995 resultados para Cu ion implantation
Resumo:
Ce cas décrit les enjeux politiques soulevés au moment de la mise en oeuvre d'une politique gouvernementale visant l'amélioration des services de santé. [Auteurs]
Resumo:
BACKGROUND Very few data exist on the clinical impact of permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation. The objective of this study was to assess the impact of PPI after transcatheter aortic valve implantation on late outcomes in a large cohort of patients. METHODS AND RESULTS A total of 1556 consecutive patients without prior PPI undergoing transcatheter aortic valve implantation were included. Of them, 239 patients (15.4%) required a PPI within the first 30 days after transcatheter aortic valve implantation. At a mean follow-up of 22±17 months, no association was observed between the need for 30-day PPI and all-cause mortality (hazard ratio, 0.98; 95% confidence interval, 0.74-1.30; P=0.871), cardiovascular mortality (hazard ratio, 0.81; 95% confidence interval, 0.56-1.17; P=0.270), and all-cause mortality or rehospitalization for heart failure (hazard ratio, 1.00; 95% confidence interval, 0.77-1.30; P=0.980). A lower rate of unexpected (sudden or unknown) death was observed in patients with PPI (hazard ratio, 0.31; 95% confidence interval, 0.11-0.85; P=0.023). Patients with new PPI showed a poorer evolution of left ventricular ejection fraction over time (P=0.017), and new PPI was an independent predictor of left ventricular ejection fraction decrease at the 6- to 12-month follow-up (estimated coefficient, -2.26; 95% confidence interval, -4.07 to -0.44; P=0.013; R(2)=0.121). CONCLUSIONS The need for PPI was a frequent complication of transcatheter aortic valve implantation, but it was not associated with any increase in overall or cardiovascular death or rehospitalization for heart failure after a mean follow-up of ≈2 years. Indeed, 30-day PPI was a protective factor for the occurrence of unexpected (sudden or unknown) death. However, new PPI did have a negative effect on left ventricular function over time.
Resumo:
BACKGROUND It is unknown if lack of polymer can provoke a different edge response in drug-eluting stents. The aim of this study was to compare edge vascular response between polymer-free paclitaxel-eluting stent (PF-PES) and polymer-based paclitaxel-eluting stents (PB-PES). METHODS AND RESULTS: A total of 165 eligible patients undergoing percutaneous coronary intervention were prospectively randomized 1:1 to receive either PF-PES or PB-PES. