969 resultados para Premature ventricular contraction
Resumo:
It has not been well established whether the mechanisms participating in pH regulation in the anoxic-reoxygenated developing myocardium resemble those operating in the adult. We have specially examined the importance of Na+/H+ exchange (NHE) and HCO3-dependent transports in cardiac activity after changes in extracellular pH (pHo). Spontaneously contracting hearts isolated from 4-day-old chick embryos were submitted to single or repeated anoxia (1 min) followed by reoxygenation (10 min). The chronotropic, dromotropic and inotropic responses of the hearts were determined in standard HCO3- buffer at pHo 7.4 and at pHo 6.5 (hypercapnic acidosis). In distinct experiments, acidotic anoxia preceded reoxygenation at pHo 7.4. NHE was blocked with amiloride derivative HMA (1 micro mol/l) and HCO3-dependent transports were inactivated by replacement of HCO3 or blockade with stilbene derivative DIDS (100 micro mol/l). Anoxia caused transient tachycardia, depressed mechanical function and induced contracture. Reoxygenation temporarily provoked cardiac arrest, atrio-ventricular (AV) block, arrhythmias and depression of contractility. Addition of DIDS or substitution of HCO3 at pHo 7.4 had the same effects as acidosis per se, i.e. shortened contractile activity and increased incidence of arrhythmias during anoxia, prolonged cardioplegia and provoked arrhythmias at reoxygenation. Under anoxia at pHo 6.5/reoxygenation at pHo 7.4, cardioplegia, AV block and arrhythmias were all markedly prolonged. Interestingly, in the latter protocol, DIDS suppressed AV block and arrhythmias during reoxygenation, whereas HMA had no effect. Thus, intracellular pH regulation in the anoxic-reoxygenated embryonic heart appears to depend predominantly on HCO3 availability and transport. Furthermore, pharmacological inhibition of anion transport can protect against reoxygenation-induced dysfunction.
Resumo:
Contexte : L'insuffisance cardiaque touche environ 150 personnes sur 100'000 habitants en Suisse, avec une¦prévalence évaluée à 1.45 %, et cause 42.3 décès par 100'000 habitants. Globalement, la prévalence de¦l'insuffisance cardiaque augmente, d'une part à cause du vieillissement de la population, d'autre part par¦l'amélioration de la prise en charge de pathologies cardiaques. La transplantation reste actuellement le gold¦standard pour l'insuffisance cardiaque réfractaire au traitement pharmacologique, mais les organes sont¦rares. Une alternative a donc été développée, celle des systèmes d'assistance ventriculaire (ventricular assist¦device, VAD). Les appareils existants actuellement sur le marché fonctionnent en déviant le sang du¦ventricule vers un système de projection à flux pulsatile ou continu placé dans la cage thoracique, avant de le¦renvoyer vers l'artère. Ils comportent certains défauts, en particulier la nécessité de léser le coeur pour les¦implanter et les risques hémorragique et thrombo-embolique importants. Pour remédier à ces défauts, des¦VAD externes sont en cours de développement. Fixés autour du coeur, ils permettent de l'assister dans la¦contraction, sans contact direct avec le sang ni lésion du coeur. Dans cette étude, nous avons créé deux¦prototypes de VAD externes basés sur la technique du muscle artificiel. Ils sont faits de fils de Nitinol, un¦alliage à mémoire de forme qui raccourcit lorsqu'il est chauffé. Placés autour du coeur, ils lui impriment un¦mouvement de contraction, tel un muscle artificiel.