898 resultados para Metal analysis
Resumo:
This paper provides a theoretical assessment of the safety considerations encountered in the simultaneous use of transcranial magnetic stimulation (TMS) and neurological interventions involving implanted metallic electrodes, such as electrocorticography. Metal implants are subject to magnetic forces due to fast alternating magnetic fields produced by the TMS coil. The question of whether the mechanical movement of the implants leads to irreversible damage of brain tissue is addressed by an electromagnetic simulation which quantifies the magnitude of imposed magnetic forces. The assessment is followed by a careful mechanical analysis determining the maximum tolerable force which does not cause irreversible tissue damage. Results of this investigation provide useful information on the range of TMS stimulator output powers which can be safely used in patients having metallic implants. It is shown that conventional TMS applications can be considered safe when applied on patients with typical electrode implants as the induced stress in the brain tissue remains well below the limit of tissue damage.
Resumo:
OBJECTIVES: The purpose of this research was to determine the relative safety and efficacy of multiple (> or =2) overlapping Cypher sirolimus-eluting stents (SES) (Johnson ; Johnson, New Brunswick, New Jersey). BACKGROUND: Overlapping coronary stents are common. The periprocedural and late clinical and angiographic consequences of overlapped coronary stents are not clearly defined, particularly for drug-eluting stents. METHODS: All patients enrolled into five clinical trials of the SES were analyzed. Three of these trials were prospective randomized comparisons of the SES to the bare-metal stent (BMS), and two were prospective non-randomized trials of SES-treated patients with historical controls. All clinical and angiographic outcomes in overlap-stent-treated patients were compared by stent type and with single-stent-treated patients for the same stent device. RESULTS: In all, 575 patients with stent overlap (337 SES, 238 BMS) and 1,162 patients with single stents (697 SES, 465 BMS) were analyzed. Stent overlap was associated with a greater late lumen loss in stent and more frequent angiographic restenosis regardless of stent type. Among overlap-stent-treated patients, the SES provided similar magnitude of restenosis benefit as observed for single-stent-treated patients. Overlapped SES was not associated with an increase in myocardial infarction. CONCLUSIONS: The strategy of SES overlap, when required, is both safe and efficacious in reducing restenosis with no increase in the incidence of myocardial infarction or major adverse cardiovascular events, when compared with a bare metal coronary stent prosthesis.
Resumo:
STATEMENT OF PROBLEM: AuTi alloys with 1.6% to 1.7% (wt%) Ti provide sufficient bond strength to veneering ceramics, but the strength of entire metal-ceramic restorations fabricated from these alloys is not known. However, this information is important to assess the clinical performance of such materials. PURPOSE: This in vitro study evaluated the fracture strength and thermal shock resistance of metal-ceramic crowns with AuTi frameworks produced by milling or casting. MATERIAL AND METHODS: Frameworks of the alloy Au-1.7Ti-0.1Ir (wt%) (Esteticor Vision) were produced by milling or casting (test groups). A high-gold alloy (Esteticor Special) was used as the control. The frameworks were veneered with ceramic (VMK 95). Specimens (n=7) were loaded until fracture. Loads at failure (N) were recorded and the mean values statistically evaluated using 1-way analysis of variance and a post hoc Dunnett test (alpha=.05). To assess the crazing resistance of the veneering ceramic, 6 additional crowns of each group were subjected to a thermal shock test. Fractured surfaces were documented by scanning electron microscopy. Coefficients of thermal expansion of the materials used were measured (n=2) to assess the thermal compatibility between alloys and ceramic. RESULTS: The mean fracture strength of the crowns with machined AuTi frameworks (1294 +/- 236 N) was significantly lower (P=.012) than that of the cast AuTi frameworks (1680 +/- 150 N), but statistically not different than the high-gold alloy (1449 +/- 159 N). Bonding failure to the AuTi alloy predominantly occurred at the alloy-oxide interface. For the high-gold alloy, more ceramic residues were observed. In the thermal shock test, crowns with milled AuTi frameworks showed significantly higher thermal shock resistance compared to the other groups. The coefficients of thermal expansion (Esteticor Vision cast: 14.5 microm/m.K; Esteticor Vision milled: 14.3 microm/m.K; Esteticor Special cast: 13.7 microm/m.K) did not correlate with the results of the thermal shock test. CONCLUSION: The in vitro fracture strength of crowns with milled AuTi frameworks is lower than that obtained with cast AuTi frameworks, but comparable to those crowns produced with a high-gold alloy.
