747 resultados para IONIC LIQUID ELECTROLYTE


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Clenbuterol is a β2 agonist agent with anabolic properties given by the increase in the muscular mass in parallel to the decrease of the body fat. For this reason, the use of clenbuterol is forbidden by the World Anti-Doping Agency (WADA) in the practice of sport. This compound is of particular interest for anti-doping authorities and WADA-accredited laboratories due to the recent reporting of risk of unintentional doping following the eating of meat contaminated with traces of clenbuterol in some countries. In this work, the development and the validation of an ultra-high pressure liquid chromatography coupled to electrospray ionization tandem mass spectrometry (UHPLC-ESI-MS/MS) method for the quantification of clenbuterol in human urine is described. The analyte was extracted from urine samples by liquid-liquid extraction (LLE) in basic conditions using tert butyl-methyl ether (TBME) and analyzed by UHPLC-MS/MS with a linear gradient of acetonitrile in 9min only. The simple and rapid method presented here was validated in compliance with authority guidelines and showed a limit of quantification at 5pg/mL and a linearity range from 5pg/mL to 300pg/mL. Good trueness (85.8-105%), repeatability (5.7-10.6% RSD) and intermediate precision (5.9-14.9% RSD) results were obtained. The method was then applied to real samples from eighteen volunteers collecting urines after single oral doses administration (1, 5 and 10μg) of clenbuterol-enriched yogurts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Un dels problemes associats a la remeiació de contaminants hidròfobs és la seva poca disponibilitat. Es considera que un contaminant està disponible quan roman a la fase líquida del medi, ja sigui solubilitzat o en forma d’emulsió. Els surfactants són substàncies anfifíliques que promouen la transferència de compostos hidròfobs de la fase sòlida a la líquida. En aquest estudi s’escull el pirè com a representant dels hidrocarburs aromàtics policíclics i tres surfactants no iònics: un àmpliament citat a la bibliografia científica (Tween 80) i dos comercials (Gold Crew, BS-400). L’estudi es fa amb tres mescles d’argila i sorra amb diferents proporcions. La concentració micel·lar crítica (CMC) s’assoleix abans en sòls amb poc contingut en argila. L’eficiència dels surfactants està estretament relacionada amb la proporció d’argila i sorra. A concentracions molt per sobre de la CMC no s’observa una relació entre l’eficiència i la quantitat d’argila. El Tween 80 ha donat millors resultats que el Gold Crew i el BS-400, sense que aquest darrer no hagi presentat desadsorció de pirè.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Therapeutic drug monitoring (TDM) may contribute to optimizing the efficacy and safety of antifungal therapy because of the large variability in drug pharmacokinetics. Rapid, sensitive, and selective laboratory methods are needed for efficient TDM. Quantification of several antifungals in a single analytical run may best fulfill these requirements. We therefore developed a multiplex ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method requiring 100 μl of plasma for simultaneous quantification within 7 min of fluconazole, itraconazole, hydroxyitraconazole, posaconazole, voriconazole, voriconazole-N-oxide, caspofungin, and anidulafungin. Protein precipitation with acetonitrile was used in a single extraction procedure for eight analytes. After reverse-phase chromatographic separation, antifungals were quantified by electrospray ionization-triple-quadrupole mass spectrometry by selected reaction monitoring detection using the positive mode. Deuterated isotopic compounds of azole antifungals were used as internal standards. The method was validated based on FDA recommendations, including assessment of extraction yields, matrix effect variability (<9.2%), and analytical recovery (80.1 to 107%). The method is sensitive (lower limits of azole quantification, 0.01 to 0.1 μg/ml; those of echinocandin quantification, 0.06 to 0.1 μg/ml), accurate (intra- and interassay biases of -9.9 to +5% and -4.0 to +8.8%, respectively), and precise (intra- and interassay coefficients of variation of 1.2 to 11.1% and 1.2 to 8.9%, respectively) over clinical concentration ranges (upper limits of quantification, 5 to 50 μg/ml). Thus, we developed a simple, rapid, and robust multiplex UPLC-MS/MS assay for simultaneous quantification of plasma concentrations of six antifungals and two metabolites. This offers, by optimized and cost-effective lab resource utilization, an efficient tool for daily routine