981 resultados para EMISSION COMPUTED-TOMOGRAPHY
Resumo:
Lung cancer remains the most common cause of cancer-related mortality in Scotland, accounting for 28.9% of all cancer deaths in 2007. Current guidelines recommend assessment of patient fitness and operability by a multidisciplinary team when selecting management options. Two of the most important prognostic markers are the stage of disease and ECOG performance status. In 1996, the International Association for the Study of Lung Cancer (IASLC) launched a worldwide TNM staging project to create international databases that would be used to continue the excellent efforts of Dr. Cliff Mountain, who pioneered this approach to lung cancer staging in 1973. Successive iterations of tumor, nodule, metastasis (TNM) staging for lung cancer have addressed shortcomings identified by the oncology community. Similarly, the IASLC recognized that it is important that further revisions continue to be made to ensure that the international staging system for lung cancer remains fit for its purpose. The last work of the International Staging Committee (ISC) was the conduct of the study that informed the seventh edition of the international staging system for lung cancer, in 2010. This review of image and staging in non small cell lung cancer (NSCLC), includes a summary of the different noninvasive tests currently available for staging non small cell lung cancer.
Resumo:
Introduction: Quantitative computed tomography (qCT)-based assessment of total lung weight (M(lung)) has the potential to differentiate atelectasis from consolidation and could thus provide valuable information for managing trauma patients fulfilling commonly used criteria for acute lung injury (ALI). We hypothesized that qCT would identify atelectasis as a frequent mimic of early posttraumatic ALI. Methods: In this prospective observational study, M(lung) was calculated by qCT in 78 mechanically ventilated trauma patients fulfilling the ALI criteria at admission. A reference interval for M(lung) was derived from 74 trauma patients with morphologically and functionally normal lungs (reference). Results are given as medians with interquartile ranges. Results: The ratio of arterial partial pressure of oxygen to the fraction of inspired oxygen was 560 (506 to 616) mmHg in reference patients and 169 (95 to 240) mmHg in ALI patients. The median reference M(lung) value was 885 (771 to 973) g, and the reference interval for M(lung) was 584 to 1164 g, which matched that of previous reports. Despite the significantly greater median M(lung) value (1088 (862 to 1,342) g) in the ALI group, 46 (59%) ALI patients had M(lung) values within the reference interval and thus most likely had atelectasis. In only 17 patients (22%), Mlung was increased to the range previously reported for ALI patients and compatible with lung consolidation. Statistically significant differences between atelectasis and consolidation patients were found for age, Lung Injury Score, Glasgow Coma Scale score, total lung volume, mass of the nonaerated lung compartment, ventilator-free days and intensive care unit-free days. Conclusions: Atelectasis is a frequent cause of early posttraumatic lung dysfunction. Differentiation between atelectasis and consolidation from other causes of lung damage by using qCT may help to identify patients who could benefit from management strategies such as damage control surgery and lung-protective mechanical ventilation that focus on the prevention of pulmonary complications.
Resumo:
Studies evaluating radiologic aspects, local complications, and structural alterations of the paranasal sinus in patients with mucosal leishmaniasis (ML) are lacking The aim of this study was to analyze alterations of the paranasal sinuses in patients with ML by using computed tomography (CT) scans This prospective study evaluated 26 patients in Brazil with ML Nom December 2008 through June 2009 All patients underwent CT scans of the paranasal sinuses Paranasal thickening was observed in 25 patients (96%) Nasal perforation was observed in 17 patients (65%) Those patients who received re-treatment showed more abnormalities on CT scan than cured patients (P < 0 05) Complications of ML are not limited to the nasal mucosa but extend to the paranasal sinuses. Mucosa! thickening. pacified air cells. bony remodeling, and bony thickening caused by inflammatory steals of the sinus cavity walls are CT findings suggestive of chronic sinusitis
Resumo:
Introduction: This study evaluated the interobserver reliability of plain radiograpy versus computed tomography (CT) for the Universal and AO classification systems for distal radius fractures. Patients and methods: Five observers classified 21 sets of distal radius fractures using plain radiographs and CT independently. Kappa statistics were used to establish a relative level of agreement between observers for both readings. Results: Interobserver agreement was rated as moderate for the Universal classification and poor for the AO classification. Reducing the AO system to 9 categories and to its three main types reliability was raised to a ""moderate"" level. No difference was found for interobserver reliability between the Universal classification using plain radiographs and the Universal classification using computed tomography. Interobserver reliability of the AO classification system using plain radiographs was significantly higher than the interobserver reliability of the AO classification system using only computed tomography. Conclusion: From these data, we conclude that classification of distal radius fractures using CT scanning without plain radiographs is not beneficial.
