987 resultados para Rectum prosthesis
Resumo:
BACKGROUND: Aortoplasty has been advocated for moderate dilatation of the ascending aorta associated with aortic valve disease. We report our results with this conservative approach. METHODS: Seventeen consecutive patients with unsupported aortoplasty were reviewed. Twelve patients had aortic valve regurgitation and 5 had stenosis. The aortic wall was analyzed histologically in 14 patients. Follow-up was complete, with a mean time of 6 years (range, 2.3 to 10.5 years). RESULTS: Two patients among the 15 hospital survivors died during follow-up of causes unrelated to aortic pathology. Survival at 7 years was 86.7% (+/- 8.8%). Recurring aortic aneurysms developed in 4 patients after a mean time of 63 months, with an event-free survival at 7 years of 41% (+/- 21%). All of these 4 patients had aortic valve regurgitation and cystic medial necrosis. CONCLUSIONS: The recurrence rate of aneurysms after unsupported aortoplasty and aortic valve replacement is high in patients with aortic regurgitation. This strongly suggests that in these patients, the aortic dilatation is related to an underlying wall deficiency, associated with the aortic valve pathology, rather than to the hemodynamic stress imposed by the aortic valve disease.
Resumo:
Total knee arthroplasty (TKA) remains the preferred treatment for patients with invalidating osteoarthritis. It allows these patients to find once again a satisfactory quality of life. These results are reflected by the increasing number of interventions performed each year and in always younger patients. The objective of this review of the scientific literature was to determine the long-term quantitatively and qualitatively results of TKA and determine the parameters which could influence the long-term outcome. There does not seem to be any clear arguments in favor of one type of implant or surgical technique. One also notices that TKA in females and older patients seem to have longer lifespan, estimated to approximately 15 years. The most frequent complication remains aseptic loosening followed by infections.
Resumo:
INTRODUCTION: This trial randomly assessed short-term adjuvant hormonal therapy added to radiotherapy (RT) for intermediate- and high-risk (UICC 1997 cT2a or cT1b-c with high PSA or Gleason score) localised prostate cancer. We report acute toxicity (CTCAE v2) assessed weekly during RT in relation to radiation parameters. PATIENTS AND METHODS: Centres selected the RT dose (70, 74 or 78Gy) and RT technique. Statistical significance is at 0.05. RESULTS: Of 791 patients, 652 received 3D-CRT (70Gy: 195, 74Gy: 376, 78Gy: 81) and 139 received IMRT (74Gy: 28, 78Gy: 111). During RT, grade 3 gastrointestinal (GI) and genitourinary (GU) toxicities were reported by 7 (0.8%) and 50 (6.3%) patients, respectively. No grade 4 was reported. The risk of grade 2 GI toxicity increased significantly with increasing D50%-rectum (p=0.004) and that of grade 2 GU toxicity correlated only to Dmax-bladder (p=0.051). 3D-RT technique, increasing total dose and V95% >400 cc increased D50% and Dmax. One month after RT, only 14 patients (1.8%) reported grade 3 toxicity. AST did not seem to influence the risk of GU or GI acute toxicity. CONCLUSION: RT up to 78Gy was well tolerated. Dmax-bladder and D50%-rectum influenced the risk of grade 2 GU toxicity and GI toxicity, respectively. Both were lower with IMRT but remained high for an irradiated RT volume>400 cc for 3D-RT and for a dose of 78Gy. Hormonal treatment did not influence acute toxicity.
