990 resultados para ENDOSCOPIC TRACHEAL OCCLUSION
Resumo:
Background: Levels of endoscopic demand and capacity in West Africa are unclear. Objectives: This paper aims to: 1. describe the current labor and endoscopic capacity, 2. quantify the impact of a mixed-methods endoscopy course on healthcare professionals in West Africa, and 3. quantify the types of diagnoses encountered. Methods: In a three-day course, healthcare professionals were surveyed on endoscopic resources and capacity and were taught through active observation of live cases, case discussion, simulator experience and didactics. Before and after didactics, multiplechoice exams as well as questionnaires were administered to assess for course efficacy. Also, a case series of 23 patients needing upper GI endoscopy was done. Results: In surveying physicians, less than half had resources to perform an EGD and none could perform an ERCP, while waiting time for emergency endoscopy in urban populations was at least one day. In assessing improvement in medical knowledge among participants after didactics, objective data paired with subjective responses was more useful than either alone. Of 23 patients who received endoscopy, 7 required endoscopic intervention with 6 having gastric or esophageal varices. Currently the endoscopic capacity in West Africa is not sufficient. A formal GI course with simulation and didactics improves gastrointestinal knowledge amongst participants.
Resumo:
Hydrocephalus has been known to affect humans since the birth of human medicine as it is described by Hippocrates. The management of this condition is however still dodged by challenges due to a poor understanding of its pathophysiology. The ventriculoperitoneal shunt presents considerable problems especially with respect to infection and shunt malfunction. Low income countries, that currently face the greater burden of paediatric hydrocephalus. experience an increased challenge with ventriculoperitoneal shunts due to a shortage of qualified personnel to handle shunt complications. Recent advances in neuro-endoscopic surgery have presented opportunities for alternative treatment options for hydrocephalus such as endoscopic third ventriculostomy (ETV). This paper explores the alternative views in the pathophysiology of hydrocephalus and how they explain the effectiveness of ETV in treating hydrocephalus arising from a variety of causes.
Resumo:
Background and aim: The aim of this study was to evaluate the efficacy of endoscopic band ligation (EBL) in carefully selected patients who would benefit from this method of resection. Methods: Patients with early upper gastrointestinal and small (< 15 mm) lesions treated with EBL (Duette® Multi-Band Mucosectomy) were prospectively recruited and retrospectively analyzed between 2010 and 2015. All cases were discussed in a multidisciplinary cancer committee and it was concluded that, owing to patient conditions, surgery was not possible and that not conducting histology would not change the clinical management. A first endoscopic control with biopsies was planned at 4-8 weeks. If there was no persistence of the lesion, new controls were programmed at 6 and 12 months. Results: The group (n = 12) included 5 esophagus lesions (adenosquamous carcinoma, n = 1; carcinoma squamous, n = 2; adenocarcinoma, n = 2); 4 gastric lesions (high grade dysplasia, n = 1; adenocarcinoma, n = 2; neuroendocrine tumor [NET], n = 1), and 3 duodenal lesions (NETs) (n = 3). The mean tumor diameter was 9.6 ± 2.8 mm (range 4-15). Only one minor adverse event was described. At first follow-up (4-8 weeks), there was 91.6% and 75% of endoscopic and histological remission, respectively. At 6-month follow-up there was 70% of both endoscopic remission and negative biopsies. And at 12 months, there was 100% and 75% of endoscopic and histological remission, respectively. Persisting lesions were T1 cancers. The median follow-up was 30.6 months. Conclusion: EBL without resection is an easy and safe technique that should be considered in patients with multiple morbidities and small superficial UGI lesions.
Resumo:
Background and aim: This article provides a practical review to undertaking safe endoscopic ampullectomy and highlights some of the common difficulties with this technique as well as offering strategies to deal with these challenges. Methods: We conducted a review of studies regarding endoscopic ampullectomy for ampullary neoplasms with special focus on techniques. Results: Accurate preoperative diagnosis and staging of ampullary tumors is imperative for predicting prognosis and determining the most appropriate therapeutic approach. The optimal technique for endoscopic ampullectomy is dependent on the lesions size. En bloc resection is recommended for lesions confined to the papilla. There is no significant evidence to support the submucosal injection before ampullectomy. There is no consensus regarding the optimal current and power output for endoscopic ampulectomy. The benefits of a thermal adjunctive therapy remain controversial. A prophylactic pancreatic stent reduces the incidence and severity of pancreatitis post-ampullectomy. Conclusions: Endoscopic ampullectomy is a safe and efficacious therapeutic procedure for papillary adenomas in experienced endoscopist and it can avoid the need for surgical intervention.