Resumo:
BACKGROUND: Based on a subgroup analysis of 18-month BAsel Stent Kosten Effektivitäts Trial (BASKET) outcome data, we hypothesized that very late (> 12 months) stent thrombosis occurs predominantly after drug-eluting stent implantation in large native coronary vessel stenting. METHODS: To prove or refute this hypothesis, we set up an 11-center 4-country prospective trial of 2260 consecutive patients treated with > or = 3.0-mm stents only, randomized to receive Cypher (Johnson ; Johnson, Miami Lakes, FL), Vision (Abbott Vascular, Abbott Laboratories, IL), or Xience stents (Abbott Vascular). Only patients with left main or bypass graft disease, in-stent restenosis or stent thrombosis, in need of nonheart surgery, at increased bleeding risk, without compliance/consent are excluded. All patients are treated with dual antiplatelet therapy for 12 months. The primary end point will be cardiac death/nonfatal myocardial infarction after 24 months with further follow-up up to 5 years. RESULTS: By June 12, 229 patients (10% of the planned total) were included with a baseline risk similar to that of the same subgroup of BASKET (n = 588). CONCLUSIONS: This study will answer several important questions of contemporary stent use in patients with large native vessel stenting. The 2-year death/myocardial infarction-as well as target vessel revascularization-and bleeding rates in these patients with a first- versus second-generation drug-eluting stent should demonstrate the benefit or harm of these stents compared to cobalt-chromium bare-metal stents in this relevant, low-risk group of everyday patients. In addition, a comparison with similar BASKET patients will allow to estimate the impact of 12- versus 6-month dual antiplatelet therapy on these outcomes.
Resumo:
In this study, we isolated eight copper-resistant bacteria from Torch Lake sediment contaminated by copper mine tailings (stamp sand). Sequence analysis of gyrB and rpoD genes revealed that these organisms are closer to various Pseudomonas species. These eight bacterial isolates were also resistant to zinc, cesium, lead, arsenate and mercury. Further characterization showed that all the strains produced plant growth promoting indole-3-acetic acid (IAA), iron chelating siderophore and solubilized mineral phosphate and metals. The effect of bacterial inoculation on plant growth and copper uptake by maize (Zea mays) and sunflower (Helianthus annuus) was investigated using one of the isolates (Pseudomonas sp. TLC 6-6.5-4) with higher IAA production and phosphate and metal soubilization, which resulted in a significant increase in copper accumulation in maize and sunflower, and an increase in the total biomass of maize. Genes involved in copper resistance of Pseudomonas sp. TLC 6-6.5-4 was analyzed by transposon mutational analysis. Two copper sensitive mutants with significant reduction in copper resistance were identified: CSM1, a mutant disrupted in trp A gene (tryptophan synthase alpha subunit); CSM2, a mutant disrupted in clpA gene (ATP-dependent Clp protease). Proteomic and metabolomic analysis were performed to identify biochemical and molecular mechanisms involved in copper resistance using CSM2 due to its lower minimum inhibitory concentration compared with CSM1 and the wild type. The effect of different bacterial inoculation methods on plant growth, copper uptake and soil enzyme activities was investigated. Four different delivery methods were used including soil inoculation (before or after plant emergence), seed coating and root dipping. Soil inoculation before sowing seeds and coating seeds with PGPB led to better growth of maize, higher copper uptake and an increase in soil invertase and dehydrogenase activities. Proteomic and metabolomic analyses were performed to investigate the effect of bacterial inoculation on maize grown in normal soil and stamp sand. Our results revealed that bacterial inoculation led to environment-dependent effects on maize proteome and metabolome.
