840 resultados para Distributed multimedia systems


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Simulation of large and complex systems, such as computing grids, is a difficult task. Current simulators, despite providing accurate results, are significantly hard to use. They usually demand a strong knowledge of programming, what is not a standard pattern in today's users of grids and high performance computing. The need for computer expertise prevents these users from simulating how the environment will respond to their applications, what may imply in large loss of efficiency, wasting precious computational resources. In this paper we introduce iSPD, iconic Simulator of Parallel and Distributed Systems, which is a simulator where grid models are produced through an iconic interface. We describe the simulator and its intermediate model languages. Results presented here provide an insight in its easy-of-use and accuracy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Networked control systems (NCS) are distributed control system where the sensors, actuators and controllers are physically separated and connected through communication networks. NCS represent the evolution of networked control architectures providing greater modularity and control decentralization, ease maintenance and diagnosis and lower cost of implementation. A recent trend in this research topic is the development of NCS using wireless networks (WNCS) enabling interoperability between existing wired and wireless systems. This paper evaluates a serial RS-232 ZigBee device as a wireless sensor link in NCS. In order to support this investigation, relevant performance metrics for wireless control applications such as jitter, time delay and messages lost are highlighted and calculated to evaluate the device capabilities. In addition the control performance of an implemented motor control system using the device is analyzed. Experimental results led to the conclusion that serial RS-232 ZigBee devices can be used to implement WNCS and the use of this device delay information in the PID controller discretization can improve the control performance of the system. © 2012 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Non-conventional database management systems are used to achieve a better performance when dealing with complex data. One fundamental concept of these systems is object identity (OID). Two techniques can be used for the implementation of OIDs: physical or logical. A logical implementation of OIDs, based on an Indirection Table, is used by NuGeM, a multimedia data manager kernel which is described in this paper. NuGeM Indirection Table allows the relocation of all pages in a database. The proposed strategy modifies the workings of this table so that it is possible to reduce considerably the number of I/O operations during the request and release of pages containing objects and their OIDs. Tests show a reduction of 84% in reading operations and a 67% reduction in writing operations when pages are requested. Although no changes were observed in writing operations during the release of pages, a 100% of reduction in reading operations was obtained. © 2012 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Traditionally, ancillary services are supplied by large conventional generators. However, with the huge penetration of distributed generators (DGs) as a result of the growing interest in satisfying energy requirements, and considering the benefits that they can bring along to the electrical system and to the environment, it appears reasonable to assume that ancillary services could also be provided by DGs in an economical and efficient way. In this paper, a settlement procedure for a reactive power market for DGs in distribution systems is proposed. Attention is directed to wind turbines connected to the network through synchronous generators with permanent magnets and doubly-fed induction generators. The generation uncertainty of this kind of DG is reduced by running a multi-objective optimization algorithm in multiple probabilistic scenarios through the Monte Carlo method and by representing the active power generated by the DGs through Markov models. The objectives to be minimized are the payments of the distribution system operator to the DGs for reactive power, the curtailment of transactions committed in an active power market previously settled, the losses in the lines of the network, and a voltage profile index. The proposed methodology was tested using a modified IEEE 37-bus distribution test system. © 1969-2012 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work, a mathematical model to analyze the impact of the installation and operation of dispersed generation units in power distribution systems is proposed. The main focus is to determine the trade-off between the reliability and operational costs of distribution networks when the operation of isolated areas is allowed. In order to increase the system operator revenue, an optimal power flow makes use of the different energy prices offered by the dispersed generation connected to the grid. Simultaneously, the type and location of the protective devices initially installed on the protection system are reconfigured in order to minimize the interruption and expenditure of adjusting the protection system to conditions imposed by the operation of dispersed units. The interruption cost regards the unsupplied energy to customers in secure systems but affected by the normal tripping of protective devices. Therefore, the tripping of fuses, reclosers, and overcurrent relays aims to protect the system against both temporary