Resumo:
Introduction: Two hundred ten patients with newly diagnosed Hodgkin`s lymphoma (HL) were consecutively enrolled in this prospective trial to evaluate the cost-effectiveness of fluorine-18 ((18)F)-fluoro-2-deoxy-D-glucose-positron emission tomography (FDG-PET) scan in initial staging of patients with HL. Methods: All 210 patients were staged with conventional clinical staging (CCS) methods, including computed tomography (CT), bone marrow biopsy (BMB), and laboratory tests. Patients were also submitted to metabolic staging (MS) with whole-body FDG-PET scan before the beginning of treatment. A standard of reference for staging was determined with all staging procedures, histologic examination, and follow-up examinations. The accuracy of the CCS was compared with the MS. Local unit costs of procedures and tests were evaluated. Incremental cost-effectiveness ratio (ICER) was calculated for both strategies. Results: In the 210 patients with HL, the sensitivity for initial staging of FDG-PET was higher than that of CT and BMB in initial staging (97.9% vs. 87.3%; P < .001 and 94.2% vs. 71.4%, P < 0.003, respectively). The incorporation of FDG-PET in the staging procedure upstaged disease in 50 (24%) patients and downstaged disease in 17 (8%) patients. Changes in treatment would be seen in 32 (15%) patients. Cumulative cost for staging procedures was $3751/patient for CCS compared to $5081 for CCS + PET and $4588 for PET/CT. The ICER of PET/CT strategy was $16,215 per patient with modified treatment. PET/CT costs at the beginning and end of treatment would increase total costs of HL staging and first-line treatment by only 2%. Conclusion: FDG-PET is more accurate than CT and BMB in HL staging. Given observed probabilities, FDG-PET is highly cost-effective in the public health care program in Brazil.
Resumo:
Atelectasis after either vaginal or Caesarean delivery has not been adequately quantified. This study addresses the hypothesis that atelectasis may be worse in women who undergo Caesarean section when compared with vaginal delivery under regional anaesthesia. Twenty healthy non-smoking women submitted to a chest computed tomography (CT) 2 h after delivery in a University Hospital, who had experienced vaginal delivery (n=10) under combined spinal-epidural analgesia or a Caesarean section (n=10) under spinal anaesthesia, were evaluated. The percentage cross-sectional area of atelectasis in dependent lung regions were measured from the CT images obtained at cross-section of the xiphoid process and the top of the diaphragm. The percentage cross-sectional area of atelectasis was 3.95% in the vaginal delivery group and 14.1% in the Caesarean group (P < 0.001, Mann-Whitney rank sum test). These results suggested that pulmonary atelectasis is greater after Caesarean section delivery under spinal anaesthesia than after vaginal delivery with combined spinal-epidural analgesia.
Resumo:
Lymphangiomas are benign nonencapsulated lesions composed of sequestered noncommunicating lymphoid tissue lined by lymphatic endothelium and are thought to be caused by congenital obstruction of lymphatic drainage. They are subclassified by vessel size, such as the capillary, which is rare and located in subcutaneous tissue, cavernous (located about the mouth and tongue), and cystic (cystic hygromas). The cystic hygromas show a predilection for the neck (75%) and maxilla (20%), and the remaining 5% arise in rare locations such as the mediastinum, retroperitoneum, bone, kidney, colon, liver, spleen and scrotum. Only 3%-10% of neck lesions extend into the mediastinum. In this paper, we report a rare case of cystic hygroma with a huge dimension discussing the use of computed tomography scanning for diagnosis.
