932 resultados para Incollaggi, Single-lap joint, Effetto di bordo, CFRP, Analisi numerica, FEM


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The title complex was synthesized and characterized by H-1, C-13, Sn-119 NMR and IR spectra. A single crystal X-ray diffraction study confirmed its molecular structure and revealed that 3,4,5-trimethoxy-benzoyl salicylahydrazone was a tridentate and approximately planar ligand. The complex crystallizes in the triclinic space group P1BAR with a = 9.208(3), b = 12.536(2), c = 12.187(4) angstrom, alpha = 113.12(2), beta = 90.58(2), gamma = 81.42(2), V = 1277.5(6) angstrom, Z = 2. The structure was refined to R = 0.033 and R(w) = 0.041 for 3944 observed independent reflections. The tin atom has a distorted trigonal bipyramidal coordination. The Sn-C bond lengths are 2.129(5) and 2.113(5) angstrom (av. 2.121(5) angstrom), the C-Sn-C angle is 123.3(2); the bond length between the tin atom and the chelating nitrogen is 2.173(3) angstrom. Two chain carbon atoms and the chelating nitrogen atom occupy the basal plane. The skeleton of two erect oxygen atoms and the tin atom is bent (O-Sn-O angle = 153.5(1)). In the complex, the ligand exists in the enol-form.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Capillary gas chromatographic enantiomer separation of some polar compounds, including alpha-phenylethylamine, styrene oxide, pyrethroid insecticides and other carboxylates, was investigated on modified cyclodextrin (CD) chiral stationary phases. The chiral stationary phases studied included permethylated beta-CD (PMBCD), heptakis (2,6-di-O-butyl-3-O-butyryl)-beta-CD (DBBBCD), heptakis (2,6-di-O-nonyl-3-O-trifluoroacetyl)-beta-CD (DNTBCD), the mixture of PMBCD and DBBBCD, and the mixture of PMBCD and DNTBCD. On the mixed chiral stationary phases containing the mixtures of derivatized cyclodextrins, enantiomer separation was improved significantly for some compounds as compared to the single cyclodextrin derivative chiral stationary phases, and synergistic effects were observed for some compounds on the mixed cyclodextrin derivative chiral stationary phases.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Lower Extremity Joint Arthroplasty (LEJA) surgery is an effective way to alleviate painful osteoarthritis. Unfortunately, these surgeries do not normalize the loading asymmetry during the single leg stance phase of gait. Therefore, we examined single leg balance in 234 TJA patients (75 hips, 65 knees, 94 ankles) approximately 12 months following surgery. Patients passed if they maintained single leg balance for 10s with their eyes open. Patients one year following total hip arthroplasty (THA-63%) and total knee arthroplasty (TKA-69%) had similar pass rates compared to a total ankle arthroplasty (TAA-9%). Patients following THA and TKA exhibit better unilateral balance in comparison with TAA patients. It may be beneficial to include a rigorous proprioception and balance training program in TAA patients to optimize functional outcomes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cyclo(L-Glu-L-Glu) has been crystallised in two different polymorphic forms. Both polymorphs are monoclinic, but form 1 is in space group P21 and form 2 is in space group C2. Raman scattering and FT-IR spectroscopic studies have been conducted for the N,O-protonated and deuterated derivatives. Raman spectra of orientated single crystals, solid-state and aqueous solution samples have also been recorded. The different hydrogen-bonding patterns for the two polymorphs have the greatest effect on vibrational modes with N&bond;H and C&dbond;O stretching character. DFT (B3-LYP/cc-pVDZ) calculations of the isolated cyclo(L-Glu-L-Glu) molecule predict that the minimum energy structure, assuming C2 symmetry, has a boat conformation for the diketopiperazine ring with the two L-Glu side chains being folded above the ring. The calculated geometry is in good agreement with the X-ray crystallographic structures for both polymorphs. Normal coordinate analysis has facilitated the band assignments for the experimental vibrational spectra. Copyright © 2009 John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The synovial fluid proteome in juvenile idiopathic arthritis was investigated to isolate joint-specific biomarkers that are expressed in patients displaying recurrent joint inflammation. To identify the synovial specific proteome, matched synovial fluid and plasma samples were subjected to protein separation by 2-dimension electrophoresis (2DE). Forty-three protein spots, overexpressed in the joint, were identified. Synovial fluids from children with single-event knee joint inflammation were then compared with a group with recurrent knee disease. Nine synovial specific proteins were significantly differentially expressed in the recurrent group. Proteolytic fragments of collagen X, fibrin beta-chain, and T-cell receptor alpha-region have been identified among this protein cluster. Putative biomarkers, overexpressed in the joint and differentially expressed in children with recurrent joint inflammation, have been identified. These proteins may play a significant role determining the pathological state within the chronically inflamed joint and influence disease progression in JIA. This is the first study of the synovial proteome in children.