905 resultados para Mel frequency cepstrum coefficient (MFCC)
Resumo:
The flavonoid fraction was purified by a combination of chromatography on Amberlite XAD-2 and preparative silica gel TLC. Morin (3, 5, 7, 2', 4'- pentahydroxyflavone) was the only flavonol found in honey from Brazilian Citrus sp.. The structure of morin was determined on the basis of UV and ¹H and 13C NMR spectral data together with literature references. This is the first report on the isolation of morin from Brazilian Citrus honey.
Resumo:
Thirty three honey samples produced by four Melipona species from different areas of the State of Bahia, were analyzed with the aim to determine their physico-chemical characteristics, contributing to the establishment of standards for quality control. The majority of the average values for physico-chemical parameters fulfilled the quality criteria established by the Brazilian and international Legislations for Apis honey, except for moisture content, which afforded higher values. Concerning the high number of samples wich did not fit the limits for reducing sugars, it is necessary to define minimum values in order to characterize Melipona honeys, as well as criteria for use of diastasic activity.
Resumo:
In honey 5-hydroxymethyl-2-furaldehyde (HMF) is one of the most typical products of degradation: it is usually absent in fresh honey, but its concentration tends to rise as a result of heating processes or long-term storage. The validation protocol was performed in terms of detection and quantification limits, precision (by repeatability and intermediate precision), linearity and accuracy (by recovery tests). The method has been tested on 15 honey samples of different ages and geographical origin. HMF correlated highly with the age of the samples has been considered a very important parameter to put these honeys on the market or not and/or to estimate their shelf life.
Resumo:
The aim of the thesis is to investigate the hybrid LC filter behavior in modern power drives; to analyze the influence of such a du/dt filter on the control system stability. With the implementation of the inverter output RLC filter the motor control becomes more complicated. And during the design process the influence of the filter on the motor should be considered and the filter RLC parameters should be constrained.
Resumo:
This master’s thesis is focused on power supply network disturbances and their effects on the frequency converter – one of the components of modern process crane electrical system. The most critical disturbance types, their causes and the effect they bring to crane electrical system was determined in this work. Variety of protective devices used for mitigation of disturbances is investigated. Device protection solutions for the frequency converter used in crane applications are presented. Analyses of the power supply requirements for frequency converter and various components of crane electrical system were carried out and as a result the crane power supply requirements list that guarantees normal crane operation was built. This list is to be included in crane projects for troubleshooting purposes in order to determine potentially dangerous network.
Resumo:
The increasing power demand and emerging applications drive the design of electrical power converters into modularization. Despite the wide use of modularized power stage structures, the control schemes that are used are often traditional, in other words, centralized. The flexibility and re-usability of these controllers are typically poor. With a dedicated distributed control scheme, the flexibility and re-usability of the system parts, building blocks, can be increased. Only a few distributed control schemes have been introduced for this purpose, but their breakthrough has not yet taken place. A demand for the further development offlexible control schemes for building-block-based applications clearly exists. The control topology, communication, synchronization, and functionality allocationaspects of building-block-based converters are studied in this doctoral thesis. A distributed control scheme that can be easily adapted to building-block-based power converter designs is developed. The example applications are a parallel and series connection of building blocks. The building block that is used in the implementations of both the applications is a commercial off-the-shelf two-level three-phase frequency converter with a custom-designed controller card. The major challenge with the parallel connection of power stages is the synchronization of the building blocks. The effect of synchronization accuracy on the system performance is studied. The functionality allocation and control scheme design are challenging in the seriesconnected multilevel converters, mainly because of the large number of modules. Various multilevel modulation schemes are analyzed with respect to the implementation, and this information is used to develop a flexible control scheme for modular multilevel inverters.
Resumo:
Este artigo descreve a validação de método analítico para determinação do acaricida amitraz em mel utilizando extração com n-hexano/acetona, cleanup em cartucho de extração em fase sólida (SPE) e análise por cromatografia a gás com detector termoiônico seletivo (GC-TSD). O método pode ser utilizado para monitorar a presença do pesticida amitraz em mel, devido aos bons parâmetros analíticos, precisão (CV<11%) e exatidão (>80%) dentro do intervalo 100-400 ng g-1. O limite estabelecido na União Européia, pelo Committee for Veterinary Medicinal Products, para amitraz em mel (200 ng g-1) está dentro deste intervalo. A resposta do sistema analítico apresentou linearidade entre 100 e 800 ng mL-1 com coeficiente de correlação de 0,9996, limite de detecção (LD-7 ng g-1) e de quantificação (LQ-100 ng g-1). O método validado foi utilizado para avaliar a qualidade de méis comercializados na cidade de Araraquara/SP, nas quais não foram detectados resíduos de amitraz.