Resumo:
Objective. The purpose of this research was to provide further evidence to demonstrate the precision and accuracy of maxillofacial linear and angular measurements obtained by cone-beam computed tomography (CBCT) images. Study design. The study population consisted of 15 dry human skulls that were submitted to CBCT, and 3-dimensional (3D) images were generated. Linear and angular measurements based on conventional craniometric anatomical landmarks, and were identified in 3D-CBCT images by 2 radiologists twice each independently. Subsequently, physical measurements were made by a third examiner using a digital caliper and a digital goniometer. Results. The results demonstrated no statistically significant difference between inter-and intra-examiner analysis. Regarding accuracy test, no statistically significant differences were found of the comparison between the physical and CBCT-based linear and angular measurements for both examiners (P = .968 and .915, P = .844 and .700, respectively). Conclusions. 3D-CBCT images can be used to obtain dimensionally accurate linear and angular measurements from bony maxillofacial structures and landmarks. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 108: 430-436)
Resumo:
Objectives. The diagnosis of root fractures by conventional radiographs is still difficult because of limitations of 2D images. Cone-beam volumetric tomography improves the diagnosis capacity in dentistry, such as increased radiation dose to the patient and presence of artifacts on the image. Study design. This study compared the images obtained on conventional periapical radiographs and 3D scans (Accuitomo 3DX) for the diagnosis of root fractures. Twenty patients with suspected root fractures were submitted to examination by periapical radiography and CBCT. Two professionals, unaware of the symptomatology, examined these radiographs and CBCT images according to pre-established scores, which were later checked against the signs and symptoms. Results. The results revealed statistical difference for cone-beam volumetric tomography compared with conventional radiographs in the diagnosis of root fractures. Conclusion. It could be concluded that cone-beam volumetric tomography was better than conventional radiography in the diagnosis of root fractures, thereby constituting an excellent alternative for diagnosis in general practice. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 108: 270-277)
Resumo:
Os linfomas são tumores estabelecidos a nível do sistema linfático. Devido à sua heterogeneidade classificam-se como Linfoma Hodgkin (LH) e Linfoma não Hodgkin (LNH), apresentando diferente prognóstico e seguimento quimioterapêutico. Actualmente, a Photon Emission Tomography/Computed Tomography (PET/CT, do acrónimo inglês) é considerada “imagem” de excelência no estudo desta patologia. Neste contexto, é objectivo deste artigo verificar a utilidade da técnica PET/CT e correlacionar o valor de Standard Uptake Value (SUV), obtido pela PET, com o estadio histológico do linfoma e com a resposta ao tratamento quimioterapêutico. Metodologia - Analisaram-se retrospectivamente 356 estudos respeitantes a 231 pacientes, aos quais se realizou uma PET/CT para estadiamento, estudo de massa ou avaliação da resposta ao tratamento. Após a administração de uma actividade média de 18F-FDG de 288,6 MBq, foram adquiridas imagens numa PET/CT GE Discovery ST. Os resultados obtidos foram comparados com os dados clínicos dos pacientes. Resultados - Foram encontradas diferenças significativas entre a idade Vs tipo de linfoma. Não foram encontradas diferenças significativas entre: valor de SUVmáx ganglionar, lesões extra-ganglionares e seu valor de SUV relativamente ao tipo de linfoma. Comprovou-se a influência da PET/CT na alteração do estadio do linfoma e atitude terapêutica. Em última análise, obtiveram-se respectivamente os seguintes valores de sensibilidade, especificidade e exactidão: 98%, 79% e 88%. Conclusões - Os resultados obtidos permitem verificar a importância da imagem PET/CT no estadiamento, monitorização e alteração da atitude terapêutica dos LH e LNH.
Resumo:
Introdução – O cancro de pulmão/traqueia e brônquios é a principal causa de morte por neoplasia na União Europeia. A técnica de duas aquisições de imagem em tempos diferentes no Positron Emission Tomography/Computed Tomography (PET/CT) tem sido referenciada em alguns artigos como uma mais-valia no diagnóstico do cancro do pulmão. O objectivo deste estudo consiste em avaliar a eficiência diagnóstica do PET/CT com a aquisição das duas imagens em tempos diferentes na caracterização do nódulo solitário pulmonar (NSP), tendo em conta a histologia e o tamanho do nódulo. Metodologia – Foram analisados 115 NSP, num total de 110 pacientes, dos quais 65 nódulos eram malignos. Adquiriram-se duas imagens, a primeira a um tempo médio de 52 minutos e a segunda a um tempo médio de 125 minutos após administração do 18F-2-fluoro-2-deoxi-D-glucose (18F-FDG). Para a análise das imagens obteve-se o standard uptake value máximo (SUVmax) e a percentagem de variação dos SUVmax (%variação). Resultados – A %variação apresenta valores de eficiência diagnóstica superiores à análise dos SUVmax em separado. Existem também diferenças significativas na histologia e no SUVmax, registando-se um aumento do SUVmax2 comparativamente ao SUVmax1 nas patologias malignas. Conclusão – A técnica da aquisição de duas imagens em tempos diferentes mostrou ser mais eficaz na caracterização do NSP do que a análise de apenas uma imagem.