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper summarises some of the most recent work that has been done on nanoscale ferroelectrics as a result of a joint collaborative research effort involving groups in Queen's University Belfast, the University of Cambridge and the University of St. Andrews. Attempts have been made to observe fundamental effects of reduced size, and increasing morphological complexity, on ferroelectric behaviour by studying the functional response and domain characteristics in nanoscale single crystal material, whose size and morphology have been defined by Focused Ion Beam (FIB) patterning. This approach to nanoshape fabrication has allowed the following broad statements to be made: (i) in single crystal BaTiO3 sheets, permittivity and phase transition behaviour is not altered from that of bulk material down to a thickness of similar to 75 nm; (ii) in single crystal BaTiO3 sheets and nanowires changes in observed domain morphologies are consistent with large scale continuum modeling.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Toluene dioxygenase (TDO)-catalysed monooxygenation of methylsulfanylmethyl phenyl sulfide 1 and methylsulfanylmethyl 2-pyridyl sulfide 4, using whole cells of Pseudomonas putida UV4, occurred exclusively at the alkyl aryl sulfur centre to yield the alkyl aryl sulfoxides 2 and 5 respectively. These sulfoxides, accompanied by the dialkyl sulfoxides 3 and 6, were also obtained from naphthalene dioxygenase (NDO)-catalysed sulfoxidation of thioacetals 1 and 4 using intact cells of P. putida NCIMB 8859. Enzymatic oxidation of methyl benzyl sulfide 7, 2-phenyl-1,3-dithiane 19, and 2-phenyl-1,3-dithiolane 23, using TDO, gave the corresponding dialkyl sulfoxides 8, 20 and 24 as minor bioproducts. TDO-catalysed dioxygenation of the alkyl benzyl sulfides 7, 15 and 17 and the thioacetals 19 and 23, with P. putida UV4, yielded the corresponding enantiopure cis-dihydrodiols 9, 16, 18, 21 and 25 as major metabolites and cis-dihydrodiol sulfoxides 14, 22 and 26 as minor metabolites, resulting from a tandem trioxygenation of substrates 7, 19 and 23 respectively. Chemical oxidation, of the enantiopure cis-dihydrodiol sulfides 9, 16, 18 and 21 with dimethyldioxirane (DMD), gave separable mixtures of the corresponding pairs of cis-dihydrodiol sulfoxide diastereoisomers 14 and 27, 28 and 29, 30 and 31, 22 and 32. While dialkyl sulfoxide bioproducts 3, 6, 20 and 24 were of variable enantiopurity (27-greater than or equal to 98% ee), alkyl aryl monosulfoxides 2 and 5, cis-dihydrodiols 9, 16, 18, 21 and 25 and cis-dihydrodiol sulfoxide bioproducts 14, 22 and 26 were all single enantiomers (greater than or equal to 98% ee). The absolute configurations of the products, obtained from enzyme-catalysed (TDO and NDO) and chemical (DMD) oxidation methods, were determined by stereochemical correlation, circular dichroism, and X-ray crystallographic methods.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Synovial fluid is a potential source of novel biomarkers for many arthritic disorders involving joint inflammation, including juvenile idiopathic arthritis. We first compared the distinctive protein ‘fingerprints’ of local inflammation in synovial fluid with systemic profiles within matched plasma samples. The synovial fluid proteome at the time of joint inflammation was then evaluated across clinical subgroups to identify early disease associated proteins. We measured the synovial fluid and plasma proteomes using the two-dimensional fluorescence difference gel electrophoresis approach. Image analysis software was used to highlight the expression levels of joint and subgroup associated proteins across the study cohort (n = 32). A defined subset of 30 proteins had statistically significant differences (p < 0.05) between sample types such that synovial fluid could be differentiated from plasma. Furthermore distinctive synovial proteome expression patterns segregate patient subgroups. Protein expression patterns localized in the chronically inflamed joint therefore have the potential to identify patients more likely to suffer disease which will spread from a single joint to multiple joints. The proteins identified could act as criteria to prevent disease extension by more aggressive therapeutic intervention directed at an earlier stage than is currently possible.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This manuscript describes how motor behaviour researchers who are not at the same time expert roboticists may implement an experimental apparatus, which has the ability to dictate torque fields around a single joint on one limb or single joints on multiple limbs without otherwise interfering with the inherent dynamics of those joints. Such an apparatus expands the exploratory potential of the researcher wherever experimental distinction of factors may necessitate independent control of torque fields around multiple limbs, or the shaping of torque fields of a given joint independently of its plane of motion, or its directional phase within that plane. The apparatus utilizes torque motors. The challenge with torque motors is that they impose added inertia on limbs and thus attenuate joint dynamics. We eliminated this attenuation by establishing an accurate mathematical model of the robotic device using the Box-Jenkins method, and cancelling out its dynamics by employing the inverse of the model as a compensating controller. A direct measure of the remnant inertial torque as experienced by the hand during a 50 s period of wrist oscillations that increased gradually in frequency from 1.0 to 3.8 Hz confirmed that the removal of the inertial effect of the motor was effectively complete.