999 resultados para Média potência


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to analyze the relationship of maximal aerobic power and the muscular strength (maximal isotonic strength and vertical jump explosive power) with the running economy (RE) in endurance athletes. Twenty-six male runners (27.9 ± 6.4 years; 62.7 ± 4.3 kg; 168.6 ± 6.1 cm; 6.6 ± 3.1% of body fat) performed in different days the following tests: a) incremental test to determine the maximal oxygen uptake (V̇O2max) and the intensity corresponding to the V̇O2max (IV̇O2max); b) constant-velocity treadmill run to determine RE; c) 1-RM test in the leg press and; d) maximal vertical jump test (VJ). V̇O2max (63.8 ± 8.3 ml/kg/min) was significantly correlated (r = 0.63; p < 0.05) with RE (48.0 ± 6.6 ml/kg/min). However, the IV̇O2max (18.7 ± 1.1 km/h), the maximal isotonic strength (230.3 ± 41.2 kg) and the VJ (30.8 ± 3.8 cm) were not significantly correlated with RE. One concludes that the maximal aerobic power can explain in part the inter-individual RE variability in endurance athletes. However, maximal isotonic strength and explosive strength seem not to be associated with RE values observed in this group of athletes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The perceived exertion has been a target of several investigations, many times with association with objective physiological indicators in exercise. Recently, the identification of the perceived exertion threshold (PET) was proposed in the water running, which presented no difference in relation to the critical velocity. Theoretically, both parameters would be indicators of the maximum steady state of variables such as V̇O2 and blood lactate. The objective of this work was to verify the coincidence between PET, critical power (PCrit) and an indicator of maximum V̇O2 steady state (PCrit') in cycle ergometer. Eight male participants were submitted to progressive effort test in order to determine V̇O2peak (46.7 ± 8.5 ml/kg/min) and to four rectangular tests until exhaustion for the estimation of the critical power model parameters, PET and PCrit'. The hyperbolic relation between mechanical power and time spent for the V̇O2peak to be reached in each test was used for the PCrit' estimation, considered as the asymptote in the power axis, and the portion of the anaerobic work capacity (CTAnaer) depleted up to the establishment of the V̇O2peak (CTAnaer'). In order to identify PET, the straight lines angular coefficients of the perceived exertion in time (ordinate) and the powers used (abscissa) were adjusted to a linear function that provided a point in the power axis in which the perceived exertion would be kept indefinitely stable. The parameters PCrit and CTAnaer were estimated by means of the power-time non-linear equation. In order to compare the estimations of PET, PCrit and PCrit', the analysis of variance ANOVA for repeated measurements was employed, and the associations were established through the Pearson correlation. CTAnaer and CTAnaer' were compared through the t test. PET (180 W ± 61 W), PCrit (174 W ± 43 W) and PCrit' (176 W ± 48 W) were not significantly different and the correlations were of 0.92-0.98. CTAnaer' (14,080 ± 5,219 J) was lower than CTAnaer (22,093 ± 9,042 J). One concludes that the PET predicts the intensity of PCrit and PCrit' with accuracy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The present study aimed at evaluating the occurrence and recurrence of middle ear effusion and possible associated factors in the first two years of life of 190 newborns and infants, participants in the interdisciplinary prevention, detection, and intervention program at the Clínica de Educação para Saúde of Universidade do Sagrado Coração. Methods: Newborns and infants were monthly submitted to anamneses, otoscopy, behavioral hearing assessment using sound instruments and pure tones (pediatric audiometry) and tympanometry. Results: The results revealed that 68.4% of infants presented one or more episodes of middle ear effusion during their two first years, with more recurrence among males. Peak occurrence was between four and 12 months of age and, the earlier the first episode, the higher the probability of recurrence. Greatest incidence was during May and August. It was found that, of the variables investigated, the period of exclusive breastfeeding actuated as a protector factor. With respect of risk factors, it was observed that passive smoking, gastro-esophageal reflux and respiratory allergy were related with the recurrences of effusion. Conclusion: Findings revealed the importance of periodic auditory follow-up for infants during their first two years of life, considered to be the critical period of auditory system maturation, during which sensory deprivation can be responsible for damage to the development of speech, language and other auditory abilities. © 2007 Sociedad Chilena de Pediatría.