Resumo:
Bonded-in rod connections in timber possess many desirable attributes in terms of efficiency, manufacture, performance, aesthetics and cost. In recent years research has been conducted on such connections using fibre reinforced polymers (FRPs) as an alternative to steel. This research programme investigates the pull-out capacity of Basalt FRP rods bonded-in in low grade Irish Sitka Spruce. Embedded length is thought to be the most influential variable contributing to pull- out capacity of bonded-in rods after rod diameter. Previous work has established an optimum embedded length of 15 times the hole diameter. However, this work only considered the effects of axial stress on the bond using a pull-compression testing system which may have given an artificially high pull out capacity as bending effects were neglected. A hinge system was utilised that allows the effects of bending force to be taken in to consideration along with axial forces in a pull-out test. This paper describes an experimental programme where such pull-bending tests were carried out on samples constructed of 12mm diameter BFRP bars with a 2mm glueline thickness and embedded lengths between 80mm and 280mm bonded-in to low-grade timber with an epoxy resin. Nine repetitions of each were tested. A clear increase in pull-out strength was found with increasing embedded length.
Resumo:
The current eight published ISO standards associated with semiconductor photocatalysis are considered. These standards cover: (1) air purification (specifically, the removal of NO, acetaldehyde and toluene), (2) water purification (the photobleaching of methylene blue and oxidation of DMSO) (3) self-cleaning surfaces (the removal of oleic acid and subsequent change in water droplet contact angle), (4) photosterilisation (specifically probing the antibacterial action of semiconductor photocatalyst films) and (5) UV light sources for semiconductor photocatalytic ISO work. For each standard, the background is first considered, followed by a brief discussion of the standard particulars and concluding in a discussion of the pros and cons of the standard, with often recommendations for their improvement. Other possible standards for the future which would either compliment or enhance the current ones are discussed briefly.
Resumo:
This study explored the validity of using critical thinking tests to predict final psychology degree marks over and above that already predicted by traditional admission exams (A-levels). Participants were a longitudinal sample of 109 psychology students from a university in the United Kingdom. The outcome measures were: total degree marks; and end of year marks. The predictor measures were: university admission exam results (A-levels); critical thinking test scores (skills & dispositions); and non-verbal intelligence scores. Hierarchical regressions showed A-levels significantly predicted 10% of the final degree score and the 11-item measure of ‘Inference skills’ from the California Critical Thinking Skills Test significantly predicted an additional 6% of degree outcome variance. The findings from this study should inform decisions about the precise measurement constructs included in aptitude tests used in the higher education admission process.
Resumo:
In this paper, we propose new cointegration tests for single equations and panels. Inboth cases, the asymptotic distributions of the tests, which are derived with N fixed andT → ∞, are shown to be standard normals. The effects of serial correlation and crosssectionaldependence are mopped out via long-run variances. An effective bias correctionis derived which is shown to work well in finite samples; particularly when N is smallerthan T. Our panel tests are robust to possible cointegration across units.
Resumo:
The photocatalytic properties of self-cleaning acrylic paint containing TiO2 and ZnO were studied using Acid Orange 7 as a model compound. Paints were exposed to simulated weathering tests in a QUV panel. The initial photoactivity of the unweathered paints with ZnO was significantly higher. In the case of paints containing P25 the photocatalytic activity increases with weathering time, due to increasing destruction of the polymer resin and consequent exposure of the photocatalyst pigment to the Acid Orange 7 test solution. In contrast, in the case of paints containing ZnO, a decrease in photocatalytic activity is observed after weathering, due to the loss and/or photocorrosion of ZnO particles during the weathering process.
Resumo:
Automotive manufacturers require improved part load engine performance to further improve fuel economy. For a swing vane VGS (Variable Geometry Stator) turbine this means a more closed stator vane, to deal with the low MFRs (Mass Flow Rates), high PRs (Pressure Ratios) and low rotor rotational speeds. During these conditions the turbine is operating at low velocity ratios. As more energy is available at high pressure ratios and during lower turbocharger rotational speeds, a turbine which is efficient at these conditions is desirable. Another key aspect for automotive manufacturers is engine responsiveness. High inertia designs result in “turbo lag” which means an increased time before the target boost pressure is reached. Therefore, designs with improved performance at low velocity ratios, reduced inertia or an increased swallowing capacity are the current targets for turbocharger manufacturers.
To try to meet these design targets a CFD (Computational Fluid Dynamics) study was performed on a turbine wheel using splitter blades. A number of parameters were investigated. These included splitter blade merdional length, blade number and blade angle distribution.
The numerical study was performed on a scaled automotive VGS. Three different stator vane positions have been analysed. A single passage CFD model was developed and used to provide information on the flow features affecting performance in both the stator vanes and turbine.
Following the CFD investigation the design with the best compromise in terms of performance, inertia and increased MFP (Mass Flow Parameter) was selected for manufacture and testing. Tests were performed on a scaled, low temperature turbine test rig. The aerodynamic flow path of the gas stand was the same as that investigated during the CFD. The test results revealed a design which had similar performance at the closed stator vane positions when compared to the baseline wheel. At the maximum MFR stator vane condition a drop of −0.6% pts in efficiency was seen. However, 5.5% increase in MFP was obtained with the additional benefit of a drop in rotor inertia of 3.7%, compared to the baseline wheel.
Resumo:
This paper reports on the accuracy of new test methods developed to measure the air and water permeability of high-performance concretes (HPCs). Five representative HPC and one normal concrete (NC) mixtures were tested to estimate both repeatability and reliability of the proposed methods. Repeatability acceptance was adjudged using values of signal-noise ratio (SNR) and discrimination ratio (DR), and reliability was investigated by comparing against standard laboratory-based test methods (i.e., the RILEM gas permeability test and BS EN water penetration test). With SNR and DR values satisfying recommended criteria, it was concluded that test repeatability error has no significant influence on results. In addition, the research confirmed strong positive relationships between the proposed test methods and existing standard permeability assessment techniques. Based on these findings, the proposed test methods show strong potential to become recognized as international methods for determining the permeability of HPCs.
