originating unit. Surgical patients had the smallest DSCA. A larger proportion of C and D grades was observed in the surgical group. Surface measurementsresulted in overdiagnosis of stenosis in 35 patients and under diagnosis in 12. No relation could be found between stenosis grade or DSCA and baseline Oswestry Disability Index or surgical result. C and D grade patients were more likely to fail conservative treatment, whereas grades A and B were less likely to warrant surgery. CONCLUSION.: The grading defines stenosis in different subjects than surface measurements alone. Since it mainly considers impingement of neural tissue it might be a more appropriate clinical and research tool as well as carrying a prognostic value.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Many audio watermarking schemes divide the audio signal into several blocks such that part of the watermark is embedded into each of them. One of the key issues in these block-oriented watermarking schemes is to preserve the synchronisation, i.e. to recover the exact position of each block in the mark recovery process. In this paper, a novel time domain synchronisation technique is presented together with a new blind watermarking scheme which works in the Discrete Fourier Transform (DFT or FFT) domain. The combined scheme provides excellent imperceptibility results whilst achieving robustness against typical attacks. Furthermore, the execution of the scheme is fast enough to be used in real-time applications. The excellent transparency of the embedding algorithm makes it particularly useful for professional applications, such as the embedding of monitoring information in broadcast signals. The scheme is also compared with some recent results of the literature.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

ABSTRACT: BACKGROUND: Perfusion-cardiovascular magnetic resonance (CMR) is generally accepted as an alternative to SPECT to assess myocardial ischemia non-invasively. However its performance vs gated-SPECT and in sub-populations is not fully established. The goal was to compare in a multicenter setting the diagnostic performance of perfusion-CMR and gated-SPECT for the detection of CAD in various populations using conventional x-ray coronary angiography (CXA) as the standard of reference. METHODS: In 33 centers (in US and Europe) 533 patients, eligible for CXA or SPECT, were enrolled in this multivendor trial. SPECT and CXA were performed within 4 weeks before or after CMR in all patients. Prevalence of CAD in the sample was 49% and 515 patients received MR contrast medium. Drop-out rates for CMR and SPECT were 5.6% and 3.7%, respectively (ns). The study was powered for the primary endpoint of non-inferiority of CMR vs SPECT for both, sensitivity and specificity for the detection of CAD (using a single-threshold reading), the results for the primary endpoint were reported elsewhere. In this article secondary endpoints are presented, i.e. the diagnostic performance of CMR versus SPECT in subpopulations such as multi-vessel disease (MVD), in men, in women, and in patients without prior myocardial infarction (MI). For diagnostic performance assessment the area under the receiver-operator-characteristics-curve (AUC) was calculated. Readers were blinded versus clinical data, CXA, and imaging results. RESULTS: The diagnostic performance (= area under ROC = AUC) of CMR was superior to SPECT (p = 0.0004, n = 425) and to gated-SPECT (p = 0.018, n = 253). CMR performed better than SPECT in MVD (p = 0.003 vs all SPECT, p = 0.04 vs gated-SPECT), in men (p = 0.004, n = 313) and in women (p = 0.03, n = 112) as well as in the non-infarct patients (p = 0.005, n = 186 in 1-3 vessel disease and p = 0.015, n = 140 in MVD). CONCLUSION: In this large multicenter, multivendor study the diagnostic performance of perfusion-CMR to detect CAD was superior to perfusion SPECT in the entire population and in sub-groups. Perfusion-CMR can be recommended as an alternative for SPECT imaging. TRIAL REGISTRATION: ClinicalTrials.gov, Identifier: NCT00977093.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate the reproducibility of Cirrus-SD OCT measurements and to compare central macular thickness (CMT) measurements between TD-Stratus and SD-Cirrus OCT in patients with active exudative AMD. Methods: Consecutive case series of patients with active exudative AMD seen in the Medical Retina Department. Patients underwent 1 scan with Stratus (macular thickness map protocol) and 5 scans with Cirrus (Macular Cube protocol) at the same visit by the same experienced examiner. To be included, patients best-corrected visual acuity (BCVA) had to be >20/200 while all scans had to be of sufficient quality, well-centered and at least one Cirrus scan with CMT >300 microns. The repeatability of the SD Cirrus was estimated by using all 5 CMT measurements and the mean of the Cirrus measurements was compared with the CMT obtained by TD Stratus. Results: Cirrus OCT demonstrated high intraobserver repeatability at the central foveal region (ICC 96%). The mean of the CMT measurements was 321microns for Stratus and 387 microns for Cirrus. The average difference was 65m (SD=30). The coefficient of concordance between Stratus and Cirrus CMT measurements was rho=0,749 with a high precision and a moderate accuracy. The equation of the line of regression between Stratus and meanCirrus is given by the following: M_stratus = 0,848 x m_cirrus - 4,496 (1).Conclusions: The Cirrus macular cube protocol allows reproducible CMT measurements in patients with active exudative AMD. In cases of upgrading from TD to SD use and vice versa, there is the possibility to predict the measurements by using the equation (1). These real life data and conclusions can help in improving our clinical management of patients with neovascular AMD.