922 resultados para Radius of Convexity


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Polymer based wicking structures were fabricated by sintering powders of polycarbonate (PC), ultra-high molecular weight polyethylene and polyamide 12, aiming at selecting a suitable material for an innovative electroencephalography (EEG) bio-electrode. Preliminary experiments showed that PC based wicks displayed the best mechanical properties, therefore more detailed studies were carried out with PC to evaluate the influence of powder granulometry and processing parameters (pressure, temperature and time) on the mechanical properties, porosity, mean pore radius and permeability of the wicks. It was concluded that the mechanical properties are significantly enhanced by increasing the processing time and pressure, although at the expense of a significant decrease of porosity and mean pore diameter (and thus permeability), particularly for the highest applied pressures (74kPa). However, a good compromise between porosity/permeability and mechanical properties could be obtained by sintering PC powders of particle sizes below 500μm at 165°C for 5min, upon an applied pressure of 56kPa. Moreover, PC proved to be chemically stable in contact with an EEG common used disinfectant. Thus, wicking structures with appropriate properties for the fabrication of reusable bio-electrodes could be fabricated from the sintering of PC powders.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The inclusive jet cross-section is measured in proton--proton collisions at a centre-of-mass energy of 7 TeV using a data set corresponding to an integrated luminosity of 4.5 fb−1 collected with the ATLAS detector at the Large Hadron Collider in 2011. Jets are identified using the anti-kt algorithm with radius parameter values of 0.4 and 0.6. The double-differential cross-sections are presented as a function of the jet transverse momentum and the jet rapidity, covering jet transverse momenta from 100 GeV to 2 TeV. Next-to-leading-order QCD calculations corrected for non-perturbative effects and electroweak effects, as well as Monte Carlo simulations with next-to-leading-order matrix elements interfaced to parton showering, are compared to the measured cross-sections. A quantitative comparison of the measured cross-sections to the QCD calculations using several sets of parton distribution functions is performed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Double-differential three-jet production cross-sections are measured in proton--proton collisions at a centre-of-mass energy of s√=7TeV using the ATLAS detector at the Large Hadron Collider. The measurements are presented as a function of the three-jet mass (mjjj), in bins of the sum of the absolute rapidity separations between the three leading jets (|Y∗|). Invariant masses extending up to 5 TeV are reached for 8<|Y∗|<10. These measurements use a sample of data recorded using the ATLAS detector in 2011, which corresponds to an integrated luminosity of 4.51fb−1. Jets are identified using the anti-kt algorithm with two different jet radius parameters, R=0.4 and R=0.6. The dominant uncertainty in these measurements comes from the jet energy scale. Next-to-leading-order QCD calculations corrected to account for non-perturbative effects are compared to the measurements. Good agreement is found between the data and the theoretical predictions based on most of the available sets of parton distribution functions, over the full kinematic range, covering almost seven orders of magnitude in the measured cross-section values.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The huge efforts for the achievement of highly purified biomolecules are growing every day. A great number of efficient techniques, such as chromatography, are already available in laboratory for separation processes. However, membrane-based technologies are the best match to assure simplicity, efficiency and easy scale-up procedures. Herein we report the modification of a commercial microfiltration membrane for plasmid DNA purification by agarose gel impregnation. The membrane was characterized by SEM, ATR-FTIR, EDS, contact angle, and porosity measurements. Additionally, the membrane pore radius was estimated from observed rejections of different proteins and with that information the rejection of a 6050 bp plasmid DNA (pDNA) molecule was estimated for different values of flux using a theoretical model of large flexible molecules in membranes with parallel cylindrical pores, which is applicable to pDNA ultrafiltration in conventional membranes, as recently shown in the literature. The experimental results show that the modified membrane has higher pDNA rejections than the predicted by the model, suggesting that the different type of porous structure that a hydrogel has, may have a positive effect on pDNA rejections as compared to other biomolecules with more rigid structures, making this type of modified membranes potential better candidates to be used for the selective