873 resultados para Performance of the stock funds


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Health risk appraisal is a promising method for health promotion and prevention in older persons. The Health Risk Appraisal for the Elderly (HRA-E) developed in the U.S. has unique features but has not been tested outside the United States. METHODS: Based on the original HRA-E, we developed a scientifically updated and regionally adapted multilingual Health Risk Appraisal for Older Persons (HRA-O) instrument consisting of a self-administered questionnaire and software-generated feed-back reports. We evaluated the practicability and performance of the questionnaire in non-disabled community-dwelling older persons in London (U.K.) (N = 1090), Hamburg (Germany) (N = 804), and Solothurn (Switzerland) (N = 748) in a sub-sample of an international randomised controlled study. RESULTS: Over eighty percent of invited older persons returned the self-administered HRA-O questionnaire. Fair or poor self-perceived health status and older age were correlated with higher rates of non-return of the questionnaire. Older participants and those with lower educational levels reported more difficulty in completing the HRA-O questionnaire as compared to younger and higher educated persons. However, even among older participants and those with low educational level, more than 80% rated the questionnaire as easy to complete. Prevalence rates of risks for functional decline or problems were between 2% and 91% for the 19 HRA-O domains. Participants' intention to change health behaviour suggested that for some risk factors participants were in a pre-contemplation phase, having no short- or medium-term plans for change. Many participants perceived their health behaviour or preventative care uptake as optimal, despite indications of deficits according to the HRA-O based evaluation. CONCLUSION: The HRA-O questionnaire was highly accepted by a broad range of community-dwelling non-disabled persons. It identified a high number of risks and problems, and provided information on participants' intention to change health behaviour.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To analyse the performance of a new M. tuberculosis-specific interferon gamma (IFNgamma) assay in patients with chronic inflammatory diseases who receive immunosuppressive drugs, including tumour necrosis factor alpha (TNFalpha) inhibitors. METHODS: Cellular immune responses to the M. tuberculosis-specific antigens ESAT-6, CFP-10, TB7.7 were prospectively studied in 142 consecutive patients treated for inflammatory rheumatic conditions. Results were compared with tuberculin skin tests (TSTs). Association of both tests with risk factors for latent M. tuberculosis infection (LTBI) and BCG vaccination were determined and the influence of TNFalpha inhibitors, corticosteroids, and disease modifying antirheumatic drugs (DMARDs) on antigen-specific and mitogen-induced IFNgamma secretion was analysed. RESULTS: 126/142 (89%) patients received immunosuppressive therapy. The IFNgamma assay was more closely associated with the presence of risk factors (odds ratio (OR) = 23.8 (95% CI 5.14 to 110) vs OR = 2.77 (1.22 to 6.27), respectively; p = 0.009), but less associated with BCG vaccination than the TST (OR = 0.47 (95% CI 0.15 to 1.47) vs OR = 2.44 (0.74 to (8.01), respectively; p = 0.025). Agreement between the IFNgamma assay and TST results was low (kappa = 0.17; 95% CI 0.02 to 0.32). The odds for a positive IFNgamma assay strongly increased with increasing prognostic relevance of LTBI risk factors. Neither corticosteroids nor conventional DMARDs significantly affected IFNgamma responses, but the odds for a positive IFNgamma assay were decreased in patients treated with TNFalpha inhibitors (OR = 0.21 (95% CI 0.07 to 0.63), respectively; p = 0.006). CONCLUSIONS: These results demonstrate that the performance of the M. tuberculosis antigen-specific IFNgamma ELISA is better than the classic TST for detection of LTBI in patients receiving immunosuppressive therapy for treatment of systemic autoimmune disorders.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A diesel oxidation catalyst (DOC) with a catalyzed diesel particulate filter (CPF) is an effective exhaust aftertreatment device that reduces particulate emissions from diesel engines, and properly designed DOC-CPF systems provide passive regeneration of the filter by the oxidation of PM via thermal and NO2/temperature-assisted means under various vehicle duty cycles. However, controlling the backpressure on engines caused by the addition of the CPF to the exhaust system requires a good understanding of the filtration and oxidation processes taking place inside the filter as the deposition and oxidation of solid particulate matter (PM) change as functions of loading time. In order to understand the solid PM loading characteristics in the CPF, an experimental and modeling study was conducted using emissions data measured from the exhaust of a John Deere 6.8 liter, turbocharged and after-cooled engine with a low-pressure loop EGR system and a DOC-CPF system (or