886 resultados para Lens testing
Resumo:
A major problem in developmental neurotoxicity (DNT) risk assessment is the lack of toxicological hazard information for most compounds. Therefore, new approaches are being considered to provide adequate experimental data that allow regulatory decisions. This process requires a matching of regulatory needs on the one hand and the opportunities provided by new test systems and methods on the other hand. Alignment of academically and industrially driven assay development with regulatory needs in the field of DNT is a core mission of the International STakeholder NETwork (ISTNET) in DNT testing. The first meeting of ISTNET was held in Zurich on 23-24 January 2014 in order to explore the concept of adverse outcome pathway (AOP) to practical DNT testing. AOPs were considered promising tools to promote test systems development according to regulatory needs. Moreover, the AOP concept was identified as an important guiding principle to assemble predictive integrated testing strategies (ITSs) for DNT. The recommendations on a road map towards AOP-based DNT testing is considered a stepwise approach, operating initially with incomplete AOPs for compound grouping, and focussing on key events of neurodevelopment. Next steps to be considered in follow-up activities are the use of case studies to further apply the AOP concept in regulatory DNT testing, making use of AOP intersections (common key events) for economic development of screening assays, and addressing the transition from qualitative descriptions to quantitative network modelling.
Resumo:
Different types of aerosolization and deagglomeration testing systems exist for studying the properties of nanomaterial powders and their aerosols. However, results are dependent on the specific methods used. In order to have well-characterized aerosols, we require a better understanding of how system parameters and testing conditions influence the properties of the aerosols generated. In the present study, four experimental setups delivering different aerosolization energies were used to test the resultant aerosols of two distinct nanomaterials (hydrophobic and hydrophilic TiO2). The reproducibility of results within each system was good. However, the number concentrations and size distributions of the aerosols created varied across the four systems; for number concentrations, e.g., from 10(3) to 10(6) #/cm(3). Moreover, distinct differences were also observed between the two materials with different surface coatings. The article discusses how system characteristics and other pertinent conditions modify the test results. We propose using air velocity as a suitable proxy for estimating energy input levels in aerosolization systems. The information derived from this work will be especially useful for establishing standard operating procedures for testing nanopowders, as well as for estimating their release rates under different energy input conditions, which is relevant for occupational exposure.
Resumo:
Many people regard the concept of hypothesis testing as fundamental to inferential statistics. Various schools of thought, in particular frequentist and Bayesian, have promoted radically different solutions for taking a decision about the plausibility of competing hypotheses. Comprehensive philosophical comparisons about their advantages and drawbacks are widely available and continue to span over large debates in the literature. More recently, controversial discussion was initiated by an editorial decision of a scientific journal [1] to refuse any paper submitted for publication containing null hypothesis testing procedures. Since the large majority of papers published in forensic journals propose the evaluation of statistical evidence based on the so called p-values, it is of interest to expose the discussion of this journal's decision within the forensic science community. This paper aims to provide forensic science researchers with a primer on the main concepts and their implications for making informed methodological choices.
Resumo:
A thorough literature review about the current situation on the implementation of eye lens monitoring has been performed in order to provide recommendations regarding dosemeter types, calibration procedures and practical aspects of eye lens monitoring for interventional radiology personnel. Most relevant data and recommendations from about 100 papers have been analysed and classified in the following topics: challenges of today in eye lens monitoring; conversion coefficients, phantoms and calibration procedures for eye lens dose evaluation; correction factors and dosemeters for eye lens dose measurements; dosemeter position and influence of protective devices. The major findings of the review can be summarised as follows: the recommended operational quantity for the eye lens monitoring is H p (3). At present, several dosemeters are available for eye lens monitoring and calibration procedures are being developed. However, in practice, very often, alternative methods are used to assess the dose to the eye lens. A summary of correction factors found in the literature for the assessment of the eye lens dose is provided. These factors can give an estimation of the eye lens dose when alternative methods, such as the use of a whole body dosemeter, are used. A wide range of values is found, thus indicating the large uncertainty associated with these simplified methods. Reduction factors from most common protective devices obtained experimentally and using Monte Carlo calculations are presented. The paper concludes that the use of a dosemeter placed at collar level outside the lead apron can provide a useful first estimate of the eye lens exposure. However, for workplaces with estimated annual equivalent dose to the eye lens close to the dose limit, specific eye lens monitoring should be performed. Finally, training of the involved medical staff on the risks of ionising radiation for the eye lens and on the correct use of protective systems is strongly recommended.
