897 resultados para Self monitoring blood glycose


Relevância:

30.00% 30.00%

Publicador:

Resumo:

National Highway Traffic Safety Administration, Washington, D.C.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Thesis (Master's)--University of Washington, 2016-06

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to determine the most informative sampling time(s) providing a precise prediction of tacrolimus area under the concentration-time curve (AUC). Fifty-four concentration-time profiles of tacrolimus from 31 adult liver transplant recipients were analyzed. Each profile contained 5 tacrolimus whole-blood concentrations (predose and 1, 2, 4, and 6 or 8 hours postdose), measured using liquid chromatography-tandem mass spectrometry. The concentration at 6 hours was interpolated for each profile, and 54 values of AUC(0-6) were calculated using the trapezoidal rule. The best sampling times were then determined using limited sampling strategies and sensitivity analysis. Linear mixed-effects modeling was performed to estimate regression coefficients of equations incorporating each concentration-time point (C0, C1, C2, C4, interpolated C5, and interpolated C6) as a predictor of AUC(0-6). Predictive performance was evaluated by assessment of the mean error (ME) and root mean square error (RMSE). Limited sampling strategy (LSS) equations with C2, C4, and C5 provided similar results for prediction of AUC(0-6) (R-2 = 0.869, 0.844, and 0.832, respectively). These 3 time points were superior to C0 in the prediction of AUC. The ME was similar for all time points; the RMSE was smallest for C2, C4, and C5. The highest sensitivity index was determined to be 4.9 hours postdose at steady state, suggesting that this time point provides the most information about the AUC(0-12). The results from limited sampling strategies and sensitivity analysis supported the use of a single blood sample at 5 hours postdose as a predictor of both AUC(0-6) and AUC(0-12). A jackknife procedure was used to evaluate the predictive performance of the model, and this demonstrated that collecting a sample at 5 hours after dosing could be considered as the optimal sampling time for predicting AUC(0-6).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Individuals from the same population share a number of contextual circumstances that may condition a common level of blood pressure over and above individual characteristics. Understanding this population effect is relevant for both etiologic research and prevention strategies. Using multilevel regression analyses, the authors quantified the extent to which individual differences in systolic blood pressure (SBP) could be attributed to the population level. They also investigated possible cross-level interactions between the population in which a person lived and pharmacological (antihypertensive medication) and nonpharmacological (body mass index) effects on individual SBP. They analyzed data on 23,796 men and 24,986 women aged 35-64 years from 39 worldwide Monitoring of Trends and Determinants in Cardiovascular Disease (MONICA) study populations participating in the final survey of this World Health Organization project (1989-1997). SBP was positively associated with low educational achievement, high body mass index, and use of antihypertensive medication and, for women, was negatively associated with smoking. About 7-8% of all SBP differences between subjects were attributed to the population level. However, this population effect was particularly strong (i.e., 20%) in antihypertensive medication users and overweight women. This empirical evidence of a population effect on individual SBP emphasizes the importance of developing population-wide strategies to reduce individual risk of hypertension.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: Cyclosporin is an immunosuppressant drug with a narrow therapeutic window. Trough and 2-h post-dose blood samples are currently used for therapeutic drug monitoring in solid organ transplant recipients. The aim of the current study was to develop a rapid HPLC-tandem mass spectrometry (HPLC-MS) method for the measurement of cyclosporin in whole blood that was not only suitable for the clinical setting but also considered a reference method. Methods: Blood samples (50 mu L) were prepared by protein precipitation followed by C-18 solid-phase extraction while using d(12) cyclosporin as the internal standard. Mass spectrometric detection was by selected reaction monitoring with an electrospray interface in positive ionization mode. Results: The assay was linear from 10 to 2000 mu g/L (r(2) > 0.996, n = 9). Inter-day,analytical recovery and imprecision using whole blood quality control samples at 10, 30, 400, 1500, and 2000 mu g/L were 94.9-103.5% and

