908 resultados para Indoor Location
Resumo:
People's interaction with the indoor environment plays a significant role in energy consumption in buildings. Mismatching and delaying occupants' feedback on the indoor environment to the building energy management system is the major barrier to the efficient energy management of buildings. There is an increasing trend towards the application of digital technology to support control systems in order to achieve energy efficiency in buildings. This article introduces a holistic, integrated, building energy management model called `smart sensor, optimum decision and intelligent control' (SMODIC). The model takes into account occupants' responses to the indoor environments in the control system. The model of optimal decision-making based on multiple criteria of indoor environments has been integrated into the whole system. The SMODIC model combines information technology and people centric concepts to achieve energy savings in buildings.
Resumo:
A physiological experiment was carried out in a naturally ventilated, non-HVAC indoor environment of a spacious experimental room. More than 300 healthy university students volunteered for this study. The purpose of the study was to investigate the human physiological indicators which could be used to characterise the indoor operative temperature changes in a building and their impact on human thermal comfort based on the different climatic characteristics people would experience in Chongqing, China. The study found that sensory nerve conduction velocity (SCV) could objectively provide a good indicator for assessment of the human response to changes in indoor operative temperatures in a naturally ventilated situation. The results showed that with the changes in the indoor operative temperatures, the changing trend in the nerve conduction velocity was basically the same as that of the skin temperature at the sensory nerve measuring segment (Tskin(scv)). There was good coherent consistency among the factors: indoor operative temperature, SCV and Tskin(scv) in a certain indoor operative temperature range. Through self-adaptation and self-feedback regulation, the human physiological indicators would produce certain adaptive changes to deal with the changes in indoor operative temperature. The findings of this study should provide the baseline data to inform guidelines for the development of thermal environment-related standards that could contribute to efficient use of energy in buildings in China.
Resumo:
This paper argues that transatlantic hybridity connects space, visual style and ideological point of view in British television action-adventure fiction of the 1960s–1970s. It analyses the relationship between the physical location of TV series production at Elstree Studios, UK, the representation of place in programmes, and the international trade in television fiction between the UK and USA. The TV series made at Elstree by the ITC and ABC companies and their affiliates linked Britishness with an international modernity associated with the USA, while also promoting national specificity. To do this, they drew on film production techniques that were already common for TV series production in Hollywood. The British series made at Elstree adapted versions of US industrial organization and television formats, and made programmes expected to be saleable to US networks, on the basis of British experiences in TV co-production with US companies and of the international cinema and TV market.
Resumo:
To ensure minimum loss of system security and revenue it is essential that faults on underground cable systems be located and repaired rapidly. Currently in the UK, the impulse current method is used to prelocate faults, prior to using acoustic methods to pinpoint the fault location. The impulse current method is heavily dependent on the engineer's knowledge and experience in recognising/interpreting the transient waveforms produced by the fault. The development of a prototype real-time expert system aid for the prelocation of cable faults is described. Results from the prototype demonstrate the feasibility and benefits of the expert system as an aid for the diagnosis and location of faults on underground cable systems.
Resumo:
We present a study of the geographic location of lightning affecting the ionospheric sporadic-E (Es) layer over the ionospheric monitoring station at Chilton, UK. Data from the UK Met Office's Arrival Time Difference (ATD) lightning detection system were used to locate lightning strokes in the vicinity of the ionospheric monitoring station. A superposed epoch study of this data has previously revealed an enhancement in the Es layer caused by lightning within 200km of Chilton. In the current paper, we use the same data to investigate the location of the lightning strokes which have the largest effect on the Es layer above Chilton. We find that there are several locations where the effect of lightning on the ionosphere is most significant statistically, each producing different ionospheric responses. We interpret this as evidence that there is more than one mechanism combining to produce the previously observed enhancement in the ionosphere.
Resumo:
This paper investigates the extent to which office activity contributes to travel-related CO2 emission. Using ‘end-user’ figures[1], travel accounts for 32% of UK CO2 emission (Commission for Integrated Transport, 2007) and commuting and business travel accounts for a fifth of transport-related CO2 emissions, equating to 6.4% of total UK emissions (Building Research Establishment, 2000). Figures from the Department for Transport (2006) report that 70% of commuting trips were made by car, accounting for 73% of all commuting miles travelled. In assessing the environmental performance of an office building, the paper questions whether commuting and business travel-related CO2 emission is being properly assessed. For example, are office buildings in locations that are easily accessible by public transport being sufficiently rewarded? The de facto method for assessing the environmental performance of office buildings in the UK is the Building Research Establishment’s Environmental Assessment Method (BREEAM). Using data for Bristol, this paper examines firstly whether BREEAM places sufficient weight on travel-related CO2 emission in comparison with building operation-related CO2 emission, and secondly whether the methodology for assigning credits for travel-related CO2 emission efficiency is capable of discerning intra-urban differences in location such as city centre and out-of-town. The results show that, despite CO2 emission per worker from building operation and travel being comparable, there is a substantial difference in the credit-weighting allocated to each. Under the current version of BREEAM for offices, only a maximum of 4% of the available credits can be awarded for ensuring the office location is environmentally sustainable. The results also show that all locations within the established city centre of Bristol will receive maximum BREEAM credits. Given the parameters of the test there is little to distinguish one city centre location from another and out of town only one office location receives any credits. It would appear from these results that the assessment method is not able to discern subtle differences in the sustainability of office locations