996 resultados para RMS


Relevância:

10.00% 10.00%

Publicador:

Resumo:

After the development of power electronics converters, the number of transformers subjected to non-sinusoidal stresses (including DC) has increased in applications such as HVDC links and traction (electric train power cars). The effects of non-sinusoidal voltages on transformer insulation have been investigated by many researchers, but still now, there are some issues that must be understood. Some of those issues are tackled in this Thesis, studying PD phenomena behavior in Kraft paper, pressboard and mineral oil at different voltage conditions like AC, DC, AC+DC, notched AC and square waveforms. From the point of view of converter transformers, it was found that the combined effect of AC and DC voltages produces higher stresses in the pressboard that those that are present under pure DC voltages. The electrical conductivity of the dielectric systems in DC and AC+DC conditions has demonstrated to be a critical parameter, so, its measurement and analysis was also taken into account during all the experiments. Regarding notched voltages, the RMS reduction caused by notches (depending on firing and overlap angles) seems to increase the PDIV. However, the experimental results show that once PD activity has incepted, the notches increase PD repetition rate and magnitude, producing a higher degradation rate of paper. On the other hand, the reduction of mineral oil stocks, their relatively low flash point as well as environmental issues, are factors that are pushing towards the use of esters as transformer insulating fluids. This PhD Thesis also covers the study of two different esters with the scope to validate their use in traction transformers. Mineral oil was used as benchmark. The complete set of dielectric tests performed in the three fluids, show that esters behave better than mineral oil in practically all the investigated conditions, so, their application in traction transformers is possible and encouraged.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Progetto di tesi sviluppato in collaborazione con l'azienda GIMA TT S.r.l. di Ozzano dell'Emilia (gruppo IMA), focalizzato su un gruppo di una macchina automatica etichettatrice da essa prodotta, con l'obiettivo di ottenerne un incremento di produttività del 50%. Per il raggiungimento dell'obiettivo, ci si è concentrati sulla ricerca di soluzioni tecniche per la modifica e l'ottimizzazione del gruppo di applicazione del sigillo di stato ai pacchetti, al fine di ridurre sensibilmente la coppia massima e RMS rilevate sul motore.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recent advances in the fast growing area of therapeutic/diagnostic proteins and antibodies - novel and highly specific drugs - as well as the progress in the field of functional proteomics regarding the correlation between the aggregation of damaged proteins and (immuno) senescence or aging-related pathologies, underline the need for adequate analytical methods for the detection, separation, characterization and quantification of protein aggregates, regardless of the their origin or formation mechanism. Hollow fiber flow field-flow fractionation (HF5), the miniaturized version of FlowFFF and integral part of the Eclipse DUALTEC FFF separation system, was the focus of this research; this flow-based separation technique proved to be uniquely suited for the hydrodynamic size-based separation of proteins and protein aggregates in a very broad size and molecular weight (MW) range, often present at trace levels. HF5 has shown to be (a) highly selective in terms of protein diffusion coefficients, (b) versatile in terms of bio-compatible carrier solution choice, (c) able to preserve the biophysical properties/molecular conformation of the proteins/protein aggregates and (d) able to discriminate between different types of protein aggregates. Thanks to the miniaturization advantages and the online coupling with highly sensitive detection techniques (UV/Vis, intrinsic fluorescence and multi-angle light scattering), HF5 had very low detection/quantification limits for protein aggregates. Compared to size-exclusion chromatography (SEC), HF5 demonstrated superior selectivity and potential as orthogonal analytical method in the extended characterization assays, often required by therapeutic protein formulations. In addition, the developed HF5 methods have proven to be rapid, highly selective, sensitive and repeatable. HF5 was ideally suitable as first dimension of separation of aging-related protein aggregates from whole cell lysates (proteome pre-fractionation