947 resultados para Materiali compositi, CFRP, Combined Loading Compression (CLC) test method


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Bone metastases are responsible for different clinical complications defined as skeletal-related events (SREs) such as pathologic fractures, spinal cord compression, hypercalcaemia, bone marrow infiltration and severe bone pain requiring palliative radiotherapy. The general aim of these three years research period was to improve the management of patients with bone metastases through two different approaches of translational research. Firstly in vitro preclinical tests were conducted on breast cancer cells and on indirect co-colture of cancer cells and osteoclasts to evaluate bone targeted therapy singly and in combination with conventional chemotherapy. The study suggests that zoledronic acid has an antitumor activity in breast cancer cell lines. Its mechanism of action involves the decrease of RAS and RHO, as in osteoclasts. Repeated treatment enhances antitumor activity compared to non-repeated treatment. Furthermore the combination Zoledronic Acid + Cisplatin induced a high antitumoral activity in the two triple-negative lines MDA-MB-231 and BRC-230. The p21, pMAPK and m-TOR pathways were regulated by this combined treatment, particularly at lower Cisplatin doses. A co-colture system to test the activity of bone-targeted molecules on monocytes-breast conditioned by breast cancer cells was also developed. Another important criticism of the treatment of breast cancer patients, is the selection of patients who will benefit of bone targeted therapy in the adjuvant setting. A retrospective case-control study on breast cancer patients to find new predictive markers of bone metastases in the primary tumors was performed. Eight markers were evaluated and TFF1 and CXCR4 were found to discriminate between patients with relapse to bone respect to patients with no evidence of disease. In particular TFF1 was the most accurate marker reaching a sensitivity of 63% and a specificity of 79%. This marker could be a useful tool for clinicians to select patients who could benefit for bone targeted therapy in adjuvant setting.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

L’attività di ricerca della presente tesi di dottorato ha riguardato sistemi tribologici complessi di interesse industriale per i quali sono stati individuati, mediante failure analysis, i meccanismi di usura dominanti. Per ciascuno di essi sono state studiate soluzioni migliorative sulla base di prove tribologiche di laboratorio. Nella realizzazione di maglie per macchine movimentazione terra sono ampiamente utilizzati i tradizionali acciai da bonifica. La possibilità di utilizzare i nuovi microlegati a medio tenore di carbonio, consentirebbe una notevole semplificazione del ciclo produttivo e benefici in termini di costi. Una parte della tesi ha riguardato lo studio del comportamento tribologico di tali acciai. E’ stato anche affrontato lo studio tribologico di motori idraulici, con l’obiettivo di riuscire a migliorarne la resistenza ad usura e quindi la vita utile. Sono state eseguite prove a banco, per valutare i principali meccanismi di usura, e prove di laboratorio atte a riprodurre le reali condizioni di utilizzo, valutando tecniche di modificazione superficiale che fossero in grado di ridurre l’usura dei componenti. Sono state analizzate diverse tipologie di rivestimenti Thermal Spray in termini di modalità di deposizione (AFS-APS) e di leghe metalliche depositate (Ni,Mo,Cu/Al). Si sono infine caratterizzati contatti tribologici nel settore del packaging, dove l’utilizzo di acciai inox austenitici è in alcuni casi obbligatorio. L’acciaio inossidabile AISI 316L è ampiamente utilizzato in applicazioni in cui siano richieste elevate resistenze alla corrosione, tuttavia la bassa resistenza all’usura, ne limitano l’impiego in campo tribologico. In tale ambito, è stata analizzata una problematica tribologica relativa a macchine automatiche per il dosaggio di polveri farmaceutiche. Sono state studiate soluzioni alternative che hanno previsto sia la completa sostituzione dei materiali della coppia tribologica, sia l’individuazione di tecniche di modificazione superficiale innovative quali la cementazione a bassa temperatura anche seguita dalla deposizione di un rivestimento di carbonio amorfo idrogenato a-C:H

