997 resultados para Running Efficiency


Relevância:

20.00% 20.00%

Publicador:

Resumo:

An experiment was conducted along the shore of Culasi, Antique in Panay to compare the milkfry (Chanos chanos) catching efficiency of the ordinary fry seine against its innovation and the ordinary sweeper against its 2 modifications. Results show that it is possible to replace the wings of the presently used sweeper and the ends of the fry seine with a coarse-meshed netting. This improvement decreases the water resistance of the gears and thus enables fry gatherers to use larger ones thereby giving more catch.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The filamentous fungus Ashbya gossypii grows into a multicellular mycelium that is distinct from the unicellular morphology of its closely related yeast species. It has been proposed that genes important for cell cycle regulation play central

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Even though it generates healthy adults, nuclear transfer in mammals remains an inefficient process. Mainly attributed to abnormal reprograming of the donor chromatin, this inefficiency may also be caused at least partly by a specific effect of the clonin

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to study of the artificial propagation efficiency in white fish (Coregonus lavaretus) and its fingerlings producing in IRAN, a 9 mounts study project was been done which during it, the characteristics of the matures and brood stocks fishes, the condition of their natural and artificial propagation, and the characteristics of produced frys, were been studied. Throughout the total 82 pieces caught fishes during September til February 2003, 10 pieces of them were the female brood stocks which during the catch time did not have spouse. The study of these fishes showed that there was no significant correlation between their weight and their length. The most and the least absolute fecundity of these brood stocks were 19120 and 11496 respectively. The artificial propagation was been done by 5 males and 4 females broods took which 57602 ova, with 89/2% fertilization rate, earned from them. The incubation period prolonged 55 days in 8°c. At the end of the incubation, 23913 larvae released. So the artificial propagation efficiency was calculated 41/51% in this study. Yolk sack absorption prolonged 4 days. 3 different food treatment were considered for fry breeding which contain of Brachiouns plicatilis as live food, salmon starter food as commercial food, and the mixed of equal amounts of live and commercial foods as third treatment. For each treatment, 3 repeat has been considered. Breeding duration prolonged 13 weeks throughout this period, different characteristics of fry were been studied weekly. The breeding results showed that there was very significant correlation between the weight and the length of frys. However the live food provided better results in growth and survival rate of frys during breeding initial 6 weeks. More ever, commercial food, in some characteristics, provided more acceptable results in comparing the live food after sixth week. The results of this study project showed that the artificial propagation in whitefish is possible in IRAN and the producing of its frys in order to restocking or introducing this species to the other Iranian suitable water resources is executable. Based on the earned information from this study, the suitable time for natural spawning of whitefish in IRAN (Amirkabir dam lake) determined between 10th January til 20th February.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During a two years research hydrogen peroxide efficacy evaluated for Persian sturgeon, Chinese carps and common carp eggs. These series of the experiments conducted in various conditions different concentration of hydrogen peroxide include 250, 500, 750, 1,000 1,500 2,000 3,000 and 9,000 PPM used as ten and fifteen minutes baths, compared with Malachite green and natural control . In the next phase effect of Levaemisole hydrochloride as an immunostimulator which applied as 5 mg/I in twenty minutes baths from day sixth after hatch evaluated by daily mortality rate and leukocytes counts. The results shown that according fertilization percent and temperature condition hydrogen peroxide at 1,000 and 1,500 PPM concentrations is a effective antifungal agent during incubation periods of Persian sturgeon and even sometimes increasing hatching rates significantly comparing with natural controls and Malachite green. In Chinese carps although hydrogen peroxide controls water molds but it is not recommended in high temperatures because it make shortened incubation time and mold infections will decrease. Also the results shown 750 PPM concentration of hydrogen peroxide in common carp eggs controls water moulds infections and increase hatching rate significantly comparing with Malachite green and natural control. Daily mortality rates accessing of Persian sturgeon fries show that 20 minutes baths of 5mg/1 levamisole hydrochloride decreases daily mortality rate during yolk sac absorption. Nitrogenous compounds: nitrate and ammonium differ significantly between treated tanks with control. Blood leucocytes concentrations as an immune index was different significantly in treated fishes by levamisole hydrochloride comparing with controls. In Chinese carps because yolks sac absorption time is short there is not necessary to use the levamisole hydrochloride. Although treated larvae were more active than controls. As a result our suggestions is to use hydrogen peroxide in Persian sturgeon and common carp artificial propagation and also suggest the use levamisole hydrochloride for Persian sturgeon beside management method in stress and pollution condition

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Optimisation of cooling systems within gas turbine engines is of great interest to engine manufacturers seeking gains in performance, efficiency and component life. The effectiveness of coolant delivery is governed by complex flows within the stator wells and the interaction of main annulus and cooling air in the vicinity of the rim seals. This paper reports the development of a test facility which allows the interaction of cooling air and main gas paths to be measured at conditions representative of those found in modern gas turbine engines. The test facility features a two stage turbine with an overall pressure ratio of approximately 2.6:1. Hot air is supplied to the main annulus using a Rolls-Royce Dart compressor driven by an aero-derivative engine plant. Cooling air can be delivered to the stator wells at multiple locations and at a range of flow rates which cover bulk ingestion through to bulk egress. The facility has been designed with adaptable geometry to enable rapid changes of cooling air path configuration. The coolant delivery system allows swift and accurate changes to the flow settings such that thermal transients may be performed. Particular attention has been focused on obtaining high accuracy data, using a radio telemetry system, as well as thorough through-calibration practices. Temperature measurements can now be made on both rotating and stationary discs with a long term uncertainty in the region of 0.3 K. A gas concentration measurement system has also been developed to obtain direct measurement of re-ingestion and rim seal exchange flows. High resolution displacement sensors have been installed in order to measure hot running geometry. This paper documents the commissioning of a test facility which is unique in terms of rapid configuration changes, non-dimensional engine matching and the instrumentation density and resolution. Example data for each of the measurement systems is presented. This includes the effect of coolant flow rate on the metal temperatures within the upstream cavity of the turbine stator well, the axial displacement of the rotor assembly during a commissioning test, and the effect of coolant flow rate on mixing in the downstream cavity of the stator well. Copyright © 2010 by ASME.