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The impact of depressed neonatal cerebral oxidative phosphorylation for diagnosing the severity of perinatal asphyxia was estimated by correlating the concentrations of phosphocreatine (PCr) and ATP as determined by magnetic resonance spectroscopy with the degree of hypoxic-ischemic encephalopathy (HIE) in 23 asphyxiated term neonates. Ten healthy age-matched neonates served as controls. In patients, the mean concentrations +/- SD of PCr and ATP were 0.99 +/- 0.46 mmol/L (1.6 +/- 0.2 mmol/L) and 0.99 +/- 0.35 mmol/L (1.7 +/- 0.2 mmol/L), respectively (normal values in parentheses). [PCr] and [ATP] correlated significantly with the severity of HIE (r = 0.85 and 0.9, respectively, p < 0.001), indicating that the neonatal encephalopathy is the clinical manifestation of a marred brain energy metabolism. Neurodevelopmental outcome was evaluated in 21 children at 3, 9, and 18 mo. Seven infants had multiple impairments, five were moderately handicapped, five had only mild symptoms, and four were normal. There was a significant correlation between the cerebral concentrations of PCr or ATP at birth and outcome (r = 0.8, p < 0.001) and between the degree of neonatal neurologic depression and outcome (r = 0.7). More important, the outcome of neonates with moderate HIE could better be predicted with information from quantitative 31P magnetic resonance spectroscopy than from neurologic examinations. In general, the accuracy of outcome predictability could significantly be increased by adding results from 31P magnetic resonance spectroscopy to the neonatal neurologic score, but not vice versa. No correlation with outcome was found for other perinatal risk factors, including Apgar score.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In order to compare coronary magnetic resonance angiography (MRA) data obtained with different scanning methodologies, adequate visualization and presentation of the coronary MRA data need to be ensured. Furthermore, an objective quantitative comparison between images acquired with different scanning methods is desirable. To address this need, a software tool ("Soap-Bubble") that facilitates visualization and quantitative comparison of 3D volume targeted coronary MRA data was developed. In the present implementation, the user interactively specifies a curved subvolume (enclosed in the 3D coronary MRA data set) that closely encompasses the coronary arterial segments. With a 3D Delaunay triangulation and a parallel projection, this enables the simultaneous display of multiple coronary segments in one 2D representation. For objective quantitative analysis, frequently explored quantitative parameters such as signal-to-noise ratio (SNR); contrast-to-noise ratio (CNR); and vessel length, sharpness, and diameter can be assessed. The present tool supports visualization and objective, quantitative comparisons of coronary MRA data obtained with different scanning methods. The first results obtained in healthy adults and in patients with coronary artery disease are presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thanks to the continuous progress made in recent years, medical imaging has become an important tool in the diagnosis of various pathologies. In particular, magnetic resonance imaging (MRI) permits to obtain images with a remarkably high resolution without the use of ionizing radiation and is consequently widely applied for a broad range of conditions in all parts of the body. Contrast agents are used in MRI to improve tissue discrimination. Different categories of contrast agents are clinically available, the most widely used being gadolinium chelates. One can distinguish between extracellular gadolinium chelates such as Gd-DTPA, and hepatobiliary gadolinium chelates such as Gd-BOPTA. The latter are able to enter hepatocytes from where they are partially excreted into the bile to an extent dependent on the contrast agent and animal species. Due to this property, hepatobiliary contrast agents are particularly interesting for the MRI of the liver. Actually, a change in signal intensity can result from a change in transport functions signaling the presence of impaired hepatocytes, e.g. in the case of focal (like cancer) or diffuse (like cirrhosis) liver diseases. Although the excretion mechanism into the bile is well known, the uptake mechanisms of hepatobiliary contrast agents into hepatocytes are still not completely understood and several hypotheses have been proposed. As a good knowledge of these transport mechanisms is required to allow an efficient diagnosis by MRI of the functional state of the liver, more fundamental research is needed and an efficient MRI compatible in vitro model would be an asset. So far, most data concerning these transport mechanisms have been obtained by MRI with in vivo models or by a method of detection other than MRI with cellular or sub-cellular models. Actually, no in vitro model is currently available for the study and quantification of contrast agents by MRI notably because high cellular densities are needed to allow detection, and no metallic devices can be used inside the magnet room, which is incompatible with most tissue or cell cultures that require controlled temperature and oxygenation. The aim of this thesis is thus to develop an MRI compatible in vitro cellular model to study the transport of hepatobiliary contrast agents, in particular Gd-BOPTA, into hepatocytes directly by MRI. A better understanding of this transport and especially of its modification in case of hepatic disorder could permit in a second step to extrapolate this knowledge to humans and to use the kinetics of hepatobiliary contrast agents as a tool for the diagnosis of hepatic diseases.