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Lo studio si propone di valutare la capacità dei reticoli di Bragg in fibra ottica, di individuare e monitorare danneggiamenti presenti all'interno di laminati in composito, tramite l'analisi degli spettri riflessi dai reticoli stessi. Sono stati utilizzati due tipi diversi di stratificazione dei laminati, per valutare il diverso comportamento dei reticoli di Bragg inseriti all'interno dei laminati. Le proprietà dei materiali e degli spettri riflessi dai reticoli, sono state messe in relazione qualitativamente e quantitativamente, al fine di sviluppare un valido metodo di Structural Health Monitoring.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The goal of this thesis was the study of the cement-bone interface in the tibial component of a cemented total knee prosthesis. One of the things you can see in specimens after in vivo service is that resorption of bone occurs in the interdigitated region between bone and cement. A stress shielding effect was investigated as a cause to explain bone resorption. Stress shielding occurs when bone is loaded less than physiological and therefore it starts remodeling according to the new loading conditions. µCT images were used to obtain 3D models of the bone and cement structure and a Finite Element Analysis was used to simulate different kind of loads. Resorption was also simulated by performing erosion operations in the interdigitated bone region. Finally, 4 models were simulated: bone (trabecular), bone with cement, and two models of bone with cement after progressive erosions of the bone. Compression, tension and shear test were simulated for each model in displacement-control until 2% of strain. The results show how the principal strain and Von Mises stress decrease after adding the cement on the structure and after the erosion operations. These results show that a stress shielding effect does occur and rises after resorption starts.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the last decade the near-surface mounted (NSM) strengthening technique using carbon fibre reinforced polymers (CFRP) has been increasingly used to improve the load carrying capacity of concrete members. Compared to externally bonded reinforcement (EBR), the NSM system presents considerable advantages. This technique consists in the insertion of carbon fibre reinforced polymer laminate strips into pre-cut slits opened in the concrete cover of the elements to be strengthened. CFRP reinforcement is bonded to concrete with an appropriate groove filler, typically epoxy adhesive or cement grout. Up to now, research efforts have been mainly focused on several structural aspects, such as: bond behaviour, flexural and/or shear strengthening effectiveness, and energy dissipation capacity of beam-column joints. In such research works, as well as in field applications, the most widespread adhesives that are used to bond reinforcements to concrete are epoxy resins. It is largely accepted that the performance of the whole application of NSM systems strongly depends on the mechanical properties of the epoxy resins, for which proper curing conditions must be assured. Therefore, the existence of non-destructive methods that allow monitoring the curing process of epoxy resins in the NSM CFRP system is desirable, in view of obtaining continuous information that can provide indication in regard to the effectiveness of curing and the expectable bond behaviour of CFRP/adhesive/concrete systems. The experimental research was developed at the Laboratory of the Structural Division of the Civil Engineering Department of the University of Minho in Guimar\~aes, Portugal (LEST). The main objective was to develop and propose a new method for continuous quality control of the curing of epoxy resins applied in NSM CFRP strengthening systems. This objective is pursued through the adaptation of an existing technique, termed EMM-ARM (Elasticity Modulus Monitoring through Ambient Response Method) that has been developed for monitoring the early stiffness evolution of cement-based materials. The experimental program was composed of two parts: (i) direct pull-out tests on concrete specimens strengthened with NSM CFRP laminate strips were conducted to assess the evolution of bond behaviour between CFRP and concrete since early ages; and, (ii) EMM-ARM tests were carried out for monitoring the progressive stiffness development of the structural adhesive used in CFRP applications. In order to verify the capability of the proposed method for evaluating the elastic modulus of the epoxy, static E-Modulus was determined through tension tests. The results of the two series of tests were then combined and compared to evaluate the possibility of implementation of a new method for the continuous monitoring and quality control of NSM CFRP applications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The evaluation of the knee joint behavior is fundamental in many applications, such as joint modeling, prosthesis and orthosis design. In-vitro tests are important in order to analyse knee behavior when simulating various loading conditions and studying physiology of the joint. A new test rig for in-vitro evaluation of the knee joint behavior is presented in this paper. It represents the evolution of a previously proposed rig, designed to overcome its principal limitations and to improve its performances. The design procedure and the adopted solution in order to satisfy the specifications are presented here. Thanks to its 6-6 Gough-Stewart parallel manipulator loading system, the rig replicates general loading conditions, like daily actions or clinical tests, on