and permanent fault types. Additionally, in order to reduce the average duration of the system interruption experienced by customers, the isolated operation of dispersed generation is allowed by installing directional overcurrent relays with synchronized reclose capabilities. A 135-bus real distribution system is used in order to show the advantages of using the mathematical model proposed. © 1969-2012 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article shows a transmission line model developed directly in the phase domain. The proposed model is based on the relationships between the phase currents and voltages at both the sending and receiving ends of a single-phase line. These relationships, established using an ABCD matrix, were extended to multi-phase lines. The proposed model was validated by using it to represent a transmission line during short-and open-circuit tests. The results obtained with the proposed model were compared with results obtained with a classical model based on modal decomposition. These comparisons show that proposed model was correctly developed. © 2013 Taylor and Francis Group, LLC.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this article, the fuzzy Lyapunov function approach is considered for stabilising continuous-time Takagi-Sugeno fuzzy systems. Previous linear matrix inequality (LMI) stability conditions are relaxed by exploring further the properties of the time derivatives of premise membership functions and by introducing slack LMI variables into the problem formulation. The relaxation conditions given can also be used with a class of fuzzy Lyapunov functions which also depends on the membership function first-order time-derivative. The stability results are thus extended to systems with large number of rules under membership function order relations and used to design parallel-distributed compensation (PDC) fuzzy controllers which are also solved in terms of LMIs. Numerical examples illustrate the efficiency of the new stabilising conditions presented. © 2013 Copyright Taylor and Francis Group, LLC.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Eventos de raios nuvem-solo registrados pela rede de detecção do SIPAM, integrada por 12 sensores VAISALA LPATS IV, distribuídos no leste da Amazônia, foram analisados durante 4 tempestades com ocorrência de precipitação intensa em Belém-PA-Brasil, em 2006-2007. Esses casos selecionados, correspondem a eventos de chuva com mais de 25 mm/hora ou 40 mm/ 2 horas, de precipitação registrada por um pluviômetro instalado em 1º 47' 53" and 48º 30' 16" O. Com centro nessa localização, um círculos de 30, 10 e 5 km de raio foram traçados através de um sistema de informação geográfica e os dados de eventos de raios nessas áreas foram separados para analise. Durante essas tempestades, os eventos de raios ocorreram de maneira quase aleatória, sobre a área maior que já havia sido previamente coberta por sistemas convectivos de mesoescala, em todos os casos. Esse trabalho também mostrou a grande influencia dos sistemas de larga escala nas condições de tempo que levaram às tempestades severas estudadas. Adicionalmente, foi observado que, quando existe interação entre sistemas de larga e meso escalas, tanto a precipitação como o numero de relâmpagos aumentaram significativamente e a atividade elétrica nos círculos maiores pode anteceder a chuva no ponto central.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of the present article is to assess and compare the performance of electricity generation systems integrated with downdraft biomass gasifiers for distributed power generation. A model for estimating the electric power generation of internal combustion engines and gas turbines powered by syngas was developed. First, the model determines the syngas composition and the lower heating value; and second, these data are used to evaluate power generation in Otto, Diesel, and Brayton cycles. Four synthesis gas compositions were tested for gasification with: air; pure oxygen; 60% oxygen with 40% steam; and 60% air with 40% steam. The results show a maximum power ratio of 0.567 kWh/Nm(3) for the gas turbine system, 0.647 kWh/Nm(3) for the compression ignition engine, and 0.775 kWh/Nm(3) for the spark-ignition engine while running on synthesis gas which was produced using pure oxygen as gasification agent. When these three systems run on synthesis gas produced using atmospheric air as gasification agent, the maximum power ratios were 0.274 kWh/Nm(3) for the gas turbine system, 0.302 kWh/Nm(3) for CIE, and 0.282 kWh/Nm(3) for SIE. The relationship between power output and synthesis gas flow variations is presented as is the dependence of efficiency on compression ratios. Since the maximum attainable power ratio of CIE is higher than that of SIE for gasification with air, more research should be performed on utilization of synthesis gas in CIE. (C) 2014 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Anatomically preserved calamitalean trunks are described from the Permian fossil forests of Chemnitz, Germany, and Tocantins, central-north Brazil. Several trunk bases were found in situ, still rooting in their former substrate or in parautochthonous sediments and revealing multiple organic connections between stems and roots. The new evidence of several free-stemmed Permian calamitaleans from different fossil lagerstatten and different taphonomic modes from the Northern and Southern hemispheres has implications for understanding calamite growth and challenges the universal validity of the reconstruction of rhizome-bearing woody trees. Whereas the stems belong to different species of the