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cardiac failure is one of the leading causes of mortality in developed countries. As life expectancies of the populations of these countries grow, the number of patients suffering from cardiac insufficiency also increase. Effective treatments including the use of calcium sensitisers are being sought. They cause a positive inodilatory effect on cardio-myocytes without deleterious effects (arrhythmias) resulting from increases in intracellular calcium concentration. Levosimendan is a novel calcium sensitiser that hasbeen proved to be a welltolerated and effective treatment for patients with severe decompensated heart failure. Cardiac troponin C (cTnC) is its target protein. However, there have been controversies about the interactions between levosimendan and cTnC. Some of these controversies have been addressed in this dissertation. Furthermore, studies on the calcium sensitising mechanism based on the interactions between levosimendan and cTnC as followed by nuclear magnetic resonance(NMR) are presented and discussed. Levosimendan was found to interact with bothdomains of the calcium-saturated cTnC in the absence of cardiac troponin I (cTnI). In the presence of cTnI, the C-domain binding site was blocked and levosimendan interacted only with the regulatory domain of cTnC. This interaction may have caused the observed calcium sensitising effect by priming the N-domain for cTnI binding thereby extending the lifetime of that complex. It is suggested that this is achieved by shifting the equilibrium between open and closed conformations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To compare qualitative and quantitative magnetic resonance (MR) imaging characteristics of hepatic hemangiomas in patients with normal, fibrotic and cirrhotic livers. MATERIALS AND METHODS: Retrospective, institutional review board approved study (waiver of informed consent). Eighty-nine consecutive patients with 231 hepatic hemangiomas who underwent liver MR imaging for lesion characterization were included. Lesions were classified into three groups according to the patients' liver condition: no underlying liver disease (group 1), fibrosis (group 2) and cirrhosis (group 3). Qualitative and quantitative characteristics (number, size, signal intensities on T1-, T2-, and DW MR images, T2 shine-through effect, enhancement patterns (classical, rapidly filling, delayed filling), and ADC values) were compared. RESULTS: There were 160 (69%), 45 (20%), and 26 (11%) hemangiomas in groups 1, 2 and 3, respectively. Lesions were larger in patients with normal liver (group 1 vs. groups 2 and 3; P=.009). No difference was found between the groups on T2-weighted images (fat-suppressed fast spin-echo (P=.82) and single-shot (P=.25)) and in enhancement patterns (P=.56). Mean ADC values of hemangiomas were similar between groups 1, 2 and 3 (2.11±.52×10(-3)mm(2)/s, 2.1±.53×10(-3)mm(2)/s and 2.14±.44×10(-3)mm(2)/s, P=87, respectively). T2 shine-through effect was less frequently observed in cirrhosis (P=.02). CONCLUSION: MR imaging characteristics of hepatic hemangioma were similar in patients with normal compared to fibrotic and cirrhotic livers. Smaller lesion size was observed with liver disease and less T2 shine-through effect was seen in hemangiomas developed on cirrhosis, the latter being an important finding to highlight in these patients at risk of developing hepatocellular carcinoma.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article provides expert opinion on the use of cardiovascular magnetic resonance (CMR) in young patients with congenital heart disease (CHD) and in specific clinical situations. As peculiar challenges apply to imaging children, paediatric aspects are repeatedly discussed. The first section of the paper addresses settings and techniques, including the basic sequences used in paediatric CMR, safety, and sedation. In the second section, the indication, application, and clinical relevance of CMR in the most frequent CHD are discussed in detail. In the current era of multimodality imaging, the strengths of CMR are compared with other imaging modalities. At the end of each chapter, a brief summary with expert consensus key points is provided. The recommendations provided are strongly clinically oriented. The paper addresses not only imagers performing CMR, but also clinical cardiologists who want to know which information can be obtained by CMR and how to integrate it in clinical decision-making.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Postmortem MRI (PMMR) examinations are seldom performed in legal medicine due to long examination times, unfamiliarity with the technique, and high costs. Furthermore, it is difficult to obtain access to an MRI device used for patients in clinical settings to image an entire human body. An alternative is available: ex situ organ examination. To our knowledge, there is no standardized protocol that includes ex situ organ preparation and scanning parameters for postmortem MRI. Thus, our objective was to develop a standard procedure for ex situ heart PMMR examinations. We also tested the oily contrast agent Angiofil® commonly used for PMCT angiography, for its applicability in MRI. We worked with a 3 Tesla MRI device and 32-channel head coils. Twelve porcine hearts were used to test different materials to find the best way to prepare and place organs in the device and to test scanning parameters. For coronary MR angiography, we tested different mixtures of Angiofil® and different injection materials. In a second step, 17 human hearts were examined to test the procedure and its applicability to human organs. We established two standardized protocols: one for preparation of the heart and another for scanning parameters based on experience in clinical practice. The established protocols enabled a standardized technical procedure with comparable radiological images, allowing for easy radiological reading. The performance of coronary MR angiography enabled detailed coronary assessment and revealed the utility of Angiofil® as a contrast agent for PMMR. Our simple, reproducible method for performing heart examinations ex situ yields high quality images and visualization of the coronary arteries.