872 resultados para Hand-held devices


Relevância:

20.00% 20.00%

Publicador:

Resumo:

STUDY DESIGN: Prospective neurophysiological study. OBJECTIVE: To identify and quantify the neurophysiological effects of interspinous distraction during spine surgery for lumbar spinal stenosis (LSS). SUMMARY OF BACKGROUND DATA: Interspinous devices have been introduced as an alternative treatment of LSS in selected patients aiming at obtaining indirect decompression. Nevertheless, there is no data on the immediate neurophysiological effect of distraction. METHODS: Thirty patients with LSS undergoing decompression (14 at single level, 16 at multiple levels) were enrolled, resulting in a total of 48 levels to be analyzed. Before decompression, calibrated incremental distraction simulating interspinous device implantation of 8, 10, 12, 14, and 16 mm was performed. Intraoperative motor evoked potentials were acquired before any distraction, during distraction at each incremental value and after bilateral decompression. We evaluated relative changes of motor evoked potentials normalized to hand muscles and related them to the number of affected levels, LSS radiological severity based on the A to D grading, lordosis, and disc height. RESULTS: For single-level disease, 8-mm distraction and open decompression yielded similar improvement in motor evoked potentials not only in levels with morphological grades A or B, but also in levels with morphological grades C or D (i.e., severe or extreme stenosis) (P = 0.32). In contrast, distraction superior to 8 mm was less effective (P ≤ 0.05). In multiple-level stenosis, decompression was significantly more effective than any degree of distraction (P < 0.001). No correlation of those results to disc height or lordosis was observed. Using χ trend test to analyze the effect of distraction, a linear trend favoring moderate over severe stenotic morphology was observed (P = 0.0349). CONCLUSION: Interspinous distraction of 8 mm is sufficient to replicate electrophysiological improvements obtained during full decompression even in severe single-level stenosis but not in multilevel disease. Interspinous distraction has therefore an immediately measurable neurophysiological effect. Level of Evidence: 4.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Attorney General’s Consumer Protection Division receives hundreds of calls and consumer complaints every year. Follow these tips to avoid unexpected expense and disappointments. This record is about: The Drive to Destroy: Removing data from computer hard drives, storage devices & wireless phones

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This report discusses the asphalt pavement recycling project designated Project HR-188 in Kossuth County, Iowa. Specific objectives were: (a) to determine the effectiveness of drum mixing plant modifications designed to control air pollution within limits specified by the Iowa Department of Environmental Quality; (b) to assess the impact of varying the proportions of recycled and virgin aggregates, (c) to assess the impact of varying the production rate of the plant, and (d) to assess the impact of varying the mixing temperature. The discussion includes information on the proposed use of research funds, project location and description, the project planning conference, plan development, bid letting, asphalt plant configuration, actual plant operation, why this method is successful, probable process limitations, pollution results, recycled pavement test results, and the cost of virgin vs. recycled asphalt pavements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Portable (roll-out) stop signs are used at school crossings in over 300 cities in Iowa. Their use conforms to the Code of Iowa, although it is not consistent with the provisions of the Manual on Uniform Traffic Control Devices adopted for nationwide application. A survey indicated that most users in Iowa believe that portable stop signs provide effective protection at school crossings, and favor their continued use. Other non-uniform signs that fold or rotate to display a STOP message only during certain hours are used at school crossings in over 60 cities in Iowa. Their use does not conform to either the Code of Iowa or the Manual on Uniform Traffic Control Devices. Users of these devices also tend to favor their continued use. A survey of other states indicated that use of temporary devices similar to those used in Iowa is not generally sanctioned. Some unsanctioned use apparently occurs in several states, however. A different type of portable stop sign for school crossings is authorized and widely used in one state. Portable stop signs similar to those used in Iowa are authorized in another state, although their use is quite limited. A few reports in the literature reviewed for this research discussed the use of portable stop signs. The authors of these reports uniformly recommended against the use of portable or temporary traffic control devices. Various reasons for this recommendation were given, although