a CCRT® - Catalyzed Continuously Regenerating Trap®, as named by Johnson Matthey) in the exhaust system. A series of experiments were conducted to evaluate the performance of the DOC-only, CPF-only and DOC-CPF configurations at two engine speeds (2200 and 1650 rpm) and various loads on the engine ranging from 5 to 100% of maximum torque at both speeds. Pressure drop across the DOC and CPF, mass deposited in the CPF at the end of loading, upstream and downstream gaseous and particulate emissions, and particle size distributions were measured at different times during the experiments to characterize the pressure drop and filtration efficiency of the DOCCPF system as functions of loading time. Pressure drop characteristics measured experimentally across the DOC-CPF system showed a distinct deep-bed filtration region characterized by a non-linear pressure drop rise, followed by a transition region, and then by a cake-filtration region with steadily increasing pressure drop with loading time at engine load cases with CPF inlet temperatures less than 325 °C. At the engine load cases with CPF inlet temperatures greater than 360 °C, the deep-bed filtration region had a steep rise in pressure drop followed by a decrease in pressure drop (due to wall PM oxidation) in the cake filtration region. Filtration efficiencies observed during PM cake filtration were greater than 90% in all engine load cases. Two computer models, i.e., the MTU 1-D DOC model and the MTU 1-D 2-layer CPF model were developed and/or improved from existing models as part of this research and calibrated using the data obtained from these experiments. The 1-D DOC model employs a three-way catalytic reaction scheme for CO, HC and NO oxidation, and is used to predict CO, HC, NO and NO2 concentrations downstream of the DOC. Calibration results from the 1-D DOC model to experimental data at 2200 and 1650 rpm are presented. The 1-D 2-layer CPF model uses a ‘2-filters in series approach’ for filtration, PM deposition and oxidation in the PM cake and substrate wall via thermal (O2) and NO2/temperature-assisted mechanisms, and production of NO2 as the exhaust gas mixture passes through the CPF catalyst washcoat. Calibration results from the 1-D 2-layer CPF model to experimental data at 2200 rpm are presented. Comparisons of filtration and oxidation behavior of the CPF at sample load-cases in both configurations are also presented. The input parameters and selected results are also compared with a similar research work with an earlier version of the CCRT®, to compare and explain differences in the fundamental behavior of the CCRT® used in these two research studies. An analysis of the results from the calibrated CPF model suggests that pressure drop across the CPF depends mainly on PM loading and oxidation in the substrate wall, and also that the substrate wall initiates PM filtration and helps in forming a PM cake layer on the wall. After formation of the PM cake layer of about 1-2 µm on the wall, the PM cake becomes the primary filter and performs 98-99% of PM filtration. In all load cases, most of PM mass deposited was in the PM cake layer, and PM oxidation in the PM cake layer accounted for 95-99% of total PM mass oxidized during loading. Overall PM oxidation efficiency of the DOC-CPF device increased with increasing CPF inlet temperatures and NO2 flow rates, and was higher in the CCRT® configuration compared to the CPF-only configuration due to higher CPF inlet NO2 concentrations. Filtration efficiencies greater than 90% were observed within 90-100 minutes of loading time (starting with a clean filter) in all load cases, due to the fact that the PM cake on the substrate wall forms a very efficient filter. A good strategy for maintaining high filtration efficiency and low pressure drop of the device while performing active regeneration would be to clean the PM cake filter partially (i.e., by retaining a cake layer of 1-2 µm thickness on the substrate wall) and to completely oxidize the PM deposited in the substrate wall. The data presented support this strategy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The current article presents a novel physiological control algorithm for ventricular assist devices (VADs), which is inspired by the preload recruitable stroke work. This controller adapts the hydraulic power output of the VAD to the end-diastolic volume of the left ventricle. We tested this controller on a hybrid mock circulation where the left ventricular volume (LVV) is known, i.e., the problem of measuring the LVV is not addressed in the current article. Experiments were conducted to compare the response of the controller with the physiological and with the pathological circulation, with and without VAD support. A sensitivity analysis was performed to analyze the influence of the controller parameters and the influence of the quality of the LVV signal on the performance of the control algorithm. The results show that the controller induces a response similar to the physiological circulation and effectively prevents over- and underpumping, i.e., ventricular suction and backflow from the aorta to the left ventricle, respectively. The same results are obtained in the case of a disturbed LVV signal. The results presented in the current article motivate the development of a robust, long-term stable sensor to measure the LVV.