992 resultados para Quantitative oogram technique


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quantitative method of viral pollution determination for large volume of water using ferric hydroxide gel impregnated on the surface of glassfibre cartridge filter. The use of ferric hydroxide gel, impregnated on the surface of glassfibre cartridge filter enable us to recover 62.5% of virus (Poliomylitis type I, Lsc strain) exsogeneously added to 400 liters of tap-water. The virus concentrator system consists of four cartridge filters, in which the three first one are clarifiers, where the contaminants are removed physically, without significant virus loss at this stage. The last cartridge filter is impregnated with ferric hydroxide gel, where the virus is adsorbed. After the required volume of water has been processed, the last filter is removed from the system and the viruses are recovered from the gel, using 1 liter of glycine/NaOH buffer, at pH 11. Immediately the eluate is clarified through series of cellulose acetate membranes mounted in a 142mm Millipore filter. For the second step of virus concentration, HC1 1N is added slowly to the eluate to achieve pH 3.5-4. MgC1, is added to give a final concentration of 0.05M and the viruses are readsorbed on a 0.45 , porosity (HA) cellulose acetate membrane, mounted in a 90 mm Millipore filter. The viruses are recovered using the same eluent plus 10% of fetal calf serum, to a final volume of 3 ml. In this way, it was possible to concentrate virus from 400 liters of tap-water, into 1 liter in the first stage of virus concentration and just to 3 ml of final volume in a second step. The efficiency, simplicity and low operational cost, provded by the method, make it feasible to study viral pollution of recreational and tap-water sources.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La douleur est fréquente en milieu de soins intensifs et sa gestion est l'une des missions des infirmières. Son évaluation est une prémisse indispensable à son soulagement. Cependant lorsque le patient est incapable de signaler sa douleur, les infirmières doivent se baser sur des signes externes pour l'évaluer. Les guides de bonne pratique recommandent chez les personnes non communicantes l'usage d'un instrument validé pour la population donnée et basé sur l'observation des comportements. A l'heure actuelle, les instruments d'évaluation de la douleur disponibles ne sont que partiellement adaptés aux personnes cérébrolésées dans la mesure où ces personnes présentent des comportements qui leur sont spécifiques. C'est pourquoi, cette étude vise à identifier, décrire et valider des indicateurs, et des descripteurs, de la douleur chez les personnes cérébrolésées. Un devis d'étude mixte multiphase avec une dominante quantitative a été choisi pour cette étude. Une première phase consistait à identifier des indicateurs et des descripteurs de la douleur chez les personnes cérébrolésées non communicantes aux soins intensifs en combinant trois sources de données : une revue intégrative des écrits, une démarche consultative utilisant la technique du groupe nominal auprès de 18 cliniciens expérimentés (6 médecins et 12 infirmières) et les résultats d'une étude pilote observationnelle réalisée auprès de 10 traumatisés crâniens. Les résultats ont permis d'identifier 6 indicateurs et 47 descripteurs comportementaux, vocaux et physiologiques susceptibles d'être inclus dans un instrument d'évaluation de la douleur destiné aux personnes cérébrolésées non- communicantes aux soins intensifs. Une deuxième phase séquentielle vérifiait les propriétés psychométriques des indicateurs et des descripteurs préalablement identifiés. La validation de contenu a été testée auprès de 10 experts cliniques et 4 experts scientifiques à l'aide d'un questionnaire structuré qui cherchait à évaluer la pertinence et la clarté/compréhensibilité de chaque descripteur. Cette démarche a permis de sélectionner 33 des 47 descripteurs et valider 6 indicateurs. Dans un deuxième temps, les propriétés psychométriques de ces indicateurs et descripteurs ont été étudiés au repos, lors de stimulation non nociceptive et lors d'une stimulation nociceptive (la latéralisation du patient) auprès de 116 personnes cérébrolésées aux soins intensifs hospitalisées dans deux centres hospitaliers universitaires. Les résultats montrent d'importantes variations dans les descripteurs observés lors de stimulation nociceptive probablement dues à l'hétérogénéité des patients au niveau de leur état de conscience. Dix descripteurs ont été éliminés, car leur fréquence lors de la stimulation nociceptive était inférieure à 5% ou leur fiabilité insuffisante. Les descripteurs physiologiques ont tous été supprimés en raison de leur faible variabilité et d'une fiabilité inter juge problématique. Les résultats