997 resultados para Filtros ativos de potência
Resumo:
Pós-graduação em Engenharia Elétrica - FEB
Resumo:
Pós-graduação em Engenharia de Produção - FEB
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aim of this study was to examine changes on anaerobic power after competitive period in professional soccer players. Twenty five male was evaluated before (PRE) and after (POS) competitive period. To assess anaerobic power was used running based on anaerobic sprint test (RAST), which were determined the maximum power (MAXP), medium power (MEDP), minimum power (MINP) and fatigue index (FI). The test was performed in the first (PRE) and the last (POS) training session of competitive period, wich lasted 20 weeks. There were no significant difference (p>0,05) in POS condition compared to PRE condition on MAXP (10,70 ± 0,95 vs 10,83 ± 0,87), MINP (8,48 ± 0,92 vs 8,28 ± 0,76), MEDP (9,52 ± 0,83 vs 9,41 ± 0,61) and FI (22,73 ± 7,48 vs 25,53 ± 8,79). There was no significant change on anaerobic power after a competitive period wich lasted 20 weeks in professional soccer players.
Resumo:
This paper presents the development and the main results for an interleaved boost rectifier operating as a special input power stage for a trolleybus type vehicle, allowing its feeding by alternate current (AC) or direct current (DC) distribution power systems. When feeding with two wires (single phase) alternate current distribution system, the converter accomplish active power factor correction, providing a relatively sinusoidal current with low total harmonic distortion (THD) and fully complying with IEC 61000-3-4 standards. In addition, a management control system promotes the required automatic operation changes for the proposed rectifier when the vehicle is changing from the DC distribution power system to the AC distribution power system and vice-versa, keeping its original electrical DC system characteristics for the adjustable speed driver sub-system. The main experimental results for a prototype rated at 150kW are presented, considering its application for a trolleybus with DC adjustable speed driver, demonstrating the proposed converter benefits and the possibility of AC feeding system for trolleybus type vehicle.
Resumo:
Apesar de pouco explorado, a prática de atividade física promove redução da Pressão Intraocular (PIO). O objetivo foi verificar o efeito de diferentes tipos de exercício na PIO. Quinze voluntários foram submetidos a 3 sessões de 30min de exercícios resistidos (3 x 8 repetições a 80%1RM), aeróbio contínuo (60% da Frequência Cardíaca de Reserva [FCR]), aeróbio intervalado (2min a 50% alternando com 1min a 80% da FCR). PIO foi mensurada antes (M1), durante (M2-15min), imediatamente após a sessão (M3) e na recuperação (5min [R1] e 10min [R2]). Como procedimento estatístico foi utilizado ANOVA. Houve redução da PIO nas 3 sessões de exercício (M2 e M3). Na recuperação, PIO permaneceu reduzida após 5min (R1) em todos os modelos. Porém, aos 10min (R2) estava menor que M1 apenas na sessão de exercício intervalado. Os resultados sugerem que o exercício intervalado é mais efetivo que o contínuo e resistido na redução da PIO.
Resumo:
Estudos sugerem que a atividade física promove redução e contribui no controle da Pressão Intraocular (PIO). O objetivo foi verificar o efeito de diferentes exercícios na PIO. Quinze voluntários foram submetidos a 3 sessões de 30min de exercícios resistidos (3 x 8 repetições a 80%1RM), aeróbio contínuo (60% da Frequência Cardíaca de Reserva [FCR]), aeróbio intervalado (2min a 50% alternando com 1min a 80% da FCR). PIO foi mensurada antes (M1), durante (M2-15min), imediatamente após a sessão (M3) e na recuperação (5min [R1] e 10min [R2]). Adotou-se ANOVA para tratamento estatístico. Houve redução significativa da PIO nas 3 sessões de exercício (M2 e M3). Na recuperação, PIO permaneceu reduzida após 5min (R1) em todos os modelos. Porém, aos 10min (R2) estava menor que M1 apenas na sessão de exercício intervalado. Os resultados sugerem que o exercício intervalado pode ser mais efetivo que o contínuo e resistido na diminuição da PIO.
Resumo:
Para a realização deste experimento, foram utilizados um rebolo de óxido de alumínio instalado em uma retificadora plana, um dispositivo em forma de balança juntamente com o sensor de deslocamento, um sistema de aquisição de sinais e um dressador de ponta única de diamante. O processamento digital dos dados foi obtido com o software Matlab. Nos ensaios, foram aplicados diferentes graus de recobrimento e profundidade de dressagem e comparada a agressividade obtida. A partir dos dados resultantes, os parâmetros RMS, DPO e DPKS mostraram-se bons indicadores para a operação. Também ficou comprovado que para recondicionar e definir novas características para o rebolo é necessária a remoção de 120 um. Do estudo do espectro do dinal de EA, notou-se que não há componentes hormônicas com frequência superior a 200 KHz.
