919 resultados para Ready-made
Resumo:
Indium-tin oxide nanowires were deposited by excimer laser ablation onto catalyst-free oxidized silicon substrates at a low temperature of 500 degrees C in a nitrogen atmosphere. The nanowires have branches with spheres at the tips, indicating a vapor-liquid-solid (VLS) growth. The deposition time and pressure have a strong influence on the areal density and length of the nanowires. At the earlier stages of growth, lower pressures promote a larger number of nucleation centers. With the increase in deposition time, both the number and length of the wires increase up to an areal density of about 70 wires/mu m(2). After this point all the material arriving at the substrate is used for lengthening the existing wires and their branches. The nanowires present the single-crystalline cubic bixbyite structure of indium oxide, oriented in the [100] direction. These structures have potential applications in electrical and optical nanoscale devices.
Resumo:
Introduction: The purpose of this study was to use photoelastic analysis to compare the system of forces generated by retraction T-loop springs made with stainless steel and titanium-molybdenum alloy (TMA) (Ormco, Glendora, Calif) with photoelastic analysis. Methods: Three photoelastic models were used to evaluate retraction T-loop springs with the same preactivations in 2 groups. In group 1, the loop was constructed with a stainless steel wire, and 2 helicoids were incorporated on top of the T-loop; in group 2, it was made with TMA and no helicoids. Results: Upon using the qualitative analysis of the fringe order in the photoelastic model, it was observed that the magnitude of force generated by the springs in group 1 was significantly higher than that in group 2. However, both had symmetry for the active and reactive units related to the system of force. Conclusions: Both springs had the same mechanical characteristics. TMA springs showed lower force levels. (Am J Orthod Dentofacial Orthop 2011;140:e123-e128)
Resumo:
We have studied the alkaline ribonuclease (RNase) activity in maternal serum and serum of full-term small- (T-SGA), full-term appropriate- (T-AGA) and preterm appropriate-for-gestational age (PT-AGA) newborns. A significantly lower level of RNase was observed in T-AGA and T-SGA newborns on the 30th day of age and in PT-AGA newborns on the 15th and 30th days of age, as compared to other T-AGA, T-SGA and PT-AGA groups of infants at birth. RNase activity was significantly higher in cord blood than in the maternal blood in all categories studied. Moreover, in preterm newborns, RNase activity in cord blood was significantly higher in those presenting a lower gestational age. We did not observe any significant difference in RNase levels in the cord blood of newborns from the 3 categories studied. The same results were observed concerning maternal blood. We, therefore, conclude that RNase activity in cord blood or in maternal blood is not a very statisfactory indicator of fetal malnutrition.
Resumo:
The nutritional management of infants admitted with diarrhoea to the University Hospital of Botucatu includes a change from bolus feeding of a modulated minced-chicken formula to a continuous nasogastric drip (NGD) feeding, whenever the required calorie intake is not achieved or the diarrhoea does not subside. To evaluate this approach, the clinical course and weight changes of 63 children, aged 1-20 months, were reviewed; most (81 per cent) were below the third percentile for weight at admission and 76 per cent had a total duration of diarrhoea ≥10 days. Associated infections, mainly systemic, were present at or after admission in 70 per cent of them. Twenty-five survivors needed nutritional support (NS), predominantly NGD, for a median duration of 30 per cent of their admission time, and were compared to 31 survivors managed without NS. Those who necessitated NS lost weight for a significantly longer median time (12x4 days, p<0.005), but their total weight loss was similar (5x4 per cent) as well as diarrhoea's duration (8x7 days). There was a tendency for a longer hospitalization (21x16 days 0.05
Resumo:
A polymeric precursor solution was employed in preparing SrBi2Nb2O9 (SBN) powder and thin films dip coated onto Si(100) substrate. XRD results show that the SBN perovskite phase forms at temperatures as low as 600°C through an intermediate fluorite phase. This fluorite phase is observed for samples heat-treated at temperatures of 400 and 500°C. After heat treatment at temperatures ranging from 300 to 800°C, thin films were shown to be crack free. Grazing incident angle XRD characterization shows the occurrence of the fluorite intermediate phase for films also. The thickness of films, measured by MEV, was in the order of 80-100 nm.
Resumo:
In anuran amphibian Scinax fuscovarius, the spermatogenesis occurs in structures called seminiferous loculi, in which germ epithelium is organized in spermatocysts. Each cyst contains cells in the same stage of cytodifferentiation. Characteristics of each cellular type and their groups made the identification and differentiation of the germ lineage cells possible. In the basis of the epithelium there are the spermatogonia I, the biggest cells and always associated with the Sertoli cell. After the phase of mitotic proliferation, the cysts containing variable number of spermatogonia II are originated, quite smaller and with cellular boundaries a little distinct. After differentiation and growth in volume, the spermatocytes I appear, the nuclei of which are spherical and with different degrees of compaction of the nuclear material. Starting the meiotic process, the spermatocytes II are originated, which by means of the second meiotic division become haploid cells, the spermatids I. These two last spermatocysts are very similar. In this phase, the cells will go through a prominent process of differentiation until they form the spermatids II, which are elongated and begin to be organized in bundles supported by prominent Sertoli cells. With the process of spermiogenesis, spermatozoa appear, usually observed in compact bundles with tails turned to the lumen and their heads fitted in their support cells. In more advanced stages, the spermatozoa can be observed free in the locular lumen, ready to follow the spermatic path.
Resumo:
The purpose of this work was to study the influence of carrageenan level (X 1) and total solids content of yogurt/whey mixture (X 2) on starter culture fermentation time, physicochetnical properties (pH, fat and total solids contents) and rheological characteristics of lactic beverages using response surface methodology. The physicochemical characteristics of the lactic beverages were similar to those of commercial products. All beverages showed non-Newtonian fluid behavior with thixotropy and yield stress. The total solids content of the lactic beverages had a greater influence on the rheological behavior of these products than the carrageenan level. Wide ranges of consistency measurements were observed by varying the stabilizer level and total solids content.