Resumo:
The purpose of this study was to evaluate the efficiency of integrated managements on white mold control on common bean. Initially, in vitro testing was made to assess the antagonism of 11 Trichoderma isolates against Sclerotinia sclerotiorum and to investigate fungicides (fluazinam and procymidone) inhibitory effects on those fungi. In two field experiments the following combinations were tested: irrigation frequencies (seven or 14 days), plant densities (six or 12 plants per meter), and three disease controls (untreated control, fungicide or Trichoderma spp.). In a third experiment plant densities were replaced by grass mulching treatments (with or without mulching). Fluazinam was applied at 45 and 55 days after emergence (DAE). The antagonists T. harzianum (experiments 1 and 3) and T. stromatica (experiment 2) were applied through sprinkler irrigation at 10 and 25 DAE, respectively. Most of the Trichoderma spp. were effective against the pathogen in vitro. Fluazinam was more toxic than procymidone to both the pathogen and the antagonist. Fungicide applications increased yield between 32 % and 41 %. In field one application of Trichoderma spp. did not reduce disease intensity and did not increase yield. The reduction from 12 to six plants per meter did not decrease yield, and disease severity diminished in one of the two experiments. It is concluded that of the strategies for white mold control just reduction of plant density and applications of fungicide were efficient.
Resumo:
Based on a polygenic system of a diploid species, without epistasis, and a population in Hardy-Weinberg equilibrium, without inbreeding and under linkage equilibrium, it can be shown that: (1) the narrow sense heritability at half-sib family level is equal to the square of the correlation coefficient between family mean and the additive genetic value of its common parent; (2) the narrow sense heritability at full-sib family level is equal to the square of the correlation coefficient between family mean and the mean of the additive genetic values of its parents; (3) the narrow sense heritability at Sn family level is exactly equal to the square of the correlation coefficient between family mean and the additive genetic value of its parent only in absence of dominance or when allele frequencies are equal; and (4) the broad sense heritability at full-sib or Sn family level can be used to analyze selection efficiency, since the progeny genotypic mean is, in general, a good indicator of parents, or Sn-1 plant superiority with respect to the frequency of favorable genes.
Resumo:
Centrifugal pumps are widely used in industrial and municipal applications, and they are an important end-use application of electric energy. However, in many cases centrifugal pumps operate with a significantly lower energy efficiency than they actually could, which typically has an increasing effect on the pump energy consumption and the resulting energy costs. Typical reasons for this are the incorrect dimensioning of the pumping system components and inefficiency of the applied pump control method. Besides the increase in energy costs, an inefficient operation may increase the risk of a pump failure and thereby the maintenance costs. In the worst case, a pump failure may lead to a process shutdown accruing additional costs. Nowadays, centrifugal pumps are often controlled by adjusting their rotational speed, which affects the resulting flow rate and output pressure of the pumped fluid. Typically, the speed control is realised with a frequency converter that allows the control of the rotational speed of an induction motor. Since a frequency converter can estimate the motor rotational speed and shaft torque without external measurement sensors on the motor shaft, it also allows the development and use of sensorless methods for the estimation of the pump operation. Still today, the monitoring of pump operation is based on additional measurements and visual check-ups, which may not be applicable to determine the energy efficiency of the pump operation. This doctoral thesis concentrates on the methods that allow the use of a frequency converter as a monitoring and analysis device for a centrifugal pump. Firstly, the determination of energy-efficiency- and reliability-based limits for the recommendable operating region of a variable-speed-driven centrifugal pump is discussed with a case study for the laboratory pumping system. Then, three model-based estimation methods for the pump operating location are studied, and their accuracy is determined by laboratory tests. In addition, a novel method to detect the occurrence of cavitation or flow recirculation in a centrifugal pump by a frequency converter is introduced. Its sensitivity compared with known cavitation detection methods is evaluated, and its applicability is verified by laboratory measurements for three different pumps and by using two different frequency converters. The main focus of this thesis is on the radial flow end-suction centrifugal pumps, but the studied methods can also be feasible with mixed and axial flow centrifugal pumps, if allowed by their characteristics.
