964 resultados para Fixed effect
Resumo:
Background Total hip arthroplasty carried out using cemented modular-neck implants provides the surgeon with greater intra-operative flexibility and allows more controlled stem positioning. Methods In this study, finite element models of a whole femur implanted with either the Exeter or with a new cemented modular-neck total hip arthroplasty (separate, neck and stem components) were developed. The changes in bone and cement mantle stress/strain were assessed for varying amounts of neck offset and version angle for the modular-neck device for two simulated physiological load cases: walking and stair climbing. Since the Exeter is the gold standard for polished cemented total hip arthroplasty stem design, bone and cement mantle stresses/strains in the modular-neck finite element models were compared with finite element results for the Exeter. Findings For the two physiological load cases, stresses and strains in the bone and cement mantle were similar for all modular-neck geometries. These results were comparable to the bone and cement mechanics surrounding the Exeter. These findings suggest that the Exeter and the modular neck device distribute stress to the surrounding bone and cement in a similar manner. Interpretation It is anticipated that the modular-neck device will have a similar short-term clinical performance to that of the Exeter, with the additional advantages of increased modularity.
Resumo:
Background: Specialised disease management programmes for chronic heart failure (CHF) improve survival, quality of life and reduce healthcare utilisation. The overall efficacy of structured telephone support or telemonitoring as an individual component of a CHF disease management strategy remains inconclusive. Objectives: To review randomised controlled trials (RCTs) of structured telephone support or telemonitoring compared to standard practice for patients with CHF in order to quantify the effects of these interventions over and above usual care for these patients. Search strategy: Databases (the Cochrane Central Register of Controlled Trials (CENTRAL), Database of Abstracts of Reviews of Effects (DARE) and Health Technology Assessment Database (HTA) on The Cochrane Library, MEDLINE, EMBASE, CINAHL, AMED and Science Citation Index Expanded and Conference Citation Index on ISI Web of Knowledge) and various search engines were searched from 2006 to November 2008 to update a previously published non-Cochrane review. Bibliographies of relevant studies and systematic reviews and abstract conference proceedings were handsearched. No language limits were applied. Selection criteria: Only peer reviewed, published RCTs comparing structured telephone support or telemonitoring to usual care of CHF patients were included. Unpublished abstract data was included in sensitivity analyses. The intervention or usual care could not include a home visit or more than the usual (four to six weeks) clinic follow-up. Data collection and analysis: Data were presented as risk ratio (RR) with 95% confidence intervals (CI). Primary outcomes included all-cause mortality, all-cause and CHF-related hospitalisations which were meta-analysed using fixed effects models. Other outcomes included length of stay, quality of life, acceptability and cost and these were described and tabulated. Main results: Twenty-five studies and five published abstracts were included. Of the 25 full peer-reviewed studies meta-analysed, 16 evaluated structured telephone support (5613 participants), 11 evaluated telemonitoring (2710 participants), and two tested both interventions (included in counts). Telemonitoring reduced all-cause mortality (RR 0.66, 95% CI 0.54 to 0.81, P < 0.0001) with structured telephone support demonstrating a non-significant positive effect (RR 0.88, 95% CI 0.76 to 1.01, P = 0.08). Both structured telephone support (RR 0.77, 95% CI 0.68 to 0.87, P < 0.0001) and telemonitoring (RR 0.79, 95% CI 0.67 to 0.94, P = 0.008) reduced CHF-related hospitalisations. For both interventions, several studies improved quality of life, reduced healthcare costs and were acceptable to patients. Improvements in prescribing, patient knowledge and self-care, and New York Heart Association (NYHA) functional class were observed. Authors' conclusions: Structured telephone support and telemonitoring are effective in reducing the risk of all-cause mortality and CHF-related hospitalisations in patients with CHF; they improve quality of life, reduce costs, and evidence-based prescribing.
Resumo:
This study investigated the Kinaesthetic Fusion Effect (KFE) first described by Craske and Kenny in 1981. The current study did not replicate these findings. Participants did not perceive any reduction in the sagittal separation of a button pressed by the index finger of one arm and a probe touching the other, following repeated exposure to the tactile stimuli present on both unseen arms. This study’s failure to replicate the widely-cited KFE as described by Craske et al. (1984) suggests that it may be contingent on several aspects of visual information, especially the availability of a specific visual reference, the role of instructions regarding gaze direction, and the potential use of a line of sight strategy when referring felt positions to an interposed surface. In addition, a foreshortening effect was found; this may result from a line-of-sight judgment and represent a feature of the reporting method used. The transformed line of sight data were regressed against the participant reported values, resulting in a slope of 1.14 (right arm) and 1.11 (left arm), and r > 0.997 for each. The study also provides additional evidence that mis-perceptions of the mediolateral position of the limbs specifically their separation and consistent with notions of Gestalt grouping, is somewhat labile and can be influenced by active motions causing touch of one limb by the other. Finally, this research will benefit future studies that require participants to report the perceived locations of the unseen limbs.
Resumo:
Raman microprobe spectra of the clay mineral Wyoming SWy-2-sodium montmorillonite intercalated with the surfactants, methyltrioctadecylammonium bromide (TOMA) dimethyldiotadecylammonium bromide (DODMA) and octadecyl-trimethylammonium bromide (ODTMA), have been measured in the CH2 stretching region at external pressures up to ~40 kbar with the aid of a diamond-anvil cell. In the case of the intercalated clays containing TOMA and DODMA, the Raman data afford evidence for gauche to trans conformational changes in the orientation of the CH2 chains in the surfactants with increasing pressure. These conformational changes are reversed completely upon the release of pressure.
Resumo:
The effect of thermal radiation on a steady two-dimensional natural convection laminar flow of viscous incompressible optically thick fluid along a vertical flat plate with streamwise sinusoidal surface temperature has been investigated in this study. Using the appropriate variables; the basic governing equations are transformed to convenient form and then solved numerically employing two efficient methods, namely, Implicit finite difference method (IFD) together with Keller box scheme and Straight forward finite difference (SFFD) method. Effects of the variation of the physical parameters, for example, conduction-radiation parameter (Planck number), surface temperature parameter, and the amplitude of the surface temperature, are shown on the skin friction and heat transfer rate quantitatively are shown numerically. Velocity and temperature profiles as well as streamlines and isotherms are also presented and discussed for the variation of conduction-radiation parameter. It is found that both skin-friction and rate of heat transfer are enhanced considerably by increasing the values of conduction radiation parameter, Rd.
Resumo:
Laminar magnetohydrodynamic (MHD) natural convection flow from an isothermal sphere immersed in a fluid with viscosity proportional to linear function of temperature has been studied. The governing boundary layer equations are transformed into a non-dimensional form and the resulting nonlinear system of partial differential equations are reduced to convenient form which are solved numerically by two very efficient methods, namely, (i) Implicit finite difference method together with Keller box scheme and (ii) Direct numerical scheme. Numerical results are presented by velocity and temperature distribution, streamlines and isotherms of the fluid as well as heat transfer characteristics, namely the local skin-friction coefficients and the local heat transfer rate for a wide range of magnetohydrodynamic paramagnet and viscosity-variation parameter.