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a method for the sequential road feature delineation from digital images. It is based on a feedback loop between extrapolation and refinement steps of a given road centerline point, using in both steps correlation techniques. Firstly, a previously extracted road centerline point is linearly extrapolated, resulting in an approximate position. Secondly, this approximate position is corrected by comparing gray level profiles extracted perpendicularly to the extrapolation direction. This strategy is then repeated to allow the entire road centerline to be extracted or a stop point to be found. In order to initialize the extraction process, the operator needs to supply a starting point plus direction and width. Experimental results obtained from the application of the method to real image data are presented and discussed in this paper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work pointed out forming elements from the conception of special necessities that the media show the audience by the movies. An expression description has established special needs and they were identified as keywords on a search of movies (1994-2004) which were analyzed by two observers, according to a script. The results showed that 33 of the movies selected, 39.9% were classified in the ramacategory; 64% shows the disability as organic nature and 57% with predominant clinic diagnoses. Many labeled practices were identified (85%) and few accessibilities options (76%). In 85% of the movies the disability is said a manifestation of problems with few (58%) professionals intervention. The results are discussed by the media role on the concept formation of disabilities, offering interaction models with important role on social practice specification or unsuitable to the relation with the diversity and to the culture.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes and describes a high power factor AC-AC converter for naval applications using Permanent Magnet Generator (PMG). The three-phase output voltages of the PMG vary from 260 Vrms (220 Hz) to 380 Vrms (360 Hz), depending on load conditions. The proposed converter consists of a Y-/ΔY power transformer, which provides electrical isolation between the PMG and remaining stages, and a twelve-pulse uncontrolled rectifier stage directly connected to a single-phase inverter stage, without the use of an intermediary DC-DC topology. This proposal results in more simplicity for the overall circuitry, assuring robustness, reliability and reduced costs. Furthermore, the multipulse rectifier stage is capable to provide high power factor and low total harmonic distortion for the input currents of the converter. The single-phase inverter stage was designed to operate with wide range of DC bus voltage, maintaining 120 Vrms, 60 Hz output. The control philosophy, implemented in a digital signal processor (DSP) which also contains protection routines, alows series connections between two identical converters, achieving 240 Vrms, 60 Hz total output voltage. Measured total harmonic distortion for the AC output voltage is lower than 2% and the input power factor is 0.93 at 3.6kW nominal load. © 2010 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper the point estimation method is applied to solve the probabilistic power flow problem for unbalanced three-phase distribution systems. Through the implementation of this method the probability distribution functions of voltages (magnitude and angle) as well as the active and reactive power flows in the branches of the distribution system are determined. Two different approaches of the point estimation method are presented (2m and 2m+1 point schemes). In order to test the proposed methodology, the IEEE 34 and 123 bus test systems are used. The results obtained with both schemes are compared with the ones obtained by a Monte Carlo Simulation (MCS).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The experimental unit of measurement is a suitable technique to estimate the average character in evaluation, and experimentation should be well understood and executed, because the precision characterizes the quality of the inferences of the results. This research aimed to analyze the possibility to obtaining the quantity of fruit required for sampling of lychee plants, to determining the average mass of the fruits, with less sampling error. One hundred fruits were collected, in a hectare, in two cropping systems, conventional and organic, being one fruit per plant. From the data of fruit mass was used the Excel® to calculate the average fruit mass and number of fruits samples needed to represent the area of the producer. The results show that to achieve a sampling error of 10% for determining the average mass of fruit, 400 fruits should be collected for organic system and 370 for the conventional, while for 20% sampling error, it is necessary to collect 250 fruits per hectare in organic system and 220 in the conventional.