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of hybrid materials including carbon fiber reinforced plastics (CFRPs) and lightweight metals such as titanium are increasing particularly in aerospace applications. Multi-material stacks require a number of holes for the assembly purposes. In this research, drilling trials have been carried out in CFRP, Ti-6Al-4V and CFRP/Ti-6Al-4V stack workpieces using AlTiN coated tungsten carbide drill bit. The effects of process parameters have been investigated. The thrust force, torque, burr formation, delamination, surface roughness and tool wear have been analyzed at various processing condition. The experimental results have shown that the thrust force, torque, burr formation and the average surface roughness increase with the increased feed rate and decrease with the increased cutting speed in drilling of Ti-6Al-4V. In drilling CFRP, delamination and the average surface roughness has similar tendency with the cutting parameters however thrust force and torque rises with the increased cutting speed. The results showed that after making 15 holes in CFRP/Ti-6Al-4V stack, measured thrust forces were increased by 20% in CFRP and by 45% in Ti-6Al-4V. Delamination was found to be much smaller in drilling of CFRP in stack from compared to drilling single CFRP. Tool life was significantly shortened in drilling of stack due to the combination of the wear mechanisms.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, the impact of multiple active eavesdroppers on cooperative single carrier systems with multiple relays and multiple destinations is examined. To achieve the secrecy diversity gains in the form of opportunistic selection, a two-stage scheme is proposed for joint relay and destination selection, in which, after the selection of the relay with the minimum effective maximum signal-to-noise ratio (SNR) to a cluster of eavesdroppers, the destination that has the maximum SNR from the chosen relay is selected. In order to accurately assess the secrecy performance, the exact and asymptotic expressions are obtained in closed-form for several security metrics including the secrecy outage probability, the probability of non-zero secrecy rate, and the ergodic secrecy rate in frequency selective fading. Based on the asymptotic analysis, key design parameters such as secrecy diversity gain, secrecy array gain, secrecy multiplexing gain, and power cost are characterized, from which new insights are drawn. Moreover, it is concluded that secrecy performance limits occur when the average received power at the eavesdropper is proportional to the counterpart at the destination. Specifically, for the secrecy outage probability, it is confirmed that the secrecy diversity gain collapses to zero with outage floor, whereas for the ergodic secrecy rate, it is confirmed confirm that its slope collapses to zero with capacity ceiling.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Differentiation between septic and aseptic loosening of joint replacements is essential for successful revision surgery, but reliable markers for the diagnosis of low-grade infection are lacking. The present study was performed to assess intra-articular and systemic levels of antimicrobial peptides and proinflammatory cytokines as diagnostic markers for periprosthetic joint infection. Methods: Fifteen consecutive patients with staphylococcal periprosthetic joint infections and twenty control patients with aseptic loosening of total hip and knee replacements were included in this prospective, single-center, controlled clinical trial. Expression of the antimicrobial peptides human β-defensin-2 (HBD-2), human β-defensin-3 (HBD-3), and cathelicidin LL-37 (LL-37) was determined by ELISA (enzyme-linked immunosorbent assay) in serum and joint aspirates. Proinflammatory cytokines were assessed in serum and joint aspirates with use of cytometric bead arrays. C-reactive protein in serum, microbiology, and histopathology of periprosthetic tissue served as the “gold standard” for the diagnosis of infection. Results: The antimicrobial peptides HBD-3 and LL-37 were significantly elevated in joint aspirates from patients with periprosthetic joint infection compared with patients with aseptic loosening, and the area under the curve (AUC) in a receiver operating characteristic curve analysis was equal to 0.745 and 0.875, respectively. Additionally, significant local increases in the proinflammatory cytokines interleukin (IL)-1β, IL-4, IL-6, IL-17A, interferon (IFN)-γ, and tumor necrosis factor (TNF)-α were observed to be associated with infection. Logistic regression analysis indicated that the combination of an antimicrobial peptide with another synovial fluid biomarker improved diagnostic accuracy; the AUC value was 0.916 for LL-37 and IL-4, 0.895 for LL-37 and IL-6, 0.972 for HBD-3 and IL-4, and 0.849 for HBD-3 and IL-6. In contrast, the only antimicrobial peptides and cytokines in serum that showed a significant systemic increase in association with infection were HBD-2, IL-4, and IL-6 (all of which had an AUC value of <0.75). Conclusions: The present study showed promising results for the use of antimicrobial peptides and other biomarkers in synovial fluid for the diagnosis of periprosthetic joint infection, and analysis of the levels in synovial fluid was more accurate than analysis of serum.