Resumo:
BACKGROUND: Total orbital exenteration is a radical surgical procedure, which typically involves the removal of the entire contents of the orbit including the periorbita, leaving the patient with a deep orbital deformity and results in devastating cosmetic, functional, and psychological consequences requiring difficult and challenging procedures for oculoplastic surgeons. Oculofacial prostheses retained by endosseous dental implants present an attractive and viable alternative when aesthetic and functional demands are beyond the capacity of local reconstructive efforts. PATIENTS AND METHODS: A 72-year-old woman presenting a malignant melanoma of the right eyelids and a 77-year-old man presenting a sebaceous carcinoma of the left upper eyelid underwent a total exenteration followed by positioning of endosseous implants (Straumann system Dental implants) as an integrated one-step combined surgical procedure. The oculofacial prosthesis was placed after epithelialization of the orbital cavity. RESULTS: The implants were perfectly osseointegrated without any complications, providing sufficient retention of the prostheses. A satisfactory aesthetic outcome has been achieved for both patients. CONCLUSIONS: Oculofacial prostheses anchored by osseointegrated dental implants placed as one-step surgical procedure ensure an adequate aesthetic result as well as a considerably decreased rehabilitation time and present a satisfactory solution when reconstruction is not a suitable option.
Resumo:
PURPOSE: Controversy still exists as to the best surgical treatment for periprosthetic shoulder infections. The aim of this multi-institutional study was to review a continuous retrospective series of patients treated in four European centres and to assess the respective eradication rate of various treatment approaches. METHODS: Forty-four patients were available for this retrospective follow-up evaluation. Functional and clinical evaluation of treatment for infection was performed using the Constant-Murley score, visual analogue scale and patient satisfaction Neer score. Erythrocyte sedimentation rate, serum leucocyte count and C-reactive protein were measured and shoulder X-ray examination performed prior to surgery and at the latest follow-up. RESULTS: At a mean follow-up of 41 months (range 24-98), 42 of 44 patients (95.5%) showed no signs of infection recurrence/persistence. Comparable eradication rates were observed after resection arthroplasty (100%; 6/6), two-stage revision (17/17) or permanent antibiotic-loaded spacer implant (93.3%; 14/15). No patient was treated by one-stage revision. On average, both functional and pain scores improved significantly; the worst joint function was observed after resection arthroplasty. CONCLUSIONS: This retrospective analysis conducted on the largest published series of patients to date shows comparable infection eradication rates after two-stage revision, resection arthroplasty or permanent spacer implant for the treatment of septic shoulder prosthesis.
Resumo:
This study compared the outcome of total knee replacement (TKR) in adult patients with fixed- and mobile-bearing prostheses during the first post-operative year and at five years' follow-up, using gait parameters as a new objective measure. This double-blind randomised controlled clinical trial included 55 patients with mobile-bearing (n = 26) and fixed-bearing (n = 29) prostheses of the same design, evaluated pre-operatively and post-operatively at six weeks, three months, six months, one year and five years. Each participant undertook two walking trials of 30 m and completed the EuroQol questionnaire, Western Ontario and McMaster Universities osteoarthritis index, Knee Society score, and visual analogue scales for pain and stiffness. Gait analysis was performed using five miniature angular rate sensors mounted on the trunk (sacrum), each thigh and calf. The study population was divided into two groups according to age (≤ 70 years versus > 70 years). Improvements in most gait parameters at five years' follow-up were greater for fixed-bearing TKRs in older patients (> 70 years), and greater for mobile-bearing TKRs in younger patients (≤ 70 years). These findings should be confirmed by an extended age controlled study, as the ideal choice of prosthesis might depend on the age of the patient at the time of surgery.
Resumo:
Aortic stenosis mostly occurs among old-old patients. Once symptoms appear, prognosis is guarded, with 2-year mortality as high as 50%. Transcatheter Aortic Valve Implantation (TAVI) is a new therapeutic option in patients at very high surgical risk, who are mostly older persons. However, TAVI is associated with some complications, and patient selection remains a challenge. Comprehensive geriatric assessment (CGA) identifies patients with medical and functional problems likely to affect the TAVI post-operative course. Collaboration between cardiologists and geriatricians will likely become a standard approach to enhance the assessment of these frail patients and identify those most likely to benefit from TAVI.
