985 resultados para LOW-POTASSIUM DEXTRAN
Resumo:
Aim: To systematically review the literature investigating the incidence of fatal and or nonfatal low-speed vehicle run-over (LSVRO) incidents in children aged 0–15 years. Methods: The following databases were searched using specific search terms, from their date of conception up to June 2011: Cochrane Library, Medline, CINAHL, Embase, AMI, Sociological Abstracts, ERIC, PsycArticles, PsycInfo, Urban Studies and Planning; Australian Criminology Database; Dissertations and Thesis; Academic Research Library; Social Services Abstracts; Family and Society; Scopus; and Web of Science. A total of 128 articles were identified in the databases (33 found by hand searching). The title and abstract of these were read, and 102 were removed because they were not primary research articles relating to LSVRO-type injuries. Twenty-six articles were assessed against the inclusion (reporting population level incidence rates) and exclusion criteria, 19 of which were excluded, leaving a total of five articles for inclusion in the review. Findings: Five studies were identified that met the inclusion criteria. The incidence rate in nonfatal LSVRO events varied in the range of 7.09 to 14.79 per 100,000 and from 0.63 to 3.2 per 100,000 in fatal events. Discussion: Using International Classification of Diseases codes for classifying fatal or nonfatal LSVRO incidents is problematic as there is no specific code for LSVRO. The current body of research is void of a comprehensive secular population data analysis. Only with an improved spectrum of incidence rates will appropriate evaluation of this problem be possible, and this will inform nursing prevention interventions. The effect of LSVRO incidents is clearly understudied. More research is required to address incidence rates in relation to culture, environment, risk factors, car design, and injury characteristics. Conclusions: Thevlack of nursing research or policy around this area of injury, most often to children, indicates a field of inquiry and policy development that needs attention.
Resumo:
Ba(6-3x)Nd(8+2x)Ti(18)O(54) (BNTl14) is a high permittivity dielectric with low temperature coefficient (Tcf). Low coefficient of change of dielectric permittivity with temperature (Tcf) is an unusual materials property. The research is aimed at discovering how atomic structure relates to temperature coefficient. Sub-Ångström scanning transmission electron microscopy (STEM) is used to measure mixed occupancy of Nd and Ba in atomic columns. It was expected that phase separation would occur to accommodate mixing of dissimilar ions. However no evidence of phase separation was found. There is a good image match between experiment and high angle annular dark field (HAADF) simulation. Vacancies and excess Ba ions appear to be randomly arranged on the available sites which would result in distortion of TiO6 octahedra. The low Tcf may arise from TiO6 distortion.
Resumo:
Background Formalised predialysis care has been shown to extend the wellness of individuals with advanced chronic kidney disease, slow disease progression and increase the uptake of home dialysis. Predialysis care, incorporating multidisciplinary input is also vital in delaying the onset of end-stage kidney disease and reducing hospital admissions; thereby decreasing financial demands on health budgets. Predialysis care should include comprehensive information provision and predialysis education. This empowers patients to choose self-care strategies and therapies.
Resumo:
This thesis presents the development of a rapid, sensitive and reproducible spectroscopic method for the detection of TNT in forensic and environmental applications. Simple nano sensors prepared by cost effective methods were utilized as sensitive platforms for the detection of TNT by surface enhanced Raman spectroscopy. The optimization of the substrate and the careful selection of a suitable recognition molecule contributed to the significant improvements of sensitive and selective targeting over current detection methods. The work presented in this thesis paves the way for effective detection and monitoring of explosives residues in law enforcement and environmental health applications.
Resumo:
INTRODUCTION Although the high heritability of BMD variation has long been established, few genes have been conclusively shown to affect the variation of BMD in the general population. Extreme truncate selection has been proposed as a more powerful alternative to unselected cohort designs in quantitative trait association studies. We sought to test these theoretical predictions in studies of the bone densitometry measures BMD, BMC, and femoral neck area, by investigating their association with members of the Wnt pathway, some of which have previously been shown to be associated with BMD in much larger cohorts, in a moderate-sized extreme truncate selected cohort (absolute value BMD Z-scores = 1.5-4.0; n = 344). MATERIALS AND METHODS Ninety-six tag-single nucleotide polymorphism (SNPs) lying in 13 Wnt signaling pathway genes were selected to tag common genetic variation (minor allele frequency [MAF] > 5% with an r(2) > 0.8) within 5 kb of all exons of 13 Wnt signaling pathway genes. The genes studied included LRP1, LRP5, LRP6, Wnt3a, Wnt7b, Wnt10b, SFRP1, SFRP2, DKK1, DKK2, FZD7, WISP3, and SOST. Three hundred forty-four cases with either high or low BMD were genotyped by Illumina Goldengate microarray SNP genotyping methods. Association was tested either by Cochrane-Armitage test for dichotomous variables or by linear regression for quantitative traits. RESULTS Strong association was shown with LRP5, polymorphisms of which have previously been shown to influence total hip BMD (minimum p = 0.0006). In addition, polymorphisms of the Wnt antagonist, SFRP1, were significantly associated with BMD and BMC (minimum p = 0.00042). Previously reported associations of LRP1, LRP6, and SOST with BMD were confirmed. Two other Wnt pathway genes, Wnt3a and DKK2, also showed nominal association with BMD. CONCLUSIONS This study shows that polymorphisms of multiple members of the Wnt pathway are associated with BMD variation. Furthermore, this study shows in a practical trial that study designs involving extreme truncate selection and moderate sample sizes can robustly identify genes of relevant effect sizes involved in BMD variation in the general population. This has implications for the design of future genome-wide studies of quantitative bone phenotypes relevant to osteoporosis.