TDM aimed at maximizing the real-time efficacy and safety of different recommended single-drug antifungal regimens and combination salvage therapies, as well as a tool for clinical research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Images obtained from high-throughput mass spectrometry (MS) contain information that remains hidden when looking at a single spectrum at a time. Image processing of liquid chromatography-MS datasets can be extremely useful for quality control, experimental monitoring and knowledge extraction. The importance of imaging in differential analysis of proteomic experiments has already been established through two-dimensional gels and can now be foreseen with MS images. We present MSight, a new software designed to construct and manipulate MS images, as well as to facilitate their analysis and comparison.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Es presenten els resultats experimentals obtinguts durant l’estudi sistemàtic realitzat de la preparació electroquímica de puntes de tungstè per al Microscopi d’Efecte Túnel (STM), fent servir dos electròlits: KOH i NaOH. L’estudi sobre la morfologia, longitud de la punta i radi de curvatura de la punta en funció del voltatge aplicat i les concentracions de l’electròlit es descriu al capítol 3. La caracterització de les puntes es va dur a terme, per una part, mitjançant un microscòpic electrònic de rastreig (SEM) i per l’altre banda, amb el ús de les puntes obtingudes al STM. En resumen, els resultats mostren que ambdós electròlits permeten obtenir puntes que es poden fer servir amb èxit per l’obtenció d’imatges amb l’STM. Les millors puntes són aquelles que s’obtenen dins de rangs de concentracions d’electròlit baixes, entre valor de 10 a 15% en pes pel NaOH i entre 10 i 20% pel KOH i rangs de voltatge entre 3 a 7 V pel NaOH i 4 a 8 V pel KOH. S’observa que es requereixen temps d’atac electroquímic menors fent servir com a electròlit NaOH. S’estudia, en el capítol 4, el tractament que requereix la punta per tal d’eliminar les impureses de la seva superfície. Es realitzen diferents proves amb tres mètodes de neteja: (1) tractament químic, (2) bombardeig iònic i (3) tractament tèrmic de recuit. En el capítol 5 del projecte s’analitzen les imatges d’una mostra d’or, Au(110), d’estructura coneguda, amb el microscopi d’efecte túnel STM) del laboratori fent servir les puntes obtingudes sota les condicions considerades òptimes. El resultat confirma el bon comportament de les puntes obtingudes sota les condicions descrites en els capítols anteriors i establert una pauta a seguir per obtenir puntes d’una manera senzilla i reproduïble.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A mathematical model is developed to analyse the combined flow and solidification of a liquid in a small pipe or two-dimensional channel. In either case the problem reduces to solving a single equation for the position of the solidification front. Results show that for a large range of flow rates the closure time is approximately constant, and the value depends primarily on the wall temperature and channel width. However, the ice shape at closure will be very different for low and high fluxes. As the flow rate increases the closure time starts to depend on the flow rate until the closure time increases dramatically, subsequently the pipe will never close.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

How much water we really need depends on water functions and the mechanisms of daily water balance regulation. The aim of this review is to describe the physiology of water balance and consequently to highlight the new recommendations with regard to water requirements. Water has numerous roles in the human body. It acts as a building material; as a solvent, reaction medium and reactant; as a carrier for nutrients and waste products; in thermoregulation; and as a lubricant and shock absorber. The regulation of water balance is very precise, as a loss of 1% of body water is usually compensated within 24 h. Both water intake and water losses are controlled to reach water balance. Minute changes in plasma osmolarity are the main factors that trigger these homeostatic mechanisms. Healthy adults regulate water balance with precision, but young infants and elderly people are at greater risk of dehydration. Dehydration can affect consciousness and can induce speech incoherence, extremity weakness, hypotonia of ocular globes, orthostatic hypotension and tachycardia. Human water requirements are not based on a minimal intake because it might lead to a water deficit due to numerous factors that modify water needs (climate, physical activity, diet