Resumo:
El ligamento escafolunar es uno de los ligamentos que se halla intraarticular, entre el escafoides y el semilunar. Su función más importante es evitar que ambos huesos se separen cuando se cierra firmemente el puño, en la prono-supinación de la mano sobre el eje del antebrazo y durante la flexo-extensión de la muñeca. La indicación terapéutica para reparar la inestabilidad consiste en la cirugía de reconstrucción, mediante la transferencia de tendones, la fusión de las articulaciones o la reformación de los huesos. Actualmente existen dos métodos quirúrgicos para la reparación del ligamento.Para evitar la cirugía abierta, con el presente proyecto se pretende encontrar una solución que permita, a través de una cirugía con artroscopia, solucionar el problema mediante la implantación de una prótesis
Resumo:
After cemented total hip arthroplasty (THA) there may be failure at either the cement-stem or the cement-bone interface. This results from the occurrence of abnormally high shear and compressive stresses within the cement and excessive relative micromovement. We therefore evaluated micromovement and stress at the cement-bone and cement-stem interfaces for a titanium and a chromium-cobalt stem. The behaviour of both implants was similar and no substantial differences were found in the size and distribution of micromovement on either interface with respect to the stiffness of the stem. Micromovement was minimal with a cement mantle 3 to 4 mm thick but then increased with greater thickness of the cement. Abnormally high micromovement occurred when the cement was thinner than 2 mm and the stem was made of titanium. The relative decrease in surface roughness augmented slipping but decreased debonding at the cement-bone interface. Shear stress at this site did not vary significantly for the different coefficients of cement-bone friction while compressive and hoop stresses within the cement increased slightly.
Resumo:
The prescribing of antibiotics for uncomplicated skin abscesses and diverticulitis has no benefit. Some antibiotics are more at risk of causing a Clostridium difficile infection. The tests used to exclude a history of a penicillin allergy are safe. A threshold of D-dimer adjusted for the age significantly improves the specificity of the test without affecting the sensitivity. The prescription of paraclinics tests is not an effective "treatment" for the patient's anxiety. In the sleep apnea syndrome, treatment with CPAP (Continuous positive airway pressure) appears to have more benefits compared to the mandibular advancement prosthesis. The work of primary care physicians can be supported by the work of advanced practice nurses. The limitation placed on the working hours of doctors in hospitals seems to affect their ability to spend time with their patients.
Resumo:
A periprosthetic fracture is a fracture around or in proximity of a prosthetic implant. As more and more prostheses are implanted, the incidence of periprosthetic fractures also increases. Several risk factors have been outlined, some due to the patient, and some due to the implant itself. Key points in diagnosis are the case history and the imaging, as they allow the distinction between a well-fixed and a loose prosthesis. Correct classification is crucial for the treatment choice, which can be non-operative or consist in an osteosynthesis or in a revision arthroplasty, depending on the patient's general medical condition and the local status.
Resumo:
There is increasing evidence that modular neck stems are prone to corrosion-related complications. Recent studies showed elevated metal ions levels and occasional pseudotumor formation in patients with such implants. The purpose of this study was to compare systemic metal-ion levels in patients after primary THA with modular neck stems to those of patients after non-modular implants. To our knowledge, this is the first cohort study including a control group, THA without CoCr heads and dry-assembled neck-stem connections. Methods: 50 patients after THA at a minimum follow-up of 1 year have been selected for the study. Patients with multiple prosthesis or other implants have been deselected. All received a cementless SPS stem from Symbios (Ti6Al4V). 40 patients have the modular neck (CoCr) version and 10 a monobloc version. All bearings were either ceramic-ceramic or ceramic-polyethylene to minimize other sources of CoCr ion release. In the modular group, the neck was chosen pre-operatively based on a 3D planning, allowing for a dry assembly of the stem and neck on the back table before implantation. A plasma system coupled to mass spectrometry was used for a complete elementary quantification in blood and serum separately. Clinical outcome was measured using the Oxford Hip Score. Results : Complete data sets of 29 patients (24 in the modular neck-group (10male, mean age 63y, 35-84y) and 5 in the monobloc-group (3 male, 69 y, 51-83y) are available to date. Mean Co blood levels were .95 ug/L (.14-12.4) in the modular group vs .27 ug/L (.10-.73) in the monobloc group (p=.2). Respective values for Cr were significantly higher in the modular group (.99 g/L; range .75-1.21) compared to those in the monobloc group (.74 g/L ;.62-.86; p=.001). No significant difference was found when comparing serum levels. 5/24 patients had Co levels above 1 g/L (12/24 for Cr), which is by some considered as a relevant elevation. The maximum Co level was measured in an asymptomatic patient. The Oxford Hip Scores were similar in both groups. Conclusion: Cr levels were significantly elevated in the modular neck group compared to those in the monobloc group. 1/24 patients with a modular prosthesis exhibited Co levels, which are beyond the threshold accepted even for metal-on-metal bearing couples. These results have contributed to our decision to abandon the use of modular neck stems. Routine follow-up including annual measurements of systemic CoCr concentrations should be considered.