recovery of pDNA in this type of bioprocesses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To evaluate changes in anterior corneal topography and higher-order aberrations (HOA) after 14-days of rigid gas-permeable (RGP) contact lens (CL) wear in keratoconus subjects comparing two different fitting approaches. Methods: Thirty-one keratoconus subjects (50 eyes) without previous history of CL wear were recruited for the study. Subjects were randomly fitted to either an apical-touch or three-pointtouch fitting approach. The lens’ back optic zone radius (BOZR) was 0.4 mm and 0.1 mm flatter than the first definite apical clearance lens, respectively. Differences between the baseline and post-CL wear for steepest, flattest and average corneal power (ACP) readings, central corneal astigmatism (CCA), maximum tangential curvature (KTag), anterior corneal surface asphericity, anterior corneal surface HOA and thinnest corneal thickness measured with Pentacam were compared. Results: A statistically significant flattening was found over time on the flattest and steepest simulated keratometry and ACP in apical-touch group (all p < 0.01). A statistically significant reduction in KTag was found in both groups after contact lens wear (all p < 0.05). Significant reduction was found over time in CCA (p = 0.001) and anterior corneal asphericity in both groups (p < 0.001). Thickness at the thinnest corneal point increased significantly after CL wear (p < 0.0001). Coma-like and total HOA root mean square (RMS) error were significantly reduced following CL wearing in both fitting approaches (all p < 0.05). Conclusion: Short-term rigid gas-permeable CL wear flattens the anterior cornea, increases the thinnest corneal thickness and reduces anterior surface HOA in keratoconus subjects. Apicaltouch was associated with greater corneal flattening in comparison to three-point-touch lens wear.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This Letter presents measurements of correlated production of nearby jets in Pb+Pb collisions at sNN−−−√=2.76 TeV using the ATLAS detector at the Large Hadron Collider. The measurement was performed using 0.14 nb−1 of data recorded in 2011. The production of correlated jet pairs was quantified using the rate, RΔR, of ``neighbouring'' jets that accompany ``test'' jets within a given range of angular distance, ΔR, in the pseudorapidity--azimuthal angle plane. The jets were measured in the ATLAS calorimeter and were reconstructed using the anti-kt algorithm with radius parameters d=0.2, 0.3, and 0.4. RΔR was measured in different Pb+Pb collision centrality bins, characterized by the total transverse energy measured in the forward calorimeters. A centrality dependence of RΔR is observed for all three jet radii with RΔR found to be lower in central collisions than in peripheral collisions. The ratios formed by the RΔR values in different centrality bins and the values in the 40--80 % centrality bin are presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We investigate the strain hardening behavior of various gelatin networks-namely physical gelatin gel, chemically cross-linked gelatin gel, and a hybrid gel made of a combination of the former two-under large shear deformations using the pre-stress, strain ramp, and large amplitude oscillations shear protocols. Further, the internal structures of physical gelatin gels and chemically cross-linked gelatin gels were characterized by small angle neutron scattering (SANS) to enable their internal structures to be correlated with their nonlinear rheology. The Kratky plots of SANS data demonstrate the presence of small cross-linked aggregates within the chemically cross-linked network whereas, in the physical gelatin gels, a relatively homogeneous structure is observed. Through model fitting to the scattering data, we were able to obtain structural parameters, such as the correlation length (ξ), the cross-sectional polymer chain radius (Rc) and the fractal dimension (df) of the gel networks. The fractal dimension df obtained from the SANS data of the physical and chemically cross-linked gels is 1.31 and 1.53, respectively. These values are in excellent agreement with the ones obtained from a generalized nonlinear elastic theory that has been used to fit the stress-strain curves. The chemical cross-linking that generates coils and aggregates hinders the free stretching of the triple helix bundles in the physical gels.