Resumo:
Invasive mold infections are life-threatening diseases for which appropriate antifungal therapy is crucial. Their epidemiology is evolving, with the emergence of triazole-resistant Aspergillus spp. and multidrug-resistant non-Aspergillus molds. Despite the lack of interpretive criteria, antifungal susceptibility testing of molds may be useful in guiding antifungal therapy. The standard broth microdilution method (BMD) is demanding and requires expertise. We assessed the performance of a commercialized gradient diffusion method (Etest method) as an alternative to BMD. The MICs or minimal effective concentrations (MECs) of amphotericin B, voriconazole, posaconazole, caspofungin, and micafungin were assessed for 290 clinical isolates of the most representative pathogenic molds (154 Aspergillus and 136 non-Aspergillus isolates) with the BMD and Etest methods. Essential agreements (EAs) within ±2 dilutions of ≥90% between the two methods were considered acceptable. EAs for amphotericin B and voriconazole were >90% for most potentially susceptible species. For posaconazole, the correlation was acceptable for Mucoromycotina but Etest MIC values were consistently lower for Aspergillus spp. (EAs of <90%). Excellent EAs were found for echinocandins with highly susceptible (MECs of <0.015 μg/ml) or intrinsically resistant (MECs of >16 μg/ml) strains. However, MEC determinations lacked consistency between methods for strains exhibiting mid-range MECs for echinocandins. We concluded that the Etest method is an appropriate alternative to BMD for antifungal susceptibility testing of molds under specific circumstances, including testing with amphotericin B or triazoles for non-Aspergillus molds (Mucoromycotina and Fusarium spp.). Additional study of molecularly characterized triazole-resistant Aspergillus isolates is required to confirm the ability of the Etest method to detect voriconazole and posaconazole resistance among Aspergillus spp.
Resumo:
We empirically applied the GrooFiWorld agent-based model (Puga-González et al. 2009) in a group of captive mangabeys (Cercocebus torquatus). We analysed several measurements related to aggression and affiliative patterns. The group adopted a combination of despotic and egalitarian behaviours resulting from the behavioural flexibility observed in the Cercopithecinae subfamily. Our study also demonstrates that the GrooFiWorld agent-based model can be extended to other members of the Cercopithecinae subfamily generating parsimonious hypotheses related to the social organization.
Resumo:
PURPOSE: To assess the agreement and repeatability of horizontal white-to-white (WTW) and horizontal sulcus-to-sulcus (STS) diameter measurements and use these data in combination with available literature to correct for interdevice bias in preoperative implantable collamer lens (ICL) size selection. DESIGN: Interinstrument reliability and bias assessment study. METHODS: A total of 107 eyes from 56 patients assessed for ICL implantation at our institution were included in the study. This was a consecutive series of all patients with suitable available data. The agreement and bias between WTW (measured with the Pentacam and BioGraph devices) and STS (measured with the HiScan device) were estimated. RESULTS: The mean spherical equivalent was -8.93 ± 5.69 diopters. The BioGraph measures of WTW were wider than those taken with the Pentacam (bias = 0.26 mm, P < .01), and both horizontal WTW measures were wider than the horizontal STS measures (bias >0.91 mm, P < .01). The repeatability (Sr) of STS measured with the HiScan was 0.39 mm, which was significantly reduced (Sr = 0.15 mm) when the average of 2 measures was used. Agreement between the horizontal WTW measures and horizontal STS estimates when bias was accounted for was г = 0.54 with the Pentacam and г = 0.64 with the BioGraph. CONCLUSIONS: Large interdevice bias was observed for WTW and STS measures. STS measures demonstrated poor repeatability, but the average of repeated measures significantly improved repeatability. In order to conform to the US Food and Drug Administration's accepted guidelines for ICL sizing, clinicians should be aware of and account for the inconsistencies between devices.
