883 resultados para Radiographic Image Interpretation, Computer-Assisted


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This chapter proposed a personalized X-ray reconstruction-based planning and post-operative treatment evaluation framework called iJoint for advancing modern Total Hip Arthroplasty (THA). Based on a mobile X-ray image calibration phantom and a unique 2D-3D reconstruction technique, iJoint can generate patient-specific models of hip joint by non-rigidly matching statistical shape models to the X-ray radiographs. Such a reconstruction enables a true 3D planning and treatment evaluation of hip arthroplasty from just 2D X-ray radiographs whose acquisition is part of the standard diagnostic and treatment loop. As part of the system, a 3D model-based planning environment provides surgeons with hip arthroplasty related parameters such as implant type, size, position, offset and leg length equalization. With this newly developed system, we are able to provide true 3D solutions for computer assisted planning of THA using only 2D X-ray radiographs, which is not only innovative but also cost-effective.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Patient-specific biomechanical models including local bone mineral density and anisotropy have gained importance for assessing musculoskeletal disorders. However the trabecular bone anisotropy captured by high-resolution imaging is only available at the peripheral skeleton in clinical practice. In this work, we propose a supervised learning approach to predict trabecular bone anisotropy that builds on a novel set of pose invariant feature descriptors. The statistical relationship between trabecular bone anisotropy and feature descriptors were learned from a database of pairs of high resolution QCT and clinical QCT reconstructions. On a set of leave-one-out experiments, we compared the accuracy of the proposed approach to previous ones, and report a mean prediction error of 6% for the tensor norm, 6% for the degree of anisotropy and 19◦ for the principal tensor direction. These findings show the potential of the proposed approach to predict trabecular bone anisotropy from clinically available QCT images.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Residual acetabular dysplasia is seen in combination with femoral pathomorphologies including an aspherical femoral head and valgus neck-shaft angle with high antetorsion. It is unclear how these femoral pathomorphologies affect range of motion (ROM) and impingement zones after periacetabular osteotomy. QUESTIONS/PURPOSES (1) Does periacetabular osteotomy (PAO) restore the typically excessive ROM in dysplastic hips compared with normal hips; (2) how do impingement locations differ in dysplastic hips before and after PAO compared with normal hips; (3) does a concomitant cam-type morphology adversely affect internal rotation; and (4) does a concomitant varus-derotation intertrochanteric osteotomy (IO) affect external rotation? METHODS Between January 1999 and March 2002, we performed 200 PAOs for dysplasia; of those, 27 hips (14%) met prespecified study inclusion criteria, including availability of a pre- and postoperative CT scan that included the hip and the distal femur. In general, we obtained those scans to evaluate the pre- and postoperative acetabular and femoral morphology, the degree of acetabular reorientation, and healing of the osteotomies. Three-dimensional surface models based on CT scans of 27 hips before and after PAO and 19 normal hips were created. Normal hips were obtained from a population of CT-based computer-assisted THAs using the contralateral hip after exclusion of symptomatic hips or hips with abnormal radiographic anatomy. Using validated and computerized methods, we then determined ROM (flexion/extension, internal- [IR]/external rotation [ER], adduction/abduction) and two motion patterns including the anterior (IR in flexion) and posterior (ER in extension) impingement tests. The computed impingement locations were assigned to anatomical locations of the pelvis and the femur. ROM was calculated separately for hips with (n = 13) and without (n = 14) a cam-type morphology and PAOs with (n = 9) and without (n = 18) a concomitant IO. A post hoc power analysis based on the primary research question with an alpha of 0.05 and a beta error of 0.20 revealed a minimal detectable difference of 4.6° of flexion. RESULTS After PAO, flexion, IR, and adduction/abduction did not differ from the nondysplastic control hips with the numbers available (p ranging from 0.061 to 0.867). Extension was decreased (19° ± 15°; range, -18° to 30° versus 28° ± 3°; range, 19°-30°; p = 0.017) and ER in 0° flexion was increased (25° ± 18°; range, -10° to 41° versus 38° ± 7°; range, 17°-41°; p = 0.002). Dysplastic hips had a higher prevalence of extraarticular impingement at the anteroinferior iliac spine compared with normal hips (48% [13 of 27 hips] versus 5% [one of 19 hips], p = 0.002). A PAO increased the prevalence of impingement for the femoral head from 30% (eight of 27 hips) preoperatively to 59% (16 of 27 hips) postoperatively (p = 0.027). IR in flexion was decreased in hips with a cam-type deformity compared with those with a spherical femoral head (p values from 0.002 to 0.047 for 95°-120° of flexion). A concomitant IO led to a normalization of ER in extension (eg, 37° ± 7° [range, 21°-41°] of ER in 0° of flexion in hips with concomitant IO compared with 38° ± 7° [range, 17°-41°] in nondysplastic control hips; p = 0.777). CONCLUSIONS Using computer simulation of hip ROM, we could show that the PAO has the potential to restore the typically excessive ROM in dysplastic hips. However, a PAO can increase the prevalence of secondary intraarticular impingement of the aspherical femoral head and extraarticular impingement of the anteroinferior iliac spines in flexion and internal rotation. A cam-type morphology can result in anterior impingement with restriction of IR. Additionally, a valgus hip with high antetorsion can result in posterior impingement with decreased ER in extension, which can be normalized with a varus derotation IO of the femur. However, indication of an additional IO needs to be weighed against its inherent morbidity and possible complications. The results are based on a limited number of hips with a pre- and postoperative CT scan after PAO. Future prospective studies are needed to verify the current results