method) and, by HF5-(UV)-MALS online coupling, important biophysical information on the fractionated proteins and protein aggregates was gathered: size (rms radius and hydrodynamic radius), absolute MW and conformation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis presents a possible method to calculate sea level variation using geodetic-quality Global Navigate Satellite System (GNSS) receivers. Three antennas are used: two small antennas and a choke ring one, analyzing only Global Positioning System signals. The main goal of the thesis is to test a modified configuration for antenna set up. In particular, measurements obtained tilting one antenna to face the horizon are compared to measurements obtained from antennas looking upward. The location of the experiment is a coastal environment nearby the Onsala Space Observatory in Sweden. Sea level variations are obtained using periodogram analysis of the SNR signal and compared to synthetic gauge generated from two independent tide gauges. The choke ring antenna provides poor result, with an RMS around 6 cm and a correlation coefficients of 0.89. The smaller antennas provide correlation coefficients around 0.93. The antenna pointing upward present an RMS of 4.3 cm and the one pointing the horizon an RMS of 6.7 cm. Notable variation in the statistical parameters is found when modifying the length of the interval analyzed. In particular, doubts are risen on the reliability of certain scattered data. No relation is found between the accuracy of the method and weather conditions. Possible methods to enhance the available data are investigated, and correlation coefficient above 0.97 can be obtained with small antennas when sacrificing data points. Hence, the results provide evidence of the suitability of SNR signal analysis for sea level variation in coastal environment even in the case of adverse weather conditions. In particular, tilted configurations provides comparable result with upward looking geodetic antennas. A SNR signal simulator is also tested to investigate its performance and usability. Various configuration are analyzed in combination with the periodogram procedure used to calculate the height of reflectors. Consistency between the data calculated and those received is found, and the overall accuracy of the height calculation program is found to be around 5 mm for input height below 5 m. The procedure is thus found to be suitable to analyze the data provided by the GNSS antennas at Onsala.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Am Mainzer Mikrotron MAMI wurde ein neuartiges Interferometer entwickelt und getestet, mit dem magneto-optische Effekte an dünnen, freitragenden Folien von 3d-Übergangsmetallen wie Eisen, Kobalt oder Nickel an den L_{2,3}-Absorptionskanten (im Spektralbereich der weichen Röntgenstrahlung) gemessen werden können. Es handelt sich um eine Weiterentwicklung eines an MAMI erprobten Interferometers, das im wesentlichen aus einer kollinearen Anordnung zweier identischer Undulatoren, zwischen die die dünne Probefolie eingebracht wird, und einem Gitterspektrometer besteht. Aus den als Funktion des Abstands der Undulatoren beobachtbaren Intensitätsoszillation lassen sich das Dekrement des Realteils δ und der Absorptionskoeffizient β des komplexen Brechungsindex bestimmen.rnIm Rahmen der vorliegenden Arbeit wurde die Apparatur derart weiterentwickelt, dass auch die magnetisch zirkulare Doppelbrechung Δδ und der magnetisch zirkulare Dichroismus Δβ an den L_{2,3}-Absorptionskanten von Übergangsmetallen gemessen werden können. Der zweite Undulator wurde um die Elektronenstrahlachse um den Winkel Ψ = ±107° drehbar gemacht. Damit dient er auch als Analysator der aus der Folie austretenden elliptisch polarisierten weichen Röntgenstrahlung, für die - wie bei der Faraday-Rotation - die Polarisationsebene gedreht ist. Weiterhin kann die Spaltbreite der 10-poligen Hybrid-Undulatoren mit einer Periodenlänge von 12 mm und damit der Undulatorparameter über eine Antriebsmechanik kontinuierlich variiert werden, wodurch eine optimale Anpassung der Amplituden der Undulatorstrahlung aus den beiden Undulatoren möglich wird. Der maximale Undulatorparameter beträgt K = 1.1. Auch das Spektrometer, das auf einem selbstfokussierenden Gitter mit variierter Liniendichte (im Mittel 1400 Linien / mm) basiert, wurde weiterentwickelt. Als Detektor kommt jetzt eine fensterlose CCD mit 1024 x 1024 Pixeln und einer Pixelgröße von 13 μm x 13 μm zum Einsatz, die im Bildmodus betrieben wird, was die gleichzeitige Messung eines Energieintervalls von ca. 50 eV ermöglicht. Die totale Linienbreite wurde bei