900 resultados para Fast neutrons.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The delayed Gadolinium Enhanced MRI of Cartilage (dGEMRIC) technique has shown promising results in pilot clinical studies of early osteoarthritis. Currently, its broader acceptance is limited by the long scan time and the need for postprocessing to calculate the T1 maps. A fast T1 mapping imaging technique based on two spoiled gradient echo images was implemented. In phantom studies, an appropriate flip angle combination optimized for center T1 of 756 to 955 ms yielded excellent agreement with T1 measured using the inversion recovery technique in the range of 200 to 900 ms, of interest in normal and diseased cartilage. In vivo validation was performed by serially imaging 26 hips using the inversion recovery and the Fast 2 angle T1 mapping techniques (center T1 756 ms). Excellent correlation with Pearson correlation coefficient R2 of 0.74 was seen and Bland-Altman plots demonstrated no systematic bias.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To determine the feasibility of using a high resolution isotropic three-dimensional (3D) fast T1 mapping sequence for delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) to assess osteoarthritis in the hip. MATERIALS AND METHODS: T1 maps of the hip were acquired using both low and high resolution techniques following the administration of 0.2 mmol/kg Gd-DTPA(2-) in 35 patients. Both T1 maps were generated from two separate spoiled GRE images. The high resolution T1 map was reconstructed in the anatomically equivalent plane as the low resolution map. T1 values from the equivalent anatomic regions containing femoral and acetabular cartilages were measured on the low and high resolution maps and compared using regression analysis. RESULTS: In vivo T1 measurements showed a statistically significant correlation between the low and high resolution acquisitions at 1.5 Tesla (R(2) = 0.958, P < 0.001). These results demonstrate the feasibility of using a fast two-angle T1 mapping (F2T1) sequence with isotropic spatial resolution (0.8 x 0.8 x 0.8 mm) for quantitative assessment of biochemical status in articular cartilage of the hip. CONCLUSION: The high resolution 3D F2T1 sequence provides accurate T1 measurements in femoral and acetabular cartilages of the hip, which enables the biochemical assessment of articular cartilage in any plane through the joint. It is a powerful tool for researchers and clinicians to acquire high resolution data in a reasonable scan time (< 30 min).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Cartilage defects are common pathologies and surgical cartilage repair shows promising results. In its postoperative evaluation, the magnetic resonance observation of cartilage repair tissue (MOCART) score, using different variables to describe the constitution of the cartilage repair tissue and the surrounding structures, is widely used. High-field magnetic resonance imaging (MRI) and 3-dimensional (3D) isotropic sequences may combine ideal preconditions to enhance the diagnostic performance of cartilage imaging.Aim of this study was to introduce an improved 3D MOCART score using the possibilities of an isotropic 3D true fast imaging with steady-state precession (True-FISP) sequence in the postoperative evaluation of patients after matrix-associated autologous chondrocyte transplantation (MACT) as well as to compare the results to the conventional 2D MOCART score using standard MR sequences. MATERIAL AND METHODS: The study had approval by the local ethics commission. One hundred consecutive MR scans in 60 patients at standard follow-up intervals of 1, 3, 6, 12, 24, and 60 months after MACT of the knee joint were prospectively included. The mean follow-up interval of this cross-sectional evaluation was 21.4 +/- 20.6 months; the mean age of the patients was 35.8 +/- 9.4 years. MRI was performed at a 3.0 Tesla unit. All variables of the standard 2D MOCART score where part of the new 3D MOCART score. Furthermore, additional variables and options were included with the aims to use the capabilities of isotropic MRI, to include the results of recent studies, and to adapt to the needs of patients and physician in a clinical routine examination. A proton-density turbo spin-echo sequence, a T2-weighted dual fast spin-echo (dual-FSE) sequence, and a T1-weighted turbo inversion recovery magnitude (TIRM) sequence were used to assess the standard 2D MOCART score; an isotropic 3D-TrueFISP sequence was prepared to evaluate the new 3D MOCART score. All 9 variables of the 2D MOCART score were compared with the corresponding variables obtained by the 3D MOCART score using the Pearson correlation coefficient; additionally the subjective quality and possible artifacts of the MR sequences were analyzed. RESULTS: The correlation between the standard 2D MOCART score and the new 3D MOCART showed for the 8 variables "defect fill," "cartilage interface," "surface," "adhesions," "structure," "signal intensity," "subchondral lamina," and "effusion"-a highly significant (P < 0.001) correlation with a Pearson coefficient between 0.566 and 0.932. The variable "bone marrow edema" correlated significantly (P < 0.05; Pearson coefficient: 0.257). The subjective quality of the 3 standard MR sequences was comparable to the isotropic 3D-TrueFISP sequence. Artifacts were more frequently visible within the 3D-TrueFISP sequence. CONCLUSION: In the clinical routine follow-up after cartilage repair, the 3D MOCART score, assessed by only 1 high-resolution isotropic MR sequence, provides comparable information than the standard 2D MOCART score. Hence, the new 3D MOCART score has the potential to combine the information of the standard 2D MOCART score with the possible advantages of isotropic 3D MRI at high-field. A clear limitation of the 3D-TrueFISP sequence was the high number of artifacts. Future studies have to prove the clinical benefits of a 3D MOCART score.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Modern e-learning systems represent a special type of web information systems. By definition, information systems are special computerized systems used to perform data operations by multiple users simultaneously. Each active user consumes an amount of hardware resources. A shortage of hardware resources can be caused by growing number of simultaneous users. Such situation can result in overall malfunctioning or slowed-down system. In order to avoid this problem, the underlying hardware system gets usually continuously upgraded. These upgrades, typically accompanied with various software updates, usually result in a temporarily increased amount of available resources. This work deals with the problem in a different way by proposing an implementation of a web e-learning system with a modified software architecture reducing resource usage of the server part to the bare minimum. In order to implement a full-scale e-learning system that could be used as a substitute to a conventional web e-learning system, a Rich Internet Application framework was used as basis. The technology allowed implementation of advanced interactivity features and provided an easy transfer of a substantial part of the application logic from server to clients. In combination with a special server application, the server part of the new system is able to run with a reasonable performance on a hardware with very limited computing resources.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A basic prerequisite for in vivo X-ray imaging of the lung is the exact determination of radiation dose. Achieving resolutions of the order of micrometres may become particularly challenging owing to increased dose, which in the worst case can be lethal for the imaged animal model. A framework for linking image quality to radiation dose in order to optimize experimental parameters with respect to dose reduction is presented. The approach may find application for current and future in vivo studies to facilitate proper experiment planning and radiation risk assessment on the one hand and exploit imaging capabilities on the other.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In more than 95% of patients with atrioventricular nodal reentrant tachycardia (AVNRT), curative treatment can be achieved with selective ablation of the slow pathway in the right-sided septum. We report a patient with typical AVNRT who had failed attempts to perform conventional right septal ablation of the slow as well as of the fast pathway and finally underwent successful ablation of the fast pathway on the left side of the interatrial septum using a transseptal approach.