977 resultados para QA


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Host-parasitoid models including integrated pest management (IPM) interventions with impulsive effects at both fixed and unfixed times were analyzed with regard to host-eradication, host-parasitoid persistence and host-outbreak solutions. The host-eradication periodic solution with fixed moments is globally stable if the host's intrinsic growth rate is less than the summation of the mean host-killing rate and the mean parasitization rate during the impulsive period. Solutions for all three categories can coexist, with switch-like transitions among their attractors showing that varying dosages and frequencies of insecticide applications and the numbers of parasitoids released are crucial. Periodic solutions also exist for models with unfixed moments for which the maximum amplitude of the host is less than the economic threshold. The dosages and frequencies of IPM interventions for these solutions are much reduced in comparison with the pest-eradication periodic solution. Our results, which are robust to inclusion of stochastic effects and with a wide range of parameter values, confirm that IPM is more effective than any single control tactic.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The finite element method plays an extremely important role in forging process design as it provides a valid means to quantify forging errors and thereby govern die shape modification to improve the dimensional accuracy of the component. However, this dependency on process simulation could raise significant problems and present a major drawback if the finite element simulation results were inaccurate. This paper presents a novel approach to assess the dimensional accuracy and shape quality of aeroengine blades formed from finite element hot-forging simulation. The proposed virtual inspection system uses conventional algorithms adopted by modern coordinate measurement processes as well as the latest free-form surface evaluation techniques to provide a robust framework for virtual forging error assessment. Established techniques for the physical registration of real components have been adapted to localise virtual models in relation to a nominal Design Coordinate System. Blades are then automatically analysed using a series of intelligent routines to generate measurement data and compute dimensional errors. The results of a comparison study indicate that the virtual inspection results and actual coordinate measurement data are highly comparable, validating the approach as an effective and accurate means to quantify forging error in a virtual environment. Consequently, this provides adequate justification for the implementation of the virtual inspection system in the virtual process design, modelling and validation of forged aeroengine blades in industry.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: In this study the Octavius detector 729 ionization chamber (IC) array with the Octavius 4D phantom was characterized for flattening filter (FF) and flattening filter free (FFF) static and rotational beams. The device was assessed for verification with FF and FFF RapidArc treatment plans.

Methods: The response of the detectors to field size, dose linearity, and dose rate were assessed for 6 MV FF beams and also 6 and 10 MV FFF beams. Dosimetric and mechanical accuracy of the detector array within the Octavius 4D rotational phantom was evaluated against measurements made using semiflex and pinpoint ionization chambers, and radiochromic film. Verification FF and FFF RapidArc plans were assessed using a gamma function with 3%/3 mm tolerances and 2%/2 mm tolerances and further analysis of these plans was undertaken using film and a second detector array with higher spatial resolution.

Results: A warm-up dose of >6 Gy was required for detector stability. Dose-rate measurements were stable across a range from 0.26 to 15 Gy/min and dose response was linear, although the device overestimated small doses compared with pinpoint ionization chamber measurements. Output factors agreed with ionization chamber measurements to within 0.6% for square fields of side between 3 and 25 cm and within 1.2% for 2 x 2 cm(2) fields. The Octavius 4D phantom was found to be consistent with measurements made with radiochromic film, where the gantry angle was found to be within 0.4. of that expected during rotational deliveries. RapidArc FF and FFF beams were found to have an accuracy of >97.9% and >90% of pixels passing 3%/3 mm and 2%/2 mm, respectively. Detector spatial resolution was observed to be a factor in determining the accurate delivery of each plan, particularly at steep dose gradients. This was confirmed using data from a second detector array with higher spatial resolution and with radiochromic film.