einer vertikalen Strahlfleckausdehnung von σ_y = 70 μm (rms) am Neon 1s-3p Übergang bei (867.18 ±0.02) eV zu Δħω = (0.218 ±0.002) eV (FWHM) gemessen. Das hohe Auflösungsvermögen von 4000 und die Möglichkeit der Eichung gegen den 1s-3p Übergang von Neon wurden ausgenutzt, um die Energie der Maxima an den Absorptionskanten von Nickel (weiße Linien) neu zu bestimmen. Die Ergebnisse E_{L_2}=(869.65_{-0.16}^{+0.27}) eV und E_{L_3}=(852.37_{-0.11}^{+0.16}) eV stellen eine Verbesserung früherer Messungen dar, die große Streuungen aufwiesen.rnAus systematischen Messungen als Funktion des Abstandes der Undulatoren und des Drehwinkels Ψ wurden die magnetisch zirkulare Doppelbrechung Δδ im Energiebereich 834 eV ≤ ħω ≤ 885 eV an einer freitragenden, bis zur Sättigung magnetisierten Nickelfolie der Dicke von (96.4 ±2.7) nm gemessen. Sowohl das Auflösungsvermögen als auch die Genauigkeit der Messungen für Δδ übersteigen bekannte Literaturangaben signifikant, so dass eine bisher nicht bekannte Feinstruktur gefunden werden konnte. Außerdem wurde der Betrag des magnetisch zirkularen Dichroismus |Δβ| im Bereich des Maximums an der L_3-Absorptionskante mit hoher Genauigkeit gemessen.rn

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Die Invarianz physikalischer Gesetze unter Lorentztransformationen ist eines der fundamentalen Postulate der modernen Physik und alle Theorien der grundlegenden Wechselwirkungen sind in kovarianter Form formuliert. Obwohl die Spezielle Relativitätstheorie (SRT) in einer Vielzahl von Experimenten mit hoher Genauigkeit überprüft und bestätigt wurde, sind aufgrund der weitreichenden Bedeutung dieses Postulats weitere verbesserte Tests von grundsätzlichem Interesse. Darüber hinaus weisen moderne Ansätze zur Vereinheitlichung der Gravitation mit den anderen Wechselwirkungen auf eine mögliche Verletzung der Lorentzinvarianz hin. In diesem Zusammenhang spielen Ives-Stilwell Experimente zum Test der Zeitdilatation in der SRT eine bedeutende Rolle. Dabei wird die hochauflösende Laserspektroskopie eingesetzt, um die Gültigkeit der relativistischen Dopplerformel – und damit des Zeitdilatationsfaktors γ – an relativistischen Teilchenstrahlen zu untersuchen. Im Rahmen dieser Arbeit wurde ein Ives-Stilwell Experiment an 7Li+-Ionen, die bei einer Geschwindigkeit von 34 % der Lichtgeschwindigkeit im Experimentierspeicherring (ESR) des GSI Helmholtzzentrums für Schwerionenforschung gespeichert waren, durchgeführt. Unter Verwendung des 1s2s3S1→ 1s2p3P2-Übergangs wurde sowohl Λ-Spektroskopie als auch Sättigungsspektroskopie betrieben. Durch die computergestützte Analyse des Fluoreszenznachweises und unter Verwendung optimierter Kantenfilter für den Nachweis konnte das Signal zu Rauschverhältnis entscheidend verbessert und unter Einsatz eines zusätzlichen Pumplasers erstmals ein Sättigungssignal beobachtet werden. Die Frequenzstabilität der beiden verwendeten Lasersysteme wurde mit Hilfe eines Frequenzkamms spezifiziert, um eine möglichst hohe Genauigkeit zu erreichen. Die aus den Strahlzeiten gewonnen Daten wurden im Rahmen der Robertson-Mansouri-Sexl-Testtheorie (RMS) und der Standard Model Extension (SME) interpretiert und entsprechende Obergrenzen für die relevanten Testparameter der jeweiligen Theorie bestimmt. Die Obergrenze für den Testparameter α der RMS-Theorie konnte gegenüber den früheren Messungen bei 6,4 % der Lichtgeschwindigkeit am Testspeicherring (TSR) des Max-Planck-Instituts für Kernphysik in Heidelberg um einen Faktor 4 verbessert werden.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Radial velocities measured from near-infrared (NIR) spectra are a potential tool to search for extrasolar planets around cool stars. High resolution infrared spectrographs now available reach the high precision of visible instruments, with a constant improvement over time. GIANO is an infrared echelle spectrograph and it is a powerful tool to provide high resolution spectra for accurate radial velocity measurements of exo-planets and for chemical and dynamical studies of stellar or extragalactic objects. No other IR instruments have the GIANO's capability to cover the entire NIR wavelength range. In this work we develop an ensemble of IDL procedures to measure high precision radial velocities on a few GIANO spectra acquired during the commissioning run, using the telluric lines as wevelength reference. In Section 1.1 various exoplanet search methods are described. They exploit different properties of the planetary system. In Section 1.2 we describe the exoplanet population discovered trough the different methods. In Section 1.3 we explain motivations