850 resultados para EMG,Sport,Cycling,Muscle Synergy,Coactivation,Co-contraction,running
Resumo:
Purpose: To identify the electromyographic fatigue threshold in the erector spinae muscle. Methods: Eight 19 to 24-year-old male volunteers participated in this study, in which surface electrodes were used, as well as a biological signals acquisition module (Lynx) with a sampling frequency of 1000Hz, a 1000 times gain, a 20Hz high pass filter and a 500Hz low pass filter. The test consisted of repeated isometric contractions of the erector spinae muscle in a 45° hip flexion posture, with 30%, 40%, 50% and 60% of the maximum voluntary isometric contraction. Results: A positive correlation of the RMS (root mean square) value as a function of time was found for most of the subjects with 40% (N = 6), 50% (N = 7) and 60% (N = 8) loads of the maximum voluntary isometric contraction. Conclusions: It was concluded, from this study, that the proposed protocol provides evidence, through the electromyographic signal, of the development of fatigue in the erector spinae muscle with loads of 40%, 50% and 60% of the maximum voluntary isometric contraction. The protocol also allows the electromyographic fatigue threshold and its probable applicability in the diagnosis of this phenomenon during repetitive activities to be determined.
Resumo:
It is usual to find athletes that can perform de curl up test easily, but are unable to maintain the stabilization of the low back during the double straight leg lowering (DSLL). In spite of having strong abdominal muscles, its stabilization role seems not to be effective. Thus, the purpose of this study was to verify the relation among individuals with strong abdominal muscles and the ability in perform posterior pelvic tilt (PPT); the ability to stabilize the low back during the DSLL and the eletromyographic activity of the abdominal muscles. Eighteen male subjects (aged 19.27 ± 3.5), without history of muscle skeletal dysfunction, performed both the PPT and DSLL tests. During these tests electromyographic signals of the rectus abdominis (RA), obliquus internus abdominis (01) and obliquus externus abdominis (OE) were recorded, the angle of the hip and the pressure under the low back were measured The results of analyses of variance (ANOVA) show that most volunteers accomplished the PPT test, actively flattening the low back with regular or good quality. However, none of them was able to stabilize the low back during the DSLL test. During the PPT test all abdominal muscle portions analysed were activated without significant differences. In an attempt of maintaining the lumbo-pelvic region stabilized during the DSLL, it was observed a tendency of higher bilateral activation of OE when compared to RA and 01 muscle portions between 70 and 20 degrees of hip flexion.
Resumo:
Three pig genetics lineages A, B and C marketed in Brazil, were stunning with the manual electric stunning (Karl Schermer 220-230/250 volts, 45-60 Hz and 1.4 - 1.5 A) and the collective gaseous system (COMBI-BUTINA 90% CO 2). The electric stunning provided higher blood splashed levels in the areas of the inside round (0.477 and 0.26, p ≤ 0.01), shoulder/cranial (0.154 and 0.039, p ≤ 0.005), shoulder/central (0.261 e 0.052, p ≤ 0.001), shoulder/caudal (0.180 and 0.030, p ≤ 0.01), loin/central (0.185 and 0.065, p ≤ 0.01), loin/caudal (0.06 and 0.207, p ≤ 0.01) and loin/lateral external (0.061 and 0.013, p ≤ 0.05), as well as more diffuse blood splashed in the areas of the inside round (0.461 and 0.279, p ≤ 0.05), shoulder/cranial (0.154 and 0.039, p ≤ 0.001), shoulder/central (0.231 and 0.039, p ≤ 0.001) and shoulder/caudal (0.185 and 0.026, p ≤ 0.001). The electric stunning also provided higher skin damage levels in the areas of the shoulder (1.098 and 0.795, p ≤ 0.001), body (1.04 and 0.948, p ≤ 0.05) and ham (0.84 and 0.68, p ≤ 0.001), as well as higher eyelid reflex levels (11.57%) comparatively to the gaseous system (2.86%) of a total of 426 pigs. Small indexes of bone fractures and muscle bruises were found in both systems.
Resumo:
Pigs of three genetics lineages A, B and C marketed in Brazil, with alive weight from 100 to 120 kg were submitted to the manual electric stunning (Karl Schermer 220-230/250 volts, 45-60 Hz and 1.4 -1.5 A) and to the collective gaseous system (COMBI-BUTINA 90% CO 2). Blood samples, for levels determination of creatine phosphokinase (CPK), lactate and cortisol, as well as samples of the semimembranosus muscle (10 g) for the determination of the gene halothane, were collected. Being compared the electric and gaseous stunning systems, the electric stunning did demonstrate to be more stressful providing larger plasmatic concentrations of cortisol (p ≤ 0.001) and lactate (p ≤ 0.001) for the genetic lineages A and C, in the studied conditions. However it didn't observe significant differences beween the sanguine indicators and stunning systems in subject when the lineage B was considered. Significant differences among the genetic lineages A, B and C were obtained being compared the plasmatic values of creatine phosphokinase (p ≤ 0.001), lactate (p ≤ 0.001) and cortisol (p ≤ 0.001) when stunned with the gaseous system, however when the electric system was used only the cortisol values presented significant differences (p ≤ 0.001). The presence of the gene halothane (Nn) was only observed in the lineage B.