Conclusions: The Octavius 4D phantom with associated Octavius detector 729 ionization chamber array is a dosimetrically and mechanically stable device for pretreatment verification of FF and FFF RapidArc treatments. Further improvements may be possible through use of a detector array with higher spatial resolution (detector size and/or detector spacing). (C) 2013 American Association of Physicists in Medicine.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present an implementation of quantum annealing (QA) via lattice Green's function Monte Carlo (GFMC), focusing on its application to the Ising spin glass in transverse field. In particular, we study whether or not such a method is more effective than the path-integral Monte Carlo- (PIMC) based QA, as well as classical simulated annealing (CA), previously tested on the same optimization problem. We identify the issue of importance sampling, i.e., the necessity of possessing reasonably good (variational) trial wave functions, as the key point of the algorithm. We performed GFMC-QA runs using such a Boltzmann-type trial wave function, finding results for the residual energies that are qualitatively similar to those of CA (but at a much larger computational cost), and definitely worse than PIMC-QA. We conclude that, at present, without a serious effort in constructing reliable importance sampling variational wave functions for a quantum glass, GFMC-QA is not a true competitor of PIMC-QA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We investigate the basic behavior and performance of simulated quantum annealing (QA) in comparison with classical annealing (CA). Three simple one-dimensional case study systems are considered: namely, a parabolic well, a double well, and a curved washboard. The time-dependent Schrodinger evolution in either real or imaginary time describing QA is contrasted with the Fokker-Planck evolution of CA. The asymptotic decrease of excess energy with annealing time is studied in each case, and the reasons for differences are examined and discussed. The Huse-Fisher classical power law of double-well CA is replaced with a different power law in QA. The multiwell washboard problem studied in CA by Shinomoto and Kabashima and leading classically to a logarithmic annealing even in the absence of disorder turns to a power-law behavior when annealed with QA. The crucial role of disorder and localization is briefly discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Homotypic fusion between early endosomes requires the phosphatidylinositol 3-phosphate (PI3P)-binding protein, Early Endosomal Autoantigen 1 (EEA1). We have investigated the role of other proteins that interact with EEA1 in the fusion of early endosomes derived from Baby Hamster Kidney (BHK) cells. We confirm a requirement for syntaxin 13, but additionally show that the assay is equally sensitive to reagents specifically targeted against syntaxin 6. Binding of EEA1 to immobilised GST-syntaxin 6 and 13 was directly compared; only syntaxin 6 formed a stable complex with EEA1. Early endosome fusion requires the release of intravesicular calcium, and calmodulin plays a vital role in the fusion pathway, as judged by sensitivity to antagonists. We demonstrate that both EEA1 and syntaxin 13 interact with calmodulin. In the case of EEA1, binding to calmodulin requires an IQ domain, which is adjacent to a C-terminal FYVE domain that specifically binds to PI3P. We have assessed the influence of protein binding partners on EEA1 interaction with PI3P and find that both calmodulin and rab5-GTP are antagonistic to PI3P binding, whilst syntaxins 6 and 13 have no effect. These studies reveal a complex network of interactions between the proteins required for endosome fusion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Selective GLP-1 secretagogues represent a novel potential therapy for type 2 diabetes mellitus. This study examined the GLP-1 secretory activity of the ethnomedicinal plant, Fagonia cretica, which is postulated to possess anti-diabetic activity. After extraction and fractionation extracts and purified compounds were tested for GLP-1 and GIP secretory activity in STC-1 pGIP/neo cells. Intracellular levels of incretin hormones and their gene expression were also determined. Crude F. cretica extracts stimulated both GLP-1 and GIP secretion, increased cellular hormone content, and upregulated gene expression of proglucagon, GIP and prohormone convertase. However, ethyl acetate partitioning significantly enriched GLP-1 secretory activity and this fraction underwent bioactivity-guided fractionation. Three isolated compounds were potent and selective GLP-1 secretagogues: quinovic acid (QA) and two QA derivatives, QA-3β-O-β-D-glycopyranoside and QA-3β-O-β-D-glucopyranosyl-(28→1)-β-D-glucopyranosyl ester. All QA compounds activated the TGR5 receptor and increased intracellular incretin levels and gene expression. QA derivatives were more potent GLP-1 secretagogues than QA. This is the first time that QA and its naturally-occurring derivatives have been shown to activate TGR5 and stimulate GLP-1 secretion. These data provide a plausible mechanism for the ethnomedicinal use of F. cretica and may assist in the ongoing development of selective GLP-1 agonists.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To provide a tool to enable gamma analysis software algorithms to be included in a quality assurance (QA) program.

METHODS: Four image sets were created comprising two geometric images to independently test the distance to agreement (DTA) and dose difference (DD) elements of the gamma algorithm, a clinical step and shoot IMRT field and a clinical VMAT arc. The images were analysed using global and local gamma analysis with 2 in-house and 8 commercially available software encompassing 15 software versions. The effect of image resolution on gamma pass rates was also investigated.

RESULTS: All but one software accurately calculated the gamma passing rate for the geometric images. Variation in global gamma passing rates of 1% at 3%/3mm and over 2% at 1%/1mm was measured between software and software versions with analysis of appropriately sampled images.