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A prevalência de pessoas que referem dor no complexo articular do ombro, com concomitante limitação na capacidade para realizar atividades da vida diária, é elevada. Estes níveis de prevalência sobrecarregam quer os utentes, como a própria sociedade. A evidência científica atual indicia a existência de uma relação entre as alterações da articulação escápulo-torácica e as patologias associadas à articulação gleno-umeral. A capacidade de quantificar, cinemática e cineticamente, as disfunções ao nível das articulações escápulo-torácica e gleno-umeral, é algo de enorme importância, quer para a comunidade biomecânica, como para a clínica. No decorrer dos trabalhos desta tese foi desenvolvido, através do software OpenSim, um modelo tridimensional músculo-esquelético do complexo articular do ombro que inclui a representação do tórax/coluna, clavícula, omoplata, úmero, rádio, cúbito e articulações que permitem os movimentos relativos desses segmentos, assim como, 16 músculos e 4 ligamentos. Com um total de 11 graus de liberdade, incluindo um novo modelo articular escápulo-torácico, os resultados demonstram que este é capaz de reconstruir de forma precisa e rápida os movimentos escápulo-torácicos e glenoumerais, recorrendo para tal, à cinemática inversa, e à dinâmica inversa e direta. Conta ainda com um método de transformação inovador para determinar, com base nas especificidades dos sujeitos, os locais de inserção muscular. As principais motivações subjacentes ao desenvolvimento desta tese foram contribuir para o aprofundar do atual conhecimento sobre as disfunções do complexo articular do ombro e, simultaneamente, proporcionar à comunidade clínica uma ferramenta biomecânica de livre acesso com o intuito de melhor suportar as decisões clínicas e dessa forma concorrer para uma prática mais efetiva.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An algebraic decay rate is derived which bounds the time required for velocities to equilibrate in a spatially homogeneous flow-through model representing the continuum limit of a gas of particles interacting through slightly inelastic collisions. This rate is obtained by reformulating the dynamical problem as the gradient flow of a convex energy on an infinite-dimensional manifold. An abstract theory is developed for gradient flows in length spaces, which shows how degenerate convexity (or even non-convexity) | if uniformly controlled | will quantify contractivity (limit expansivity) of the flow.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Reconstruction of the central aortic pressure wave from the noninvasive recording of the radial pulse with applanation tonometry has become a standard tool in the field of hypertension. It is not presently known whether recording the radial pulse on the dominant or the nondominant side has any effect on such reconstruction. METHOD: We carried out radial applanation tonometry on both forearms in young, healthy, male volunteers, who were either sedentary (n = 11) or high-level tennis players (n = 10). The purpose of including tennis players was to investigate individuals with extreme asymmetry between the dominant and nondominant upper limb. RESULTS: In the sedentary individuals, forearm circumference and handgrip strength were slightly larger on the dominant (mean +/- SD respectively 27.9 +/- 1.5 cm and 53.8 +/- 10 kg) than on nondominant side (27.3 +/- 1.6 cm, P < 0.001 vs. dominant, and 52.1 +/- 11 kg, P = NS). In the tennis players, differences between sides were more conspicuous (forearm circumference: dominant 28.0 +/- 1.7 cm nondominant 26.4 +/- 1.5 cm, P < 0.001; handgrip strength 61.4 +/- 10.8 vs. 53.4 +/- 9.7 kg, P < 0.001). We found that in both sedentary individuals and tennis players, the radial pulse had identical shape on both sides and, consequently, the reconstructed central aortic pressure waveforms, as well as derived indices of central pulsatility, were not dependent on the side where applanation tonometry was carried out. CONCLUSION: Evidence from individuals with maximal asymmetry of dominant vs. nondominant upper limb indicates that laterality of measurement is not a methodological issue for central pulse wave analysis carried out with radial applanation tonometry.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper discusses the use of probabilistic or randomized algorithms for solving combinatorial optimization problems. Our approach employs non-uniform probability distributions to add a biased random behavior to classical heuristics so a large set of alternative good solutions can be quickly obtained in a natural way and without complex conguration processes. This procedure is especially useful in problems where properties such as non-smoothness or non-convexity lead to a highly irregular solution space, for which the traditional optimization methods, both of exact and approximate nature, may fail to reach their full potential. The results obtained are promising enough to suggest that randomizing classical heuristics is a powerful method that can be successfully applied in a variety of cases.