Resumo:
The microbiological diagnosis of periprosthetic joint infection (PJI) is crucial for successful antimicrobial treatment. Cultures have limited sensitivity, especially in patients receiving antibiotics. We evaluated the value of multiplex PCR for detection of microbial DNA in sonication fluid from removed orthopedic prostheses. Cases of PJI in which the prosthesis (or part of it) was removed were prospectively included. The removed implant was sonicated, and the resulting sonication fluid was cultured and subjected to multiplex PCR. Of 37 PJI cases (17 hip prostheses, 14 knee prostheses, 4 shoulder prostheses, 1 elbow prosthesis, and 1 ankle prosthesis), pathogens were identified in periprosthetic tissue in 24 (65%) cases, in sonication fluid in 23 (62%) cases, and by multiplex PCR in 29 (78%) cases. The pathogen was detected in 5 cases in sonication fluid only (Propionibacterium acnes in all cases; none of these patients had previously received antibiotics) and in 11 cases by multiplex PCR only (all of these patients had previously received antibiotics). After exclusion of 8 cases caused by P. acnes or Corynebacterium species, which cannot be detected due to the absence of specific primers in the PCR kit, sonication cultures were positive in 17 cases and multiplex PCR sonication cultures were positive in 29 cases (59% versus 100%, respectively; P < 0.01). Among 19 cases (51%) receiving antibiotics, multiplex PCR was positive in all 19 (100%), whereas sonication cultures grew the organism in 8 (42%) (P < 0.01). Multiplex PCR of sonication fluid is a promising test for diagnosis of PJI, particularly in patients who previously received antibiotics. With modified primer sets, multiplex PCR has the potential for further improvement of the diagnosis of PJI.
Resumo:
Introduction: The overeruption of upper molars due to the premature loss of antagonist teeth can be treated with the help of miniscrews. The aim of this study was to evaluate the movement of a typodont molar according to the biomechanical approach used with miniscrews. Study design: The study was conducted with four plaster models filled with typodont wax. In each model we used one absolute anchorage on the palatal side and another on the buccal side in different positions, thus generating four different biomechanical systems. A force of 150 g was applied to each side of the resin tooth. Periapical radiographs were taken preintrusion and immediately after completion of the intrusion. Photographs were taken in both the sagittal and occlusal planes every 3 min. The radiographic films and photographs were measured and compared. Results: A vertical movement of the molar was observed in all the models, with system 4 showing the greatest movement. Rotation in the occlusal plane only occurred in system 2, while in system 1 there was a change in the axial axis of 37 degrees. Conclusions: The anchorage site and the combination of forces applied may determine the resulting tooth movement
Resumo:
Open surgery is still the main treatment of complex abdominal aortic aneurysm. Nevertheless, this approach is associated with major complications and high mortality rate. Therefore the fenestrated endograft has been used to treat the juxtarenal aneurysms. Unfortunately, no randomised controlled study is available to assess the efficacy of such devices. Moreover, the costs are still prohibitive to generalise this approach. Alternative treatments such as chimney or sandwich technique are being evaluated in order to avoid theses disadvantages. The aim of this paper is to present the endovascular approach to treat juxtarenal aneurysm and to emphasize that this option should be used only by highly specialized vascular centres.