Resumo:
This technical report describes a Light Detection and Ranging (LiDAR) augmented optimal path planning at low level flight methodology for remote sensing and sampling Unmanned Aerial Vehicles (UAV). The UAV is used to perform remote air sampling and data acquisition from a network of sensors on the ground. The data that contains information on the terrain is in the form of a 3D point clouds maps is processed by the algorithms to find an optimal path. The results show that the method and algorithm are able to use the LiDAR data to avoid obstacles when planning a path from a start to a target point. The report compares the performance of the method as the resolution of the LIDAR map is increased and when a Digital Elevation Model (DEM) is included. From a practical point of view, the optimal path plan is loaded and works seemingly with the UAV ground station and also shows the UAV ground station software augmented with more accurate LIDAR data.
Resumo:
Malnutrition is a common problem in children with end-stage liver disease (ESLD), and accurate assessment of nutritional status is essential in managing these children. In a retrospective study, we compared nutritional assessment by anthropometry with that by body composition. We analyzed all consecutive measurements of total body potassium (TBK, n = 186) of children less than 3 years old with ESLD awaiting transplantation found in our database. The TBK values obtained by whole body counting of 40K were compared with reference TRK values of healthy children. The prevalence of malnutrition, as assessed by weight (weight Z score < -2) was 28%, which was significantly lower (chi-square test, p < 0.0001) than the prevalence of malnutrition (76%) assessed by TBK (< 90% of expected TRK for age). These results demonstrated that body weight underestimated the nutritional deficit and stressed the importance of measuring body composition as part of assessing nutritional status of children with ESLD.
Resumo:
Objective: To investigate measures aimed at defining the nutritional status of cystic fibrosis (CF) populations, this study compared standard anthropometric measurements and total body potassium (TBK) as indicators of malnutrition. Methods: Height, weight, and TBK measurements of 226 children with CF from Royal Children's Hospital, Brisbane, Australia, were analyzed. Z scores for height for age, weight for age, and weight for height were analyzed by means of the National Centre for Health Statistics reference. TBK was measured by means of whole body counting and compared with predicted TBK for age. Two criteria were evaluated with respect to malnutrition: (1) a z score < -2.0 and (2) a TBK for age <80% of predicted. Results: Males and females with CF had lower mean height-for-age and weight-for-age z scores than the National Centre for Health Statistics reference (P < .01), but mean weight-for-height z score was not significantly different. There were no significant gender differences. According to anthropometry, only 7.5% of this population were underweight and 7.6% were stunted. However, with TBK as an indicator of nutritional status, 29.9% of males and 22.0% of females were malnourished. Conclusion: There are large differences in the percentage of patients with CF identified as malnourished depending on whether anthropometry or body composition data are used as the nutritional indicator. At an individual level, weight-based indicators are not sensitive indicators of suboptimal nutritional status in CF, significantly underestimating the extent of malnutrition. Current recommendations in which anthropometry is used as the indicator of malnutrition in CF should be revised.
Resumo:
Background: The use of large-volume electrolyte balanced solutions as preparation for colonoscopy often results in poor patient compliance and acceptance. The tolerance, safety, and efficacy of high-versus low volume colon-cleansing methods as preparation for colonoscopy in children were compared by randomized operator-blinded trial. Methods: Twenty-nine children ages 3.6-14.6 years had either high-volume nasogastric balanced polyethylene glycol electrolyte lavage (20 ml/kg/h) until the effluent was clear (n = 15), or two oral doses of sodium phosphate solution (22.5-45 ml) separated by oral fluid intake (n = 14). Results: Both preparations were equally effective. The low-volume preparation was better tolerated and caused less discomfort that the high-volume preparation, judging by serial nurse observations. The incidence of abdominal symptoms, diarrhea, sleep disturbance, and vomiting was not significantly different between the two groups. Both groups had a small reduction in mean hematocrit and serum calcium levels. The sodium phosphate preparation caused increases in mean serum sodium concentrations from 140 to 145 mmol/L and serum phosphate concentrations from 1.41 to 2.53 mmol/L. Ten hours after the commencement of the preanesthetic fast, these concentrations had returned to normal. Conclusions: There are advantages in terms of tolerance, discomfort, and case of administration with acceptable colonic cleansing with the use of the less-invasive oral sodium phosphate low-volume colon-cleansing preparation in children. Safe use requires ensuring an adequate oral fluid intake during the preparation time and avoidance of use in patients with renal insufficiency.