Resumo:
Pós-graduação em Direito - FCHS
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The use of pesticides to manage pest problems in agriculture has become a common practice around the world. Pesticides consist in chemical substances or biological agents that act preventing, destroying, repelling or mitigating the damage caused by pests in agriculture. In order to a successful treatment, the correct dosage of pesticide has to be applied for each kind of culture. In this context, this project aims to quantify the levels of the active ingredients Imidacloprid and Chlorpyrifos present in formulated technical products and compare with the reported in the ir commercial leaflets. The analyzes were performed by Ultra Performance Liquid Chromatography coupled to a photodiode array detector (CLUE-DAD). The identification of Imidacloprid and Chlorpyrifos in the samples was realized by comparison of the time of retention and UV spectre of those substances with the commercials patterns, resulting in a excellent method specificity of the method. In the scope of determination of active ingredients in formulated products, the method developed showed good sensitivity in the applied conditions, with suitables limits of detection (4,2.10-² mg L-¹ for Imidacloprid and 1,1.10-¹ mg L-¹ to Chlorpyrifos) and quantitation (1,4.10-¹ mg L-¹ and Imidacloprid 3,6.10-¹ mg L-¹ to Chlorpyrifos) for the concentrations found in matrices analyzed. Furthermore, good results were obtained to the method accuracy with coeficiente of variance values in the range of 0,6 to 0,7% for repeatability (intra-day) and 0,4 to 0,58% for intermediate precision (inter- day). The accuracy of the method was determined by recovery tests, the values were comprised in the range of 98 102%. According to the recommendations of the Associação Brasileira de Normas Técnicas, these values show good accuracy of the method. The concentrations obtained in the quantification of the active ingredients in formulated products showed values within permited by ABNT, 60.1% (w/v) ± 0.6%...
Resumo:
Introduction: Sedentary behavior is characterized by individuals who designed much of the day sitting or lying down activities, even if such conduct regular physical activity. Over the years people tend to be less active, worsening the quality of life. For healthy aging is necessary for the individual to be constantly active, and moving activities improve mood and quality of life, though little is known of the influence of sedentary behavior in these variables. Aim: To investigate the association between sedentary time, quality of life and mood states of elderly women engaged in physical activity. Methodology: The study included 68 elderly women who belong to the Physical Activity Program for the Elderly (PROFIT), for at least 6 months. These answered the Sedentary Behaviour Questionnaire, the Pentacle Welfare and IPAQ Short Version. The Pep States List Reduced and Illustrated (LEA-RI) was applied before and after a workout and before and after three times of sedentary behaviors. To evaluate the difference of sedentary behavior time average for each domain of quality of life was conducted the analysis of the 95% confidence interval for the STATA program version 12.0 and to the moods list data a non-parametric test - test binomial using SPSS version 17.0 program and has adopted a p≤0,05. Results: A moderate intensity physical activity was the most practiced (939.5 ± 650.2 min / week) and the activity most frequently performed in sedentary time was watching television (187.6 ± 96,4min / day). In general, the quality of life for the elderly is considered good (98.39%) and the disease is most prevalent hypertension (29.47%). After a physical activity older felt less useless, less shy and less fear and after a sedentary behavior, felt less agitated and less useless. In relation between the domains of QOL and sedentary behavior time, there were no statistical differences. Conclusion: Elderly active even after a sedentary behavior...
Resumo:
É comum nas áreas rurais a utilização de métodos de irrigação que consistem em bombear a água de açudes, lagoas e rios para irrigar a terra onde está sendo cultivada determinada cultura. Em geral esse bombeamento é feito por motores movidos á energia elétrica ou á óleo diesel. Este trabalho visa avaliar os motores elétricos de baixa potência que são usados para irrigar pequenas áreas plantadas através de bombeamento de água de açudes, lagoas etc. Os métodos a serem usados competem á aplicação da Física e do Calculo Diferencial e Integral, através do uso de conceitos,integrais definidas e do uso de sólidos de revolução para simulação. Poderão ser feitas associações entre vazão de água, potência necessária para o serviço, a quantidade de tempo que a reserva de água sustenta o bombeamento. Depois de feito os cálculos pode se concluir sobre o tipo de motor e potencia mais adequada para tal serviço. Este projeto visa avaliar o desempenho de motores elétrico de baixa potencia no bombeamento de água através de métodos pertinentes ao calculo diferencial e integral e ao mesmo tempo poder mostrar uma das várias aplicações desta disciplina. Após os cálculos realizados espera-se obter conclusões sobre os motores elétricos e fazer a associação do serviço que é recomendado para o seu uso. Serão utilizados métodos do cálculo diferencial e Integral para a avaliação do desempenho do motor e conceitos da Física para determinação e associação entre potência dissipada e vazão de água.