data to support the recommendation were not offered. As part of this research, field surveys were conducted at 54 locations in 33 communities where temporary stop control devices were in use at school crossings. Research personnel observed the obedience to stop control and measured the vehicular delay incurred. Stopped delay averaged 1.89 seconds/entering vehicle. Only 36.6 percent of the vehicles were observed to come to a complete stop at the study locations controlled by temporary stop control devices. However, this level of obedience does not differ from that observed at intersections controlled by permanent stop signs. Accident experience was compiled for 76 intersections in 33 communities in Iowa where temporary stop signs were used and, for comparative purposes, at 76 comparable intersections having other forms of control or operating without stop control. There were no significant differences in accident experience An economic analysis of vehicle operating costs, delay costs, and other costs indicated that temporary stop control generated costs only about 12 percent as great as permanent stop control for a street having a school crossing. Midblock pedestrian-actuated signals were shown to be cost effective in comparison with temporary stop signs under the conditions of use assumed. Such signals could be used effectively at a number of locations where temporary stop signs are being used. The results of this research do not provide a basis for recommending that use of portable stop signs be prohibited. However, erratic patterns of use of these devices and inadequate designs suggest that improved standards for their use are needed. Accordingly, nine recommendations are presented to enhance the efficiency of vehicular flow at school crossings, without causing a decline in the level of pedestrian protection being afforded.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The design of satisfactory supporting and expansion devices for highway bridges is a problem which has concerned bridge design engineers for many years. The problems associated with these devices have been emphasized by the large number of short span bridges required by the current expanded highway program of expressways and interstate highways. The initial objectives of this investigation were: (1) To review and make a field study of devices used for the support of bridge superstructures and for provision of floor expansion; (2) To analyze the forces or factors which influence the design and behavior of supporting devices and floor expansion systems; and (3) To ascertain the need for future research particularly on the problems of obtaining more economical and efficient supporting and expansion devices, and determining maximum allowable distance between such devices. The experimental portion was conducted to evaluate one of the possible simple and economical solutions to the problems observed in the initial portion. The investigation reported herein is divided into four major parts or phases as follows: (1) A review of literature; (2) A survey by questionnaire of design practice of a number of state highway departments and consulting firms; (3) Field observation of existing bridges; and, (4) An experimental comparison of the dynamic behavior of rigid and elastomeric bearings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To analyze the atmosphere inside incubators regarding alcoholic solvent such as isopropanol or ethanol which are commonly used in hand disinfecting solutions. Design: Observational. Setting: The third level neonatal unit of the Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland. Patients: Nine neonates with median (range) gestational age of 29 4/7 (25 5/7-39 0/7) weeks and birth weight of 960 (550-3050) grams. All neonates were inside incubators. Interventions: Alcoholic vapors inside incubators were directly and cumulatively measured by photoionisation and gas chromatography respectively after absorption on a charcoal sampling tube. Results: Eleven studies (mean study time: 230 ± 19 minutes) were performed. Highly variable isopropanol/ethanol concentrations profiles were found inside incubators. Peak value for isopropanol was 1982 part per million and for ethanol was 906 part per million. Conclusions: Incubators' inner atmosphere can be highly polluted by alcohol vapors. To reduce them staff should respect long evaporation time between hands disinfection and manipulations inside incubators. The use of an ethanol-based disinfecting solution, because of its short evaporation time, could be favored. As alcohol vapor toxicity for neonate remains largely unknown, further studies could be welcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chronic hand eczema is a frequent cause of consultation. In Europe and Switzerland, it's one of the main reasons for patients to interrupt their profession. The etiology is pluri-factorial. Atopic patients are more likely predisposed. Pruritus, associated to pain and bleeding, is intense. Psychosocial consequences are huge, making this illness to an important public health problem. Topical treatment and UV-light are the main therapeutical strategy but the results are often disappointing. Recently, alitretinoine (9-cis retinoic acid) became the treatment of second choice with good response, allowing patients to preserve a good quality of life and their job.