960 resultados para Medical Literature
Resumo:
This study examined the clinical, histological, and immunohistochemical features as well as the differential diagnoses of oral intravascular papillary endothelial hyperplasia (IPEH) to aid clinicians and pathologists in its diagnosis. Clinical features of five oral IPEH cases were obtained from medical records, and all histopathological diagnoses were reviewed. Immunohistochemical reactions, including anti-CD-34, laminin, vimentin, estrogen receptor alpha, and Ki-67, were assessed. Microscopically, a reactive proliferation of vascular cells composed of small papillary structures with hypocellular and hyalinized cores arising in an organized thrombus was seen. CD-34, vimentin, and laminin staining were strongly positive, while estrogen receptor alpha was negative in all cases. A low percentage of cells were positive for Ki-67 in four of five lesions, but one case was strongly positive. A diagnosis of angiosarcoma was investigated and rejected. IPEH presents specific microscopic characteristics that along with clinical data lead to an accurate diagnosis. The general dentist, the first to participate in the diagnostic process, must share the responsibility for diagnosis with the pathologist, and they must work together to determine the correct diagnosis and management. Oral lesions of IPEH are uncommon. Their main significance is that they show a microscopic resemblance to angiosarcoma. Thus, clinicians should have more information regarding this benign entity. Finally, we suggest that in recurrent cases exhibiting strong immunolabeling of proliferative markers the possibility of angiosarcoma should be investigated.
Resumo:
Tumoural and cystic lesions are common findings in the daily practice of dental professionals and maxillofacial radiologists. However, simultaneous lesions are rare and represent a diagnostic challenge to overcome. Among tumoural pathologies, odontomas are the most common odontogenic tumour of the jaws. Cystic transformation or development from the tumoural capsule are well recognized in situations such as ameloblastomas originated from a dentigerous cyst. Otherwise, despite literature reports, dentigerous cysts arising from odontomas are very rare and could lead to misdiagnosis. Here, we report a case of a complex odontoma associated with a dentigerous cyst in the maxillary sinus, focussing on the tomographic features and a differential imaging approach to the diagnosis of these lesions.
Resumo:
Background: Orofacial granulomatosis is a clinical entity presenting with swelling of the facial and/or oral tissues in association with histologic evidence of noncaseating granulomatous inflammation. Labial swelling is the most common finding. Compromise of the gingival and periodontal tissues may occur but has rarely been described in the literature. Our objective was to characterize granulomatous gingivitis in patients with orofacial granulomatosis. Observations: The study included 29 cases of orofacial granulomatosis seen in our clinic between January 1, 1989, and December 31, 2006. Of these 29, 5 had clinical evidence of gingival tumefaction and underwent gingival biopsy. Histologic examination of all the gingival biopsy specimens showed noncaseating granulomas, edema of the superficial lamina propria, and a chronic inflammatory infiltrate consisting predominantly of lymphocytes and multinucleated giant cells. Treatment options included anti-inflammatory therapy associated with periodontal care. Conclusion: Gingival tumefaction with histologic evidence of granulomatous inflammation may occur in orofacial granulomatosis and might be more common than reported in the literature.
Resumo:
Objective. The goal of this paper is to undertake a literature search collecting all dentin bond strength data obtained for six adhesives with four tests ( shear, microshear, tensile and microtensile) and to critically analyze the results with respect to average bond strength, coefficient of variation, mode of failure and product ranking. Method. A PubMed search was carried out for the years between 1998 and 2009 identifying publications on bond strength measurements of resin composite to dentin using four tests: shear, tensile, microshear and microtensile. The six adhesive resins were selected covering three step systems ( OptiBond FL, Scotch Bond Multi-Purpose Plus), two-step (Prime & Bond NT, Single Bond, Clear. l SE Bond) and one step (Adper Prompt L Pop). Results. Pooling results from 147 references showed an ongoing high scatter in the bond strength data regardless which adhesive and which bond test was used. Coefficients of variation remained high (20-50%) even with the microbond test. The reported modes of failure for all tests still included high number of cohesive failures. The ranking seemed to be dependant on the test used. Significance. The scatter in dentin bond strength data remains regardless which test is used confirming Finite Element Analysis predicting non-uniform stress distributions due to a number of geometrical, loading, material properties and specimens preparation variables. This reopens the question whether, an interfacial fracture mechanics approach to analyze the dentin - adhesive bond is not more appropriate for obtaining better agreement among dentin bond related papers. (C) 2009 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
Ehlers-Danlos syndrome (EDS) is a hereditary disorder of the connective tissue related to collagen metabolism. Deficiency or alteration of the collagen present in the tissues results in some classic signs such as skin hyperelasticity, articular hypermobility, and vascular fragility, among others. In addition, EDS oral manifestations are rarely cited in the literature. The aim of this article is to report a rare case of a young female patient with EDS who presented supernumerary teeth and an odontogenic keratocyst. There is no report in the literature of the simultaneous occurrence of these alterations. The article further highlights the importance of EDS diagnosis in patients who need dental treatment and the due care for their assistance.
Resumo:
Introduction: Recently developed portable dental X-ray units increase the mobility of the forensic odontologists and allow more efficient X-ray work in a disaster field, especially when used in combination with digital sensors. This type of machines might also have potential for application in remote areas, military and humanitarian missions, dental care of patients with mobility limitation, as well as imaging in operating rooms. Objective: To evaluate radiographic image quality acquired by three portable X-ray devices in combination with four image receptors and to evaluate their medical physics parameters. Materials and methods: Images of five samples consisting of four teeth and one formalin-fixed mandible were acquired by one conventional wall-mounted X-ray unit, MinRay (R) 60/70 kVp, used as a clinical standard, and three portable dental X-ray devices: AnyRay (R) 60 kVp, Nomad (R) 60 kVp and Rextar (R) 70 kVp, in combination with a phosphor image plate (PSP), a CCD, or a CMOS sensor. Three observers evaluated images for standard image quality besides forensic diagnostic quality on a 4-point rating scale. Furthermore, all machines underwent tests for occupational as well as patient dosimetry. Results: Statistical analysis showed good quality imaging for all system, with the combination of Nomad (R) and PSP yielding the best score. A significant difference in image quality between the combination of the four X-ray devices and four sensors was established (p < 0.05). For patient safety, the exposure rate was determined and exit dose rates for MinRay (R) at 60 kVp, MinRay (R) at 70 kVp, AnyRay (R), Nomad (R) and Rextar (R) were 3.4 mGy/s, 4.5 mGy/s, 13.5 mGy/s, 3.8 mGy/s and 2.6 mGy/s respectively. The kVp of the AnyRay (R) system was the most stable, with a ripple of 3.7%. Short-term variations in the tube output of all the devices were less than 10%. AnyRay (R) presented higher estimated effective dose than other machines. Occupational dosimetry showed doses at the operator`s hand being lowest with protective shielding (Nomad (R): 0.1 mu Gy). It was also low while using remote control (distance > 1 m: Rextar (R) < 0.2 mu Gy, MinRay (R) < 0.1 mu Gy). Conclusions: The present study demonstrated the feasibility of three portable X-ray systems to be used for specific indications, based on acceptable image quality and sufficient accuracy of the machines and following the standard guidelines for radiation hygiene. (C) 2010 Elsevier Ireland Ltd. All rights reserved.