¦Méthode : deux VAD externes ont été créés en utilisant du Nitinol. Les fibres de Nitinol du VAD N°1¦passent à travers des charnières qui augmentent son pouvoir de contraction. Celles du VAD N°2 sont¦orientées dans un maillage de fibres de Kevlar de manière à reproduire la direction des fibres musculaires du¦ventricule humain. Ils ont été testés sur un banc d'essai avec un coeur en silicone. Nous avons mesuré la¦fraction d'éjection, le débit et la pression générée, à différentes valeurs de précharge et post-charge. Les¦VAD étaient alimentés par une génératrice ou par une unité de contrôle, qui permettait de fournir l'énergie¦précisément dans chaque fil de Nitinol et d'imposer une certaine fréquence cardiaque.¦Résultats : Tant avec la génératrice que l'unité de contrôle, le ventricule gauche du VAD N°1 fournit une¦fraction d'éjection maximale de 16.09 %. Le débit maximal est de 191.42 ml/min. La génératrice permet au¦VAD N°2 de fournir une fraction d'éjection de 6.18 %, contre 2.48 % avec l'unité de contrôle. Le débit¦maximal est de 27.37 ml/min. La pression générée atteint 75 mmHg pour le VAD N°1 et 6 mmHg pour le¦VAD N°2.¦Discussion/conclusion : Le VAD N°1 est le plus performant, il permet une augmentation significative de la¦fraction d'éjection et pourrait avoir un impact sur la qualité de vie des patients. L'unité de contrôle apporte¦un avantage sur la génératrice pour le VAD N°1, en dirigeant plus précisément l'énergie dans les fils de¦Nitinol et en limitant les pertes. Le VAD N°2, lui, est peu performant et l'unité de contrôle n'améliore pas¦ses performances. Cela est probablement dû à sa configuration initiale, la taille du VAD n'étant pas adaptée¦au coeur en silicone. Cette étude prouve qu'il est possible d'assister un coeur depuis l'extérieur, sans l'altérer,¦et que la position des fibres de Nitinol a plus d'importance que leur nombre.
Resumo:
Objective: Existing VADs are single-ventricle pumps needing anticoagulation. We developed a bi ventricular external assist device that reproduces the physiological heart muscle movement completely avoiding anticoagulants. Methods: The device has a carbon fibre skeleton fitting a 30-40 kg patient's heart, to which a Nitinol based artificial muscle is connected. The artificial muscle wraps both ventricles. The strength of the Nitinol fibres is amplified by a pivot articulation in contact with the ventricle wall. The fibres are electrically driven and a dedicated control unit has been developed. We assessed hemodynamic performances of this device using a previously described dedicated bench test. Volume ejected and pressure gradient has been measured with afterload ranging from 25 to 50mmHg. Results: With anafterload of 50mmHg the system has an ejection fraction (EF) of 10% on the right side and 8% on the left side. The system is able to generate a systolic ejection of 5,5 ml on the right side and 4,4 ml on the left side. With anafterload of 25mmHg the results are reduced of about 20%. The activation frequency is 80/minute resulting in a total volume displacement of 440 ml/minute on the right side and 352 ml/minute on the left side. Conclusions: The artificial muscle follows Starling's law as the ejected volume increases when afterload increases. These preliminary studies confirmed the possibility of improving the EF of a failing heart using artificial muscle for external cardiac compression. This device could be helpful in weaning CPB and/or for short-term cardio-circulatory support in paediatric population with cardiac failure.
Resumo:
Forty-six consecutive patients with pulmonary embolism (PE) who underwent pulmonary angiography, helical computed tomography (CT), and echocardiography in the investigators' emergency department were studied. It was determined that the CT right ventricular (RV)/left ventricular (LV) end-diastolic area ratio was correlated with PE obstruction and echocardiography. A CT RV/LV area ratio >1 had a sensitivity of 88% and a specificity of 88% in diagnosing significant PE. The present study suggests that helical CT may be used as a triage tool in acute PE for selecting high-risk patients, using calculation of the RV/LV area ratio to detect RV dysfunction.