the specimen in a wide range of flexion angles. The restraining actions of knee muscles can be simulated when active actions are simulated. The joint motion in response to the applied loads, guided by passive articular structures and muscles, is permitted by the characteristics of the loading system which is force controlled. The new test rig guarantees visibility so that motion can be measured by an optoelectronic system. Furthermore, the control system of the new test rig allows the estimation of the contribution of the principal leg muscles in guaranteeing the equilibrium of the joint by the system for muscle simulation. Accuracy in positioning is guaranteed by the designed tibia and femur fixation systems,which allow unmounting and remounting the specimen in the same pose. The test rig presented in this paper permits the analysis of the behavior of the knee joint and comparative analysis on the same specimen before and after surgery, in a way to assess the goodness of prostheses or surgical treatments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mountainous areas are prone to natural hazards like rockfalls. Among the many countermeasures, rockfall protection barriers represent an effective solution to mitigate the risk. They are metallic structures designed to intercept rocks falling from unstable slopes, thus dissipating the energy deriving from the impact. This study aims at providing a better understanding of the response of several rockfall barrier types, through the development of rather sophisticated three-dimensional numerical finite elements models which take into account for the highly dynamic and non-linear conditions of such events. The models are built considering the actual geometrical and mechanical properties of real systems. Particular attention is given to the connecting details between the structural components and to their interactions. The importance of the work lies in being able to support a wide experimental activity with appropriate numerical modelling. The data of several full-scale tests carried out on barrier prototypes, as well as on their structural components, are combined with results of numerical simulations. Though the models are designed with relatively simple solutions in order to obtain a low computational cost of the simulations, they are able to reproduce with great accuracy the test results, thus validating the reliability of the numerical strategy proposed for the design of these structures. The developed models have shown to be readily applied to predict the barrier performance under different possible scenarios, by varying the initial configuration of the structures and/or of the impact conditions. Furthermore, the numerical models enable to optimize the design of these structures and to evaluate the benefit of possible solutions. Finally it is shown they can be also used as a valuable supporting tool for the operators within a rockfall risk assessment procedure, to gain crucial understanding of the performance of existing barriers in working conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

I materiali (nano)compositi, unendo al loro interno le prestazioni dei loro componenti, che in alcuni casi possono addirittura agire sinergicamente sviluppando nuove proprietà non appartenenti alle singole fasi isolate, appaiono come una risposta ottimale alle nuove esigenze che richiedono materiali performanti dal punto di vista meccanico e sempre più dotati di funzionalità aggiuntive. È noto come l’uso di nanocariche consenta non solo di migliorare le proprietà meccaniche, ma di aggiungere proprietà funzionali di varia natura. In questo lavoro di tesi si sono quindi valutate due tipologie di nanocariche, grafene e organoclay (ritardante di fiamma), come modificatori di una matrice epossidica commerciale. La stessa matrice è stata utilizzata anche per produrre compositi contenenti fibra di carbonio riciclata da pirolisi, con la prospettiva futura di unire i processi e ottenere compositi da fibra di riciclo e matrice multifunzionale.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In questo lavoro di tesi sono state evidenziate alcune problematiche relative alle macchine exascale (sistemi che sviluppano un exaflops di Potenza di calcolo) e all'evoluzione dei software che saranno eseguiti su questi sistemi, prendendo in esame principalmente la necessità del loro sviluppo, in quanto indispensabili per lo studio di problemi scientifici e tecnologici di più grandi dimensioni, con particolare attenzione alla Material Science, che è uno dei campi che ha avuto maggiori sviluppi grazie all'utilizzo di supercomputer, ed ad uno dei codici HPC più utilizzati in questo contesto: Quantum ESPRESSO. Dal punto di vista del software sono state presentate le prime misure di efficienza energetica su architettura ibrida grazie al prototipo di cluster EURORA sul software Quantum ESPRESSO. Queste misure sono le prime ad essere state pubblicate nel contesto software per la Material Science e serviranno come baseline per