Resumo:
As the demand for miniature products and components continues to increase, the need for manufacturing processes to provide these products and components has also increased. To meet this need, successful macroscale processes are being scaled down and applied at the microscale. Unfortunately, many challenges have been experienced when directly scaling down macro processes. Initially, frictional effects were believed to be the largest challenge encountered. However, in recent studies it has been found that the greatest challenge encountered has been with size effects. Size effect is a broad term that largely refers to the thickness of the material being formed and how this thickness directly affects the product dimensions and manufacturability. At the microscale, the thickness becomes critical due to the reduced number of grains. When surface contact between the forming tools and the material blanks occur at the macroscale, there is enough material (hundreds of layers of material grains) across the blank thickness to compensate for material flow and the effect of grain orientation. At the microscale, there may be under 10 grains across the blank thickness. With a decreased amount of grains across the thickness, the influence of the grain size, shape and orientation is significant. Any material defects (either natural occurring or ones that occur as a result of the material preparation) have a significant role in altering the forming potential. To date, various micro metal forming and micro materials testing equipment setups have been constructed at the Michigan Tech lab. Initially, the research focus was to create a micro deep drawing setup to potentially build micro sensor encapsulation housings. The research focus shifted to micro metal materials testing equipment setups. These include the construction and testing of the following setups: a micro mechanical bulge test, a micro sheet tension test (testing micro tensile bars), a micro strain analysis (with the use of optical lithography and chemical etching) and a micro sheet hydroforming bulge test. Recently, the focus has shifted to study a micro tube hydroforming process. The intent is to target fuel cells, medical, and sensor encapsulation applications. While the tube hydroforming process is widely understood at the macroscale, the microscale process also offers some significant challenges in terms of size effects. Current work is being conducted in applying direct current to enhance micro tube hydroforming formability. Initially, adding direct current to various metal forming operations has shown some phenomenal results. The focus of current research is to determine the validity of this process.
Resumo:
The B-box motif is the defining feature of the TRIM family of proteins, characterized by a RING finger-B-box-coiled coil tripartite fold. We have elucidated the crystal structure of B-box 2 (B2) from MuRF1, a TRIM protein that supports a wide variety of protein interactions in the sarcomere and regulates the trophic state of striated muscle tissue. MuRF1 B2 coordinates two zinc ions through a cross-brace alpha/beta-topology typical of members of the RING finger superfamily. However, it self-associates into dimers with high affinity. The dimerization pattern is mediated by the helical component of this fold and is unique among RING-like folds. This B2 reveals a long shallow groove that encircles the C-terminal metal binding site ZnII and appears as the defining protein-protein interaction feature of this domain. A cluster of conserved hydrophobic residues in this groove and, in particular, a highly conserved aromatic residue (Y133 in MuRF1 B2) is likely to be central to this role. We expect these findings to aid the future exploration of the cellular function and therapeutic potential of MuRF1.
Resumo:
BACKGROUND: Intravascular ultrasound of drug-eluting stent (DES) thrombosis (ST) reveals a high incidence of incomplete stent apposition (ISA) and vessel remodeling. Autopsy specimens of DES ST show delayed healing and hypersensitivity reactions. The present study sought to correlate histopathology of thrombus aspirates with intravascular ultrasound findings in patients with very late DES ST. METHODS AND RESULTS: The study population consisted of 54 patients (28 patients with very late DES ST and 26 controls). Of 28 patients with very late DES ST, 10 patients (1020+/-283 days after implantation) with 11 ST segments (5 sirolimus-eluting stents, 5 paclitaxel-eluting stents, 1 zotarolimus-eluting stent) underwent both thrombus aspiration and intravascular ultrasound investigation. ISA was present in 73% of cases with an ISA cross-sectional area of 6.2+/-2.4 mm(2) and evidence of vessel remodeling (index, 1.6+/-0.3). Histopathological analysis showed pieces of fresh thrombus with inflammatory cell infiltrates (DES, 263+/-149 white blood cells per high-power field) and eosinophils (DES, 20+/-24 eosinophils per high-power field; sirolimus-eluting stents, 34+/-28; paclitaxel-eluting stents, 6+/-6; P for sirolimus-eluting stents versus paclitaxel-eluting stents=0.09). The mean number of eosinophils per high-power field was higher in specimens from very late DES ST (20+/-24) than in those from spontaneous acute myocardial infarction (7+/-10), early bare-metal stent ST (1+/-1), early DES ST (1+/-2), and late bare-metal stent ST (2+/-3; P from ANOVA=0.038). Eosinophil count correlated with ISA cross-sectional area, with an average increase of 5.4 eosinophils per high-power field per 1-mm(2) increase in ISA cross-sectional area. CONCLUSIONS: Very late DES thrombosis is associated with histopathological signs of inflammation and intravascular ultrasound evidence of vessel remodeling. Compared with other causes of myocardial infarction, eosinophilic infiltrates are more common in thrombi harvested from very late DES thrombosis, particularly in sirolimus-eluting stents, and correlate with the extent of stent malapposition.