Resumo:
Muscle fatigue can be a limiting factor to determine index as the electromyographic fatigue threshold (EMGFT) due the alterations in motivation and disconfots. This way, the purpose of this study was to identify the right biceps brachii and left biceps brachii obtained from repetitive elbow flexions at each 10% of total time. Nine healthy subjects performed the exercise named biceps curl until exhaustion with 25%, 35%, and 45% of one repetition maximum, in three different days. EMG amplitude (root mean square - RMS) was obtained for concentric contractions during these load levels and correlated with time to determine the slope values for each load and them detemine the EMGFT. The EMGFT was obtained within of each 10% of total time and they were compared by analysis of variance. The results showed a progressive increase in RMS with time, for both muscles in all loads, characterizing the muscle fatigue process, and for the EMGFT values ware not found predominantly significant differences between the execution time, as well as between muscles (right biceps × left biceps). This protocol allowed to identify the EMGFT to both muscles during the biceps curl, which was similar at different percentage of total time, indicating the possibility to reduce the length of the contraction test without the need to maintain the contraction until exhaustion. Further studies are needed to evaluate the applicability of this method to determining the effects on performance.
Resumo:
We often face Patients searching for rehabilitation for lower back disorders during the physiotherapeutic routine, and it is known that the abdominal muscle, specially the rectus abdominis muscle, aid the stabilization of the pelvis. Therefore, this paper analyzes the electrical activity of the rectus abdominis muscle in the pelvic retroversion in dorsal decubitus and in orthostatic position and in the lowering of the lower limbs. 30 healthy students, male and female, 17-40 yr, divided into two groups - Group 1: 15 volunteers (pelvic balance); Group 2 (pelvic unbalance) took part in this study. The electrical activity of the right and left supra-umbilical and infra-umbilical portions of the rectus abdominis muscle was detected. The mean RMS values from three attempts ftom the electromyographic traces were usedfor the analysis of the electrical activity. The RMS value was submitted to the normalization process. The data were submitted to statistic treatment by the Friedman test, and the analyses of the means and standard deviation towards a level of significance of 95%. The results demonstrated that the portions of the rectus abdominis muscle presented low electrical activity for the groups studiedfor pelvic retroversion either in dorsal decubitus or and orthostatic position. However, the decreasing movement of the lower limbs towards the portions of the rectus abdominis muscle presented more significant electrical activity whereas the lower portions presented higher activity than the higher ones for Group 2.
Resumo:
We investigated the effects of γ-radiation on cells isolated from the longitudinal smooth muscle layer of the guinea pig ileum, a relatively radioresistant tissue. Single doses (up to 50 Gy) reduced the amount of sarcoplasmatic reticulum and condensed the myofibrils, as shown by electron microscopy 3 days post-irradiation. After that, contractility of smooth muscle strips was reduced. Ca2+ handling was altered after irradiation, as shown in fura-2 loaded cells, with elevated basal intracellular Ca2+, reduced amount of intrareticular Ca2+, and reduced capacitive Ca2+ entry. Radiation also induced apoptosis, judged from flow cytometry of cells loaded with proprium iodide. Electron microscopy showed that radiation caused condensation of chromatin in dense masses around the nuclear envelope, the presence of apoptotic bodies, fragmentation of the nucleus, detachment of cells from their neighbors, and reductions in cell volume. Radiation also caused activation of caspase 12. Apoptosis was reduced by the administration of the caspase inhibitor Z-Val-Ala-Asp-fluoromethyl-ketone methyl ester (Z-VAD-FMK) during the 3 day period after irradiation, and by the chelator of intracellular Ca2+, 1,2-bis(o-aminophenoxy)-ethane-N,N,N′,N′-tetraacetic acid (BAPTA), from 1 h before until 2 h after irradiation. BAPTA also reduced the effects of radiation on contractility, basal intracellular Ca2+, amount of intrareticular Ca2+, capacitative Ca2+ entry, and apoptosis. In conclusion, the effects of gamma radiation on contractility, Ca2+ handling, and apoptosis appear due to a toxic action of intracellular Ca2+. Ca2+-induced damage to the sarcoplasmatic reticulum seems a key event in impaired Ca2+ handling and apoptosis induced by γ-radiation. © 2008 Elsevier B.V. All rights reserved.