Resumo:
La dermatite irritative est décrite comme une réaction réversible, non immunologique caractérisée par des lésions d'aspect très variable, allant de la simple rougeur jusqu'à la formation de bulles voire d'une nécrose, accompagnée de prurit ou d'une sensation de brûlure suite à I' application d'une substance chimique. Le teste de prédiction d'irritation cutanée est traditionnellement depuis les années 1940 le Test de Draize. Ce test consiste en l'application d'une substance chimique sur une peau rasée de lapin pendant 4h et de regarder à 24h si des signes cliniques d'irritations sont présents. Cette méthode critiquable autant d'un point de vue éthique que qualitative reste actuellement le teste le plus utilisé. Depuis le début des années 2000 de nouvelles méthodes in vitro se sont développées tel que le model d'épiderme humain recombiné (RHE). Il s agit d'une multicouche de kératinocyte bien différencié obtenu depuis une culture de don d'ovocyte. Cependant cette méthode en plus d'être très couteuse n'obtient au mieux que 76% de résultat similaire comparé au test in vivo humain. Il existe donc la nécessité de développer une nouvelle méthode in vitro qui simulerait encore mieux la réalité anatomique et physiologique retrouvée in vivo. Notre objectif a été de développer cette nouvelle méthode in vitro. Pour cela nous avons travaillé avec de la peau humaine directement prélevée après une abdominoplastie. Celle ci après préparation avec un dermatome, un couteau dont la lame est réglable pour découper l'épaisseur souhaitée de peau, est montée dans un système de diffusion cellulaire. La couche cornée est alors exposée de manière optimale à 1 ml de la substance chimique testée pendant 4h. L'échantillon de peau est alors fixé dans du formaldéhyde pour permettre la préparation de lames standards d'hématoxyline et éosine. L'irritation est alors investiguée selon des critères histopathologiques de spongioses, de nécroses et de vacuolisations cellulaires. Les résultats de ce.tte première batterie de testes sont plus que prometteurs. En effet, comparé au résultat in vivo, nous obtenons 100% de concordance pour les 4 même substances testes irritantes ou non irritantes, ce qui est supérieur au model d épiderme humain recombiné (76%). De plus le coefficient de variation entre les 3 différentes séries est inférieur à 0.1 ce qui montre une bonne reproductibilité dans un même laboratoire. Dans le futur cette méthode va devoir être testée avec un plus grand nombre de substances chimiques et sa reproductibilité évaluée dans différents laboratoires. Mais cette première evaluation, très encourageante, ouvre des pistes précieuses pour l'avenir des tests irritatifs.
Resumo:
Bloodstream infections and sepsis are a major cause of morbidity and mortality. The successful outcome of patients suffering from bacteremia depends on a rapid identification of the infectious agent to guide optimal antibiotic treatment. The analysis of Gram stains from positive blood culture can be rapidly conducted and already significantly impact the antibiotic regimen. However, the accurate identification of the infectious agent is still required to establish the optimal targeted treatment. We present here a simple and fast bacterial pellet preparation from a positive blood culture that can be used as a sample for several essential downstream applications such as identification by MALDI-TOF MS, antibiotic susceptibility testing (AST) by disc diffusion assay or automated AST systems and by automated PCR-based diagnostic testing. The performance of these different identification and AST systems applied directly on the blood culture bacterial pellets is very similar to the performance normally obtained from isolated colonies grown on agar plates. Compared to conventional approaches, the rapid acquisition of a bacterial pellet significantly reduces the time to report both identification and AST. Thus, following blood culture positivity, identification by MALDI-TOF can be reported within less than 1 hr whereas results of AST by automated AST systems or disc diffusion assays within 8 to 18 hr, respectively. Similarly, the results of a rapid PCR-based assay can be communicated to the clinicians less than 2 hr following the report of a bacteremia. Together, these results demonstrate that the rapid preparation of a blood culture bacterial pellet has a significant impact on the identification and AST turnaround time and thus on the successful outcome of patients suffering from bloodstream infections.