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To evaluate responses to self-administered brief questions regarding consumption of vegetables and fruit by comparison with blood levels of serum carotenoids and red-cell folate. Design: A cross-sectional study in which participants reported their usual intake of fruit and vegetables in servings per day, and serum levels of five carotenoids (alpha-carotene, beta-carotene, beta-cryptoxanthin, lutein/zeaxanthin and lycopene) and red-cell folate were measured. Serum carotenoid levels were determined by high-performance liquid chromatography, and red-cell folate by an automated immunoassay system. Settings and subjects: Between October and December 2000, a sample of 1598 adults aged 25 years and over, from six randomly selected urban centres in Queensland, Australia, were examined as part of a national study conducted to determine the prevalence of diabetes and associated cardiovascular risk factors. Results: Statistically significant (P < 0.01) associations with vegetable and fruit intake ( categorised into groups: = 4 servings per day) were observed for alpha-carotene, beta-carotene, beta-cryptoxanthin, lutein/zeaxanthin and red-cell folate. The mean level of these carotenoids and of red-cell folate increased with increasing frequency of reported servings of vegetables and fruit, both before and after adjusting for potential confounding factors. A significant association with lycopene was observed only for vegetable intake before adjusting for confounders. Conclusions: These data indicate that brief questions may be a simple and valuable tool for monitoring vegetable and fruit intake in this population.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We observed unexpected high plasma concentrations of tobrarriycin (48.5 and 28.1 mg/L) in fingerprick blood samples after the nebulization of tobramycin solution for inhalation (tobramycin 300 mg/5 mL, TOBI(R)) by 2 young children aged 3 years. To investigate whether dermal contamination could be the source of error, 3 adult volunteers were present during another nebulization by a third child (age 2 years). The volunteers had exposure to tobramycin by handling the nebulizer or the nebule and also by inhalation from holding the child and being in close proximity while TOBI(R) was being administered. Five blood samples by fingerprick and 2 by venipuncture were collected and assayed for tobramycin concentration. On each occasion the site was swabbed with alcohol wipes to mimic standard patient sampling methods. One site was resampled after cleaning of hands with 2% chlorhexidine gluconate and water. Tobramycin concentrations from venipuncture 1-2 hours after nebulization were all < 0.2 mg/L except for 1 result of 1.2 mg/L. The tobramycin concentrations from fingerpricks before hand washing varied between 6.8 and 172 mg/L, and after hand washing between 0.3 and 17.6 mg/L. Contamination of fingers with tobramycin is likely to have caused the error in the 2 initial cases and did cause misleadingly elevated levels in the adult volunteers. We caution that therapeutic drug monitoring of nebulized tobramycin should not be done by fingerprick sampling, and care should be taken to avoid contamination of the venipuncture site.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Although both strength training (ST) and endurance training (ET) seem to be beneficial in type 2 diabetes mellitus (T2D), little is known about post-exercise glucose profiles. The objective of the study was to report changes in blood glucose (BG) values after a 4-month ET and ST programme now that a device for continuous glucose monitoring has become available. Materials and methods Fifteen participants, comprising four men age 56.5 +/- 0.9 years and 11 women age 57.4 +/- 0.9 years with T2D, were monitored with the MiniMed (Northridge, CA, USA) continuous glucose monitoring system (CGMS) for 48 h before and after 4 months of ET or ST. The ST consisted of three sets at the beginning, increasing to six sets per week at the end of the training period, including all major muscle groups and ET performed with an intensity of maximal oxygen uptake of 60% and a volume beginning at 15 min and advancing to a maximum of 30 min three times a week. Results A total of 17 549 single BG measurements pretraining (619.7 +/- 39.8) and post-training (550.3 +/- 30.1) were recorded, correlating to an average of 585 +/- 25.3 potential measurements per participant at the beginning and at the end of the study. The change in BG-value between the beginning (132 mg dL(-1)) and the end (118 mg dL(-1)) for all participants was significant (P = 0.028). The improvement in BG-value for the ST programme was significant (P = 0.02) but for the ET no significant change was measured (P = 0.48). Glycaemic control improved in the ST group and the mean BG was reduced by 15.6% (Cl 3-25%). Conclusion In conclusion, the CGMS may be a useful tool in monitoring improvements in glycaemic control after different exercise programmes. Additionally, the CGMS may help to identify asymptomatic hypoglycaemia or hyperglycaemia after training programmes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Marathon running is growing in popularity, and many diabetic patients are participating in various marathon races all over the world each year. This study aimed to investigate the prevalence and extent of glycemic excursions (hypo- and hyperglycemic) during a marathon run in patients with well-controlled diabetes mellitus using a continuous glucose monitoring system (CGMS). Five subjects with type 1 and one patient with type 2 diabetes mellitus were monitored with the Medtronic MiniMed CGMS during the 2002 Vienna City Marathon (n = 3) or the Fernwarme run (n = 3) long distance runs of 42.19/15.8 km. All six patients finished their course. The CGSM system was well tolerated in all patients over an average duration of 34 +/- 4.0 hours and it did not limit the patients' activities. The mean running time for the Vienna city marathon was 257 +/- 8 min (247 to 274 min) and for the Fernwarme run 134 +/- 118 min (113 to 150 min). A total of 1470 blood glucose measurements (mean 245 readings per subject) were performed. During and after the marathons frequent hypo and hyperglycemic episodes with and without clinical symptoms were measured. Our data confirm that the CGMS may help to identify asymptomatic hypoglycemia or hyperglycemia during and after a long distance run. The system may also be helpful to improve our understanding about the individual changes of glucose during and after a marathon and may protect hypoglycemic or hyperglycemic periods in future races.