Resumo:
The aim of this study was to determine the cutting ability of chemical vapor deposition (CVD) diamond burs coupled to an ultrasonic dental unit handpiece for minimally invasive cavity preparation. One standard cavity was prepared on the mesial and distal surfaces of 40 extracted human third molars either with cylindrical or with spherical CVD burs. The cutting ability was compared regarding type of substrate (enamel and dentin) and direction of handpiece motion. The morphological characteristics, width and depth of the cavities were analyzed and measured using scanning electron micrographs. Statistical analysis using the Kruskal-Wallis test (p < 0.05) revealed that the width and depth of the cavities were significantly greater when they were prepared on dentin. Wider cavities were prepared when the cylindrical CVD bur was used, and deeper cavities resulted from preparation with the spherical CVD bur. The direction of handpiece motion did not influence the size of the cavities, and the CVD burs produced precise and conservative cutting.
Resumo:
Purpose: This study compared the shear bond strength (SBS) to enamel of rest seats made with a glass-ionomer cement (Fuji IX GP Fast), a resin-modified glass-ionomer cement (Fuji II LC), and a composite resin (Z100 MP) under monotonic and cyclic loading. Materials and Methods: Rest seats were built up onto the lingual surfaces of 80 intact human mandibular incisors. Specimens (n=10) were stored in distilled water at 37°C for 30 days and subjected to shear forces in a universal testing machine (0.5 mm/min) until fracture. The SBS values were calculated (MPa) using the bonding area (9.62 mm2) delimited by adhesive tags. A staircase approach was used to determine the SBS fatigue limit of each material. Specimens were submitted to either 10,000 cycles (5 Hz) or until specimen fracture. A minimum of 15 specimens was tested for each material. Scanning electron microscopy was used to examine the mode of failure. Data were statistically analyzed with one-way ANOVA and Tukey HSD tests (α = 0.05). Results: Z100 MP yielded higher (p < 0.05) SBS (12.25 MPa) than Fuji IX GP Fast (7.21 MPa). No differences were found between Fuji II LC (10.29 MPa) and the other two materials (p > 0.05). Fuji II LC (6.54 MPa) and Z100 MP (6.26 MPa) had a similar SBS limit. Fuji IX GP Fast promoted the lowest (p < 0.05) SBS fatigue limit (2.33 MPa). All samples showed cohesive failure patterns. Conclusion: Fatigue testing can provide a better means of estimating the performance of rest seats made with dental restoratives.
Resumo:
A green ceramic tape micro heat exchanger was developed using LTCC technology. The device was designed by using a CAD software and 2D and 3D simulations using a CFD package (COMSOL Multiphysics) to evaluate the fluid behavior in the microchannels. The micro heat exchanger is composed of five thermal exchange plates in cross flow arrangement and two connecting plates; heat exchanger dimensions are 26 × 26 × 6 mm3. Preliminary tests were carried out to characterize the device both in atmospheric pressure and in vacuum. The same techniques used in vacuum technology were applied to check the rotameters and to prevent device leakages. Thermal performance of the micro heat exchanger was experimentally tested. © 2009 Elsevier B.V. All rights reserved.
Resumo:
Studies of the band gap properties of one-dimensional superlattices with alternate layers of air and left-handed materials are carried out within the framework of Maxwell's equations. By left-handed material, we mean a material with dispersive negative electric and magnetic responses. Modeling them by Drude-type responses or by fabricated ones, we characterize the n(ω) = 0 gap, i.e., the zeroth order gap, which has been predicted and detected. The band structure and analytic equations for the band edges have been obtained in the long wavelength limit in case of periodic, Fibonacci, and Thue-Morse superlattices. Our studies reveal the nature of the width of the zeroth order band gap, whose edge equations are defined by null averages of the response functions. Oblique incidence is also investigated, yielding remarkable results. © 2010 Springer Science+Business Media B.V.
Resumo:
The aim of this study was to evaluate the influence of 2 different surface polishing procedures - glazing (GZ) and manual polishing (MP) - on the roughness of ceramics processed by computer-aided design/computer-aided manufacturing (CAD/CAM) and conventional systems (stratification technique). Eighty ceramic discs (diameter: 8 mm, thickness: 1 mm) were prepared and divided among 8 groups (n = 10) according to the type of ceramic disc and polishing method: 4 GZ and 4 MP. Specimens were glazed according to each manufacturer's recommendations. Two silicone polishing points were used on the ceramic surface for manual polishing. Roughness was measured using a surface roughness tester. The roughness measurements were made along a distance of 2 mm on the sample surface and the speed of reading was 0.1 mm/s. Three measurements were taken for each sample. The data (μm) were statistically analyzed using analysis of variance (ANOVA) and Tukey's test (α = 0.05). Qualitative analysis was performed using scanning electron microscopy (SEM). The mean (± SD) roughness values obtained for GZ were: 1.1 ± 0.40 μm; 1.0 ± 0.31 μm; 1.6 ± 0.31 μm; and 2.2 ± 0.73 μm. For MP, the mean values were: 0.66 ± 0.13 μm; 0.43 ± 0.14 μm; 1.6 ± 0.55 μm; and 2.0 ± 0.63 μm. The mean roughness values were significantly affected by the ceramic type (P = 0.0001) and polishing technique (P = 0.0047). The SEM images confirmed the roughness data. The manually polished glass CAD/CAM ceramics promoted lower surface roughness than did the glazed feldspathic dental ceramics.