for NIR radial velocities and the challenges related the main issue that has limited the pursuit of high-precision NIR radial velocity, that is, the lack of a suitable calibration method. We briefly describe calibration methods in the visible and the solutions for IR calibration, for instance, the use of telluric lines. The latter has advantages and problems, described in detail. In this work we use telluric lines as wavelength reference. In Section 1.4 the Cross Correlation Function (CCF) method is described. This method is widely used to measure the radial velocities.In Section 1.5 we describe GIANO and its main science targets. In Chapter 2 observational data obtained with GIANO spectrograph are presented and the choice criteria are reported. In Chapter 3 we describe the detail of the analysis and examine in depth the flow chart reported in Section 3.1. In Chapter 4 we give the radial velocities measured with our IDL procedure for all available targets. We obtain an rms scatter in radial velocities of about 7 m/s. Finally, we conclude that GIANO can be used to measure radial velocities of late type stars with an accuracy close to or better than 10 m/s, using telluric lines as wevelength reference. In 2014 September GIANO is being operative at TNG for Science Verification and more observational data will allow to further refine this analysis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Für eine erfolgreiche Behandlung bösartiger Tumore ist eine frühzeitige Diagnose, aber auch eine effektive und effiziente Therapie essentiell. In diesem Zusammenhang sind Nanomaterialien in den Fokus der Arzneimittelentwicklung gerückt, welche für Diagnostik und Therapie genutzt werden könnten.rnSystematische Studien zur Radiometallmarkierung von Nanopartikeln und deren Stabilität in vitro im Zusammenhang mit der Struktur des Linkers und dem Anteil an Chelator wurden anhand verschiedener HPMA-DOTA-Konjugate durchgeführt. Es konnte gezeigt werden, dass die Linkerstruktur und der Belegungsgrad sowohl die Markierung als auch die in vitro -Stabilität von radiometallmarkierten HPMA-rnDOTA-Konjugaten beeinflussen.rnFür die Markierung selbst stehen mehrere Generator-produzierte metallische Positronenemitter zur Verfügung. Infolge der gesetzlichen Bestimmungen muss das Eluat der Generatoren bestimmte Spezifikationen (Elutionsausbeute, Durchbruch des Mutternuklids, Gehalt an Fremdionen, pH-Wert etc.) erfüllen, um für die Darstellung von Radiopharmaka verwendet werden zu können.rnFür das bereits etablierte PET-Nuklid 68Ga konnte eine Ethanol-basierte Aufreinigung entwickelt werden, welche hohe Elutions- und Markierungsausbeuten sowie Radionuklidreinheit garantiert und damit einen wichtigen Schritt für die Entwicklung von Kit-Formulierungen repräsentiert. Ausserdem konnten zwei Methoden zur Qualitätskontrolle entwickelt werden, welche es ermöglichen die Radionuklidreinheit des initialen 68Ga-Eluats, aber auch des finalen 68Ga-Radiopharmakons innerhalb einer Stunde ohne γ–Spektroskopie zu bestimmen.rnWährend mit 68Ga die Pharmakokinetik markierter Derivate für einen Zeitraum von bis 3 Stunden zugänglich ist, deckt das Generator-produzierte 44Sc eine Periode von bis zu einem Tag ab. Damit lässt sich die Pharmakokinetik markierter polymerer Drug Carrier-Systeme – von der frühen Ausscheidungsphase bis hin zu organspezifischen Akkumulationen durch passives und aktives Targeting – gut beschreiben.rnFür 44Sc konnte anhand der Modellverbindung DOTATOC gezeigt werden, dass das aufgereinigte Generatoreluat für die Markierung mit hohen radiochemischen Ausbeuten geeignet ist und etablierte Markierungsmethoden übertragbar sind. In weiterführenden Studien zur molekularen Bildgebung könnte das Potential dieses PET-Nuklids für die Langzeitbildgebung gezeigt werden.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Negli ultimi anni va sempre più affermandosi l’idea che nei test a fatica utilizzati in ambito industriale per testare la resistenza di numerosi prodotti, riprodurre profili vibratori con distribuzioni gaussiane non sia sufficientemente realistico. Nell’indagine sperimentale riportata in questo trattato vengono confrontati gli effetti generati da sollecitazioni leptocurtiche ottenute da misurazioni reali, con profili vibratori gaussiani a parità di RMS e forma della PSD (Power Spectral Density) verificando la validità della “Papoulis rule”. A partire da questi profili vibratori si è effettuata una progettazione ad hoc dalla quale sono stati ricavati dei provini piatti in lega di alluminio a cui è collegata una massa ausiliaria. Quest’ultimi montati a sbalzo su uno shaker