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Defining the pharmacokinetics of drugs in overdose is complicated. Deliberate self-poisoning is generally impulsive and associated with poor accuracy in dose history. In addition, early blood samples are rarely collected to characterize the whole plasma-concentration time profile and the effect of decontamination on the pharmacokinetics is uncertain. The aim of this study was to explore a fully Bayesian methodology for population pharmacokinetic analysis of data that arose from deliberate self-poisoning with citalopram. Prior information on the pharmacokinetic parameters was elicited from 14 published studies on citalopram when taken in therapeutic doses. The data set included concentration-time data from 53 patients studied after 63 citalopram overdose events (dose range: 20-1700 mg). Activated charcoal was administered between 0.5 and 4 h after 17 overdose events. The clinical investigator graded the veracity of the patients' dosing history on a 5-point ordinal scale. Inclusion of informative priors stabilised the pharmacokinetic model and the population mean values could be estimated well. There were no indications of non-linear clearance after excessive doses. The final model included an estimated uncertainty of the dose amount which in a simulation study was shown to not affect the model's ability to characterise the effects of activated charcoal. The effect of activated charcoal on clearance and bioavailability was pronounced and resulted in a 72% increase and 22% decrease, respectively. These findings suggest charcoal administration is potentially beneficial after citalopram overdose. The methodology explored seems promising for exploring the dose-exposure relationship in the toxicological settings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The self-rating Dysexecutive Questionnaire (DEX-S) is a recently developed standardized self-report measure of behavioral difficulties associated with executive functioning such as impulsivity, inhibition, control, monitoring, and planning. Few studies have examined its construct validity, particularly for its potential wider use across a variety of clinical and nonclinical populations. This study examines the factor structure of the DEX-S questionnaire using a sample of nonclinical (N = 293) and clinical (N = 49) participants. A series of factor analyses were evaluated to determine the best factor solution for this scale. This was found to be a 4-factor solution with factors best described as inhibition, intention, social regulation, and abstract problem solving. The first 2 factors replicate factors from the 5-factor solutions found in previous studies that examined specific subpopulations. Although further research is needed to evaluate the factor structure within a range of subpopulations, this study supports the view that the DEX has the factor structure sufficient for its use in a wider context than only with neurological or head-injured patients. Overall, a 4-factor solution is recommended as the most stable and parsimonious solution in the wider context.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This report describes the case of an 88-year-old non-diabetic female who presented to the emergency department following a presumed hypoijtycaemic collapse due to self-neglect. Subsequent rewarming and resuscitation demonstrated a number of the significant consequences of severe hypothermia, including apparent secondary impairment of glycaemic autoregulation. The phenomenon of reversible inhibition of insulin secretion due to severe hypothermia has been documented previously in the field of cardiac surgery. The hyperglycaemia was not treated with any antihyperglycaernic agent, and her recovery was uneventful. Subsequent blood sugar level monitoring was normal. If insulin is administered to the hypothermic patient, intensive monitoring of blood glucose is essential due to the increase in endogenous insulin secretion on rewarming. (c) 2005 Elsevier Ireland Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE - We examined the associations of physical activity with fasting plasma glucose (FPG) and with 2-h postload plasma glucose (2-h PG) in men and women with low, moderate, and high waist circumference. RESEARCH DESIGN AND METHODS - The Australian Diabetes, Obesity and Lifestyle (AusDiab) study provided data on a population-based cross-sectional sample of 4,108 men and 5,106 women aged >= 25 years without known diabetes or health conditions that could affect physical activity. FPG and 2-h PG were obtained from an oral glucose tolerance test. Self-reported physical activity level was defined according to the current public health guidelines as active (>= 150 min/week across five or more sessions) or inactive (< 150 min/week and/or less than five sessions). Sex-specific quintiles of physical activity time were used to ascertain dose response. RESULTS - Being physically active and total physical activity time were independently and negatively associated with 2-h PG. When physical activity level was considered within each waist circumference category, 2-h PG was significantly lower in active high-waist circumference women (beta-0.30 [95% CI -0.59 to -0.01], P = 0.044) and active low-waist circumference men(beta-0.25 [-0.49 to -0.02],P = 0.036) compared with their inactive counterparts. Considered across physical activity and waist circumference categories, 2-h PG levels were not significantly different between active moderate-waist circumference participants and active low-waist circumference participants. Associations between physical activity and FPG were nonsignificant. CONCLUSIONS - There are important differences between 2-h PG and FPG related to physical activity. It appears that 2-h PG is more sensitive to the beneficial effects of physical activity, and these benefits occur across the waist circumference spectrum.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report here a validated method for the quantification of a new immunosuppressant drug FTY720, using HPLC-tandem mass spectrometry. Whole blood samples (500 mu l) were subjected to liquid-liquid extraction, in the presence of an internal standard (Y-32919). Mass spectrometric detection was by selected reaction monitoring with an atmospheric pressure chemical ionization source in positive ionization mode (FTY720: m/z 308.3 -> 255.3). The assay was linear from 0.2 to 25 mu g/l (r(2) > 0.997, n = 5). The inter- and intra-day analytical recovery and imprecision for quality control samples (0.5, 7 and 15 mu g/l) were 95.8-103.2 and < 5.5%, respectively. At the lower limit of quantification (0.2 mu g/l) the interand intra-day analytical recovery was 99.0-102.8% with imprecision of < 7.6% (n = 5). The assay had a mean relative recovery of 100.5 +/- 5.8% (n = 15). Extracted samples were stable for 16 h. IFTY720 quality control samples were stable at room temperature for 16 h at 4 degrees C for at least 8 days and when taken through at least three freeze-thaw cycles. In conclusion, the method described displays analytical performance characteristics that are suitable for pharmacokinetic studies in humans. (c) 2006 Elsevier B.V. All rights reserved.