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This text aims to identify the discursive relations and the mechanisms used by sources - discourses gathered at press and specialized sites - in composing of viewpoints presented about the religious education textbooks and, a result of that, of controversial relationship built thereafter. The theoretical foundation of this work rests largely on the concepts of global semantics and constitutive intermisunderstanding (MAINGUENEAU, 1997, 2008) and discursive heterogeneity (AUTHIER-REVUZ, 1990, 1998). The research corpus consisted of four texts, three of which were published in 2010 and another in 2011, two reports and two opinion articles about the subject. From our analysis, we could see the construction of a controversial relationship between a discursive formation that challenges the teaching of religion in Brazilian public education, on the grounds that benefit the Christian faith and, moreover, one that supports the continuation of this practice and consider it important for the formation of the student and also as a promoter of diversity and equality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The maximal oxygen uptake (VO2max) is the maximal quantity of energy that can be produced by the aerobic metabolism in certain time unity. It can be determined direct or indirectly by predictive equations. The objective of this study was to make a specific predictive equation to determine the VO 2max from boys aged 10-16 years-old. Forty-two boys underwent a treadmill running ergospirometric test, with the initial velocity set at 9 km/h, until voluntary exhaustion. By the multiple linear regression was possible to develop the following equation for the indirect determination of the VO 2max: VO2max (ml/min) = -1574.06 + (141.38 x Vpeak) + (48.34 * Body mass), with standard error of estimate = 191.5 ml/min (4.10 ml/kg/min) and coefficient of determination = 0.934. We suggest that this formula is appropriate to predict VO2max for this population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to investigate the possible influence of different levels of aerobic fitness (VO2MAX) on the parameters of the running anaerobic sprint test (RAST). Thirty-eight subjects (Age = 18.1 ± 2.5 years, Height = 173 ± 1 cm and Body mass = 65.1 ± 6.5 kg) were classified into two groups, low and high aerobic fitness (LAF: n = 22 and HAF: n = 16). The VO2MAX was determined by an incremental exercise performed until exhaustion. The RAST was composed of six maximal efforts of 35m separated by 10s passive recovery. The VO2MAX was significantly different between groups (LAF = 51.7 ± 1.9 mL.kg -1.min-1; HAF = 58.6 ± 3.1 mL.kg -1.min-1). The mean power (MP) was significantly higher in the LAF (552.7 ± 132.1 W) in relation to the HAF group (463.6 ± 132.8 W). The impulse (ImP) was significantly correlated with the VO 2MAX in HAF. It can be concluded that there is an indication that the aerobic metabolism exerts an influence on the completion of RAST.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo deste estudo foi determinar, em mesatenistas bem treinados, as aptidões aeróbia e anaeróbia. Participaram do presente estudo oito mesatenistas brasileiros treinados do sexo masculino (18±2 anos). Os sujeitos foram submetidos a um teste incremental específico para determinação do consumo pico de oxigênio (VO2PICO), intensidade associada ao VO2PICO (iVO2PICO) e do ponto de compensação respiratório (PCR) e a dois testes de esforço repetitivo, sendo o teste de RAST e o índice anaeróbio alático (IAA), para determinação dos índices anaeróbios. O VO2PICO correspondeu a 50,5±4,4ml kg-1 min-1 , a iVO2PICO a 52,1±9,6 bolas min-1 e o PCR a 44,9±8,0 bolas min-1. No RAST, a potência pico (PP) e a potência média (PM) relativa corresponderam a 9,0±1,3W kg-1 e 7,0±0,9W kg-1, respectivamente, enquanto que o IAA foi 1,14±0,51 mM/m s-1 . Esses valores de VO2PICO e dos parâmetros anaeróbios quando comparados a valores de outros esportes com raquetes caracterizaram que mesatenistas brasileiros treinados apresentam potência aeróbia moderada e potência anaeróbia é baixa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Artes - IA

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)