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: Residual mitral regurgitation after valve repair worsens patients' clinical outcome. Postimplant adjustable mitral rings potentially address this issue, allowing the reshaping of the annulus on the beating heart under echocardiography control. We developed an original mitral ring allowing valve geometry remodelling after the implantation and designed an animal study to assess device effectiveness in correcting residual mitral regurgitation. METHODS: The device consists of two concentric rings: one internal and flexible, sutured to the mitral annulus and a second external and rigid. A third conic element slides between the two rings, modifying the shape of the flexible ring. This sliding element is remotely activated with a rotating tool. Animal model: in adult swine, under cardio pulmonary bypass and cardiac arrest, we shortened the primary chordae of P2 segment to reproduce Type III regurgitation and implanted the active ring. We used intracardiac ultrasound to assess mitral regurgitation and the efficacy of the active ring to correct it. RESULTS: Severe mitral regurgitation (3+ and 4+) was induced in eight animals, 54 ± 6 kg in weight. Vena contracta width decreased from 0.8 ± 0.2 to 0.1 cm; proximal isovelocity surface area radius decreased from 0.8 ± 0.2 to 0.1 cm and effective regurgitant orifice area decreased from 0.50 ± 0.1 to 0.1 ± 0.1 cm(2). Six animals had a reversal of systolic pulmonary flow that normalized following the activation of the device. All corrections were reversible. CONCLUSIONS: Postimplant adjustable mitral ring corrects severe mitral regurgitation through the reversible modification of the annulus geometry on the beating heart. It addresses the frequent and morbid issue of recurrent mitral valve regurgitation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cette thèse s'intéresse à étudier les propriétés extrémales de certains modèles de risque d'intérêt dans diverses applications de l'assurance, de la finance et des statistiques. Cette thèse se développe selon deux axes principaux, à savoir: Dans la première partie, nous nous concentrons sur deux modèles de risques univariés, c'est-à- dire, un modèle de risque de déflation et un modèle de risque de réassurance. Nous étudions le développement des queues de distribution sous certaines conditions des risques commun¬s. Les principaux résultats sont ainsi illustrés par des exemples typiques et des simulations numériques. Enfin, les résultats sont appliqués aux domaines des assurances, par exemple, les approximations de Value-at-Risk, d'espérance conditionnelle unilatérale etc. La deuxième partie de cette thèse est consacrée à trois modèles à deux variables: Le premier modèle concerne la censure à deux variables des événements extrême. Pour ce modèle, nous proposons tout d'abord une classe d'estimateurs pour les coefficients de dépendance et la probabilité des queues de distributions. Ces estimateurs sont flexibles en raison d'un paramètre de réglage. Leurs distributions asymptotiques sont obtenues sous certaines condi¬tions lentes bivariées de second ordre. Ensuite, nous donnons quelques exemples et présentons une petite étude de simulations de Monte Carlo, suivie par une application sur un ensemble de données réelles d'assurance. L'objectif de notre deuxième modèle de risque à deux variables est l'étude de coefficients de dépendance des queues de distributions obliques et asymétriques à deux variables. Ces distri¬butions obliques et asymétriques sont largement utiles dans les applications statistiques. Elles sont générées principalement par le mélange moyenne-variance de lois normales et le mélange de lois normales asymétriques d'échelles, qui distinguent la structure de dépendance de queue comme indiqué par nos principaux résultats. Le troisième modèle de risque à deux variables concerne le rapprochement des maxima de séries triangulaires elliptiques obliques. Les résultats théoriques sont fondés sur certaines hypothèses concernant le périmètre aléatoire sous-jacent des queues de distributions. -- This thesis aims to investigate the extremal properties of certain risk models of interest in vari¬ous applications from insurance, finance and statistics. This thesis develops along two principal lines, namely: In the first part, we focus on two univariate risk models, i.e., deflated risk and reinsurance risk models. Therein we investigate their tail expansions under certain tail conditions of the common risks. Our main results are illustrated by some typical examples and numerical simu¬lations as well. Finally, the findings are formulated into some applications in insurance fields, for instance, the approximations of Value-at-Risk, conditional tail expectations etc. The second part of this thesis is devoted to the following three bivariate models: The first model is concerned with bivariate censoring of extreme events. For this model, we first propose a class of estimators for both tail dependence coefficient and tail probability. These estimators are flexible due to a tuning parameter and their asymptotic distributions are obtained under some second order bivariate slowly varying conditions of the model. Then, we give some examples and present a small Monte Carlo simulation study followed by an application on a real-data set from insurance. The objective of our second bivariate risk model is the investigation of tail dependence coefficient of bivariate skew slash distributions. Such skew slash distributions are extensively useful in statistical applications and they are generated mainly by normal mean-variance mixture and scaled skew-normal mixture, which distinguish the tail dependence structure as shown by our principle results. The third bivariate risk model is concerned with the approximation of the component-wise maxima of skew elliptical triangular arrays. The theoretical results are based on certain tail assumptions on the underlying random radius.