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE Validity of the seventh edition of the American Joint Committee on Cancer/International Union Against Cancer (AJCC/UICC) staging systems for gastric cancer has been evaluated in several studies, mostly in Asian patient populations. Only few data are available on the prognostic implications of the new classification system on a Western population. Therefore, we investigated its prognostic ability based on a German patient cohort. PATIENTS AND METHODS Data from a single-center cohort of 1,767 consecutive patients surgically treated for gastric cancer were classified according to the seventh edition and were compared using the previous TNM/UICC classification. Kaplan-Meier analyses were performed for all TNM stages and UICC stages in a comparative manner. Additional survival receiver operating characteristic analyses and bootstrap-based goodness-of-fit comparisons via Bayesian information criterion (BIC) were performed to assess and compare prognostic performance of the competing classification systems. RESULTS We identified the UICC pT/pN stages according to the seventh edition of the AJCC/UICC guidelines as well as resection status, age, Lauren histotype, lymph-node ratio, and tumor grade as independent prognostic factors in gastric cancer, which is consistent with data from previous Asian studies. Overall survival rates according to the new edition were significantly different for each individual's pT, pN, and UICC stage. However, BIC analysis revealed that, owing to higher complexity, the new staging system might not significantly alter predictability for overall survival compared with the old system within the analyzed cohort from a statistical point of view. CONCLUSION The seventh edition of the AJCC/UICC classification was found to be valid with distinctive prognosis for each stage. However, the AJCC/UICC classification has become more complex without improving predictability for overall survival in a Western population. Therefore, simplification with better predictability of overall survival of patients with gastric cancer should be considered when revising the seventh edition.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: To detect attention deficit hyperactivity disorder (ADHD) in treatment seeking substance use disorders (SUD) patients, a valid screening instrument is needed. Objectives: To test the performance of the Adult ADHD Self-Report Scale V 1.1(ASRS) for adult ADHD in an international sample of treatment seeking SUD patients for DSM-IV-TR; for the proposed DSM-5 criteria; in different subpopulations, at intake and 1–2 weeks after intake; using different scoring algorithms; and different externalizing disorders as external criterion (including adult ADHD, bipolar disorder, antisocial and borderline personality disorder). Methods: In 1138 treatment seeking SUD subjects, ASRS performance was determined using diagnoses based on Conner's Adult ADHD Diagnostic Interview for DSM-IV (CAADID) as gold standard. Results: The prevalence of adult ADHD was 13.0% (95% CI: 11.0–15.0%). The overall positive predictive value (PPV) of the ASRS was 0.26 (95% CI: 0.22–0.30), the negative predictive value (NPV) was 0.97 (95% CI: 0.96–0.98). The sensitivity (0.84, 95% CI: 0.76–0.88) and specificity (0.66, 95% CI: 0.63–0.69) measured at admission were similar to the sensitivity (0.88, 95% CI: 0.83–0.93) and specificity (0.67, 95% CI: 0.64–0.70) measured 2 weeks after admission. Sensitivity was similar, but specificity was significantly better in patients with alcohol compared to (illicit) drugs as the primary substance of abuse (0.76 vs. 0.56). ASRS was not a good screener for externalizing disorders other than ADHD. Conclusions: The ASRS is a sensitive screener for identifying possible ADHD cases with very few missed cases among those screening negative in this population.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Chemotherapies of solid tumors commonly include 5-fluorouracil (5-FU). With standard doses of 5-FU, substantial inter-patient variability has been observed in exposure levels and treatment response. Recently, improved outcomes in colorectal cancer patients due to pharmacokinetically guided 5-FU dosing were reported. We aimed at establishing a rapid and sensitive method for monitoring 5-FU plasma levels in cancer patients in our routine clinical practice. METHODS: Performance of the Saladax My5-FU™ immunoassay was evaluated on the Roche Cobas® Integra 800 analyzer. Subsequently, 5-FU concentrations of 247 clinical plasma samples obtained with this assay were compared to the results obtained by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and other commonly used clinical analyzers (Olympus AU400, Roche Cobas c6000, and Thermo Fisher CDx90). RESULTS: The My-FU assay was successfully validated on the Cobas Integra 800 analyzer in terms of