based on computer simulation and to test their clinical importance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose To this day, the slit lamp remains the first tool used by an ophthalmologist to examine patient eyes. Imaging of the retina poses, however, a variety of problems, namely a shallow depth of focus, reflections from the optical system, a small field of view and non-uniform illumination. For ophthalmologists, the use of slit lamp images for documentation and analysis purposes, however, remains extremely challenging due to large image artifacts. For this reason, we propose an automatic retinal slit lamp video mosaicking, which enlarges the field of view and reduces amount of noise and reflections, thus enhancing image quality. Methods Our method is composed of three parts: (i) viable content segmentation, (ii) global registration and (iii) image blending. Frame content is segmented using gradient boosting with custom pixel-wise features. Speeded-up robust features are used for finding pair-wise translations between frames with robust random sample consensus estimation and graph-based simultaneous localization and mapping for global bundle adjustment. Foreground-aware blending based on feathering merges video frames into comprehensive mosaics. Results Foreground is segmented successfully with an area under the curve of the receiver operating characteristic curve of 0.9557. Mosaicking results and state-of-the-art methods were compared and rated by ophthalmologists showing a strong preference for a large field of view provided by our method. Conclusions The proposed method for global registration of retinal slit lamp images of the retina into comprehensive mosaics improves over state-of-the-art methods and is preferred qualitatively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose In recent years, selective retina laser treatment (SRT), a sub-threshold therapy method, avoids widespread damage to all retinal layers by targeting only a few. While these methods facilitate faster healing, their lack of visual feedback during treatment represents a considerable shortcoming as induced lesions remain invisible with conventional imaging and make clinical use challenging. To overcome this, we present a new strategy to provide location-specific and contact-free automatic feedback of SRT laser applications. Methods We leverage time-resolved optical coherence tomography (OCT) to provide informative feedback to clinicians on outcomes of location-specific treatment. By coupling an OCT system to SRT treatment laser, we visualize structural changes in the retinal layers as they occur via time-resolved depth images. We then propose a novel strategy for automatic assessment of such time-resolved OCT images. To achieve this, we introduce novel image features for this task that when combined with standard machine learning classifiers yield excellent treatment outcome classification capabilities. Results Our approach was evaluated on both ex vivo porcine eyes and human patients in a clinical setting, yielding performances above 95 % accuracy for predicting patient treatment outcomes. In addition, we show that accurate outcomes for human patients can be estimated even when our method is trained using only ex vivo porcine data. Conclusion The proposed technique presents a much needed strategy toward noninvasive, safe, reliable, and repeatable SRT applications. These results are encouraging for the broader use of new treatment options for neovascularization-based retinal pathologies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La segmentación de imágenes puede plantearse como un problema de minimización de una energía discreta. Nos enfrentamos así a una doble cuestión: definir una energía cuyo mínimo proporcione la segmentación buscada y, una vez definida la energía, encontrar un mínimo absoluto de la misma. La primera parte de esta tesis aborda el segundo problema, y la segunda parte, en un contexto más aplicado, el primero. Las técnicas de minimización basadas en cortes de grafos permiten obtener el mínimo de una energía discreta en tiempo polinomial mediante algoritmos de tipo min-cut/max-flow. Sin embargo, estas técnicas solo pueden aplicarse a energías que son representabas por grafos. Un importante reto es estudiar qué energías son representabas así como encontrar un grafo que las represente, lo que equivale a encontrar una función gadget con variables adicionales. En la primera parte de este trabajo se estudian propiedades de las funciones gadgets que permiten acotar superiormente el número de variables adicionales. Además se caracterizan las energías con cuatro variables que son representabas, definiendo gadgets con dos variables adicionales. En la segunda parte, más práctica, se aborda el problema de segmentación de imágenes médicas, base en muchas ocasiones para la diagnosis y el seguimiento de terapias. La segmentación multi-atlas es una potente técnica de segmentación automática de imágenes médicas, con tres aspectos importantes a destacar: el tipo de registro entre los atlas y la imagen objetivo, la selección de atlas y el método de fusión de etiquetas. Este último punto puede formularse como un problema de minimización de una energía. A este respecto introducimos dos nuevas energías representables. La primera, de orden dos, se utiliza en la segmentación en hígado y fondo de imágenes abdominales obtenidas mediante tomografía axial computarizada. La segunda, de orden superior, se utiliza en la segmentación en hipocampos y fondo de imágenes cerebrales obtenidas mediante resonancia magnética. ABSTRACT The image segmentation can be described as the problem of minimizing a discrete energy. We face two problems: first, to define an energy whose minimum provides the desired segmentation and, second, once the energy is defined we must find its global minimum. The first part of this thesis addresses the second problem, and the second part, in a more applied context, the first problem. Minimization techniques based on graph cuts find the minimum of a discrete energy in polynomial time via min-cut/max-flow algorithms. Nevertheless, these techniques can only be applied to graph-representable energies. An important challenge is to study which energies are graph-representable and to construct graphs which represent these energies. This is the same as finding a gadget function with additional variables. In the first part there are studied