and so on). Water needs are based on experimentally derived intake levels that are expected to meet the nutritional adequacy of a healthy population. The regulation of water balance is essential for the maintenance of health and life. On an average, a sedentary adult should drink 1.5 l of water per day, as water is the only liquid nutrient that is really essential for body hydration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The metasomatism observed in the oceanic and continental lithosphere is generally interpreted to represent a continuous differentiation process forming anhydrous and hydrous veins plus a cryptic enrichment in the surrounding peridotite. In order to constrain the mechanisms of vein formation and potentially clarify the nature and origin of the initial metasomatic agent, we performed a series of high-pressure experiments simulating the liquid line of descent of a basanitic magma differentiating within continental or mature oceanic lithosphere. This series of experiments has been conducted in an end-loaded piston cylinder apparatus starting from an initial hydrous ne-normative basanite at 1.5 GPa and temperature varying between 1,250 and 980°C. Near-pure fractional crystallization process was achieved in a stepwise manner in 30°C temperature steps and starting compositions corresponding to the liquid composition of the previous, higher-temperature glass composition. Liquids evolve progressively from basanite to peralkaline, aluminum-rich compositions without significant SiO2 variation. The resulting cumulates are characterized by an anhydrous clinopyroxene + olivine assemblage at high temperature (1,250-1,160°C), while at lower temperature (1,130-980°C), hydrous cumulates with dominantly amphibole + minor clinopyroxene, spinel, ilmenite, titanomagnetite and apatite (1,130-980°C) are formed. This new data set supports the interpretation that anhydrous and hydrous metasomatic veins could be produced during continuous differentiation processes of primary, hydrous alkaline magmas at high pressure. However, the comparison between the cumulates generated by the fractional crystallization from an initial ne-normative liquid or from hy-normative initial compositions (hawaiite or picrobasalt) indicates that for all hydrous liquids, the different phases formed upon differentiation are mostly similar even though the proportions of hydrous versus anhydrous minerals could vary significantly. This suggests that the formation of amphibole-bearing metasomatic veins observed in the lithospheric mantle could be linked to the differentiation of initial liquids ranging from ne-normative to hy-normative in composition. The present study does not resolve the question whether the metasomatism observed in lithospheric mantle is a precursor or a consequence of alkaline magmatism; however, it confirms that the percolation and differentiation of a liquid produced by a low degree of partial melting of a source similar or slightly more enriched than depleted MORB mantle could generate hydrous metasomatic veins interpreted as a potential source for alkaline magmatism by various authors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cuticular hydrocarbons of larvae of individual strains of the Anopheles gambiae sensu stricto were investigated using gas liquid chromatography. Biomedical discriminant analysis involving multivariate statistics suggests that there was clear hydrocarbon difference between the Gambian(G3), the Nigerian (16CSS and, its malathion resistant substrain, REFMA) and the Tanzanian (KWA) strains. The high degree of segregation (95%) in hydrocarbons among the four strains investigated indicates that further analysis is needed to enable understanding of hydrocarbon variation in samples of An. gambiae especially from areas where these populations co-exist.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Previous studies showed that two groups of Trypanosoma cruzi clonal genotypes named clonet 20 and clonet 39 were predominant in Triatoma infestans, the unique vector of Chagas disease in Bolivia. These groups of clones correspond to distinct genetic clusters. These clonets were detected in T. infestans and Rhodnius pictipes fecal samples before isolation and after culture by kDNA PCR (polymerase chain rreaction) and hybridization of the amplified products with clonet specific kDNA probes named 20 and 39 as previously reported. Forty eight T. infestans and three R. pictipes infected insects captured at random in different Bolivian departments were proceeded. As previously reported the direct identification of the two major clonets in fecal samples allowed the detection of abundant mixed infections: 41% in the original sample, however after culture, only 6% of mixed infections were detected. Among the 21 parasite stocks isolated from digestive tracts where mixed infections were initially detected (clonet 20 + 39) clonet 20 alone was detected in 81% of them. This result clearly showed that the culture step selected clonet 20 parasites over those belonging to clonet 39. The taxonomic status of the isolated stocks was also confirmed by isoenzyme typing, and correlation was observed between clustering topology and hybridization patterns with the probes 20 and 39.