montrent que la validité concomitante, c'est-à-dire la corrélation entre l'auto- évaluation du patient et les mesures réalisées avec les descripteurs, est satisfaisante lors de stimulation nociceptive {rs=0,527, p=0,003, n=30). Par contre la validité convergente, qui vérifiait l'association entre l'évaluation de la douleur par l'infirmière en charge du patient et les mesures réalisés avec les descripteurs, ainsi que la validité divergente, qui vérifiait si les indicateurs discriminent entre la stimulation nociceptive et le repos, mettent en évidence des résultats variables en fonction de l'état de conscience des patients. Ces résultats soulignent la nécessité d'étudier les descripteurs de la douleur chez des patients cérébrolésés en fonction du niveau de conscience et de considérer l'hétérogénéité de cette population dans la conception d'un instrument d'évaluation de la douleur pour les personnes cérébrolésées non communicantes aux soins intensifs. - Pain is frequent in the intensive care unit (ICU) and its management is a major issue for nurses. The assessment of pain is a prerequisite for appropriate pain management. However, pain assessment is difficult when patients are unable to communicate about their experience and nurses have to base their evaluation on external signs. Clinical practice guidelines highlight the need to use behavioral scales that have been validated for nonverbal patients. Current behavioral pain tools for ICU patients unable to communicate may not be appropriate for nonverbal brain-injured ICU patients, as they demonstrate specific responses to pain. This study aimed to identify, describe and validate pain indicators and descriptors in brain-injured ICU patients. A mixed multiphase method design with a quantitative dominant was chosen for this study. The first phase aimed to identify indicators and descriptors of pain for nonverbal brain- injured ICU patients using data from three sources: an integrative literature review, a consultation using the nominal group technique with 18 experienced clinicians (12 nurses and 6 physicians) and the results of an observational pilot study with 10 traumatic brain injured patients. The results of this first phase identified 6 indicators and 47 behavioral, vocal and physiological descriptors of pain that could be included in a pain assessment tool for this population. The sequential phase two tested the psychometric properties of the list of previously identified indicators and descriptors. Content validity was tested with 10 clinical and 4 scientific experts for pertinence and comprehensibility using a structured questionnaire. This process resulted in 33 descriptors to be selected out of 47 previously identified, and six validated indicators. Then, the psychometric properties of the descriptors and indicators were tested at rest, during non nociceptive stimulation and nociceptive stimulation (turning) in a sample of 116 brain-injured ICLI patients who were hospitalized in two university centers. Results showed important variations in the descriptors observed during the nociceptive stimulation, probably due to the heterogeneity of patients' level of consciousness. Ten descriptors were excluded, as they were observed less than 5% of the time or their reliability was insufficient. All physiologic descriptors were deleted as they showed little variability and inter observer reliability was lacking. Concomitant validity, testing the association between patients' self report of pain and measures performed using the descriptors, was acceptable during nociceptive stimulation (rs=0,527, p=0,003, n=30). However, convergent validity ( testing for an association between the nurses' pain assessment and measures done with descriptors) and divergent validity (testing for the ability of the indicators to discriminate between rest and a nociceptive stimulation) varied according to the level of consciousness These results highlight the need to study pain descriptors in brain-injured patients with different level of consciousness and to take into account the heterogeneity of this population forthe conception of a pain assessment tool for nonverbal brain-injured ICU patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To study changes in survival, in biological activities and behavior of planorbids submitted to increased hydrostatic pressure, we developed a technique using two transparent chambers and a hydraulic piston. The apparatus permitted renewal of the liquid medium without substantial variations in pressure, thus eliminating excretion products and maintaining the desired O2 level and thereby permitting us to evaluate the effects of pressure independently of the occurrence of anoxia. Pressure was maintained without any contact of the liquid medium with compressed air, a situation which reproduced with relative fidelity what occurs in nature and assured the presence of the same amounts of gases in the two observation chambers (Control and Experimental). Biomphalaria glabrata was found to be able to survive at least 48 hours when submitted to 49.02 x 10**4 Pa (equivalent to a water depth of 48.8 m), continuing to day egg masses and showing few behavioral changes when compared with the control group.