907 resultados para Stabilisation of filter


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Previous study on the resistance of larvae of Sesarma curacaoense submitted to starvation has revealed a facultative lecithotrophy during zoeal stages, but megalopa and first juvenile stages are exclusively feeding stages. In the present study, the gross morphology and fine structure of the foregut of S. curacaoense were investigated during larval, megalopa and first juvenile stages. The foregut of the zoea I show specific setae and a filter press apparently functional. The foregut undergoes changes in the zoea II (last larval stage) with increment of setae number, mainly on the cardiopyloric valve and complexity of the filter press. After metamorphosis to megalopa stage the foregut become rather complex, with a gastric mill supporting a medial and two lateral teeth well-developed. The foregut of the first juvenile is more specialized compared to the previous stage, showing similar characteristics of the decapod adults. These results provide further evidence of facultative lecithotrophic development in the larvae of S. curacaoense.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a single-phase Series Active Power Filter (Series APF) for mitigation of the load voltage harmonic content, while maintaining the voltage on the DC side regulated without the support of a voltage source. The proposed series active power filter control algorithm eliminates the additional voltage source to regulate the DC voltage, and with the adopted topology it is not used a coupling transformer to interface the series active power filter with the electrical power grid. The paper describes the control strategy which encapsulates the grid synchronization scheme, the compensation voltage calculation, the damping algorithm and the dead-time compensation. The topology and control strategy of the series active power filter have been evaluated in simulation software and simulations results are presented. Experimental results, obtained with a developed laboratorial prototype, validate the theoretical assumptions, and are within the harmonic spectrum limits imposed by the international recommendations of the IEEE-519 Standard.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We evaluated diversity and distribution of fish species in two habitats: flooded forest and open water of lakes of Rio Negro. Each of four lakes within the Anavilhanas Archipelago was sampled three times from 2009-2010. Species diversity generally was higher in flooded forests and at night, according to correspondence analysis. Predators were most active at night, but showed no preference between the flooded forest and open water habitats. Omnivores, filter feeders, and detritivores were most active during the day.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Several suction–water-content (s-w) calibrations for the filter paper method (FPM) used for soil-suction measurement have been published. Most of the calibrations involve a bilinear function (i.e., two different equations) with an inflection point occurring at 60 kPaof various previously published calibrations obtained for filter paper Whatman No. 42 (W42) is presented and discussed. The approach is applied herein to data obtained from three establish bilinear calibrations (six equations) for W42 filter paper to determine the two fitting parameters of the continuous function. An experimental evaluation of the new calibration show that the suctions estimated by the contact FPM test using the proposed function compare well with suctions measured by other laboratory techniques for two different soils for the suction range of 50 kPaof 30 %

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To assess signal-averaged electrocardiogram (SAECG) for diagnosing incipient left ventricular hypertrophy (LVH). METHODS: A study with 115 individuals was carried out. The individuals were divided as follows: GI - 38 healthy individuals; GII - 47 individuals with mild to moderate hypertension and normal findings on echocardiogram and ECG; and GIII - 30 individuals with hypertension and documented LVH. The magnitude vector of the SAECG was analyzed with the high-pass cutoff frequency of 40 Hz through the bidirectional four-pole Butterworth high-pass digital filter. The mean quadratic root of the total QRS voltage (RMST) and the two-dimensional integral of the QRS area of the spectro-temporal map were analyzed between 0 and 30 Hz for the frequency domain (Int FD), and between 40 and 250 Hz for the time domain (Int TD). The electrocardiographic criterion for LVH was based on the Cornell Product. Left ventricular mass was calculated with the Devereux formula. RESULTS: All parameters analyzed increased from GI to GIII, except for Int FD (GII vs GIII) and RMST log (GII vs GIII). Int TD showed greater accuracy for detecting LVH with an appropriate cutoff > 8 (sensitivity of 55%, specificity of 81%). Positive values (> 8) were found in 56.5% of the G II patients and in 18.4% of the GI patients (p< 0.0005). CONCLUSION: SAECG can be used in the early diagnosis of LVH in hypertensive patients with normal ECG and echocardiogram.