linearity, precision, accuracy, recovery, interference, sample carryover, and dilution integrity. Method comparison between the Cobas Integra 800 and LC-MS/MS revealed a proportional bias of 7% towards higher values measured with the My5-FU assay. However, when the Cobas Integra 800 was compared to three other clinical analyzers in addition to LC-MS/MS including 50 samples representing the typical clinical range of 5-FU plasma concentrations, only a small proportional bias (≤1.6%) and a constant bias below the limit of detection was observed. CONCLUSIONS: The My5-FU assay demonstrated robust and highly comparable performance on different analyzers. Therefore, the assay is suitable for monitoring 5-FU plasma levels in routine clinical practice and may contribute to improved efficacy and safety of commonly used 5-FU-based chemotherapies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Self-administered online surveys provide a higher level of privacy protection to respondents than surveys administered by an interviewer. Yet, studies show that asking sensitive questions is problematic also in self-administered mode. Because respondents might not be willing to reveal the truth and provide answers that are subject to social desirability bias, the validity of prevalence estimates of sensitive behaviors gained via online surveys can be challenged. A well-known method to combat these problems is the Randomized Response Technique (RRT). However, convincing evidence that the RRT provides more valid estimates than direct questioning in online mode is still lacking. Moreover, an alternative approach called the Crosswise Model (CM) has recently been suggested to overcome some of the deficiencies of the RRT. In the context of an online survey on plagiarism and cheating on exams among students of two Swiss universities (N = 6,494), we tested different implementations of the RRT and the CM and compared them to direct questioning using a randomized experimental design. Results reveal a poor performance of the RRT, which failed to elicit higher prevalence estimates than direct questioning. Using the CM however, significantly higher prevalence estimates were obtained making it a promising new alternative to the conventional RRT.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE The DRAGON score predicts functional outcome in the hyperacute phase of intravenous thrombolysis treatment of ischemic stroke patients. We aimed to validate the score in a large multicenter cohort in anterior and posterior circulation. METHODS Prospectively collected data of consecutive ischemic stroke patients who received intravenous thrombolysis in 12 stroke centers were merged (n=5471). We excluded patients lacking data necessary to calculate the score and patients with missing 3-month modified Rankin scale scores. The final cohort comprised 4519 eligible patients. We assessed the performance of the DRAGON score with area under the receiver operating characteristic curve in the whole cohort for both good (modified Rankin scale score, 0-2) and miserable (modified Rankin scale score, 5-6) outcomes. RESULTS Area under the receiver operating characteristic curve was 0.84 (0.82-0.85) for miserable outcome and 0.82 (0.80-0.83) for good outcome. Proportions of patients with good outcome were 96%, 93%, 78%, and 0% for 0 to 1, 2, 3, and 8 to 10 score points, respectively. Proportions of patients with miserable outcome were 0%, 2%, 4%, 89%, and 97% for 0 to 1, 2, 3, 8, and 9 to 10 points, respectively. When tested separately for anterior and posterior circulation, there was no difference in performance (P=0.55); areas under the receiver operating characteristic curve were 0.84 (0.83-0.86) and 0.82 (0.78-0.87), respectively. No sex-related difference in performance was observed (P=0.25). CONCLUSIONS The DRAGON score showed very good performance in the large merged cohort in both anterior and posterior circulation strokes. The DRAGON score provides rapid estimation of patient prognosis and supports clinical decision-making in the hyperacute phase of stroke care (eg, when invasive add-on strategies are considered).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND To investigate the performance of the MI Sxscore in a multicentre randomised trial of patients undergoing primary percutaneous coronary intervention (PPCI). METHODS AND RESULTS The MI Sxscore was prospectively determined among 1132 STEMI patients enrolled into the COMFORTABLE AMI trial, which randomised patients to treatment with bare-metal (BMS) or biolimus-eluting (BES) stents. Patient- (death, myocardial infarction, any revascularisation) and device-oriented (cardiac death, target-vessel MI, target lesion revascularisation) major adverse cardiac events (MACEs) were compared across MI Sxscore tertiles and according to stent type. The median MI SXscore was 14 (IQR: 9-21). Patients were divided into tertiles of Sxscorelow (≤10), Sxscoreintermediate (11-18) and Sxscorehigh (≥19). At 1year, patient-oriented MACE occurred in 15% of the Sxscorehigh, 9% of the Sxscoreintermediate and 5% of the Sxscorelow tertiles (p<0.001), whereas