elettrodinamico, sono caratterizzati da una variazione di sezione che localizza la sezione critica in prossimità dell’incastro. I provini sono stati inoltre caratterizzati attraverso prove a trazione e test accelerati a fatica, ricavandone la caratteristica a trazione del materiale ed il diagramma di Wohler. In seguito alla descrizione di tali prove viene riportata un’analisi dei provini sollecitati da due profili vibratori, uno gaussiano e uno ad elevato valore di kurtosis, monitorando tramite l’impiego di accelerometri i valori dell’eccitazione e la risposta. Vengono inoltre verificati i valori delle deformazioni dovute alle sollecitazioni imposte collocando due estensimetri in corrispondenza della sezione critica di due provini (uno per ogni tipologia di input).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

L’obiettivo del lavoro esposto nella seguente relazione di tesi ha riguardato lo studio e la simulazione di esperimenti di radar bistatico per missioni di esplorazione planeteria. In particolare, il lavoro si è concentrato sull’uso ed il miglioramento di un simulatore software già realizzato da un consorzio di aziende ed enti di ricerca nell’ambito di uno studio dell’Agenzia Spaziale Europea (European Space Agency – ESA) finanziato nel 2008, e svolto fra il 2009 e 2010. L’azienda spagnola GMV ha coordinato lo studio, al quale presero parte anche gruppi di ricerca dell’Università di Roma “Sapienza” e dell’Università di Bologna. Il lavoro svolto si è incentrato sulla determinazione della causa di alcune inconsistenze negli output relativi alla parte del simulatore, progettato in ambiente MATLAB, finalizzato alla stima delle caratteristiche della superficie di Titano, in particolare la costante dielettrica e la rugosità media della superficie, mediante un esperimento con radar bistatico in modalità downlink eseguito dalla sonda Cassini-Huygens in orbita intorno al Titano stesso. Esperimenti con radar bistatico per lo studio di corpi celesti sono presenti nella storia dell’esplorazione spaziale fin dagli anni ’60, anche se ogni volta le apparecchiature utilizzate e le fasi di missione, durante le quali questi esperimenti erano effettuati, non sono state mai appositamente progettate per lo scopo. Da qui la necessità di progettare un simulatore per studiare varie possibili modalità di esperimenti con radar bistatico in diversi tipi di missione. In una prima fase di approccio al simulatore, il lavoro si è incentrato sullo studio della documentazione in allegato al codice così da avere un’idea generale della sua struttura e funzionamento. È seguita poi una fase di studio dettagliato, determinando lo scopo di ogni linea di codice utilizzata, nonché la verifica in letteratura delle formule e dei modelli utilizzati per la determinazione di diversi parametri. In una seconda fase il lavoro ha previsto l’intervento diretto sul codice con una serie di indagini volte a determinarne la coerenza e l’attendibilità dei risultati. Ogni indagine ha previsto una diminuzione delle ipotesi semplificative imposte al modello utilizzato in modo tale da identificare con maggiore sicurezza la parte del codice responsabile dell’inesattezza degli output del simulatore. I risultati ottenuti hanno permesso la correzione di alcune parti del codice e la determinazione della principale fonte di errore sugli output, circoscrivendo l’oggetto di studio per future indagini mirate.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Lung recruitment maneuvers (RMs), used to reopen atelectatic lung units and to improve oxygenation during mechanical ventilation, may result in hemodynamic impairment. We hypothesize that pulmonary arterial hypertension aggravates the consequences of RMs in the splanchnic circulation. Twelve anesthetized pigs underwent laparotomy and prolonged postoperative ventilation. Systemic, regional, and organ blood flows were monitored. After 6 h (= baseline), a recruitment maneuver was performed with sustained inflation of the lungs. Thereafter, the pigs were randomly assigned to group C (control, n = 6) or group E with endotoxin-induced pulmonary arterial hypertension (n = 6). Endotoxemia resulted in a normotensive and hyperdynamic state and a deterioration of the oxygenation index by 33%. The RM was then repeated in both groups. Pulmonary artery pressure increased during lipopolysaccharide infusion from 17 ± 2 mmHg (mean ± SD) to 31 ± 10 mmHg and remained unchanged in controls (P < 0.05). During endotoxemia, RM decreased aortic pulse pressure from 37 ± 14 mmHg to 27 ± 13 mmHg (mean ± SD, P = 0.024). The blood flows of the renal artery, hepatic artery, celiac trunk, superior