1000 resultados para Ressonância paramagnética eletrônica
Resumo:
Diuron (3-(3,4-Dichlorophenyl)-1,1-dimethylurea) is a substituted urea herbicide widely used on agricultural crops such as soy, cotton and sugar cane. In a previous long-term study this herbicide exerted carcinogenic activity on the urinary bladder and renal pelvis mucosa of Wistar rats and breast of mice. Also, it was shown to be carcinogenic to the mice skin in a initiation-promotion assay. In 1997, the northamerican EPA evaluated Diuron as a “known/likely” carcinogen for humans (USEPA, 2004). In a previous study developed at this laboratory, male Wistar rats treated with Diuron 2500 ppm during 20 weeks presented increased indices of cell proliferation and incidences of simple urothelial hyperplasia (HS) in the urinary bladder. Under scanning electron microscopy (SEM) severe urothelial necrosis and hyperplasia were observed. However, in that study the urinary bladders of animals exposed to lower doses of Diuron were not examined under SEM. Therefore, the possible dose-response influence of Diuron on the urothelium under SEM is not known. The present study aimed to analyze under SEM the urinary bladder of male Wistar rats exposed to 125 ppm, 500 ppm and 2500 ppm doses of Diuron through diet during 20 weeks and to compare to the previous histological findings in the same material. Under SEM, 125 ppm and 2500 ppm groups presented significantly (p<0,05) increased incidences of simple hyperplasia, i.e., 7/10 and 8/10 respectively, compared to control group and the 500 ppm group The sensitivity of SEM was higher since it detected a 45% incidence of hyperplasiaswhile the histological analysis found only 27%. Considering SEM as the gold-standard, histology showed a 44% sensitivity, 86.4% specificity, a positive predictive value of 72,7% and negative predictive value of 65,5% and accuracy of 67,5%. Scanning Electron Microscopy...(Complete abstract click electronic access below)
Resumo:
In our experiments, we studied the classical dynamic of a particle in vertical motion subject to a constant gravitational field and the partial shock with an elastic wall with oscillatory motion located below the particle. The motion of the particle was confined to the vertical direction by a glass guide tube, which was initially evacuated, allowing viscous drag forces to be disregarded. The time between impacts, as well as the time between the reference phase of the movement of the base and the moment of impact and the period of oscillation of the base will be acquired by a hardware and software to obtain the phases space to be compared later with the description of the system through mapping discrete variables via the 'particle velocity immediately after shock 'and' phase of the movement of the base at the instant of shock 'obtained by computer simulation. This requires developing an electronic analog system followed by Digital implemented in reconfigurable logic, more specifically a sequential machine able to discriminate the impact with the metal base from the impacts of the glass guide tube, based on the frequency spectrum of the response of the microphone to these different impacts
Resumo:
Magnetic resonance imaging (MRI), which is studied since 1938, is a technique used in medicine to produce high quality images from inside the human body. These images are produced non-invasively and without ionizing radiation. In addition, MRI is an extremely flexible technique, with which it is possible to produce images with different contrasts that provide different information about the anatomy, structure and function of the human body, and it is therefore one of the techniques preferred by radiologists. The phenomenon of MRI is based on the interaction of magnetic fields with the nuclear spins of the scanned sample. In this work a detailed study of the technique of magnetic resonance imaging is presented, with a description of the main features of the images produced by the technique and an analysis of its application to the fields of applications Neurology and Neuroscience
Resumo:
By the early 20th century, the blood vessels could only be seen by anatomical studies. Shortly after the discovery of X-rays by Conrad Roentgen in 1895, the first experiments with radiographic imaging were performed with blood vessels. In 1905, the first experiment involving catheterization of arterial and venous system in dogs was performed and only in 1914 performed on living human patients. Parallel to these landmarks, there were advances in diagnostic imaging devices and the evolution of contrast substances was of utmost importance to the current angiography occupy a prominent role not only in terms of diagnosis, but also in the treatment of various disorders. The main objective of this review is to weave historical considerations and comparisons between the different methodologies used in angiography, because its importance; that may be in future, a veterinary diagnostic decisive test
Resumo:
The plasma represents a average of the information referring biochemists to the physiology of the organism as a whole, therefore it indirectly or directly interacts with all tissues of the body. In such a way the plasma can be considered as a metabolic “soup”. Using the Nuclear Magnetic Resonance Spectroscopy sanguineous plasma spectra had been generated and using deconvolution techniques it was possible to know the contribution of the albumin for the formation of the spectra of the sanguineous plasma
Resumo:
Devido a grande demanda do uso da energia atômica, as pesquisas sobre o processo de separação de isótopos tornam-se cada vez mais importantes. Neste trabalho mostramos uma técnica de separação de isótopos usando o efeito da ressonância.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Bases Gerais da Cirurgia - FMB
Resumo:
This project developed microstructural characterization technics of commercial dualphase and multi-phasic (TRIP) steels that were provided by the automotive industry and are currently used as the raw material for the production of automobiles. Inserted in this context, there is the development of the advanced high strength steels in consonance with the ULSABAVC project, which aims the production of safe, economically viable and efficient in terms of fuel consumption vehicles for the 21st century. The micro-structural characterization of biphasic and multiphase steels was done by the identification and quantification of the coexistent phases. In this item, a special attention was given to the technics that were performed using optic microscopy and scanning electron microscopy. An important contribution to this work was the utilization of different alternative chemical reagents (Beraha, Heat-Tinting technics) in addition to the classical ones (Nital and LePera)already used conventionally by the UNESP's Group of Mechanical, Microstructural and Fractografic Characterization of Materials. The revealed microstructures were correlated with the materials' mechanical properties determined through traction tests, such as ultimate tensile strengths, yield strength and stretching important since the material has structural application in the automotive industry. As a result, it was observed the superiority concerning the studied mechanical properties for the biphasic and multiphasic steels when compared to the conventional carbon steels. Besides, it was perceived a large potential for the industrial scale utilization of the Heat Tinting technics in this field, seen its differentiation of the existent phases and easy reproducibility
Resumo:
Pós-graduação em Química - IQ
Resumo:
This paper presents a case report with the use of short dental implants and immediate prosthesis placement. After 13 months of follow-up, peri-implant probing values are near 1.87 mm and ISQ values around 78.56.
Resumo:
Pós-graduação em Ciência dos Materiais - FEIS
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Odontologia - FOAR
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)