Resumo:
The properties of blood and the relative ease of access to which it can be retrieved make it an ideal source to gauge different aspects of homeostasis within an individual, form an accurate diagnosis, and formulate an appropriate treatment regime. Tests used to determine blood parameters such as the erythrocyte sedimentation rate, hemoglobin concentration, hematocrit, bleeding and clotting times, mean corpuscular hemoglobin, mean corpuscular hemoglobin concentration, mean cell volume, and determination of blood groups are routinely used clinically, and deviations outside the normal range can indicate a range of conditions such as anemia, pregnancy, dehydration, overhydration, infectious disease, cancer, thyroid disease, and autoimmune conditions, to mention a few. As these tests can be performed relatively inexpensively and do not require high levels of technical expertise, they are ideally suited for use in the teaching laboratory, enabling undergraduate students to link theory to practice. The practicals described here permit students to examine their own blood and that of their peers and compare these with clinically accepted normal ranges. At the end of the practicals, students are required to answer a number of questions about their findings and to link abnormal values to possible pathological conditions by answering a series of questions based on their findings.
Resumo:
Temperament tests are widely accepted as instruments for profiling behavioral variability in dogs, and they are applied in numerous areas of investigation (e.g. suitability for adoption or for breeding). During testing, to elicit a dog's reaction toward novel stimuli and predict its behavior in everyday life, model devices such as a child-like doll, or a fake dog, are often employed. However, the reliability of these devices to accurately stimulate dogs' reactions to children or dogs, is unknown and perhaps overestimated. This may be a particular concern in the case of aggressive behavior toward humans, a significant public health issue. The aim of this study was to: (1) evaluate the correlation between dogs' reactions to these devices, and owners' reports of their dog's aggression history (using the C-BARQ ??); (2) compare reactions toward the devices of dogs with and without histories of aggression. Subjects were selected among those visiting for behavioral consultation at the Veterinary Hospital of the University of Pennsylvania, and previously categorized as aggressive toward unfamiliar children, conspecifics, or as non-aggressive dogs (control). The test consisted of different components: an unfamiliar female tester approaching the dog; the presentation of a child-like doll, an ambiguous object, and a fake plastic dog. All tests were videotaped and durations of behaviors were later analyzed on the basis of a specified ethogram. Dogs' reactions were compared to C-BARQ scores, and interesting correlations emerged for 'dog-directed aggression/fear' (R = 0.48, P = 0.004), and 'stranger-directed aggression' (R = 0.58, P <0.001) factors. Dogs differed in their reactions toward the devices: the child-like doll and the fake dog elicited more social behaviors than the ambiguous object used as a control stimulus. Issues concerning the reliability of these tools to assess canine temperament are discussed. ?? 2012 Elsevier B.V. All rights reserved.
Resumo:
PURPOSE:
To assess the noneconomic value of tests used in the diagnosis and management of glaucoma, and explore the contexts and factors that determine such value.
DESIGN:
Perspective.
METHODS:
Selected articles from primary and secondary sources were reviewed and interpreted in the context of the authors' clinical and research experience, influenced by our perspectives on the tasks of reducing the global problem of irreversible blindness caused by glaucoma. The value of any test used in glaucoma is addressed by 3 questions regarding: its contexts, its kind of value, and its implicit or explicit benefits.
RESULTS:
Tonometry, slit-lamp gonioscopy, and optic disc evaluation remain the foundation of clinic-based case finding, whether in areas of more or less abundant resources. In resource-poor areas, there is urgency in identifying patients at risk for severe functional loss of vision; screening strategies have proven ineffective, and efforts are hindered by the inadequate allocation of support. In resource-abundant areas, the wider spectrum of glaucoma is addressed, with emphasis on early detection of structural changes of little functional consequence; these are increasingly the focus of new and expensive technologies whose clinical value has not been established in longitudinal and population-based studies. These contrasting realities in part reflect differences among the value ascribed, often implicitly, to the tests used in glaucoma.
CONCLUSIONS:
The value of any test is determined by 3 aspects: its context of usage; its comparative worth and to whom its benefit accrues; and how we define historically what we are testing. These multiple factors
Resumo:
Roadside safety barriers designs are tested with passenger cars in Europe using standard EN1317 in which the impact angle for normal, high and very high containment level tests is 20°. In comparison to EN1317, the US standard MASH has higher impact angles for cars and pickups (25°) and different vehicle masses. Studies in Europe (RISER) and the US have shown values for the 90th percentile impact angle of 30°–34°. Thus, the limited evidence available suggests that the 20° angle applied in EN 1317 may be too low.
The first goal of this paper is to use the US NCHRP database (Project NCHRP 17–22) to assess the distribution of impact angle and collision speed in recent ROR accidents. Second, based on the findings of the statistical analysis and on analysis of impact angles and speeds in the literature, an LS-DYNA finite element analysis was carried out to evaluate the normal containment level of concrete barriers in non-standard collisions. The FE model was validated against a crash test of a portable concrete barrier carried out at the UK Transport Research Laboratory (TRL).
The accident data analysis for run-off road accidents indicates that a substantial proportion of accidents have an impact angle in excess of 20°. The baseline LS-DYNA model showed good comparison with experimental acceleration severity index (ASI) data and the parametric analysis indicates a very significant influence of impact angle on ASI. Accordingly, a review of European run-off road accidents and the configuration of EN 1317 should be performed.