835 resultados para Improved equipment


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The popularity of wireless local area networks (WLANs) has resulted in their dense deployment in many cities around the world. The increased interference among different WLANs severely degrades the throughput achievable. This problem has been further exacerbated by the limited number of frequency channels available. An improved distributed and dynamic channel assignment scheme that is simple to implement and does not depend on the knowledge of the throughput function is proposed in this work. It also allows each access point (AP) to asynchronously switch to the new best channel. Simulation results show that our proposed scheme converges much faster than similar previously reported work, with a reduction in convergence time and channel switches as much as 77.3% and 52.3% respectively. When it is employed in dynamic environments, the throughput improves by up to 12.7%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many photovoltaic inverter designs make use of a buck based switched mode power supply (SMPS) to produce a rectified sinusoidal waveform. This waveform is then unfolded by a low frequency switching structure to produce a fully sinusoidal waveform. The Cuk SMPS could offer advantages over the buck in such applications. Unfortunately the Cuk converter is considered to be difficult to control using classical methods. Correct closed loop design is essential for stable operation of Cuk converters. Due to these stability issues, Cuk converter based designs often require stiff low bandwidth control loops. In order to achieve this stable closed loop performance, traditional designs invariably need large, unreliable electrolytic capacitors. In this paper, an inverter with a sliding mode control approach is presented which enables the designer to make use of the Cuk converters advantages, while ameliorating control difficulties. This control method allows the selection of passive components based predominantly on ripple and reliability specifications while requiring only one state reference signal. This allows much smaller, more reliable non-electrolytic capacitors to be used. A prototype inverter has been constructed and results obtained which demonstrate the design flexibility of the Cuk topology when coupled with sliding mode control.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A revised Bayesian algorithm for estimating surface rain rate, convective rain proportion, and latent heating profiles from satellite-borne passive microwave radiometer observations over ocean backgrounds is described. The algorithm searches a large database of cloud-radiative model simulations to find cloud profiles that are radiatively consistent with a given set of microwave radiance measurements. The properties of these radiatively consistent profiles are then composited to obtain best estimates of the observed properties. The revised algorithm is supported by an expanded and more physically consistent database of cloud-radiative model simulations. The algorithm also features a better quantification of the convective and nonconvective contributions to total rainfall, a new geographic database, and an improved representation of background radiances in rain-free regions. Bias and random error estimates are derived from applications of the algorithm to synthetic radiance data, based upon a subset of cloud-resolving model simulations, and from the Bayesian formulation itself. Synthetic rain-rate and latent heating estimates exhibit a trend of high (low) bias for low (high) retrieved values. The Bayesian estimates of random error are propagated to represent errors at coarser time and space resolutions, based upon applications of the algorithm to TRMM Microwave Imager (TMI) data. Errors in TMI instantaneous rain-rate estimates at 0.5°-resolution range from approximately 50% at 1 mm h−1 to 20% at 14 mm h−1. Errors in collocated spaceborne radar rain-rate estimates are roughly 50%–80% of the TMI errors at this resolution. The estimated algorithm random error in TMI rain rates at monthly, 2.5° resolution is relatively small (less than 6% at 5 mm day−1) in comparison with the random error resulting from infrequent satellite temporal sampling (8%–35% at the same rain rate). Percentage errors resulting from sampling decrease with increasing rain rate, and sampling errors in latent heating rates follow the same trend. Averaging over 3 months reduces sampling errors in rain rates to 6%–15% at 5 mm day−1, with proportionate reductions in latent heating sampling errors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Improved Stratospheric and Mesospheric Sounder (ISAMS) is designed to measure the Earths middle atmosphere in the range of 4.6 to 16.6 micorns. This paper considers all the coated optical elements in two radiometric test channels. (Analysis of the spectral response will be presented as a seperate paper at this symposium, see Sheppard et al). Comparisons between the compued spectral performance and measurements from actual coatings will be discussed: These will include substrate absorption simulations. The results of environmental testing (durability and stability) are included, together with details of coating deposition and monitoring conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