device-oriented MACE occurred in 8% of the Sxscorehigh, 6% of the Sxscoreintermediate and 4% of the Sxscorelow tertiles (p=0.03). Addition of the MI Sxscore to the TIMI risk score improved prediction of patient- (c-statistic value increase from 0.63 to 0.69) and device-oriented MACEs (c-statistic value increase from 0.65 to 0.70). Differences in the risk for device-oriented MACE between BMS and BES were evident among Sxscorehigh (13% vs. 4% HR 0.33 (0.15-0.74), p=0.007 rather than those in Sxscorelow: 4% vs. 3% HR 0.68 (0.24-1.97), p=0.48) tertiles. CONCLUSIONS The MI Sxscore allows risk stratification of patient- and device-oriented MACEs among patients undergoing PPCI. The addition of the MI Sxscore to the TIMI risk score is of incremental prognostic value among patients undergoing PPCI for treatment of STEMI.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES This study sought to describe the frequency and clinical impact of acute scaffold disruption and late strut discontinuity of the second-generation Absorb bioresorbable polymeric vascular scaffolds (Absorb BVS, Abbott Vascular, Santa Clara, California) in the ABSORB (A Clinical Evaluation of the Bioabsorbable Everolimus Eluting Coronary Stent System in the Treatment of Patients With De Novo Native Coronary Artery Lesions) cohort B study by optical coherence tomography (OCT) post-procedure and at 6, 12, 24, and 36 months. BACKGROUND Fully bioresorbable scaffolds are a novel approach to treatment for coronary narrowing that provides transient vessel support with drug delivery capability without the long-term limitations of metallic drug-eluting stents. However, a potential drawback of the bioresorbable scaffold is the potential for disruption of the strut network when overexpanded. Conversely, the structural discontinuity of the polymeric struts at a late stage is a biologically programmed fate of the scaffold during the course of bioresorption. METHODS The ABSORB cohort B trial is a multicenter single-arm trial assessing the safety and performance of the Absorb BVS in the treatment of 101 patients with de novo native coronary artery lesions. The current analysis included 51 patients with 143 OCT pullbacks who underwent OCT at baseline and follow-up. The presence of acute disruption or late discontinuities was diagnosed by the presence on OCT of stacked, overhung struts or isolated intraluminal struts disconnected from the expected circularity of the device. RESULTS Of 51 patients with OCT imaging post-procedure, acute scaffold disruption was observed in 2 patients (3.9%), which could be related to overexpansion of the scaffold at the time of implantation. One patient had a target lesion revascularization that was presumably related to the disruption. Of 49 patients without acute disruption, late discontinuities were observed in 21 patients. There were no major adverse cardiac events associated with this finding except for 1 patient who had a non-ischemia-driven target lesion revascularization. CONCLUSIONS Acute scaffold disruption is a rare iatrogenic phenomenon that has been anecdotally associated with anginal symptoms, whereas late strut discontinuity is observed in approximately 40% of patients and could be viewed as a serendipitous OCT finding of a normal bioresorption process without clinical implications. (ABSORB Clinical Investigation, Cohort B [ABSORB B]; NCT00856856).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND CONTEXT The nerve root sedimentation sign in transverse magnetic resonance imaging has been shown to discriminate well between selected patients with and without lumbar spinal stenosis (LSS), but the performance of this new test, when used in a broader patient population, is not yet known. PURPOSE To evaluate the clinical performance of the nerve root sedimentation sign in detecting central LSS above L5 and to determine its potential significance for treatment decisions. STUDY DESIGN Retrospective cohort study. PATIENT SAMPLE One hundred eighteen consecutive patients with suspected LSS (52% women, median age 62 years) with a median follow-up of 24 months. OUTCOME MEASURES Oswestry disability index (ODI) and back and leg pain relief. METHODS We performed a clinical test validation study to assess the clinical performance of the sign by measuring its association with health outcomes. Subjects were patients referred to our orthopedic spine unit from 2004 to 2007 before the sign had been described. Based on clinical and radiological diagnostics, patients had been treated with decompression surgery or nonsurgical treatment. Changes in the ODI and pain from baseline to 24-month follow-up were compared between sedimentation sign positives and negatives in both treatment groups. RESULTS Sixty-nine patients underwent surgery. Average baseline ODI in the surgical group was 54.7%, and the sign was positive in 39 patients (mean ODI improvement 29.0 points) and negative in 30 (ODI improvement 28.4), with no statistically significant difference in ODI and pain improvement between groups. In the 49 patients of the nonsurgical group, mean baseline ODI was 42.4%; the sign was positive in 18 (ODI improvement 0.6) and negative in 31 (ODI improvement 17.7). A positive sign was associated with a smaller ODI and back pain improvement than negative signs (both p<.01 on t test). CONCLUSIONS In patients commonly treated with decompression surgery, the sedimentation sign does not appear to predict surgical outcome. In nonsurgically treated patients, a positive sign is associated with more limited improvement. In these cases, surgery might be effective, but this needs investigation in prospective randomized trials (Australian New Zealand Clinical Trial Registry, number ACTRN12610000567022).