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Glucocorticoids are used to treat macular edema, although the mechanisms underlying this effect remain largely unknown. The authors have evaluated in the normal and endotoxin-induced uveitis (EIU) rats, the effects of dexamethasone (dex) and triamcinolone acetonide (TA) on potassium channel Kir4.1 and aquaporin-4 (AQP4), the two main retinal Müller glial (RMG) channels controlling retinal fluid movement. METHODS: Clinical as well as relatively low doses of dex and TA were injected in the vitreous of normal rats to evaluate their influence on Kir4.1 and AQP4 expression 24 hours later. The dose-dependent effects of the two glucocorticoids were investigated using rat neuroretinal organotypic cultures. EIU was induced by footpad lipopolysaccharide injection, without or with 100 nM intraocular dex or TA. Glucocorticoid receptor and channel expression levels were measured by quantitative PCR, Western blot, and immunohistochemistry. RESULTS: The authors found that dex and TA exert distinct and specific channel regulations at 24 hours after intravitreous injection. Dex selectively upregulated Kir4.1 (not AQP4) in healthy and inflamed retinas, whereas TA induced AQP4 (not Kir4.1) downregulation in normal retina and upregulation in EIU. The lower concentration (100 nM) efficiently regulated the channels. Moreover, in EIU, an inflammatory condition, the glucocorticoid receptor was downregulated in the retina, which was prevented by intravitreous injections of the low concentration of dex or TA. CONCLUSIONS: The results show that dex and TA are far from being equivalent to modulate RMG channels. Furthermore, the authors suggest that low doses of glucocorticoids may have antiedematous effects on the retina with reduced toxicity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract: This article presents both a brief systemic intervention method (IBS) consisting in 6 sessions developed in an ambulatory service for couples and families, and two research projects done in collaboration with the Institute for Psychotherapy of the University of Lausanne. The first project is quantitative and it aims at evaluating the effectiveness of ISB. One of its main feature is that outcomes are assessed at different levels of individual and family functioning: 1) symptoms and individual functioning; 2) quality of marital relationship; 3) parental and co-parental relationships; 4) familial relationships. The second project is a qualitative case study about a marital therapy which identifies and analyses significant moments of the therapeutic process from the patients' perspective. Methodology was largely inspired by Daniel Stem's work about "moments of meeting" in psychotherapy. Results show that patients' theories about relationship and change are important elements that deepen our understanding of the change process in couple and family therapy. The interest of associating clinicians and researchers for the development and validation of a new clinical model is discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The World Health Organization (WHO) criteria for the diagnosis of osteoporosis are mainly applicable for dual X-ray absorptiometry (DXA) measurements at the spine and hip levels. There is a growing demand for cheaper devices, free of ionizing radiation such as promising quantitative ultrasound (QUS). In common with many other countries, QUS measurements are increasingly used in Switzerland without adequate clinical guidelines. The T-score approach developed for DXA cannot be applied to QUS, although well-conducted prospective studies have shown that ultrasound could be a valuable predictor of fracture risk. As a consequence, an expert committee named the Swiss Quality Assurance Project (SQAP, for which the main mission is the establishment of quality assurance procedures for DXA and QUS in Switzerland) was mandated by the Swiss Association Against Osteoporosis (ASCO) in 2000 to propose operational clinical recommendations for the use of QUS in the management of osteoporosis for two QUS devices sold in Switzerland. Device-specific weighted "T-score" based on the risk of osteoporotic hip fractures as well as on the prediction of DXA osteoporosis at the hip, according to the WHO definition of osteoporosis, were calculated for the Achilles (Lunar, General Electric, Madison, Wis.) and Sahara (Hologic, Waltham, Mass.) ultrasound devices. Several