Resumo:
INTRODUCTION: A significant proportion of prematurely born children encounter behavioral difficulties, such as attention deficit or hyperactivity, which could be due to executive function disorders. AIMS: To examine whether the standard neurodevelopmental assessment offered to premature children in Switzerland recognizes executive function disorders. METHODS: The study population consisted of 49 children born before 29 weeks of gestation who were examined between 5 and 6 years of age with a standard assessment, with additional items to assess executive functioning. Children with severe neurodevelopmental impairment were excluded (mental retardation, cerebral palsy, autism). Standard assessment consisted in the Kaufman Assessment Battery for Children (K-ABC), which comprises three subscales: sequential processes (analysis of sequential information), simultaneous processes (global analysis of visual information), and composite mental processes (CMP) (result of the other two scales), as well as a behavioral evaluation using the standardized Strengths and Difficulties Questionnaire (SDQ). Executive functioning was assessed with tasks evaluating visual attention, divided attention, and digit memory as well as with a specialized questionnaire, the Behavior Rating Index of Executive Functions (BRIEF), which evaluates several aspects of executive function (regulation, attention, flexibility, working memory, etc). RESULTS: Children were divided according to their results on the three K-ABC scales (< or>85), and the different neuropsychological tasks assessing executive function were compared between the groups. The CMP did not differentiate children with executive difficulties, whereas a score<85 on the sequential processes was significantly associated with worse visual and divided attention. There was a strong correlation between the SDQ and the BRIEF questionnaires. For both questionnaires, children receiving psychotherapy had significantly higher results. Children who presented behavioral problems assessed with the SDQ presented significantly higher scores on the BRIEF. CONCLUSION: A detailed analysis of the standard neurodevelopmental assessment allows the identification of executive function disorders in premature children. Children who performed below 85 on the sequential processes of the K-ABC had significantly more attentional difficulties on the neuropsychological tasks and therefore have to be recognized and carefully followed. Emotional regulation had a strong correlation with behavioral difficulties, which were suitably assessed with the SDQ, recognized by the families, and treated.
Long-term continuous-flow left ventricular assist devices (LVAD) as bridge to heart transplantation.
Resumo:
Heart transplantation (HTx) is the treatment of choice for end-stage heart failure but the limited availability of heart's donors still represents a major issue. So long-term mechanical circulatory support (MCS) has been proposed as an alternative treatment option to assist patients scheduled on HTx waiting list bridging them for a variable time period to cardiac transplantation-the so-called bridge-to-transplantation (BTT) strategy. Nowadays approximately 90% of patients being considered for MCS receive a left ventricular assist device (LVAD). In fact, LVAD experienced several improvements in the last decade and the predominance of continuous-flow over pulsatile-flow technology has been evident since 2008. The aim of the present report is to give an overview of continuous-flow LVAD utilization in the specific setting of the BTT strategy taking into consideration the most representative articles of the scientific literature and focusing the attention on the evolution, clinical outcomes, relevant implications on the HTx strategy and future perspectives of the continuous-flow LVAD technology.
Resumo:
Gelled aspect in papaya fruit is typically confused with premature ripening. This research reports the characterization of this physiological disorder in the pulp of papaya fruit by measuring electrolyte leakage, Pi content, lipid peroxidation, pulp firmness, mineral contents (Ca, Mg and K - in pulp and seed tissues), and histological analysis of pulp tissue. The results showed that the gelled aspect of the papaya fruit pulp is not associated with tissue premature ripening. Data indicate a reduction of the vacuole water intake as the principal cause of the loss of cellular turgor; while the waterlogged aspect of the tissue may be due to water accumulation in the apoplast.
Resumo:
Assisted reproductive technologies (ART) predispose the offspring to vascular dysfunction, arterial hypertension, and hypoxic pulmonary hypertension. Recently, cardiac remodeling and dysfunction during fetal and early postnatal life have been reported in offspring of ART, but it is not known whether these cardiac alterations persist later in life and whether confounding factors contribute to this problem. We, therefore, assessed cardiac function and pulmonary artery pressure by echocardiography in 54 healthy children conceived by ART (mean age 11.5 ± 2.4 yr) and 54 age-matched (12.2 ± 2.3 yr) and sex-matched control children. Because ART is often associated with low birth weight and prematurity, two potential confounders associated with cardiac dysfunction, only singletons born with normal birth weight at term were studied. Moreover, because cardiac remodeling in infants conceived by ART was observed in utero, a situation associated with increased right heart load, we also assessed cardiac function during high-altitude exposure, a condition associated with hypoxic pulmonary hypertension-induced right ventricular overload. We found that, while at low altitude cardiac morphometry and function was not different between children conceived by ART and control children, under the stressful conditions of high-altitude-induced pressure overload and hypoxia, larger right ventricular end-diastolic area and diastolic dysfunction (evidenced by lower E-wave tissue Doppler velocity and A-wave tissue Doppler velocity of the lateral tricuspid annulus) were detectable in children and adolescents conceived by ART. In conclusion, right ventricular dysfunction persists in children and adolescents conceived by ART. These cardiac alterations appear to be related to ART per se rather than to low birth weight or prematurity.