the properties of gadget functions which allow the number of additional variables to be bounded from above. Moreover, the graph-representable energies with four variables are characterised and gadgets with two additional variables are defined for these. The second part addresses the application of these ideas to medical image segmentation. This is often the first step in computer-assisted diagnosis and monitoring therapy. Multiatlas segmentation is a powerful automatic segmentation technique for medical images, with three important aspects that are highlighted here: the registration between the atlas and the target image, the atlas selection, and the label fusion method. We formulate the label fusion method as a minimization problem and we introduce two new graph-representable energies. The first is a second order energy and it is used for the segmentation of the liver in computed tomography (CT) images. The second energy is a higher order energy and it is used for the segmentation of the hippocampus in magnetic resonance images (MRI).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Póster presentado en SPIE Photonics Europe, Brussels, 16-19 April 2012.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aimed to determine the level of computer practical experience in a sample of Spanish nursing students. Each student was given a Spanish language questionnaire, modified from an original used previously with medical students at the Medical School of North Carolina University (USA) and also at the Education Unit of Hospital General Universitario del Mar (Spain). The 10-item self-report questionnaire probed for information about practical experience with computers. A total of 126 students made up the sample. The majority were female (80.2%; n=101). The results showed that just over half (57.1%, n=72) of the students had used a computer game (three or more times before), and that only one third (37.3%, n=47) had the experience of using a word processing package. Moreover, other applications and IT-based facilities (e.g. statistical packages, e-mail, databases, CD-ROM searches, programming languages and computer-assisted learning) had never been used by the majority of students. The student nurses' practical experience was less than that reported for medical students in previous studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Includes bibliographical references.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

"February, 1969"

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study presents a detailed contrastive description of the textual functioning of connectives in English and Arabic. Particular emphasis is placed on the organisational force of connectives and their role in sustaining cohesion. The description is intended as a contribution for a better understanding of the variations in the dominant tendencies for text organisation in each language. The findings are expected to be utilised for pedagogical purposes, particularly in improving EFL teaching of writing at the undergraduate level. The study is based on an empirical investigation of the phenomenon of connectivity and, for optimal efficiency, employs computer-aided procedures, particularly those adopted in corpus linguistics, for investigatory purposes. One important methodological requirement is the establishment of two comparable and statistically adequate corpora, also the design of software and the use of existing packages and to achieve the basic analysis. Each corpus comprises ca 250,000 words of newspaper material sampled in accordance to a specific set of criteria and assembled in machine readable form prior to the computer-assisted analysis. A suite of programmes have been written in SPITBOL to accomplish a variety of analytical tasks, and in particular to perform a battery of measurements intended to quantify the textual functioning of connectives in each corpus. Concordances and some word lists are produced by using OCP. Results of these researches confirm the existence of fundamental differences in text organisation in Arabic in comparison to English. This manifests itself in the way textual operations of grouping and sequencing are performed and in the intensity of the textual role of connectives in imposing linearity and continuity and in maintaining overall stability. Furthermore, computation of connective functionality and range of operationality has identified fundamental differences in the way favourable choices for text organisation are made and implemented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The research was instigated by the Civil Aviation Authority (CAA) to examine the implications for air traffic controllers' (ATCO) job satisfaction of the possible introduction of systems incorporating computer-assisted decision making. Additional research objectives were to assess the possible costs of reductions in ATCO job satisfaction, and to recommend appropriate task allocation between ATCOs and computer for future systems design (Chapter 1). Following a review of the literature (Chapter 2) it is argued that existing approaches to systems and job design do not allow for a sufficiently early consideration of employee needs and satisfactions in the design of complex systems. The present research develops a methodology for assessing affective reactions to an existing system as a basis for making reommendations for future systems design (Chapter 3). The method required analysis of job content using two techniques: (a) task analysis (Chapter 4.1) and (b) the Job Diagnostic Survey (JDS). ATCOs' affective reactions to the several operational positions on which they work were investigated at three levels of detail: (a) Reactions to positions, obtained by ranking techniques (Chapter 4.2); (b) Reactions to job characteristics, obtained by use of JDS (Chapter 4.3); and (c) Reactions to tasks, obtained by use of Repertory Grid technique (Chapter 4.4). The conclusion is drawn that ATCOs' motivation and satisfaction is greatly dependent on the presence of challenge, often through tasks requiring the use of decision making and other cognitive skills. Results suggest that the introduction of systems incorporating computer-assisted decision making might result in financial penalties for the CAA and significant reductions in job satisfaction for ATCOs. General recommendations are made for allocation of tasks in future systems design (Chapter 5).