Resumo:
This thesis presents an investigation on endoscopic optical coherence tomography (OCT). As a noninvasive imaging modality, OCT emerges as an increasingly important diagnostic tool for many clinical applications. Despite of many of its merits, such as high resolution and depth resolvability, a major limitation is the relatively shallow penetration depth in tissue (about 2∼3 mm). This is mainly due to tissue scattering and absorption. To overcome this limitation, people have been developing many different endoscopic OCT systems. By utilizing a minimally invasive endoscope, the OCT probing beam can be brought to the close vicinity of the tissue of interest and bypass the scattering of intervening tissues so that it can collect the reflected light signal from desired depth and provide a clear image representing the physiological structure of the region, which can not be disclosed by traditional OCT. In this thesis, three endoscope designs have been studied. While they rely on vastly different principles, they all converge to solve this long-standing problem.
A hand-held endoscope with manual scanning is first explored. When a user is holding a hand- held endoscope to examine samples, the movement of the device provides a natural scanning. We proposed and implemented an optical tracking system to estimate and record the trajectory of the device. By registering the OCT axial scan with the spatial information obtained from the tracking system, one can use this system to simply ‘paint’ a desired volume and get any arbitrary scanning pattern by manually waving the endoscope over the region of interest. The accuracy of the tracking system was measured to be about 10 microns, which is comparable to the lateral resolution of most OCT system. Targeted phantom sample and biological samples were manually scanned and the reconstructed images verified the method.
Next, we investigated a mechanical way to steer the beam in an OCT endoscope, which is termed as Paired-angle-rotation scanning (PARS). This concept was proposed by my colleague and we further developed this technology by enhancing the longevity of the device, reducing the diameter of the probe, and shrinking down the form factor of the hand-piece. Several families of probes have been designed and fabricated with various optical performances. They have been applied to different applications, including the collector channel examination for glaucoma stent implantation, and vitreous remnant detection during live animal vitrectomy.
Lastly a novel non-moving scanning method has been devised. This approach is based on the EO effect of a KTN crystal. With Ohmic contact of the electrodes, the KTN crystal can exhibit a special mode of EO effect, termed as space-charge-controlled electro-optic effect, where the carrier electron will be injected into the material via the Ohmic contact. By applying a high voltage across the material, a linear phase profile can be built under this mode, which in turn deflects the light beam passing through. We constructed a relay telescope to adapt the KTN deflector into a bench top OCT scanning system. One of major technical challenges for this system is the strong chromatic dispersion of KTN crystal within the wavelength band of OCT system. We investigated its impact on the acquired OCT images and proposed a new approach to estimate and compensate the actual dispersion. Comparing with traditional methods, the new method is more computational efficient and accurate. Some biological samples were scanned by this KTN based system. The acquired images justified the feasibility of the usage of this system into a endoscopy setting. My research above all aims to provide solutions to implement an OCT endoscope. As technology evolves from manual, to mechanical, and to electrical approaches, different solutions are presented. Since all have their own advantages and disadvantages, one has to determine the actual requirements and select the best fit for a specific application.
Resumo:
Whipple's disease is a chronic systemic infection produced by the actinomycete Tropheryma whipplei. Endoscopic tests are key in the diagnosis as they allow biopsy and histopathological examination for definitive diagnosis of this entity. We present a case of Whipple's disease where capsule endoscopy, uncommon for the diagnosis of this condition, was essential for it and its performance before and after antibiotic treatment allows to describe the macroscopic evolution of the findings in the small bowel. This case illustrates the usefulness of capsule endoscopy to allow complete examination of the small bowel disease in which up to 30% of patients may present with normal endoscopy.
Resumo:
Introduction: Flexible endoscopic treatment is one of the alternative approaches for the management of Zenker's diverticum. The present paper shows our short-term and long-term results with flexible endoscopic cricopharyngeal myotomy/septotomy. Patients and methods: A retrospective analysis of our experience in patients with Zenker's diverticulum treated using a flexible endoscope, assisted by a flexible diverticuloscope, between 2002 and 2015. Myotomy/septotomy was performed with a needle-knife papillotome under deep sedation or general anesthesia. Results: Among the 64 patients treated, two died within 10 days of surgery from causes not directly related to the procedure, and one presented with pharyngo-esophageal perforation, which recovered with conservative management at 47 days after admission. Four additional patients were lost to short-term follow-up. Among the 57 remaining patients, 52 had complete relief of dysphagia after 6 weeks. Eleven of these had recurrent symptoms on the mid and the long term. Eight were retreated with the same flexible endoscopic technique, one with a hybrid endoscopic approach, one with classical open surgery and one refused retreatment. After a mean follow-up of 2 years and a half, 33 of 37 patients reported absent or minimal dysphagia, controllable with punctual dietary restrictions. Conclusions: Flexible endoscopic treatment for Zenker's diverticulum is effective and safe. It represents an option on an equal footing to rigid endoscopy and classical open surgery and may also be used when the latter two are technically impracticable or contraindicated.