Resumo:
It was purposed the use of electromyography (EMG) to evaluate the activation of the agonists and antagonists muscles of spastic patients, to test the viability in the development of an instrument that given quantitative data of the patient spasticity. 30 hemiplegic and 15 normal volunteers had been submitted to the EMG of flexor and extensor carpi ulnaris muscles during the flexion and extension movements of the wrist. The individuals with less severe spasticity (mAS (modified Ashworth Scale) ringing 0 to 3 degree), had presented deficit in the activation of the flexor muscles in plegic side in relation to the non plegic side and that the individuals seriously compromised by the spasticity (mAS = 4 degree) present deficit of reciprocal inhibition. One evidenced is that the non plegic member does not present a similar neuro-motor comportment when compared to the normal member. The surface electromyography is a practical clinical instrument to evaluate the patient with spasticity and the hemiplegic patient needs to be evaluated on both sides (deficient and no deficient) because the no compromised side do not show a normality standard.
Resumo:
Presently, acupuncture is a technique considered to be capable of stimulating the regulatory systems of the organism, such as the central nervous system, the endocrine system and the immunological system. The median frequency of the upper trapezium muscle with 40% and 60% of maximal voluntary contraction (MVC) of 15 healthy volunteers, was analyzed after the individuals were submitted to the AA treatment. The non-parametric Friedman test was used to compare median frequency values. In this exploratory study, the level of significance of each comparison was set to p < 0.05. The intraclass analyses indicate a significant increase of the median frequency muscle at 60% of the MVC (Wicoxon test). Based on the results found, the AA peripheral stimulus can act as a modulator mechanism of muscle activity and was possible to verify correspondence of the auricular acupoint with the trapezius muscle. © 2009 Elsevier Ltd. All rights reserved.
Resumo:
The effects of occlusal splint on the electric activity of masseter were studied in 15 women who presented sleep bruxism using surface electromyography. Sleep bruxism was defined by its clinical characteristics. The signal acquisition was done during mandible occlusion without clenching and maximum voluntary contraction in two situations. The first was after a workday without using the occlusal splint; and the second, after a sleeping night using occlusal splints. Evaluating masseter muscles during mandible occlusion without clenching, it could be observed that lower values were noticed after splint wearing in both sides. The same results were verified in maximum voluntary contraction (MVC). These results confirmed that the use of occlusal splints reduced the electromyographic activity of the right and left masseters, showing its myorelaxing effect. © 2009 Elsevier Ltd. All rights reserved.
Resumo:
Alteration of the occlusion and the position of the jaw can affect the muscles of the neck, due to a relationship between the masticatory and cervical systems. Thus, the objective of this study was to verify whether the bite in maximal clenching effort, in centric occlusion, in individuals with clinically normal occlusion, and without a history of dysfunction in the masticatory system, influences the electromyographic activity of the upper trapezius muscle. A total of 19 normal individuals participated in the study, 14 of which were women (average age of 25.4 ± 4.14 years), and 5 were men (average age of 24.11 ± 3.28 years). The root mean square (RMS) amplitude and median frequency (MF) of the upper trapezium muscle with 40% and 60% of maximal voluntary contraction were analyzed under pre- and post-maximal clenching effort conditions in centric occlusion. The electromyographic signal was collected with a sampling frequency of 2. kHz and the value in RMS was obtained by a moving window of 200. ms. The paired Student's t-test was used to compare RMS amplitude and MF under pre- and post-maximal clenching effort conditions. The level of significance for each comparison was set to p<0.05. This study concluded that in individuals without a history of dysfunction of the masticatory system, maximum clenching effort in centric occlusion does not alter the electromyographic signal of the upper trapezius. © 2009 Elsevier Ltd.
Resumo:
The aim of this study was to develop an experimental protocol for endurance swimming periodization training in rats similar to high performance training in humans, and compare it to continuous training. Three groups of male Wistar rats (90 days old) were allocated to Sedentary Control (SC); Continuous Training (CT); and Periodized Experimental Training (PET) groups. PET and CT trained 5 days/week, over five weeks, CT: continuous training supporting a 5% body mass (bm) load for 40 min/day; PET: training subdivided into basic, specific, and taper periods, with overload changed daily (volume-intensity, continuous, and interval training). Total training overload was quantified (% bm X exercise time in training session) and equalized for the two trained groups. Glucose ([ 3H]2-deoxyglucose) uptake, incorporation to glycogen (synthesis), glucose oxidation (CO 2 production), and lactate production from [U- 14C]glucose by soleus muscle strips incubated in presence of insulin (100μU/mL) were evaluated 48h after the last training session. The load equivalent at 5.5mM blood lactate concentration ([La-5.5]) was determined in the incremental test. Lactate production was similar in all groups. PET presented higher glucose uptake (59%) than SC, and higher glycogen synthesis (51 and 22%) and glucose oxidation (147 and 178%) than SC and CT, respectively. CT presented higher glycogen synthesis rates (23%) than SC. Load [La-5.5] was similar between trained groups and higher than SC. PET presented higher values for glucose metabolism than CT and SC. These results open up new perspectives for studying training methods used in high performance sport through swimming exercise in rats.