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Vertebral fracture is one of the major osteoporotic fractures which are unfortunately very often undetected. In addition, it is well known that prevalent vertebral fracture increases dramatically the risk of future additional fracture. Instant Vertebral Assessment (IVA) has been introduced in DXA device couple years ago to ease the detection of such fracture when routine DXA are performed. To correctly use such tool, ISCD provided clinical recommendation on when and how to use it. The aim of our study was to evaluate the ISCD guidelines in clinical routine patients and see how often it may change of patient management. Methods: During two months (March and April 2010), a medical questionnaire was systematically given to our clinical routine patient to check the validity of ISCD IVA recommendations in our population. In addition, all women had BMD measurement at AP spine, Femur and 1/3 radius using a Discovery A System (Hologic, Waltham, USA). When appropriate, IVA measurement had been performed on the same DXA system and had been centrally evaluated by two trained Doctors for fracture status according to the semi-quantitative method of Genant. The reading had been performed when possible between L5 and T4. Results: Out of 210 women seen in the consultation, 109 (52%) of them (mean age 68.2 ± 11.5 years) fulfilled the necessary criteria to have an IVA measurement. Out of these 109 women, 43 (incidence 39.4%) had osteoporosis at one of the three skeletal sites and 31 (incidence 28.4%) had at least one vertebral fracture. 14.7% of women had both osteoporosis and at least one vertebral fracture classifying them as "severe osteoporosis" while 46.8% did not have osteoporosis nor vertebral fracture. 24.8% of the women had osteoporosis but no vertebral fracture while 13.8% of women did have osteoporosis and vertebral fracture (clinical osteoporosis). Conclusion: In conclusion, in 52% of our patients, IVA was needed according to ISCD criteria. In half of them the IVA test influenced of patient management either by changing the type of treatment of simply by classifying patient as "clinical osteoporosis". IVA appears to be an important tool in clinical routine but unfortunately is not yet very often used in most of the centers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Vertebral fracture is one of the major osteoporotic fractures which are unfortunately very often undetected. In addition, it is well known that prevalent vertebral fracture increases dramatically the risk of future additional fracture. Instant Vertebral Assessment (IVA) has been introduced in DXA device couple years ago to ease the detection of such fracture when routine DXA are performed. To correctly use such tool, ISCD provided clinical recommendation on when and how to use it. The aim of our study was to evaluate the ISCD guidelines in clinical routine patients and see how often it may change of patient management. During two months (March and April 2010), a medical questionnaire was systematically given to our clinical routine patient to check the validity of ISCD IVA recommendations in our population. In addition, all women had BMD measurement at AP spine, Femur and 1/3 radius using a Discovery A System (Hologic, Waltham, USA). When appropriate, IVA measurement had been performed on the same DXA system and had been centrally evaluated by two trained Doctors for fracture status according to the semi-quantitative method of Genant. The reading had been performed when possible between L5 and T4. Out of 210 women seen in the consultation, 109 (52%) of them (mean age 68.2±11.5 years) fulfilled the necessary criteria to have an IVA measurement. Out of these 109 women, 43 (incidence 39.4%) had osteoporosis at one of the three skeletal sites and 31 (incidence 28.4%) had at least one vertebral fracture. 14.7% of women had both osteoporosis and at least one vertebral fracture classifying them as "severe osteoporosis" while 46.8% did not have osteoporosis not vertebral fracture. 24.8% of the women had osteoporosis but no vertebral fracture while 13.8% of women did have osteoporosis but vertebral fracture (Clinical osteoporosis). In conclusion, in 52% of our patients, IVA was needed according to ISCD criteria. In half of them the IVA test influenced of patient management either my changing the type of treatment of simply by classifying patient as "clinical osteoporosis". IVA appears to be an important tool in clinical routine but unfortunately is not yet very often use in most of the centers.