Resumo:
In our earlier study, we have observed that hypokalemia in langur monkeys, following gossypol acetic acid (GAA) treatment (5 mg dose level) when used as an antispermatogenic agent, and potassium salt supplementation partially maintained body potassium level of the animals. The aims of the present investigation was to confirm further occurrence of hypokalemia in the monkey (comparatively at two higher dose levels) and the role of potassium salt in preventing occurrence of gossypol-induced hypokalemia. Highly purified gossypol acetic acid alone at two dose levels (7.5 and 10 mg/animal/day; oral) and in combination with potassium chloride (0.50 and 0.75 mg/animal/day; oral) was given for 180 days. Treatment with gossypol alone as well as with the supplementation of potassium salt resulted in severe oligospermia and azoospermia. Animals receiving gossypol alone showed significant potassium deficiency with signs of fatigue at both dose levels. Enhanced potassium loss through urine was found in potassium-deficient animals, whereas animals receiving gossypol acetic acid plus potassium salt showed normal serum potassium with a less significant increase in urine potassium level during treatment phases. Other parameters of the body remained within normal range except gradual and significant elevation in serum transaminases activity. The animals gradually returned to normalcy following 150 and 180 days of termination of the treatment.
Resumo:
We report the electrical conductivity between 2 and 300 K for LaNi1-xFexO3 across the composition-controlled metal-insulator (m-i) transition. Using a method first suggested by Mobius, we identify the critical concentration x(c) to be 0.3 for the m-i transition. The negative temperature coefficient of resistivity observed at low temperatures in the metallic phase follows a temperature dependence characteristic of disorder effects. The semiconducting compositions (x greater than or equal to 0.3) do not show a simple activation energy but exhibit variable-range hopping at high temperatures confirming that the m-i transition in this system is driven by increasing disorder effects.
Resumo:
An explicit near-optimal guidance scheme is developed for a terminal rendezvous of a spacecraft with a passive target in circular orbit around the earth. The thrust angle versus time profile for the continuous-thrust, constant-acceleration maneuver is derived, based on the assumption that the components of inertial acceleration due to relative position and velocity are negligible on account of the close proximity between the two spacecraft. The control law is obtained as a ''bilinear tangent law'' and an analytic solution to the state differential equations is obtained by expanding a portion of the integrand as an infinite series in time. A differential corrector method is proposed, to obtain real-time updates to the guidance parameters at regular time intervals. Simulation of the guidance scheme is carried out using the Clohessy-Wiltshire equations of relative motion as well as the inverse-square two-body equations of motion. Results for typical examples are presented.
Resumo:
Monitoring gas purity is an important aspect of gas recovery stations where air is usually one of the major impurities. Purity monitors of Katherometric type ate commercially available for this purpose. Alternatively, we discuss here a helium gas purity monitor based on acoustic resonance of a cavity at audio frequencies. It measures the purity by monitoring the resonant frequency of a cylindrical cavity filled with the gas under test and excited by conventional telephone transducers fixed at the ends. The use of the latter simplifies the design considerably. The paper discusses the details of the resonant cavity and the electronic circuit along with temperature compensation. The unit has been calibrated with helium gas of known purities. The unit has a response time of the order of 10 minutes and measures the gas purity to an accuracy of 0.02%. The unit has been installed in our helium recovery system and is found to perform satisfactorily.
Resumo:
D.C. electrical conductivity of polyaniline (33%,40%) blended with PMMA was measured from 5K to 300mK. The conductivity behaviour is consistent with fluctuation induced tunneling. Magneto-resistance (MR) was measured between 300K and 2K. From 20K to 2K, a large positive MR was observed. At 2K, for low magnetic fields (<1 Tesla), a deviation from the normal H-2 behaviour was observed.
Resumo:
Melancholic depressive patients referred for ECT were randomized to receive either low dose (n = 20) or high dose (n = 20) stimulus applied bifrontotemporally. The two stimulus groups were comparable on the clinical variables. The EEG seizure was recorded on two channels (right and left frontal), digitized, coded and analyzed offline without knowledge of ECT parameters. EEG seizure was of comparable duration in the two stimulus (high dose and low dose) groups. A new composite measure, Strength-Symmetry-Index (SSI), based on strength and symmetry of seizure EEG was computed using fractal geometry. The SSI of the early-seizure was higher in the high dose than in the low dose ECT group. In a stepwise, logistic regression model, this variable contributed to 65% with correct classification of high dose and low dose ECT seizures.