Resumo:
Neste trabalho, estudou-se a influência do tipo de centrífuga utilizado no processamento do mel de abelha sobre os parâmetros reológicos, físico-químicos e sensoriais. Para a análise sensorial, trabalhou-se com 58 provadores que constataram mudanças no sabor das amostras. Na análise reológica, foi utilizado um reômetro RS50 conectado a um banho termostático K20-DC5, ambos da HAAKE, com um sensor de geometria cone-placa. Ocorreram diferenças significativas nos valores da viscosidade entre as duas amostras obtidas por meio dos respectivos modelos de centrífugas. O valor da viscosidade do mel obtido da centrífuga radial foi, aproximadamente, o dobro do valor do mel processado na centrífuga facial. Nenhuma alteração foi observada nos níveis de hidroximetilfurfural e umidade de ambas as amostras. No caso do mel obtido da centrífuga radial, obteve-se umidade de 20,6%, enquanto o mel processado na centrífuga facial apresentou umidade de 20,2%. Na análise sensorial, cerca de 69% dos provadores manifestaram preferência pelo mel processado na centrífuga radial, que consideraram o sabor doce menos acentuado e mais viscoso.
Resumo:
Resonance energy transfer (RET) is a non-radiative transfer of the excitation energy from the initially excited luminescent donor to an acceptor. The requirements for the resonance energy transfer are: i) the spectral overlap between the donor emission spectrum and the acceptor absorption spectrum, ii) the close proximity of the donor and the acceptor, and iii) the suitable relative orientations of the donor emission and the acceptor absorption transition dipoles. As a result of the RET process the donor luminescence intensity and the donor lifetime are decreased. If the acceptor is luminescent, a sensitized acceptor emission appears. The rate of RET depends strongly on the donor–acceptor distance (r) and is inversely proportional to r6. The distance dependence of RET is utilized in binding assays. The proximity requirement and the selective detection of the RET-modified emission signal allow homogeneous separation free assays. The term lanthanide-based RET is used when luminescent lanthanide compounds are used as donors. The long luminescence lifetimes, the large Stokes’ shifts and the intense, sharply-spiked emission spectra of the lanthanide donors offer advantages over the conventional organic donor molecules. Both the organic lanthanide chelates and the inorganic up-converting phosphor (UCP) particles have been used as donor labels in the RET based binding assays. In the present work lanthanide luminescence and lanthanide-based resonance energy transfer phenomena were studied. Luminescence lifetime measurements had an essential role in the research. Modular frequency-domain and time-domain luminometers were assembled and used successfully in the lifetime measurements. The frequency-domain luminometer operated in the low frequency domain ( 100 kHz) and utilized a novel dual-phase lock-in detection of the luminescence. One of the studied phenomena was the recently discovered non-overlapping fluorescence resonance energy transfer (nFRET). The studied properties were the distance and temperature dependences of nFRET. The distance dependence was found to deviate from the Förster theory and a clear temperature dependence was observed whereas conventional RET was completely independent of the temperature. Based on the experimental results two thermally activated mechanisms were proposed for the nFRET process. The work with the UCP particles involved the measurement of the luminescence properties of the UCP particles synthesized in our laboratory. The goal of the UCP particle research is to develop UCP donor labels for binding assays. In the present work the effect of the dopant concentrations and the core–shell structure on the total up-conversion luminescence intensity, the red–green emission ratio, and the luminescence lifetime was studied. Also the non-radiative nature of the energy transfer from the UCP particle donors to organic acceptors was demonstrated for the first time in aqueous environment and with a controlled donor–acceptor distance.
Resumo:
The intensity-duration-frequency occurrence ratio (IDF) is a tool commonly used for precipitation-runoff data transformation, which is established from observations of intense precipitations over a period sufficiently long as to allow the occurrence of extremes at the observation site. This study focused on verifying the existence or absence of new data, in terms of IDF ratio, by using partial duration records produced from data on maximum daily disaggregated rainfall for pre determined durations. The partial duration records considered a base value of 55 mm, totaling 279 values. After the rainfall series were established, their independence and seasonality were assessed. Using the Student's t-test statistics, it was established that no new data, as IDF ratio, emerged from the analysis of the partial duration series with the recommended base value of precipitation, as compared to the historical records.