CONCLUSION: This study provides a suite of test images and the gamma pass rates achieved for a selection of commercially available software. This image suite will enable validation of gamma analysis software within a QA program and provide a frame of reference by which to compare results reported in the literature from various manufacturers and software versions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Joint master programmes are systems which by default demand a proper quality system in order to sustain and improve. Objective of this thesis is analysing and proposing solutions to difficulties associated with the implementation of a quality management system to joint master programmes, with the focus on international joint master programmes. The application of the analysis to the Erasmus Mundus joint master programme European Master in Quality in Analytical Laboratories (EMQAL) is discussed. QA systems implementation in HEIs in Europe is an ongoing process, and implementation of such systems in JPs is one step further to enhancing quality in higher education in Europe. The issue closely discussed in this thesis is: should QMS be developed independently from the institutions, or should the institutions, when developing their quality management systems, take into account the (future) development of joint courses and prepare their quality procedures accordingly? A quality management system is normally developed for one organization, and different aspects of cooperation are considered within. A joint master programme is a result of successful cooperation of two or more organizations; therefore a development of its quality management system must be approached in a different manner. This thesis proposes a QMS with emphasis both on the HEI and the consortium. Different processes in the QMS can be managed independently at the level of the HEI or at the level of the consortium. Most processes in joint master programmes should be designed in programmes’ and institutions’ QMSs. Quality of a joint master programme cannot be analyzed separately from the higher education institutions which are organizing it. Comparative analysis of organization of one Erasmus Mundus Master programme to the solutions proposed in discussion showed that from all of the aspects considered, processes in EMQAL are organized in harmony with the proposed delegation of processes of the QMS for a joint master programme. The solutions proposed in the discussion are based on theoretical application of the quality principles and concepts. Comparison to the quality processes and procedures in an existing EM programme showed that analysis is applicable in practice.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tese de doutoramento, Ciências Biomédicas, Universidade do Algarve, Departamento de Ciências Biomédicas e Medicina, 2014

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tese de doutoramento, Informática (Ciências da Computação), Universidade de Lisboa, Faculdade de Ciências, 2015

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study explored experiences in relation to the impact of the College of Nurses of Ontario's (CNO's) mandatory Quality Assurance (QA) program on registered nurses (RNs) working in a clinical setting of an acute care hospital. A qualitative descriptive research design was used and data collection was done in 2 stages. First, a survey with open-ended questions was given to 45 nurses. Second, 8 respondents from the survey were interviewed using a semistructured format. Data were obtained from 2 groups-diploma-prepared and post diploma-prepared RNs. Findings demonstrated that the CNO's QA program had varying influences on the RNs' learning paths, and these differences appeared to be related to the educational background of the individual. The diploma-prepared nurses reported that their commitment to professional development was influenced by their level of internal motivation, the pressures associated with time, and the need for a strong external motivator, namely the obligation of management to conduct formal performance appraisals. They further reported that the QA program played a part in positively altering their commitment to continuing education. The post-diploma baccalaureate nurses reported that the QA program played a positive role in influencing their ongoing learning, along with their level of internal motivation, the work and health care environment, and the element of professionalism. Several implications for nursing practice, theory, and fiirther research also became evident.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Health regulatory colleges promote quality practice and continued competence through Quality Assurance (QA) programs. For many colleges, a QA program includes the use of portfolios that incorporate self-directed learning. The purpose of this study was to determine some of the issues surrounding the effectiveness of QA portfolio programs. The literature review revealed that portfolios are valuable tools, but gaps in knowledge include a comparative analysis of QA programs and the perspective of regulatory college administrators. Data were collected through interviews with 6 administrators and a review of 14 portfolio models described on college websites. The results from the two data sources were applied to Robert Stake's responsive evaluation framework to identify issues related to the portfolio's effectiveness (Stake, 1967). The learning components of portfolios were analyzed through the humanist and constructivist lenses. All 14 portfolio models were found to have 3 main components: self-diagnosis, learning plan and activities, and self-evaluation. However, differences were uncovered in learners' autonomy in selecting learning activities, methods of portfolio evaluation, and the relationship between the portfolio and other QA components. The results revealed a dual philosophy of learning in portfolio models and an apparent contradiction between the needs of the individual learner and the organization. Paths for future research include the tenuous relationship between competence and learning, and the impact of technical approaches on selfdirected learning initiatives. A key recommendation is to acknowledge the unique identity of each profession so that health regulatory colleges can address legislative demands and learner needs.