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This Study assessed the development of sludge treatment and reuse policy since the original 1993 National Sludge Strategy Report (Weston-FTA, 1993). A review of the 48 sludge treatment centres, current wastewater treatment systems and current or planned sludge treatment and reuse systems was carried out Sludges from all Regional Sludge Treatment Centres (areas) were characterised through analysis of selected parameters. There have been many changes to the original policy, as a result of boundary reviews, delays in developing sludge management plans, development in technology and changes in tendering policy, most notably a move to design-build-operate (DBO) projects. As a result, there are now 35 designated Hub Centres. Only 5 of the Hub Centres are producing Class A Biosolids. These are Ringsend, Killamey, Carlow, Navan and Osberstown. Ringsend is the only Hub Centre that is fully operational, treating sludge from surrounding regions by Thermal Drying. Killamey is producing Class A Biosolids using Autothermal Thermophilic Aerobic Digestion (ATAD) but is not, as yet, treating imported sludge. The remaining three plants are producing Class A Biosolids using Alkaline Stabilisation. Anaerobic Digestion with post pasteurisation is the most common form of sludge treatment, with 11 Hub Centres proposing to use it. One plant is using ATAD, two intend to use Alkaline Stabilisation, seven have selected Thermal Drying and three have selected Composting. While the remaining plants have not decided which sludge treatment to select, this is because of incomplete Sludge Management Plans and on DBO contracts. Analysis of sludges from the Hub Centres showed that all Irish sewage sludge is safe for agricultural reuse as defined by the Waste Management Regulations {Use of Sewage Sludge in Agriculture) (S.I. 267/2001), providing that a nutrient management plan is taken into consideration and that the soil limits of the 1998 (S.I. 148/1998) Waste Management Regulations are not exceeded.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Microstrip antenna, Wideband antennas, high gain antennas, Microstrip filters, DGS filters , low-pass filter, band-pass filter

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The freshwater sponges Trochospongilla variabilis Bonetto & Ezcurra de Drago (1973), Radiospongilla crateriformis (Potts, 1882), Spongilla cenota Penney & Racek (1968) and Corvoheteromeyenia heterosclera (Ezcurra de Drago, 1974) compose with the sphaerid bivalve Eupera cubensis (Prime, 1865) and several Phylactolaemata bryozoans a benthic filter feeding community living in seasonal lentic and lotic habitats with high Particulate Organic Carbon (POC), low conductivity and acid pH within the Costa Rica Dry Forest biome. The sponge specimens gathered led to the re-description of the four species.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Quantitative method of viral pollution determination for large volume of water using ferric hydroxide gel impregnated on the surface of glassfibre cartridge filter. The use of ferric hydroxide gel, impregnated on the surface of glassfibre cartridge filter enable us to recover 62.5% of virus (Poliomylitis type I, Lsc strain) exsogeneously added to 400 liters of tap-water. The virus concentrator system consists of four cartridge filters, in which the three first one are clarifiers, where the contaminants are removed physically, without significant virus loss at this stage. The last cartridge filter is impregnated with ferric hydroxide gel, where the virus is adsorbed. After the required volume of water has been processed, the last filter is removed from the system and the viruses are recovered from the gel, using 1 liter of glycine/NaOH buffer, at pH 11. Immediately the eluate is clarified through series of cellulose acetate membranes mounted in a 142mm Millipore filter. For the second step of virus concentration, HC1 1N is added slowly to the eluate to achieve pH 3.5-4. MgC1, is added to give a final concentration of 0.05M and the viruses are readsorbed on a 0.45 , porosity (HA) cellulose acetate membrane, mounted in a 90 mm Millipore filter. The viruses are recovered using the same eluent plus 10% of fetal calf serum, to a final volume of 3 ml. In this way, it was possible to concentrate virus from 400 liters of tap-water, into 1 liter in the first stage of virus concentration and just to 3 ml of final volume in a second step. The efficiency, simplicity and low operational cost, provded by the method, make it feasible to study viral pollution of recreational and tap-water sources.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Cone-beam computed tomography (CBCT) image-guided radiotherapy (IGRT) systems are widely used tools to verify and correct the target position before each fraction, allowing to maximize treatment accuracy and precision. In this study, we evaluate automatic three-dimensional intensity-based rigid registration (RR) methods for prostate setup correction using CBCT scans and study the impact of rectal distension on registration quality. METHODS: We retrospectively analyzed 115 CBCT scans of 10 prostate patients. CT-to-CBCT registration was performed using (a) global RR, (b) bony RR, or (c) bony RR refined by a local prostate RR using the CT clinical target volume (CTV) expanded with 1-to-20-mm varying margins. After propagation of the manual CT contours, automatic CBCT contours were generated. For evaluation, a radiation oncologist manually delineated the CTV on the CBCT scans. The propagated and manual CBCT contours were compared using the Dice similarity and a measure based on the bidirectional local distance (BLD). We also conducted a blind visual assessment of the quality of the propagated segmentations. Moreover, we automatically quantified rectal distension between the CT and CBCT scans without using the manual CBCT contours and we investigated its correlation with the registration failures. To improve the registration quality, the air in the rectum was replaced with soft tissue using a filter. The results with and without filtering were compared. RESULTS: The statistical analysis of the Dice coefficients and the BLD values resulted in highly significant differences (p<10(-6)) for the 5-mm and 8-mm local RRs vs the global, bony and 1-mm local RRs. The 8-mm local RR provided the best compromise between accuracy and robustness (Dice median of 0.814 and 97% of success with filtering the air in the rectum). We observed that all failures were due to high rectal distension. Moreover, the visual assessment confirmed the superiority of the 8-mm local RR over the bony RR. CONCLUSION: The most successful CT-to-CBCT RR method proved to be the 8-mm local RR. We have shown the correlation between its registration failures and rectal distension. Furthermore, we have provided a simple (easily applicable in routine) and automatic method to quantify rectal distension and to predict registration failure using only the manual CT contours.