Resumo:
OBJECTIVES: The objective of this systematic review was to assess the 5-year survival rates and incidences of complications associated with ceramic abutments and to compare them with those of metal abutments. METHODS: An electronic Medline search complemented by manual searching was conducted to identify randomized-controlled clinical trials, and prospective and retrospective studies providing information on ceramic and metal abutments with a mean follow-up time of at least 3 years. Patients had to have been examined clinically at the follow-up visit. Assessment of the identified studies and data abstraction was performed independently by three reviewers. Failure rates were analyzed using standard and random-effects Poisson regression models to obtain summary estimates of 5-year survival proportions. RESULTS: Twenty-nine clinical and 22 laboratory studies were selected from an initial yield of 7136 titles and data were extracted. The estimated 5-year survival rate of ceramic abutments was 99.1% [95% confidence interval (CI): 93.8-99.9%] and 97.4% (95% CI: 96-98.3%) for metal abutments. The estimated cumulative incidence of technical complications after 5 years was 6.9% (95% CI: 3.5-13.4%) for ceramic abutments and 15.9% (95% CI: 11.6-21.5%) for metal abutments. Abutment screw loosening was the most frequent technical problem, occurring at an estimated cumulative incidence after 5 years of 5.1% (95% CI: 3.3-7.7%). All-ceramic crowns supported by ceramic abutments exhibited similar annual fracture rates as metal-ceramic crowns supported by metal abutments. The cumulative incidence of biological complications after 5 years was estimated at 5.2% (95% CI: 0.4-52%) for ceramic and 7.7% (95% CI: 4.7-12.5%) for metal abutments. Esthetic complications tended to be more frequent at metal abutments. A meta-analysis of the laboratory data was impossible due to the non-standardized test methods of the studies included. CONCLUSION: The 5-year survival rates estimated from annual failure rates appeared to be similar for ceramic and metal abutments. The information included in this review did not provide evidence for differences of the technical and biological outcomes of ceramic and metal abutments. However, the information for ceramic abutments was limited in the number of studies and abutments analyzed as well as the accrued follow-up time. Standardized methods for the analysis of abutment strength are needed.
Resumo:
A general, two-step highly efficient synthesis of 1,2-diaryl-, 1,2,3-triaryl- and 1,2,3,4-tetraarylbenzenes from simple stitching of alpha-oxo-ketene-S,S-acetals and active methylene compounds via a ‘lactone intermediate’ is described. This procedure offers easy access to highly functionalized arylated-benzenes containing sterically demanding groups in good to excellent yields. The novelty of the procedure lies in the fabrication of aromatic compounds with desired conformational flexibility along the molecular axis in a transition metal-free environment through easily accessible precursors. The crystal analysis of these arylated-benzene scaffolds showed that the peripheral aryl rings are arranged in propeller-like fashion with respect to the central benzene rings. Examination of the crystal packing in the structure of a 1,2,3,4-tetraarylbenzene 12c revealed a “N…pi interaction” between molecules related by a two-fold screw axis running in a direction. It is interesting that the repeat of the array of N…pi interaction around the axis of the 1,2,3,4-tetraarylbenzene 12c enforces the molecules in a helical pattern.