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The extra session of the 1840 legislative assembly listing all of the territorial laws of Iowa. The dates of approval of the acts are listed after each one and a brief index is included. This is the 1902 reprint by the Historical Department of Iowa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Interventional paediatric and congenital cardiology is expanding at a rapid pace. Validated techniques (such as aortic or pulmonary valve dilatations and occlusion of persistent ductus arteriosus and atrial septal defects) are improving thanks to the use of smaller introducers and sheaths, low-profile balloons and novel devices. Moreover, catheter-based interventions have emerged as an attractive alternative to surgery in other fields: pulmonary valve replacement, balloon and stent implantation for native and recurrent coarctation, and percutaneous closure of ventricular septal defects. On the other hand, percutaneous interventions in the paediatric population may be limited by patient size or the anatomy of the defect. Hybrid approaches involving both cardiac interventionists and surgeons are being developed to overcome these limitations. Based on a better understanding of cardiac development, fetal cardiac interventions are being attempted in order to alter the history of severe obstructive lesions. Finally, some interventional procedures still carry a low success rate-for example, pulmonary vein stenosis, even with the use of conventional stents. Biodegradable stents and devices are being developed and may find an application in this setting as well as in others. The purpose of this review is to highlight the advances in paediatric interventional cardiology since the beginning of the third millennium.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The commemoration of the Fiftieth Anniversary of the Constitution which was adopted by the people of Iowa in 1857 was in itself a notable event. It has become a part of the history of our Commonwealth. The program, which was presented under the auspices of The State Historical Society of Iowa on the nineteenth, twentieth, twenty-first, and twenty-second of March, 1907, at Iowa City, Iowa, in the Hall of Liberal Arts, was carried out fully in every detail.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La désinfection des mains avant d'effectuer des soins est un acte indispensable en médecine clinique pour limiter le risque de transmission de germes. Après utilisation des produits désinfectants mis à disposition dans les services de soins, il se dégage une odeur alcoolique forte et désagréable, liée directement aux alcools antimicrobiens des solutions. Une étude a montré qu'une exposition aiguë et brève aux vapeurs d'éthanol et isopropanol chez des enfants prématurés pouvait être mise en relation avec des changements hémodynamiques au niveau de la zone olfactive orbito-frontale [1]. Aucune norme réglementant les concentrations de vapeurs d'éthanol ou isopropanol auxquelles les nouveau-nés peuvent être exposés n'existe. Cette thèse avait pour but d'étudier l'exposition des nouveaux nés soignés dans des incubateurs à des vapeurs d'alcool (éthanol et isopropanol). Elle était composée de 2 parties qui ont été publiées dans 2 articles différents et qui représentent le travail de doctorat [2-3]. La 1ère partie était une étude observationnelle d'une série de cas [2], Des mesures des concentrations des vapeurs d'alcool ont été effectuées auprès de 9 nouveau-nés soignés dans des incubateurs de même modèle au sein de l'unité de néonatologie du Centre Hospitalier Universitaire Vaudois à Lausanne. Sur 4 heures, les concentrations instantanées et moyennes ont été mesurées par deux techniques (photoionisation et respectivement chromatographic après absorption sur charbon actif). Onze analyses ont été effectuées en 2004-2005. Elles ont révélé des taux très variables d'éthanol et d'isopropanol dans les incubateurs (avec des valeurs maximales de 1982 ppm pour l'isopropanol et 906 ppm pour l'éthanol) correspondant aux introduction de mains fraîchement désinfectées dans les isolettes. Les concentrations moyennes variaient entre 9.8 ppm et plus de 61 ppm pour l'éthanol et < 0.01 ppm et 119 ppm pour l'isopropanol. La 2e partie a été réalisée en collaboration avec le PD Dr D. Vernez de l'Institut Universitaire Romand de Santé au Travail [3], Un modèle théorique prédictif des concentrations alcooliques dans des incubateurs pour nouveau-nés a été développé. Des séries de mesures standardisées des variations des concentrations alcooliques dans un incubateur sans patient ont été effectuées en changeant trois variables: 1) le renouvellement de l'air dans l'incubateur en variant le nombre