future ottimizzazioni basate sull'efficienza energetica. Nelle macchine exascale infatti uno dei requisiti per l'accesso sarà la capacità di essere energeticamente efficiente, così come oggi è un requisito la scalabilità del codice. Un altro aspetto molto importante, riguardante le macchine exascale, è la riduzione del numero di comunicazioni che riduce il costo energetico dell'algoritmo parallelo, poiché in questi nuovi sistemi costerà di più, da un punto di vista energetico, spostare i dati che calcolarli. Per tale motivo in questo lavoro sono state esposte una strategia, e la relativa implementazione, per aumentare la località dei dati in uno degli algoritmi più dispendiosi, dal punto di vista computazionale, in Quantum ESPRESSO: Fast Fourier Transform (FFT). Per portare i software attuali su una macchina exascale bisogna iniziare a testare la robustezza di tali software e i loro workflow su test case che stressino al massimo le macchine attualmente a disposizione. In questa tesi per testare il flusso di lavoro di Quantum ESPRESSO e WanT, un software per calcolo di trasporto, è stato caratterizzato un sistema scientificamente rilevante costituito da un cristallo di PDI - FCN2 che viene utilizzato per la costruzione di transistor organici OFET. Infine è stato simulato un dispositivo ideale costituito da due elettrodi in oro con al centro una singola molecola organica.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

La determinazione del modulo di Young è fondamentale nello studio della propagazione di fratture prima del rilascio di una valanga e per lo sviluppo di affidabili modelli di stabilità della neve. Il confronto tra simulazioni numeriche del modulo di Young e i valori sperimentali mostra che questi ultimi sono tre ordini di grandezza inferiori a quelli simulati (Reuter et al. 2013)⁠. Lo scopo di questo lavoro è stimare il modulo di elasticità studiando la dipendenza dalla frequenza della risposta di diversi tipi di neve a bassa densità, 140-280 kg m-3. Ciò è stato fatto applicando una compressione dinamica uniassiale a -15°C nel range 1-250 Hz utilizzando il Young's modulus device (YMD), prototipo di cycling loading device progettato all'Istituto per lo studio della neve e delle valanghe (SLF). Una risposta viscoelastica della neve è stata identificata a tutte le frequenze considerate, la teoria della viscoelasticità è stata applicata assumendo valida l'ipotesi di risposta lineare della neve. Il valore dello storage modulus, E', a 100 Hz è stato identificato come ragionevolmente rappresentativo del modulo di Young di ciascun campione neve. Il comportamento viscoso è stato valutato considerando la loss tangent e la viscosità ricavata dai modelli di Voigt e Maxwell. Il passaggio da un comportamento più viscoso ad uno più elastico è stato trovato a 40 Hz (~1.1•10-2 s-1). Il maggior contributo alla dissipazione è nel range 1-10 Hz. Infine, le simulazioni numeriche del modulo di Young sono state ottenute nello stesso modo di Reuter et al.. La differenza tra le simulazioni ed i valori sperimentali di E' sono, al massimo, di un fattore 5; invece, in Reuter et al.⁠, era di 3 ordini di grandezza. Pertanto, i nostri valori sperimentali e numerici corrispondono meglio, indicando che il metodo qui utilizzato ha portato ad un miglioramento significativo.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Analisi riguardante la tenacizzazione della matrice di laminati compositi. Lo scopo è quello di aumentare la resistenza alla frattura di modo I e, a tal proposito, sono stati modificati gli interstrati di alcuni provini tramite l’introduzione di strati, di diverso spessore, di nanofibre in polivinilidenfluoruro (PVDF). La valutazione di tale metodo di rinforzo è stata eseguita servendosi di dati ottenuti tramite prove sperimentali svolte in laboratorio direttamente dal sottoscritto, che si è occupato dell’elaborazione dei dati servendosi di tecniche e algoritmi di recente ideazione. La necessità primaria per cui si cerca di rinforzare la matrice risiede nel problema più sentito dei laminati compositi in opera da molto tempo: la delaminazione. Oltre a verificare le proprietà meccaniche dei provini modificati sottoponendoli a test DCB, si è utilizzata una tecnica basata sulle emissioni acustiche per comprendere più approfonditamente l’inizio della delaminazione e i meccanismi di rottura che si verificano durante le prove. Quest’ultimi sono illustrati servendosi di un algoritmo di clustering, detto Fuzzy C-means, tramite il quale è stato possibile identificare ogni segnale come appartenente o meno ad un determinato modo di rottura. I risultati mostrano che il PVDF, applicato nelle modalità esposte, è in grado di aumentare la resistenza alla frattura di modo I divenendo contemporaneamente causa di un diverso modo di propagazione della frattura. Infine l’elaborato presenta alcune micrografie delle superfici di rottura, le quali appoggiano i risultati ottenuti nelle precedenti fasi di analisi.