widely distributed genus Arthropitys GOEPPERT 1864, among them the generitype A. bistriata (COTTA) emend. RoSSLER, FENG & NOLL 2012 the attached roots represent the largest calamite roots ever found and incorporate a broad spectrum of preservational forms and ontogenetic stages. The latter are represented by the root genera Astromyelon WILLIAMSON 1878, Myriophylloides HICK & CASH 1881 and Asthenomyelon LEISTIKOW 1962 that were evidenced for the first time from Chemnitz, the type locality of Arthropitys and Calamitea (COTTA) emend. ROSSLER & NOLL 2007. Branched, stem-borne, adventitious root systems exhibit similar architectures, arise from different nodes of the lowermost trunks and anchor the trees in' different substrates. Developmental features were analysed in first- to third-order roots, which possess clearly-defined concentric tissue zones: epidermis/periderm, cortex, endodermis and central vascular tissue with or without pith. First-order roots, in particular, show considerable secondary growth. Numerous zones of concentric density variation in the secondary xylem indicate some kind of seasonality in the early Permian environments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In a smart grid environment, attention should be paid not only to the power supplied to satisfy loads and system losses but also to the services necessary to provide security and stability to the system: the so-called ancillary services. As they are well known the benefits that distributed generation can bring to electrical systems and to the environment, in this work the possibility that active power reserve for frequency control could be provided by distributed generators (DGs) in an efficient and economical way is explored. The proposed methodology was tested using the IEEE 34-bus distribution test system. The results show improvements in the capacity of the system for this ancillary service and decrease in system losses and payments of the distribution system operator to the DGs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Networked control systems (NCSs) are distributed control system in which sensors, actuators and controllers are physically separated and connected through communication networks. NCS represent the evolution of networked control architectures providing greater modularity and control decentralization, ease maintenance and diagnosis and lower cost of implementation. A recent trend in this research topic is the development of NCS using wireless networks(WNCS)which enable interoperability between existing wiredand wireless systems. This paper presents the feasibility analysis of using serial to wireless converter as a wireless sensor link in NCS. In order to support this investigation, relevant performance metrics for wireless control applications such as jitter, time delay and messages lost are highlighted and calculated to evaluate the wireless converter capabilities. In addition the control performance of an implemented motor control system using the converter is analyzed. Experimental results led to the conclusion that serial ZigBee device isrecommended against the Bluetooth as it provided better metrics for control applications. However, bothdevices can be used to implement WNCS providing transmission rates and closed control loop times which are acceptable for NCS applications.Moreoverthe use of thewireless device delay in the PID controller discretization can improve the control performance of the system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Access control is a fundamental concern in any system that manages resources, e.g., operating systems, file systems, databases and communications systems. The problem we address is how to specify, enforce, and implement access control in distributed environments. This problem occurs in many applications such as management of distributed project resources, e-newspaper and payTV subscription services. Starting from an access relation between users and resources, we derive a user hierarchy, a resource hierarchy, and a unified hierarchy. The unified hierarchy is then used to specify the access relation in a way that is compact and that allows efficient queries. It is also used in cryptographic schemes that enforce the access relation. We introduce three specific cryptography based hierarchical schemes, which can effectively enforce and implement access control and are designed for distributed environments because they do not need the presence of a central authority (except perhaps for set- UP).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, a modeling technique for small-signal stability assessment of unbalanced power systems is presented. Since power distribution systems are inherently unbalanced, due to its lines and loads characteristics, and the penetration of distributed generation into these systems is increasing nowadays, such a tool is needed in order to ensure a secure and reliable operation of these systems. The main contribution of this paper is the development of a phasor-based model for the study of dynamic phenomena in unbalanced power systems. Using an assumption on the net torque of the generator, it is possible to precisely define an equilibrium point for the phasor model of the system, thus enabling its linearization around this point, and, consequently, its eigenvalue/eigenvector analysis for small-signal stability assessment. The modeling technique presented here was compared to the dynamic behavior observed in ATP simulations and the results show that, for the generator and controller models used, the proposed modeling approach is adequate and yields reliable and precise results.