Resumo:
Background: Tracheal intubation is extremely distressing, painful, and may influence heart rate and blood pressure. Sedatives, analgesics, and muscle relaxants are not commonly used for intubation in neonates. Objectives: This study aimed to evaluate the effects of lidocaine spray as a non-intravenous drug before neonatal intubation on blood pressure, heart rate, oxygen saturation and time of intubation. Patients and Methods: In a randomized, controlled study each neonate was randomly assigned to one of the two study groups by staffs who were not involved in the infant's care. The allocation concealment was kept in an opaque sealed envelope, and the investigators, the patient care team, and the assessors were blinded to the treatment allocation. The selected setting was NICU unit of a teaching hospital in Ilam city, Iran and participants were 60 neonates with indication of tracheal intubation with gestational age >30 weeks. Patients in the treatment group received lidocaine spray and the placebo group received spray of normal saline prior to intubation. Main outcome measurements were the mean rates of blood pressure, heart rate, oxygen saturation, intubation time and lidocaine side effects were measured before and after intubation. Results: Totally 60 newborns including 31 boys and 29 girls were entered into the study (drug group n = 30; placebo group n = 30). Boy/girl ratio in treatment and placebo groups were 1.3 and 0.88, respectively. Mean age ± SD of participants was 34.1 ± 24.8 hours (treatment: 35.3 ± 25.7; placebo: 32.9 ± 24.3; P < 0.0001). Mean weight ± SD of neonates was 2012.5 ± 969 g. Application of lidocaine spray caused a significant reduction of mean intubation time among treatment group compared with placebo group (treatment: 15.03 ± 2.2 seconds; placebo: 18.3 ± 2.3 seconds; P < 0.0001). Mean blood pressure, heart rate and oxygen saturation rate, among neonates in treatment group was reduced after intubation compared with their relevant figures before intubation; however, their differences were not statistically significant except for mean oxygen saturation rate that was reduced significantly in placebo group. No side effects were observed during study. Conclusions: Though the current study revealed some promising results in the application of lidocaine spray during neonatal intubation without any considerable side effects; however, the current investigation could only be considered as a pilot study for further attempts in different locations with higher sample sizes and in different situations.
Resumo:
Percutaneous left atrial appendage (LAA) closure represents a complementary option and effective treatment for patients at risk of thromboembolism, especially in patients for whom it may be difficult to achieve satisfactory anticoagulation control or where anticoagulation treatment is not possible or desirable. Effective and safe transcatheter LAA occlusion requires a detailed knowledge of crucial anatomic landmarks and endocardial morphologic variants of the LAA and its neighbouring structures.1 ,2 w1–w3 Our aim in this article is to provide the basic anatomic information that is important for the interventional cardiologist to know when planning an LAA occlusion procedure.
Resumo:
The aim was to evaluate the relationship between orofacial function, dentofacial morphology, and bite force in young subjects. Three hundred and sixteen subjects were divided according to dentition stage (early, intermediate, and late mixed and permanent dentition). Orofacial function was screened using the Nordic Orofacial Test-Screening (NOT-S). Orthodontic treatment need, bite force, lateral and frontal craniofacial dimensions and presence of sleep bruxism were also assessed. The results were submitted to descriptive statistics, normality and correlation tests, analysis of variance, and multiple linear regression to test the relationship between NOT-S scores and the studied independent variables. The variance of NOT-S scores between groups was not significant. The evaluation of the variables that significantly contributed to NOT-S scores variation showed that age and presence of bruxism related to higher NOT-S total scores, while the increase in overbite measurement and presence of closed lip posture related to lower scores. Bite force did not show a significant relationship with scores of orofacial dysfunction. No significant correlations between craniofacial dimensions and NOT-S scores were observed. Age and sleep bruxism were related to higher NOT-S scores, while the increase in overbite measurement and closed lip posture contributed to lower scores of orofacial dysfunction.