mesenteric artery, and portal vein decreased to 71% ± 21%, 69% ± 20%, 76% ± 16%, 79% ± 18%, and 81% ± 12%, respectively, of baseline flows before RM (P < 0.05 all). Organ perfusion of kidney cortex, kidney medulla, liver, and jejunal mucosa in group E decreased to 65% ± 19%, 77% ± 13%, 66% ± 26%, and 71% ± 12%, respectively, of baseline flows (P < 0.05 all). The corresponding recovery to at least 90% of baseline regional blood flow and organ perfusion lasted 1 to 5 min. Importantly, the decreases in regional blood flows and organ perfusion and the time to recovery of these flows did not differ from the controls. In conclusion, lipopolysaccharide-induced pulmonary arterial hypertension does not aggravate the RM-induced significant but short-lasting decreases in systemic, regional, and organ blood flows.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose Accurate three-dimensional (3D) models of lumbar vertebrae can enable image-based 3D kinematic analysis. The common approach to derive 3D models is by direct segmentation of CT or MRI datasets. However, these have the disadvantages that they are expensive, timeconsuming and/or induce high-radiation doses to the patient. In this study, we present a technique to automatically reconstruct a scaled 3D lumbar vertebral model from a single two-dimensional (2D) lateral fluoroscopic image. Methods Our technique is based on a hybrid 2D/3D deformable registration strategy combining a landmark-to-ray registration with a statistical shape model-based 2D/3D reconstruction scheme. Fig. 1 shows different stages of the reconstruction process. Four cadaveric lumbar spine segments (total twelve lumbar vertebrae) were used to validate the technique. To evaluate the reconstruction accuracy, the surface models reconstructed from the lateral fluoroscopic images were compared to the associated ground truth data derived from a 3D CT-scan reconstruction technique. For each case, a surface-based matching was first used to recover the scale and the rigid transformation between the reconstructed surface model Results Our technique could successfully reconstruct 3D surface models of all twelve vertebrae. After recovering the scale and the rigid transformation between the reconstructed surface models and the ground truth models, the average error of the 2D/3D surface model reconstruction over the twelve lumbar vertebrae was found to be 1.0 mm. The errors of reconstructing surface models of all twelve vertebrae are shown in Fig. 2. It was found that the mean errors of the reconstructed surface models in comparison to their associated ground truths after iterative scaled rigid registrations ranged from 0.7 mm to 1.3 mm and the rootmean squared (RMS) errors ranged from 1.0 mm to 1.7 mm. The average mean reconstruction error was found to be 1.0 mm. Conclusion An accurate, scaled 3D reconstruction of the lumbar vertebra can be obtained from a single lateral fluoroscopic image using a statistical shape model based 2D/3D reconstruction technique. Future work will focus on applying the reconstructed model for 3D kinematic analysis of lumbar vertebrae, an extension of our previously-reported imagebased kinematic analysis. The developed method also has potential applications in surgical planning and navigation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The prevalence of overweight and obesity in children is increasing. A growing number of children are thus suffering from complications of obesity. Contributing factors can be found on an individual level as well as in the familial and social environment of affected children. Currently there is no single evidence-based treatment strategy available. Studies from family practice are scarce. Multimodal, long-term, easily accessible treatments as offered in family practice are promising and likely to be cost-effective. The sustainability of these changes in behavior still needs to be demonstrated.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Radiological investigations using gadolinium or intravenous iodinated contrast products are used cautiously in patients suffering from chronic kidney disease because of their risk of acute kidney injury and systemic nephrogenic fibrosis. In this article, we review several radiological alternatives that can be useful to obtain renal anatomical and/or functional information in this patient population. The basic principles, indications, and advantages and limitations of Doppler ultrasound with measurement of the resistance index, contrast-enhanced ultrasound, and a technique called BOLD-MRI (blood-oxygenation level dependent-MRI) are discussed.