studies (totaling a few thousand subjects) were used to calculate age-adjusted odd ratios (OR) and area under the receiver operating curve (AUC) for the prediction of osteoporotic fracture (taking into account a weighting score depending on the design of the study involved in the calculation). The ORs were 2.4 (1.9-3.2) and AUC 0.72 (0.66-0.77), respectively, for the Achilles, and 2.3 (1.7-3.1) and 0.75 (0.68-0.82), respectively, for the Sahara device. To translate risk estimates into thresholds for clinical application, 90% sensitivity was used to define low fracture and low osteoporosis risk, and a specificity of 80% was used to define subjects as being at high risk of fracture or having osteoporosis at the hip. From the combination of the fracture model with the hip DXA osteoporotic model, we found a T-score threshold of -1.2 and -2.5 for the stiffness (Achilles) determining, respectively, the low- and high-risk subjects. Similarly, we found a T-score at -1.0 and -2.2 for the QUI index (Sahara). Then a screening strategy combining QUS, DXA, and clinical factors for the identification of women needing treatment was proposed. The application of this approach will help to minimize the inappropriate use of QUS from which the whole field currently suffers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intraoperative cardiac imaging plays a key role during transcatheter aortic valve replacement. In recent years, new techniques and new tools for improved image quality and virtual navigation have been proposed, in order to simplify and standardize stent valve positioning and implantation. But routine performance of the new techniques may require major economic investments or specific knowledge and skills and, for this reason, they may not be accessible to the majority of cardiac centres involved in transcatheter valve replacement projects. Additionally, they still require injections of contrast medium to obtain computed images. Therefore, we have developed and describe here a very simple and intuitive method of positioning balloon-expandable stent valves, which represents the evolution of the 'dumbbell' technique for echocardiography-guided transcatheter valve replacement without angiography. This method, based on the partial inflation of the balloon catheter during positioning, traps the crimped valve in the aortic valve orifice and, consequently, very near to the ideal landing zone. It does not require specific echocardiographic knowledge; it does not require angiographies that increase the risk of postoperative kidney failure in elderly patients, and it can be also performed in centres not equipped with a hybrid operating room.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

When Bank of England (and the Federal Reserve Board) introduced their quantitative easing (QE) operations they emphasised the effects on money and credit, but much of their empirical research on the effects of QE focuses on long-term interest rates. We use a flow of funds matrix with an independent central bank to show the implications of QE and other monetary developments, and argue that the financial crisis, the fiscal expansion and QE are likely to have constituted major exogenous shocks to money and credit in the UK which could not be digested immediately by the usual adjustment mechanisms. We present regressions of a reduced form model which considers the growth of nominal spending as determined by the growth of nominal money and other variables. These results suggest that money was not important during the Great Moderation but has had a much larger role in the period of the crisis and QE. We then use these estimates to illustrate the effects of the financial crisis and QE. We conclude that it would be useful to incorporate money and/or credit in wider macroeconometric models of the UK economy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and rapid staphylococcal coagglutination test for the detection of Toxoplasma gondii antigens in mice urine is described. A suspension of protein-A containing Staphylococcus aureus coated with rabbit hyperimmune serum was used as reagent. The sensitivity of the antigen assay was found to be at least 118 ng of the antigen protein per ml. No coagglutination was observed when the reagent was challenged against antigenic solutions of other parasites. The suitability of the method for detecting antigens of T. gondii in urine samples was studied by experimental toxoplasma infection in mice. Before the staphylococcal test, the urine samples were double serially diluted in 0.1 M PBS. From the second day on all samples from infected mice were positive at 1/16 dilution. At this dilution, all samples from non infected mice were negative or did not produce coagglutination. This method might be used in the rapid etiological diagnosis also in