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The new knee test rig developed in University of Bologna used pneumatic cylinder as actuator system. Specific characterization and modelling about the pneumatic cylinder and the related devices are needed in better controlling the test rig. In this thesis, an experimental environment for the related device is set up with data acquisition system using Real-time Windows Target, Simulink, MatLab. Based on the experimental data, a fitted model for the pneumatic cylinder friction is found.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In questo lavoro di tesi è stato sviluppato uno scaffold biomimetico e bioattivo per la rigenerazione cartilaginea. Questo scaffold è in grado di coordinare il processo di rigenerazione di difetti condrali e promuovere la formazione di cartilagine ialina o ‘hyaline-like’ ben integrata con l’osso subcondrale. Lo scaffold realizzato è composto da due strati, uno strato cartilagineo e uno strato calficato, al fine di mimare la complessa interfaccia presente tra la cartilagine articolare e l’osso subcondrale. Lo spessore degli strati, l’adesione tra questi e la presenza di porosità è stata valutata mediante microscopia elettronica a scansione (SEM). Sono state effettuate analisi termogravimetriche (TGA) per determinare la percentuale di acqua residua nel campione dopo il processo di liofilizzazione e il residuo minerale nel campione stesso. Nell’ottica di ottimizzazione del processo di sintesi dello scaffold è stato valutato il grado di reticolazione del campione e il tempo di degradazione. Infine, per valutare la possibilità d’impianto è stato effettuato un test d’impianto su cadavere umano durante il quale diversi campioni, con forma rotonda o quadrata, sono stati impiantati e fissati con diverse tecniche.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: There are still limited data on the outcomes of regenerative periodontal surgery using a combination of an enamel matrix protein derivative (EMD) and autogenous bone (AB). AIM: To evaluate the healing of deep intrabony defects treated with either a combination EMD+AB or EMD alone. MATERIALS AND METHODS: Forty patients with advanced chronic periodontitis, with one deep intrabony defect, were randomly treated with either EMD+AB (test) or EMD (control). Clinical assessments were performed at baseline and at 1 year after treatment. The primary outcome variable was relative attachment level (RAL). RESULTS: Healing was uneventful in all patients. The test sites showed a reduction in the mean probing pocket depth (PPD) of 5.6 +/- 0.9 mm (p<0.001), a gain in the mean RAL of 4.2 +/- 1.1 mm (p<0.001) and a gain in the mean probing bone level (PBL) of 3.9 +/- 1.0 mm (p<0.001). The control group displayed a mean PPD reduction of 4.6 +/- 0.4 mm (p<0.001), a mean RAL gain of 3.4 +/- 0.8 mm (p<0.001) and a mean PBL gain of 2.8 +/- 0.8 mm (p<0.001). RAL gains of > or =4 mm were measured in 90% of the test defects and in 55% of the controls. PBL gains of > or =4 mm were obtained in 85% of the test defects and in 25% of the control ones. The test treatment resulted in statistically higher PPD reductions, RAL gains and PBL gains compared with the control (p<0.01). CONCLUSIONS: Within their limits, the present results indicate that: (i) at 1 year after surgery, both therapies resulted in statistically significant clinical improvements compared with baseline and (ii) although the combination of EMD+AB resulted in statistically significant higher soft and hard tissue improvements compared with treatment with EMD, the clinical relevance of this finding is unclear.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effect of acetyl-L-carnitine (ALCAR) supplementation to 3-month-old rats in normal-loading and unloading conditions has been here investigated by a combined morphological, biochemical and transcriptional approach to test whether ALCAR might cause a remodeling of the metabolic/contractile phenotype of soleus muscle. Morphological assessment demonstrated an increase of type I oxidative fiber content and cross-sectional area in ALCAR-treated animals both in normal-loading and in unloading conditions. ALCAR prevented loss of mitochondrial mass in unloaded animals whereas no ALCAR-dependent increase of mitochondrial mass occurred in normal-loaded muscle. Validated microarray analysis delineated an ALCAR-induced maintenance of a slow-oxidative expression program only in unloaded soleus muscle. Indeed, the muscle adjustment of the expression profile of factors underlying mitochondrial oxidative metabolism, protein turnover, fiber type differentiation and an adaptation of voltage-gated ion channel expression was distinguishable with respect to the loading status. This selectivity may suggest a key role of muscle loading status in the manifestation of ALCAR effects. The results extend to a broader level of biological informations the previous notion on ALCAR positive effect in rat soleus muscle during unloading and point to a role of ALCAR for the maintenance of its slow-oxidative fiber character.