Resumo:
Mestrado em Medicina Nuclear.
Resumo:
Introdução – O melanoma maligno cutâneo (MMC) é considerado uma das mais letais neoplasias e no seu seguimento recorre-se, para além dos exames clínicos e da análise de marcadores tumorais, a diversos métodos imagiológicos, como é o exame Tomografia por Emissão de Positrões/Tomografia Computorizada (PET/CT, do acrónimo inglês Positron Emission Tomography/Computed Tomography) com 18fluor-fluorodeoxiglucose (18F-FDG). O presente estudo tem como objetivo avaliar a utilidade da PET/CT relativamente à análise da extensão e à suspeita de recidiva do MMC, comparando os achados imagiológicos com os descritos em estudos CT. Metodologia – Estudo retrospetivo de 62 estudos PET/CT realizados em 50 pacientes diagnosticados com MMC. Excluiu-se um estudo cujo resultado era duvidoso (nódulo pulmonar). As informações relativas aos resultados dos estudos anatomopatológicos e dos exames imagiológicos foram obtidas através da história clínica e dos relatórios médicos dos estudos CT e PET/CT. Foi criada uma base de dados com os dados recolhidos através do software Excel e foi efetuada uma análise estatística descritiva. Resultados – Dos estudos PET/CT analisados, 31 foram considerados verdadeiros positivos (VP), 28 verdadeiros negativos (VN), um falso positivo (FP) e um falso negativo (FN). A sensibilidade, especificidade, o valor preditivo positivo (VPP), o valor preditivo negativo (VPN) e a exatidão da PET/CT para o estadiamento e avaliação de suspeita de recidiva no MMC são, respetivamente, 96,9%, 96,6%, 96,9%, 96,6% e 96,7%. Dos resultados da CT considerados na análise estatística, 14 corresponderam a VP, 12 a VN, três a FP e cinco a FN. A sensibilidade, especificidade, o VPP e o VPN e a exatidão da CT para o estadiamento e avaliação de suspeita de recidiva no MMC são, respetivamente, 73,7%, 80,0%, 82,4%, 70,6% e 76,5%. Comparativamente aos resultados CT, a PET/CT permitiu uma mudança na atitude terapêutica em 23% dos estudos. Conclusão – A PET/CT é um exame útil na avaliação do MMC, caracterizando-se por uma maior acuidade diagnóstica no estadiamento e na avaliação de suspeita de recidiva do MMC comparativamente à CT isoladamente.
Resumo:
Aim: Optimise a set of exposure factors, with the lowest effective dose, to delineate spinal curvature with the modified Cobb method in a full spine using computed radiography (CR) for a 5-year-old paediatric anthropomorphic phantom. Methods: Images were acquired by varying a set of parameters: positions (antero-posterior (AP), posteroanterior (PA) and lateral), kilo-voltage peak (kVp) (66-90), source-to-image distance (SID) (150 to 200cm), broad focus and the use of a grid (grid in/out) to analyse the impact on E and image quality (IQ). IQ was analysed applying two approaches: objective [contrast-to-noise-ratio/(CNR] and perceptual, using 5 observers. Monte-Carlo modelling was used for dose estimation. Cohen’s Kappa coefficient was used to calculate inter-observer-variability. The angle was measured using Cobb’s method on lateral projections under different imaging conditions. Results: PA promoted the lowest effective dose (0.013 mSv) compared to AP (0.048 mSv) and lateral (0.025 mSv). The exposure parameters that allowed lower dose were 200cm SID, 90 kVp, broad focus and grid out for paediatrics using an Agfa CR system. Thirty-seven images were assessed for IQ and thirty-two were classified adequate. Cobb angle measurements varied between 16°±2.9 and 19.9°±0.9. Conclusion: Cobb angle measurements can be performed using the lowest dose with a low contrast-tonoise ratio. The variation on measurements for this was ±2.9° and this is within the range of acceptable clinical error without impact on clinical diagnosis. Further work is recommended on improvement to the sample size and a more robust perceptual IQ assessment protocol for observers.
Resumo:
Mestrado em Medicina Nuclear - Área de especialização: Tomografia por emissão de positrões