Resumo:
BACKGROUND: There is considerable interindividual variability in pulmonary artery pressure among high-altitude (HA) dwellers, but the underlying mechanism is not known. At low altitude, a patent foramen ovale (PFO) is present in about 25% of the general population. Its prevalence is increased in clinical conditions associated with pulmonary hypertension and arterial hypoxemia, and it is thought to aggravate these problems. METHODS: We searched for a PFO (transesophageal echocardiography) in healthy HA dwellers (n = 22) and patients with chronic mountain sickness (n = 35) at 3,600 m above sea level and studied its effects (transthoracic echocardiography) on right ventricular (RV) function, pulmonary artery pressure, and vascular resistance at rest and during mild exercise (50 W), an intervention designed to further increase pulmonary artery pressure. RESULTS: The prevalence of PFO (32%) was similar to that reported in low-altitude populations and was not different in participants with and without chronic mountain sickness. Its presence was associated with RV enlargement at rest and an exaggerated increase in right-ventricular-to-right-atrial pressure gradient (25 ± 7 mm Hg vs 15 ± 9 mm Hg, P < .001) and a blunted increase in fractional area change of the right ventricle (3% [-1%, 5%] vs 7% [3%, 16%], P = .008) during mild exercise. CONCLUSIONS: These findings show, we believe for the first time, that although the prevalence of PFO is not increased in HA dwellers, its presence appears to facilitate pulmonary vasoconstriction and RV dysfunction during a mild physical effort frequently associated with daily activity. TRIAL REGISTRY: ClinicalTrials.gov; No.: NCT01182792; URL: www.clinicaltrials.gov.
Resumo:
BACKGROUND: Whether being small for gestational age (SGA) increases the risk of adverse neurodevelopmental outcome in premature infants remains controversial. OBJECTIVE: to study the impact of SGA (birthweight < percentile 10) on cognition, behavior, neurodevelopmental impairment and use of therapy at 5 years old. METHODS: This population-based prospective cohort included infants born before 32 weeks of gestation. Cognition was evaluated with the K-ABC, and behavior with the Strengths and Difficulties Questionnaire (SDQ). Primary outcomes were cognitive and behavioral scores, as well as neurodevelopmental impairment (cognitive score < 2SD, hearing loss, blindness, or cerebral palsy). The need of therapy, an indirect indicator of neurodevelopmental impairment, was a secondary outcome. Linear and logistic regression models were used to analyze the association of SGA with neurodevelopment. RESULTS: 342/515 (76%) premature infants were assessed. SGA was significantly associated with hyperactivity scores of the SDQ (coefficient 0.81, p < 0.04), but not with cognitive scores, neurodevelopmental impairment or the need of therapy. Gestational age, socio-economic status, and major brain lesions were associated with cognitive outcome in the univariate and multivariate model, whereas asphyxia, sepsis and bronchopulmonary dysplasia were associated in the univariate model only. Severe impairment was associated with fetal tobacco exposition, asphyxia, gestational age and major brain lesions. Different neonatal factors were associated with the use of single or multiple therapies: children with one therapy were more likely to have suffered birth asphyxia or necrotizing enterocolitis, whereas the need for several therapies was predicted by major brain lesions. DISCUSSION: In this large cohort of premature infants, assessed at 5 years old with a complete panel of tests, SGA was associated with hyperactive behavior, but not with cognition, neurodevelopmental impairment or use of therapy. Birthweight <10th percentile alone does not appear to be an independent risk factor of neurodevelopmental adverse outcome in preterm children.