856 resultados para Tele-oftalmologia


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the characteristics of patients with anophthalmic cavity who developed sphere extrusion. Methods: A retrospective observational study was done evaluating 37 patients with anophthalmic cavity and sphere extrusion at the Faculdade de Medicina de Botucatu-UNESP. Results: Extrusion was observed in enucleated and eviscerated cavities. The majority of the patients had the eye removed because of phthisis bulbi or trauma and the extrusion happened 1 or 2 years after the surgery. Extrusion was preceded by conjunctival dehiscence and exposure of the sphere and occurred with all used implants. Conclusion: Complications after orbital implant placement are a possibility. Dehiscence and sphere extrusion may happen and another surgery would be necessary. The patient and the ophthalmologist have to be prepared for this.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To determine if the AutoCAD 2004 program is available to be used in quantitative research on electron microscopy. Methods: A demonstrative of the AutoCAD2004 was done in an experimental model of diabetes induced in rats. The animals were divided by lot in control group animals (GC-10 animals) and diabetic group (GD - 10 animals), evaluated 1 month after the diabetes induction.The eyes were removed after sacrifice and prepared to electron microscopy. The retina was photographed and the AutoCAD2004 program was used to measure the basal membrane of retina vessels. The results were submitted to statistical analysis. Results:The AutoCAD2004 was effective to obtain quantitative measures from the basal membrane of retina vessels and there were no difference between the studied groups. Conclusion: The AutoCAD2004 was effective, safe and easy to apply to quantify biological parameters, which allowed suggest it to quantitative research.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to report a case of external ophthalmomyiasis caused by Cochliomyia hominivorax in a 10 years-old child, which presented acute preseptal celulitis and had 17 worms removed from the lacrimal canaliculus and conjunctival cul de sac, bilaterally, with resolution. The authors discuss the diagnosis and treatment of this nosological entity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this paper is to report a recidivate basal cell carcinoma of the eyelid with orbital invasion located in the inner canthus of the left eye. A 79 year old, male, Caucasian patient had a basal cell carcinoma removed from the left inner eyelid canthus 8 years ago and the edges of the resection were compromised by the lesion. The patient had recurrence of the lesion and orbital invasion. He was submitted to orbital exenteration and the ethmoid bone was removed too. The authors call attention to the necessity of correct diagnosis and followup to have success in the management of the patient.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The present study aimed to evaluate an injectable extended-release formulation of prednisolone acetate (PA) for orbital administration. Methods: Microspheres (MEs) of poly-ε-caprolactone (PCL) containing PA were developed by the method of solvent evaporation. The MEs obtained were characterized by scanning electron microscopy (SEM), differential scanning calorimetry (DSC), encapsulation efficiency and in vitro release profile. The in vivo release profile was evaluated in rabbits after periocular injection of an aqueous suspension of MEs. The local biocompatibility of the system was verified by histopathologic analysis of the deployment region. Results: After MEs preparation, morphological analysis by SEM showed the feasibility of the employed method. The content of PA encapsulated was 43 ± 7% and can be considered as satisfactory. The system characterization by DSC technique, in addition to confirm the system stability, did not indicate the existence of interaction between the drug and the polymer. The in vitro release study showed the prolonged-release features of the developed system. Preliminary in vivo study showed the absence of local toxicity and confirmed the prolonged release profile of PA from MEs, suggesting the viability of the developed system for the treatment of orbital inflammatory diseases. Conclusion: The results obtained in this work are relevant and accredit the system developed as a possible alternative to the treatment of inflammatory orbitopathy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: This paper describes proposed health care services innovations, provided by a system called CAALYX (Complete Ambient Assisted Living eXperiment). CAALYX aimed to provide healthcare innovation by extending the state-of-the-art in tele-healthcare, by focusing on increasing the confidence of elderly people living autonomously, by building on the knowledge base of the most common disorders and respective characteristic vital sign changes for this age group. Methods: A review of the state-of-the-art on health care services was carried out. Then, extensive research was conducted on the particular needs of the elderly in relation to home health services that, if offered to them, could improve their day life by giving them greater confidence and autonomy. To achieve this, we addressed issues associated with the gathering of clinical data and interpretation of these data, as well as possibilities of automatically triggering appropriate clinical measures. Considering this initial work we started the identification of initiatives, ongoing works and technologies that could be used for the development of the system. After that, the implementation of CAALYX was done. Findings: The innovation in CAALYX system considers three main areas of contribution: (i) The Roaming Monitoring System that is used to collect information on the well-being of the elderly users; (ii) The Home Monitoring System that is aimed at helping the elders independently living at home being implemented by a device (a personal computer or a set top box) that supports the connection of sensors and video cameras that may be used for monitoring and for interaction with the elder; (iii) The Central Care Service and Monitoring System that is implemented by a Caretaker System where attention and care services are provided to elders, where actors as Caretakers, Doctors and Relatives are logically linked to elders. Innovations in each of these areas are presented here. Conclusions: The ageing European society is placing an added burden on future generations, as the 'elderly-to-working-age-people' ratio is set to steadily increase in the future. Nowadays, quality of life and fitness allows for most older persons to have an active life well into their eighties. Furthermore, many older persons prefer to live in their own house and choose their own lifestyle. The CAALYX system can have a clear impact in increasing older persons' autonomy, by ensuring that they do not need to leave their preferred environment in order to be properly monitored and taken care of. © 2011 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Incluye Bibliografía

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To observe the frequency of the occurrence of the anophthalmic socket in the Middle West region of the state of São Paulo and to describe the demographic profile of the carriers in a population-based data. Methods: A cross-sectional study involve a random sampling carried out in twelve cities of the Middle West region of the state of São Paulo, for which the reference center is the city of Botucatu was done. The participators were chosen by assortment which considered the houses of these people. It was established a sampling with 11,453 people. All the exams were realized using a Mobile Ophthalmologic Unit. The research protocol included the demographic data and the complete ophthalmologic exam (anamnesis, ocular and systemic antecedents, familiar antecedents, visual acuity with and without correction, tonometry, biomicroscopy, fundoscopy, and refraction exam). All the data were transferred to an Excel spreadsheet and submitted to a descriptive analysis and were presented by the frequency of the occurrence. Results: Ophthalmic socket frequency in the Middle West region of the state of São Paulo was 0.96%. We found 11 cases of anophthalmic socket, with involvement of 0.7 % in females and 1.3 %, male. The most common causes of anophthalmic socket were glaucoma (blind painful eye), microphthalmia, trauma, and endophthalmitis. The majority of the people were 40 years old or more, and we found just one person younger than 19 years old. Conclusion: The anophthalmic socket occurred in 0.96% of the habitants of the Middle West region of São Paulo State, occurring mainly in male and with large variety of the affected ages.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Estudos Linguísticos - IBILCE

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)