de portes ouvertes, 2) la quantité de solution alcoolique versée sur les mains avant de les introduire dans l'incubateur 3) le temps de séchage des mains après désinfection et avant de les introduire dans l'incubateur. La modélisation a permis de décrire la cinétique des concentrations d'alcool dans les incubateurs et d'évaluer les pistes potentielles pour diminuer les risques d'exposition des nouveau-nés à ces vapeurs dans leurs incubateurs. En conclusion, la 1 ère partie a mis en évidence, pour la première fois, que des nouveau- nés soignés en incubateurs peuvent être exposés à des vapeurs d'alcool. Comme il η y a aucune norme d'exposition pour cette population et que les seules limites d'exposition existantes sont destinées à des travailleurs adultes, aucune conclusion précise ne peut être avancée sur les risques toxicologiques. L'exposition à des vapeurs polluantes d'un nouveau-né à terme ou prématuré, en plein développement neuro-sensoriel, devrait toutefois, à priori, être évitée. La 2ème partie permet de proposer des pistes pratiques pour diminuer les concentrations des vapeurs d'alcool dans les incubateurs: respecter le temps de séchage des mains après leur désinfection et avant de les introduire dans les isolettes et/ou préférer un désinfectant alcoolique à faible temps d'évaporation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The treatment of writer's cramp, a task-specific focal hand dystonia, needs new approaches. A deficiency of inhibition in the motor cortex might cause writer's cramp. Transcranial direct current stimulation modulates cortical excitability and may provide a therapeutic alternative. In this randomized, double-blind, sham-controlled study, we investigated the efficacy of cathodal stimulation of the contralateral motor cortex in 3 sessions in 1 week. Assessment over a 2-week period included clinical scales, subjective ratings, kinematic handwriting analysis, and neurophysiological evaluation. Twelve patients with unilateral dystonic writer's cramp were investigated; 6 received transcranial direct current and 6 sham stimulation. Cathodal transcranial direct current stimulation had no favorable effects on clinical scales and failed to restore normal handwriting kinematics and cortical inhibition. Subjective worsening remained unexplained, leading to premature study termination. Repeated sessions of cathodal transcranial direct current stimulation of the motor cortex yielded no favorable results supporting a therapeutic potential in writer's cramp.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Les systèmes d'assistance ventriculaire sont apparus durant la dernière décade comme une approche thérapeutique efficace du traitement de l'insuffisance cardiaque terminale, en particulier dans le contexte de manque de donneurs d'organes. Néanmoins, et ceci malgré les progrès techniques majeurs, les taux de complications restent élevés et sont en partie liés à la configuration géométrique, en particulier le site d'implantation de la cannule de sortie à l'aorte thoracique. Bien que l'anastomose à l'aorte descendante permette une chirurgie moins invasive, les bénéfices de cette technique sont toujours controversés, comparée à la méthode standard de l'aorte ascendante, en raison du risque thrombo-embolique possiblement augmenté et des modifications hémodynamiques induites au niveau de l'arc aortique. Dans ce travail, nous comparons in silico en terme de débit et pression les deux possibilités anastomotiques. Nous développons un réseau de modèles mathématiques unidimensionnels, et l'appliquons à diverses situations cliniques, pour différents stades d'insuffisance cardiaque et de vitesses de rotation de la machine. Les données initiales sont obtenues grâce à un modèle OD (c'est-à-dire qui dépend uniquement du temps mais pas de l'espace) du système cardiovasculaire comprenant une assistance circulatoire, validé avec des données cliniques. Les simulations réalisées montrent que les deux méthodes sont similaires, en terme de débit et courbes de pression, ceci pour tous les cas cliniques étudiés. Ces résultats numériques soutiennent la possibilité d'utiliser la technique d'anastomose à l'aorte thoracique descendante, permettant une chirurgie moins invasive. Sur un plan plus fondamental, le système cardiovasculaire peut être simulé par le biais de multiples modèles de niveau de complexité différents, au prix d'un coût computationnel toujours plus élevé. Nous évaluons les avantages de modèles géométriques à plusieurs échelles (uni- et tridimensionnelle) avec données provenant de patients, comparés à des modèles simplifiés. Les résultats montrent que ces modèles de dimensions hétérogènes apportent un bénéfice important en terme de ressources de calcul, tout en conservant une précision acceptable. En conclusion, ces résultats encourageant montrent la relevance des études numériques dans le domaine médical, tant sur le plan fondamental et la compréhension des mécanismes physiopathologiques, que sur le plan applicatif et le développement de nouvelles thérapeutiques.