842 resultados para Plastic Pipe Extrusion


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Different plasticizers, including phosphate-, phthalate-and adipate-based types were used in the creation of a range of colorimetric plastic film sensors for CO2, The different types of plasticizer used in the formulation of a colorimetric plastic film sensor for CO2 affect the response and recovery times of the sensor differently, An effective plasticizer was taken as one that decreased the response and recovery times of the final film sensor when exposed to an alternating atmosphere of 0-5% CO2. On this basis, the most efficient plasticizers appeared to be phosphate-based, followed by phthalate- and adipate-based plasticizers, This trend appears to reflect the degree of the polymer-plasticizer compatibility. Increasing the amount of plasticizer in the film formulation decreased the response and recovery times of the sensor dramatically, The sensitivity of the film sensor towards CO2 appears to decrease with increasing plasticizer effectiveness; thus, the general order of film CO2 sensitivity with respect to plasticizer type was found to be adipate > phthalate > phosphate. In general, the response of the optical films towards CO2 was found to be temperature sensitive [typically, Delta H = -(44-55) kJ mol(-1)], The phosphate-based plasticized films appear to be less temperature sensitive than the other plasticized films, and 2-ethylhexyl diphenylphosphate appears particularly effective in this respect (Delta H = -18.5 kJ mol(-1)).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The preparation and characterization of three different plastic thin-film colorimetric sensors for gaseous ammonia is described. In the film sensors, the neutral form of a pH-sensitive dye (Bromophenol Blue, Bromocresol Green or Chlorophenol Red) was encapsulated in a plastic medium, either poly(vinyl butyral) or ethylcellulose plasticized with tributyl phosphate. Each of these film optodes gave a reproducible and reversible response towards gaseous ammonia. The sensitivity of the film sensors towards ammonia was found to be strongly dependent upon the pK(a) of the encapsulated dye. Thus, the film with Chlorophenol Red (pK(a) = 6.25), proved to be very insensitive (operating range: 0.29%

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The method of preparation of a novel plastic thin-film sensor that incorporates the fluorescent dye 8-hydroxypryrene-1,3,6-trisulfonic acid is described; the shelf-life of the film is over 6 months. The results of a study on the equilibrium response of the sensor towards different levels of gaseous CO2 fit a model there is a 1 + 1 equilibrium reaction between the deprotonated form of the dye (present in the film as an ion pair) and the concentration of gaseous CO2 present. In contrast to the situation in aqueous solution, in the plastic film the pK(a) of the excited form of the dye appears close to that of the ground-state form, although this does not interfere with its use as 8 CO2 sensor. The 0 to 90% response and recovery times of the film when exposed to an alternating atmosphere of air and 5% CO2 are typically 4.3 and 7.1 s, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The equilibrium responses of three new colorimetric plastic film sensors for CO2 as a function of % CO2 and temperature are described. The results fit a model in which there is a 1:1 equilibrium reaction between the deprotonated form of the dye (present in the film as an ion pair) and CO2. The 0-50% and 0-90% response and recovery times of each of these films when exposed to an alternating atmosphere of air and 5% CO2 are determined and in two cases are typically less than 3 s. The shelf life of the films is long (many months); however, prolonged use of the films leads to the permanent generation of the protonated form of the dye over a period of 20-100 h. A possible cause of this latter effect is discussed.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Melt viscosity is a key indicator of product quality in polymer extrusion processes. However, real time monitoring and control of viscosity is difficult to achieve. In this article, a novel “soft sensor” approach based on dynamic gray-box modeling is proposed. The soft sensor involves a nonlinear finite impulse response model with adaptable linear parameters for real-time prediction of the melt viscosity based on the process inputs; the model output is then used as an input of a model with a simple-fixed structure to predict the barrel pressure which can be measured online. Finally, the predicted pressure is compared to the measured value and the corresponding error is used as a feedback signal to correct the viscosity estimate. This novel feedback structure enables the online adaptability of the viscosity model in response to modeling errors and disturbances, hence producing a reliable viscosity estimate. The experimental results on different material/die/extruder confirm the effectiveness of the proposed “soft sensor” method based on dynamic gray-box modeling for real-time monitoring and control of polymer extrusion processes. POLYM. ENG. SCI., 2012. © 2012 Society of Plastics Engineers

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of hot-melt extrusion (HME) within the pharmaceutical industry is steadily increasing, due to its proven ability to efficiently manufacture novel products. The process has been utilized readily in the plastics industry for over a century and has been used to manufacture medical devices for several decades. The development of novel drugs with poor solubility and bioavailability brought the application of HME into the realm of drug-delivery systems. This has specifically been shown in the development of drug-delivery systems of both solid dosage forms and transdermal patches. HME involves the application of heat, pressure and agitation through an extrusion channel to mix materials together, and subsequently forcing them out through a die. Twin-screw extruders are most popular in solid dosage form development as it imparts both dispersive and distributive mixing. It blends materials while also imparting high shear to break-up particles and disperse them. HME extrusion has been shown to molecularly disperse poorly soluble drugs in a polymer carrier, increasing dissolution rates and bioavailability. The most common difficulty encountered in producing such dispersions is stabilization of amorphous drugs, which prevents them from recrystallization during storage. Pharmaceutical industrial suppliers, of both materials and equipment, have increased their development of equipment and chemicals for specific use with HME. Clearly, HME has been identified as an important and significant process to further enhance drug solubility and solid-dispersion production. © 2012 Future Science Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Anther extrusion has been widely discussed as a factor influencing fusarium head blight (FHB) resistance in wheat. This is despite a paucity of quantitative information on its importance, between cultivars, in contrast to that for heading date and plant height. We describe a method applicable to a plant breeding
situation at 10 days postanthesis, for assessing the distinct characteristics of anther retention (anthers held within the spikelet) and trapped anthers (partially
extruded and trapped between the lemma and palea of the wheat spikelet). FHB resistance was tested in field experiments in 2004 and 2005. In these experiments designed to resemble applications to a plant breeding selection scheme anther retention was significantly correlated with FHB in 2004 (r = 0.26; P < 0.05) and 2005 (r = 0.26; P < 0.05). A higher proportion of anthers retained relating, albeit weakly, with increased FHB susceptibility in European wheat.