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a study of the performance of the muon reconstruction in the analysis of proton–proton collisions at √s = 7TeV at theLHC, recorded by the ATLAS detector in 2010. This performance is described in terms of reconstruction and isolation efficiencies and momentum resolutions for different classes of reconstructed muons. The results are obtained from an analysis of J/ψ meson and Z boson decays to dimuons, reconstructed from a data sample corresponding to an integrated luminosity of 40 pb−1. The measured performance is compared to Monte Carlo predictions and deviations from the predicted performance are discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND The distribution of the enzymopathy glucose-6-phosphate dehydrogenase (G6PD) deficiency is linked to areas of high malaria endemicity due to its association with protection from disease. G6PD deficiency is also identified as the cause of severe haemolysis following administration of the anti-malarial drug primaquine and further use of this drug will likely require identification of G6PD deficiency on a population level. Current conventional methods for G6PD screening have various disadvantages for field use. METHODS The WST8/1-methoxy PMS method, recently adapted for field use, was validated using a gold standard enzymatic assay (R&D Diagnostics Ltd ®) in a study involving 235 children under five years of age, who were recruited by random selection from a cohort study in Tororo, Uganda. Blood spots were collected by finger-prick onto filter paper at routine visits, and G6PD activity was determined by both tests. Performance of the WST8/1-methoxy PMS test under various temperature, light, and storage conditions was evaluated. RESULTS The WST8/1-methoxy PMS assay was found to have 72% sensitivity and 98% specificity when compared to the commercial enzymatic assay and the AUC was 0.904, suggesting good agreement. Misclassifications were at borderline values of G6PD activity between mild and normal levels, or related to outlier haemoglobin values (<8.0 gHb/dl or >14 gHb/dl) associated with ongoing anaemia or recent haemolytic crises. Although severe G6PD deficiency was not found in the area, the test enabled identification of low G6PD activity. The assay was found to be highly robust for field use; showing less light sensitivity, good performance over a wide temperature range, and good capacity for medium-to-long term storage. CONCLUSIONS The WST8/1-methoxy PMS assay was comparable to the currently used standard enzymatic test, and offers advantages in terms of cost, storage, portability and use in resource-limited settings. Such features make this test a potential key tool for deployment in the field for point of care assessment prior to primaquine administration in malaria-endemic areas. As with other G6PD tests, outlier haemoglobin levels may confound G6PD level estimation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND We observed a case of conductor externalization in a Biotronik Linox lead. OBJECTIVE To investigate lead performance of the Linox and identical Sorin Vigila lead and prevalence of conductor externalization. METHODS We compared lead performance of all Linox and Vigila leads implanted at our center (BL group; n=93) with all Boston Scientific Endotak Reliance leads (ER group; n=190) and Medtronic Sprint Quattro leads (SQ group; n=202) implanted during the same period. We screened all BL group patients for conductor externalization. RESULTS We identified 8 cases of lead failures in the BL group (index case of conductor externalization; 6 cases of non-physiological high rate sensing; one case of high voltage conductor fracture). Prospective, fluoroscopic screening of 98% of all active BL group cases revealed one additional case of conductor externalization. Median follow-up was 41, 27 and 29 months for the BL group, ER group and SQ group, respectively, lead survival 94.9%, 99.2% and 100% at 3 years, and 88%, 97.5% and 100% at 5 years (p=0.038 for BL group vs. ER group, and p=0.007 for BL group vs. SQ group by the log-rank test). Younger age at implant was an independent predictor for lead failure in the BL group (adjusted HR 0.85 [95% confidence interval 0.77-0.94]; p=0.001). CONCLUSION At our center, survival of the Linox lead is 88% at five years and significantly worse than its comparators. Conductor externalization is present in a minority of failed Linox leads. Younger age at implant is an independent predictor of Linox lead failure.