Resumo:
BACKGROUND The safety and efficacy of drug-eluting stents (DES) in the treatment of coronary artery disease have been assessed in several randomised trials. However, none of these trials were powered to assess the safety and efficacy of DES in women because only a small proportion of recruited participants were women. We therefore investigated the safety and efficacy of DES in female patients during long-term follow-up. METHODS We pooled patient-level data for female participants from 26 randomised trials of DES and analysed outcomes according to stent type (bare-metal stents, early-generation DES, and newer-generation DES). The primary safety endpoint was a composite of death or myocardial infarction. The secondary safety endpoint was definite or probable stent thrombosis. The primary efficacy endpoint was target-lesion revascularisation. Analysis was by intention to treat. FINDINGS Of 43,904 patients recruited in 26 trials of DES, 11,557 (26·3%) were women (mean age 67·1 years [SD 10·6]). 1108 (9·6%) women received bare-metal stents, 4171 (36·1%) early-generation DES, and 6278 (54·3%) newer-generation DES. At 3 years, estimated cumulative incidence of the composite of death or myocardial infarction occurred in 132 (12·8%) women in the bare-metal stent group, 421 (10·9%) in the early-generation DES group, and 496 (9·2%) in the newer-generation DES group (p=0·001). Definite or probable stent thrombosis occurred in 13 (1·3%), 79 (2·1%), and 66 (1·1%) women in the bare-metal stent, early-generation DES, and newer-generation DES groups, respectively (p=0·01). The use of DES was associated with a significant reduction in the 3 year rates of target-lesion revascularisation (197 [18·6%] women in the bare-metal stent group, 294 [7·8%] in the early-generation DES group, and 330 [6·3%] in the newer-generation DES group, p<0·0001). Results did not change after adjustment for baseline characteristics in the multivariable analysis. INTERPRETATION The use of DES in women is more effective and safe than is use of bare-metal stents during long-term follow-up. Newer-generation DES are associated with an improved safety profile compared with early-generation DES, and should therefore be thought of as the standard of care for percutaneous coronary revascularisation in women. FUNDING Women in Innovation Initiative of the Society of Cardiovascular Angiography and Interventions.
Resumo:
OBJECTIVES This study sought to assess the clinical safety and effectiveness of the Resolute zotarolimus-eluting stent (R-ZES) in patients with in-stent restenosis (ISR) from 2 large trials. BACKGROUND ISR treatment is associated with higher rates of subsequent cardiac events compared with treatment of de novo lesions. Although drug-eluting stents (DES) are an option, second-generation DES are largely untested in the treatment of ISR. METHODS A total of 3,489 patients were pooled from the RAC (RESOLUTE All Comers) trial and the RESOLUTE International (RINT) registry. Two-year clinical endpoints included clinically driven target lesion revascularization (TLR), target lesion failure (TLF), cardiac death (CD), target vessel myocardial infarction (TVMI), combined CD or TVMI (CD/TVMI), and Academic Research Consortium definite and probable stent thrombosis (ST). RESULTS Overall, 281 patients (8.1%) received an R-ZES for ISR. Two-year TLR and TLF rates were significantly higher in ISR patients than in non-ISR patients (TLR: 12.7% vs. 4.3%, p = 0.003; TLF: 17.4% vs. 9.4%, p = 0.007); however, the CD/TVMI rate was not (6.9% vs. 6.1%, p = 0.711). Seven ISR patients had ST. Two-year outcomes by ISR stent type were similar: bare-metal stent (BMS)-ISR TLR was 12.5% and TLF was 17.2%; DES-ISR TLR was 13.0% and TLF was 18.8%. CD/TVMI was 7.3% and 7.2% for BMS-ISR and DES-ISR, respectively. CONCLUSIONS Using R-ZES to treat ISR appears equally safe in BMS-ISR and DES-ISR, with CD/TVMI rates comparable to 2-year outcomes in other clinical trials. Although revascularization rates are still higher in ISR lesions, the R-ZES offers an effective alternative for treatment of BMS-ISR and DES-ISR. (Randomized, Two-Arm, Non-inferiority Study Comparing Endeavor-Resolute Stent With Abbot Xience-V Stent [RESOLUTE-AC]; NCT00617084; and RESOLUTE International Registry: Evaluation of the Resolute Zotarolimus-Eluting Stent System in a 'Real-World' Patient Population [RINT]; NCT00752128).