1. Closed Ecological Systems (CES) are small manmade ecosystems which do not have any material exchange with the surrounding environment. Recent ecological and technological advances enable successful establishment and maintenance of CES, making them a suitable tool for detecting and measuring subtle feedbacks and mechanisms. 2. As a part of an analogue (physical) C cycle modelling experiment, we developed a non-intrusive methodology to control the internal environment and to monitor atmospheric CO2 concentration inside 16 replicated CES. Whilst maintaining an air-tight seal of all CES, this approach allowed for access to the CO2 measuring equipment for periodic re-calibration and repairs. 3. To ensure reliable cross-comparison of CO2 observations between individual CES units and to minimise the cost of the system, only one CO2 sampling unit was used. An ADC BioScientific OP-2 (open-path) analyser mounted on a swinging arm was passing over a set of 16 measuring cells. Each cell was connected to an individual CES with air continuously circulating between them. 4. Using this setup, we were able to continuously measure several environmental variables and CO2 concentration within each closed system, allowing us to study minute effects of changing temperature on C fluxes within each CES. The CES and the measuring cells showed minimal air leakage during an experimental run lasting, on average, 3 months. The CO2 analyser assembly performed reliably for over 2 years, however an early iteration of the present design proved to be sensitive to positioning errors. 5. We indicate how the methodology can be further improved and suggest possible avenues where future CES based research could be applied.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The major component of skeletal muscle is the myofibre. Genetic intervention inducing over-enlargement of myofibres beyond a certain threshold through acellular growth causes a reduction in the specific tension generating capacity of the muscle. However the physiological parameters of a genetic model that harbours reduced skeletal muscle mass have yet to be analysed. Genetic deletion of Meox2 in mice leads to reduced limb muscle size and causes some patterning defects. The loss of Meox2 is not embryonically lethal and a small percentage of animals survive to adulthood making it an excellent model with which to investigate how skeletal muscle responds to reductions in mass. In this study we have performed a detailed analysis of both late foetal and adult muscle development in the absence of Meox2. In the adult, we show that the loss of Meox2 results in smaller limb muscles that harbour reduced numbers of myofibres. However, these fibres are enlarged. These myofibres display a molecular and metabolic fibre type switch towards a more oxidative phenotype that is induced through abnormalities in foetal fibre formation. In spite of these changes, the muscle from Meox2 mutant mice is able to generate increased levels of specific tension compared to that of the wild type.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three main changes to current risk analysis processes are proposed to improve their transparency, openness, and accountability. First, the addition of a formal framing stage would allow interested parties, experts and officials to work together as needed to gain an initial shared understanding of the issue, the objectives of regulatory action, and alternative risk management measures. Second, the scope of the risk assessment is expanded to include the assessment of health and environmental benefits as well as risks, and the explicit consideration of economic- and social-impacts of risk management action and their distribution. Moreover approaches were developed for deriving improved information from genomic, proteomic and metabolomic profiling methods and for probabilistic modelling of health impacts for risk assessment purposes. Third, in an added evaluation stage, interested parties, experts, and officials may compare and weigh the risks, costs, and benefits and their distribution. As part of a set of recommendations on risk communication, we propose that reports on each stage should be made public.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper first points out the important fact that the rectangle formulas of continuous convolution discretization, which was widely used in conventional digital deconvolution algorithms, can result in zero-time error. Then, an improved digital deconvolution equation is suggested which is equivalent to the trapezoid formulas of continuous convolution discretization and can overcome the disadvantage of conventional equation satisfactorily. Finally, a simulation in computer is given, thus confirming the theoretical result.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

LaMn and LaCo doped barium hexaferrites of formula Ba(1-x)LaxFe(12-x)MxO19 (M=Mn, Co) (x=0.05 to 0.40) were prepared with an improved co-precipitation/molten salt method. For the synthesis, aqueous solutions of the appropriate metal chlorides were prepared in the ratio required except that the initial mole ratio of Fe and dopants to Ba was chosen to be 11:1, and then mixed with excess Na2CO3. The solutions were then cooled, filtered off, dried, then mixed with KCl flux, and heated at 450 degrees C and for 2 h. The temperature was then raised to 950 degrees C and kept for 4 h, then cooled. This new synthesis method, which employs a lower temperature and shorter reaction time, gives products with improved crystallinity and purity while the saturation magnetization and coercivity values are comparable with those synthesized via the high temperature method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The simulation and development work that has been undertaken to produce a signal equaliser used to improve the data rates from oil well logging instruments is presented. The instruments are lowered into the drill bore hole suspended by a cable which has poor electrical characteristics. The equaliser described in the paper corrects for the distortions that occur from the cable (dispersion and attenuation) with the result that the instrument can send data at 100 K.bits/second down its own suspension cable of 12 Km in length. The use of simulation techniques and tools were invaluable in generating a model for the distortions and proved to be a useful tool when site testing was not available.