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Systematic asymptotic methods are used to formulate a model for the extensional flow of a thin sheet of nematic liquid crystal. With no external body forces applied, the model is found to be equivalent to the so-called Trouton model for Newtonian sheets (and fi bers), albeit with a modi fied "Trouton ratio". However, with a symmetry-breaking electric field gradient applied, behavior deviates from the Newtonian case, and the sheet can undergo fi nite-time breakup if a suitable destabilizing field is applied. Some simple exact solutions are presented to illustrate the results in certain idealized limits, as well as sample numerical results to the full model equations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The case of a Moroccan woman, age 25, who came into the emergency department with clinical tetany, is presented. She had experienced muscle spasms and paresthaesia of the upper limb over the previous few days. She had also experienced major diarrhoea for the previous 3 weeks. Investigations revealed a severe electrolyte disorder.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The occurrence of electrolyte disorders as hypocalcemia and/or hyponatremia is an uncommon event in preeclampsia, which can be the sign of serious situation, with potentially unfavourable consequences for the mother and her foetus. Hyponatremia in the setting of preeclampsia is an indicator of severity, and requires the understanding of the etiologic mechanisms to initiate an appropriate treatment. Indeed the often-considered fluid restriction is rarely a treatment option for pregnant women. Hypocalcemia is a complication that must be monitored when a treatment with high doses of intravenous magnesium sulphate is introduced. In this context, hypocalcemia must be sought, with the exclusion of other etiologies as vitamin D deficiency, hypoparathyroidism or renal and extrarenal loss of calcium. A replacement therapy, intravenous or oral according to circumstances, should be considered in case of severe or symptomatic hypocalcemia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The response of Arabidopsis to stress caused by mechanical wounding was chosen as a model to compare the performances of high resolution quadrupole-time-of-flight (Q-TOF) and single stage Orbitrap (Exactive Plus) mass spectrometers in untargeted metabolomics. Both instruments were coupled to ultra-high pressure liquid chromatography (UHPLC) systems set under identical conditions. The experiment was divided in two steps: the first analyses involved sixteen unwounded plants, half of which were spiked with pure standards that are not present in Arabidopsis. The second analyses compared the metabolomes of mechanically wounded plants to unwounded plants. Data from both systems were extracted using the same feature detection software and submitted to unsupervised and supervised multivariate analysis methods. Both mass spectrometers were compared in terms of number and identity of detected features, capacity to discriminate between samples, repeatability and sensitivity. Although analytical variability was lower for the UHPLC-Q-TOF, generally the results for the two detectors were quite similar, both of them proving to be highly efficient at detecting even subtle differences between plant groups. Overall, sensitivity was found to be comparable, although the Exactive Plus Orbitrap provided slightly lower detection limits for specific compounds. Finally, to evaluate the potential of the two mass spectrometers for the identification of unknown markers, mass and spectral accuracies were calculated on selected identified compounds. While both instruments showed excellent mass accuracy (<2.5ppm for all measured compounds), better spectral accuracy was recorded on the Q-TOF. Taken together, our results demonstrate that comparable performances can be obtained at acquisition frequencies compatible with UHPLC on Q-TOF and Exactive Plus MS, which may thus be equivalently used for plant metabolomics.