Resumo:
Many educators and educational institutions have yet to integrate web-based practices into their classrooms and curricula. As a result, it can be difficult to prototype and evaluate approaches to transforming classrooms from static endpoints to dynamic, content-creating nodes in the online information ecosystem. But many scholastic journalism programs have already embraced the capabilities of the Internet for virtual collaboration, dissemination, and reader participation. Because of this, scholastic journalism can act as a test-bed for integrating web-based sharing and collaboration practices into classrooms. Student Journalism 2.0 was a research project to integrate open copyright licenses into two scholastic journalism programs, to document outcomes, and to identify recommendations and remaining challenges for similar integrations. Video and audio recordings of two participating high school journalism programs informed the research. In describing the steps of our integration process, we note some important legal, technical, and social challenges. Legal worries such as uncertainty over copyright ownership could lead districts and administrators to disallow open licensing of student work. Publication platforms among journalism classrooms are far from standardized, making any integration of new technologies and practices difficult to achieve at scale. And teachers and students face challenges re-conceptualizing the role their class work can play online.
Resumo:
The central goal of food safety policy in the European Union (EU) is to protect consumer health by guaranteeing a high level of food safety throughout the food chain. This goal can in part be achieved by testing foodstuffs for the presence of various chemical and biological hazards. The aim of this study was to facilitate food safety testing by providing rapid and user-friendly methods for the detection of particular food-related hazards. Heterogeneous competitive time-resolved fluoroimmunoassays were developed for the detection of selected veterinary residues, that is coccidiostat residues, in eggs and chicken liver. After a simplified sample preparation procedure, the immunoassays were performed either in manual format with dissociation-enhanced measurement or in automated format with pre-dried assay reagents and surface measurement. Although the assays were primarily designed for screening purposes providing only qualitative results, they could also be used in a quantitative mode. All the developed assays had good performance characteristics enabling reliable screening of samples at concentration levels required by the authorities. A novel polymerase chain reaction (PCR)-based assay system was developed for the detection of Salmonella spp. in food. The sample preparation included a short non-selective pre-enrichment step, after which the target cells were collected with immunomagnetic beads and applied to PCR reaction vessels containing all the reagents required for the assay in dry form. The homogeneous PCR assay was performed with a novel instrument platform, GenomEra™, and the qualitative assay results were automatically interpreted based on end-point time-resolved fluorescence measurements and cut-off values. The assay was validated using various food matrices spiked with sub-lethally injured Salmonella cells at levels of 1-10 colony forming units (CFU)/25 g of food. The main advantage of the system was the exceptionally short time to result; the entire process starting from the pre-enrichment and ending with the PCR result could be completed in eight hours. In conclusion, molecular methods using state-of-the-art assay techniques were developed for food safety testing. The combination of time-resolved fluorescence detection and ready-to-use reagents enabled sensitive assays easily amenable to automation. Consequently, together with the simplified sample preparation, these methods could prove to be applicable in routine testing.
Resumo:
Control on regional government budgets is important in a monetary union as lower tiers of government have fewer incentives to consolidate debt. According to the Fiscal Theory of the Price Level; unsustainable non-Ricardian fiscal policies eventually force monetary policy to adjust. Hence, uncoordinated and non-regulated regional fiscal policies would therefore threaten price stability for the monetary union as a whole. However, the union central bank is not without defense. A federal government that internalises the spillover effect of non-Ricardian fiscal policies on the price level can offset non-Ricardian regional fiscal policies. A federal government, which taxes and transfers resources between regions, may compensate for unsustainable regional fiscal policies so as to keep fiscal policy Ricardian on aggregate. Following Canzoneri et al. (2001), we test the validity of the Fiscal Theory of the Price Level for both federal and regional governments in Germany. We find evidence of a spillover effect of unsustainable policies on the price level for other Länder. However, the German federal government offsets this effect on the price level by running Ricardian policies. These results have implications for the regulation of fiscal policies in the EMU.