human cases of acute toxoplasmosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUME Durant les dernières années, les méthodes électriques ont souvent été utilisées pour l'investigation des structures de subsurface. L'imagerie électrique (Electrical Resistivity Tomography, ERT) est une technique de prospection non-invasive et spatialement intégrée. La méthode ERT a subi des améliorations significatives avec le développement de nouveaux algorithmes d'inversion et le perfectionnement des techniques d'acquisition. La technologie multicanale et les ordinateurs de dernière génération permettent la collecte et le traitement de données en quelques heures. Les domaines d'application sont nombreux et divers: géologie et hydrogéologie, génie civil et géotechnique, archéologie et études environnementales. En particulier, les méthodes électriques sont souvent employées dans l'étude hydrologique de la zone vadose. Le but de ce travail est le développement d'un système de monitorage 3D automatique, non- invasif, fiable, peu coûteux, basé sur une technique multicanale et approprié pour suivre les variations de résistivité électrique dans le sous-sol lors d'événements pluvieux. En raison des limitations techniques et afin d'éviter toute perturbation physique dans la subsurface, ce dispositif de mesure emploie une installation non-conventionnelle, où toutes les électrodes de courant sont placées au bord de la zone d'étude. Le dispositif le plus approprié pour suivre les variations verticales et latérales de la résistivité électrique à partir d'une installation permanente a été choisi à l'aide de modélisations numériques. Les résultats démontrent que le dispositif pôle-dipôle offre une meilleure résolution que le dispositif pôle-pôle et plus apte à détecter les variations latérales et verticales de la résistivité électrique, et cela malgré la configuration non-conventionnelle des électrodes. Pour tester l'efficacité du système proposé, des données de terrain ont été collectées sur un site d'étude expérimental. La technique de monitorage utilisée permet de suivre le processus d'infiltration 3D pendant des événements pluvieux. Une bonne corrélation est observée entre les résultats de modélisation numérique et les données de terrain, confirmant par ailleurs que le dispositif pôle-dipôle offre une meilleure résolution que le dispositif pôle-pôle. La nouvelle technique de monitorage 3D de résistivité électrique permet de caractériser les zones d'écoulement préférentiel et de caractériser le rôle de la lithologie et de la pédologie de manière quantitative dans les processus hydrologiques responsables d'écoulement de crue. ABSTRACT During the last years, electrical methods were often used for the investigation of subsurface structures. Electrical resistivity tomography (ERT) has been reported to be a useful non-invasive and spatially integrative prospecting technique. The ERT method provides significant improvements, with the developments of new inversion algorithms, and the increasing efficiency of data collection techniques. Multichannel technology and powerful computers allow collecting and processing resistivity data within few hours. Application domains are numerous and varied: geology and hydrogeology, civil engineering and geotechnics, archaeology and environmental studies. In particular, electrical methods are commonly used in hydrological studies of the vadose zone. The aim of this study was to develop a multichannel, automatic, non-invasive, reliable and inexpensive 3D monitoring system designed to follow electrical resistivity variations in soil during rainfall. Because of technical limitations and in order to not disturb the subsurface, the proposed measurement device uses a non-conventional electrode set-up, where all the current electrodes are located near the edges of the survey grid. Using numerical modelling, the most appropriate arrays were selected to detect vertical and lateral variations of the electrical resistivity in the framework of a permanent surveying installation system. The results show that a pole-dipole array has a better resolution than a pole-pole array and can successfully follow vertical and lateral resistivity variations despite the non-conventional electrode configuration used. Field data are then collected at a test site to assess the efficiency of the proposed monitoring technique. The system allows following the 3D infiltration processes during a rainfall event. A good correlation between the results of numerical modelling and field data results can be observed since the field pole-dipole data give a better resolution image than the pole-pole data. The new device and technique makes it possible to better characterize the zones of preferential flow and to quantify the role of lithology and pedology in flood- generating hydrological processes.