Resumo:
The platform-independent software package consisting of the oligonucleotide mass assembler (OMA) and the oligonucleotide peak analyzer (OPA) was created to support the analysis of oligonucleotide mass spectra. It calculates all theoretically possible fragments of a given input sequence and annotates it to an experimental spectrum, thus, saving a large amount of manual processing time. The software performs analysis of precursor and product ion spectra of oligonucleotides and their analogues comprising user-defined modifications of the backbone, the nucleobases, or the sugar moiety, as well as adducts with metal ions or drugs. The ability to expand the library of building blocks and to implement individual structural variations makes it extremely useful for supporting the analysis of therapeutically active compounds. The functionality of the software tool is demonstrated on the examples of a platinated doublestranded oligonucleotide and a modified RNA sequence. Experiments also reveal the unique dissociation behavior of platinated higher-order DNA structures.
Resumo:
BACKGROUND We aimed to describe the effects of ticagrelor versus clopidogrel on stent thrombosis in the Platelet Inhibition and Patient Outcomes (PLATO) trial. METHODS AND RESULTS Of 18 624 patients hospitalized for acute coronary syndromes, 11 289 (61%) had at least 1 intracoronary stent. Ticagrelor reduced stent thrombosis compared with clopidogrel across all definitions: definite, 1.37% (n=71) versus 1.93% (n=105; hazard ratio [HR], 0.67; 95% confidence interval [CI], 0.50-0.90; P=0.0091); definite or probable, 2.21% (n=118) versus 2.87% (n=157; HR, 0.75; 95% CI, 0.59-0.95; P=0.017); and definite, probable, and possible, 2.94% (n=154) versus 3.77 (n=201; HR, 0.77; 95% CI, 0.62-0.95). The reduction in definite stent thrombosis was consistent regardless of acute coronary syndrome type, presence of diabetes mellitus, stent type (drug-eluting or bare metal stent), CYP2C19 genetic status, loading dose of aspirin, dose of clopidogrel before randomization, and use of glycoprotein IIb/IIIa inhibitors at randomization. The reduction in stent thrombosis with ticagrelor was numerically greater for late (>30 days; HR, 0.48; 95% CI, 0.24-0.96) and subacute (4 hours-30 days; HR, 0.60; 95% CI, 0.39-0.93) compared with acute (<24 hours; HR, 0.94; 95% CI, 0.43-2.05) stent thrombosis or for patients compliant to therapy (ie, taking blinded study treatment ≥80% of the time) compared with less compliant patients. Randomization to ticagrelor was a strong independent inverse predictor of definite stent thrombosis (HR, 0.65; 95% CI, 0.48-0.88). CONCLUSION Ticagrelor compared with clopidogrel reduces the incidence of stent thrombosis in patients with acute coronary syndromes, with consistent benefit across a broad range of patient, stent, and treatment characteristics.
Resumo:
Samples obtained from different locations within the prototype liquid metal spallation target MEGAPIE irradiated in 2006 at PSI were analysed using γ-spectrometry. A variety of radionuclides formed by reaction of the target material, lead–bismuth eutectic (LBE), with the proton beam and secondary particles were identified. While nuclides representing the target material itself (207Bi) and nuclides of noble metals were found in LBE samples throughout the target, nuclides of electropositive metals were found to be quantitatively deposited on free surfaces and material interfaces within the target system. This behaviour is analysed in more detail based on results obtained for three nuclides representing groups of elements with distinct chemical behaviour, namely 207Bi, 194Hg/Au and 173Lu. Quantitative analysis results are given and compared with predictions obtained using nuclear physics calculations for those nuclides showing rather homogeneous distribution within the target. Possible reasons for the separation of radionuclides from the liquid metal and their deposition on surfaces are given, and consequences arising for nuclear facilities utilizing liquid metals are discussed.