Resumo:
The use of low-level laser (LLL) may be an useful tool to promote reduction of muscular pain caused by TMD. Aim: This study evaluated the immediate efficacy of low-level laser therapy on women reporting pain and diagnosed with temporomandibular dysfunction (TMD). Methods: Diode laser (GaAlAs) at 790 nm wavelength (infrared spectrum) was applied as experimental treatment. Irradiations of 1.5 J/cm2 were made at 4 points of the temporomandibular joint (TMJ) and of 3 J/cm2 at 3 points in the temporal muscle. An electromyographic (EMG) evaluation of the masseter and anterior temporal was done at the following intervals: before, immediately after, 5 min and 20 min after laser application. Results: Comparison of the electrical activity at the times of measurement revealed a statistically significant difference in masseter muscles before (P=0.025) and immediately after (P=0.013) LLLT. Conclusions: Both masseter and temporal muscles showed a reduction in the measured EMG activities at all times after LLLT, and the temporal muscle showed higher EMG activity than the masseter muscle at all the evaluation times. LLLT caused significant immediate relaxation of the masseter muscles.
Resumo:
Purpose. Isokinetic tests are often applied to assess muscular strength and EMG activity, however the specific ranges of motion used in testing (fully flexed or extended positions) might be constrictive and/or be painful for patients with injuries or under-going rehabilitation. The aim of this study was to examine the effects of different ranges of motion (RoM) when determining maximal EMG during isokinetic knee flexion and extension with different types of contractions and velocities. Methods. Eighteen males had EMG activity recorded on the vastus lateralis, vastus medialis, semitendinosus and biceps femoris muscles during five maximal isokinetic concentric and eccentric contractions for the knee flexors and extensors at 60° • s -1 and 180° • s -1. The root mean square of EMG was calculated at three different ranges of motion: (1) a full range of motion (90°-20° [0° = full knee extension]); (2) a range of motion of 20° (between 60°-80° and 40°-60° for knee extension and flexion, respectively) and (3) at a 10° interval around the angle where peak torque is produced. EMG measurements were statistically analyzed (ANOVA) to test for the range of motion, contraction velocity and contraction speed effects. Coefficients of variation and Pearson's correlation coefficients were also calculated among the ranges of motion. Results. Predominantly similar (p > 0.05) and well-correlated EMG results (r > 0.7, p ≤ 0.001) were found among the ranges of motion. However, a lower coefficient of variation was found for the full range of motion, while the 10° interval around peak torque at 180° • s -1 had the highest coefficient, regardless of the type of contraction. Conclusions. Shorter ranges of motion at around the peak torque angle provides a reliable indicator when recording EMG activity during maximal isokinetic parameters. It may provide a safer alternative when testing patients with injuries or undergoing rehabilitation.
Resumo:
Aims: To evaluate the spatio-temporal variables of gait and the isometric muscle strength component of the ankle in patients with peripheral diabetic neuropathy. Also, verify the relationship between these variables and gait parameters. Methods: This study involved 25 diabetic peripheral neuropathy (DPN) participants (62.4 ± 8.36 years) and 27 age-matched healthy control individuals (64.48 ± 6.21 years). The assessment of the spatio-temporal parameters of gait was performed using an electronic baropodometry treadmill. Prior to the collection data, each participant was instructed to walk on the treadmill in her/his habitual self-selected speed. Results: Diabetic neuropathy group showed impairment of gait, with a smaller stride and length speed of the cycle, and increased duration of support time. Restricted dorsiflexion mobility and increased plantarflexion mobility were found, with a decrease in muscle strength of the dorsiflexors and plantiflexors. There was a significant relationship between plantiflexor muscle strength and the length and speed of the gait cycle. Also the muscle strengths of the plantiflexors and dorsiflexors, and the range of motion of dorsiflexion were predictors of gait performance. Conclusions: The ankle, muscle strength and ankle mobility variables could explain changes in gait speed and range of motion in patients with DPN, allowing for the application of preventive strategies. © 2012 Elsevier Ltd.