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: EMD 521873 (Selectikine), an immunocytokine comprising a DNA-targeting antibody, aimed at tumour necrosis, fused with a genetically modified interleukin-2 (IL-2) moiety, was investigated in this first-in-human phase I study. METHODS: Patients had metastatic or locally advanced solid tumours failing previous standard therapy. Selectikine was administered as a 1-hour intravenous infusion on 3 consecutive days, every 3weeks. A subgroup of patients also received 300mg/m(2) cyclophosphamide on day 1 of each cycle. Escalating doses of Selectikine were investigated with the primary objective of determining the maximum tolerated dose (MTD). RESULTS: Thirty-nine patients were treated with Selectikine alone at dose levels from 0.075 to 0.9mg/kg, and nine were treated at doses of 0.45 and 0.6mg/kg in combination with cyclophosphamide. A dose-dependent linear increase of peak serum concentrations and area under curve was found. The dose-limiting toxicity was grade 3 skin rash at the 0.9mg/kg dose-level; the MTD was 0.6mg/kg. Rash and flu-like symptoms were the most frequent side-effects. No severe cardiovascular side-effects (hypotension or vascular leak) were observed. At all dose-levels, transient increases in total lymphocyte, eosinophil and monocyte counts were recorded. No objective tumour responses, but long periods of disease stabilisation were observed. Transient and non-neutralising Selectikine antibodies were detected in 69% of patients. CONCLUSIONS: The MTD of Selectikine with or without cyclophosphamide administered under this schedule was 0.6mg/kg. The recommended phase II dose was 0.45-0.6mg/kg. Selectikine had a favourable safety profile and induced biological effects typical for IL-2.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Various methodologies in economic literature have been used to analyse the international hydrocarbon retail sector. Nevertheless at a Spanish level these studies are much more recent and most conclude that generally there is no effective competition present in this market, regardless of the approach used. In this paper, in order to analyse the price levels in the Spanish petrol market, our starting hypothesis is that in uncompetitive markets the prices are higher and the standard deviation is lower. We use weekly retail petrol price data from the ten biggest Spanish cities, and apply Markov chains to fill the missing values for petrol 95 and diesel, and we also employ a variance filter. We conclude that this market demonstrates reduced price dispersion, regardless of brand or city.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Two practical field methods for indirect detection of simuliid populations resistant to temephos are proposed. The first is based on high esterase activity in resistant larvae and involves adaptations of a filter paper test in which faintly stained spots indicate susceptible populations and strongly stained ones reveal populations resistant to temephos. The second is based on the resistance to the larvicide when adults are topically exposed, and involves the use of diagnostic doses obtained by the comparison between the LD50 for susceptible and resistant populations. The relevance of such methods is discussed in order to help resistance detection in Simulium pertinax Kollar control programmes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A heated pheromone trap for the sandfly Lutzomyia longipalpis was tested in the laboratory using filter paper or plastic vial dispensers. Male pheromone extracted from 8 male tergal glands and absorbed on to filter paper dispensers attracted 82/120 (68.3%) of virgin females released in cages. Similarly plastic vial dispensers baited with the extract of 24 males caught 73/120 (61%). In field trials carried out near januária, Minas Gerais, Brazil using the plastic dispensers baited with extracts of 50 male tergal glands only 70 female L. longipalpis were captured. Over 1000 male flies were, however, caught during 6 nights, with greater numbers in the unbaited control traps than in the pheromone baited test traps. It is concluded that at excessive concentrations male L. longipalpis pheromone may act as a repellent to conspecific males.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An active, solvent-free solid sampler was developed for the collection of 1,6-hexamethylene diisocyanate (HDI) aerosol and prepolymers. The sampler was made of a filter impregnated with 1-(2-methoxyphenyl)piperazine contained in a filter holder. Interferences with HDI were observed when a set of cellulose acetate filters and a polystyrene filter holder were used; a glass fiber filter and polypropylene filter cassette gave better results. The applicability of the sampling and analytical procedure was validated with a test chamber, constructed for the dynamic generation of HDI aerosol and prepolymers in commercial two-component spray paints (Desmodur(R) N75) used in car refinishing. The particle size distribution, temporal stability, and spatial uniformity of the simulated aerosol were established in order to test the sample. The monitoring of aerosol concentrations was conducted with the solid sampler paired to the reference impinger technique (impinger flasks contained 10 mL of 0.5 mg/mL 1-(2-methoxyphenyl)piperazine in toluene) under a controlled atmosphere in the test chamber. Analyses of derivatized HDI and prepolymers were carried out by using high-performance liquid chromatography and ultraviolet detection. The correlation between the solvent-free and the impinger techniques appeared fairly good (Y = 0.979X - 0.161; R = 0.978), when the tests were conducted in the range of 0.1 to 10 times the threshold limit value (TLV) for HDI monomer and up to 60-mu-g/m3 (3 U.K. TLVs) for total -N = C = O groups.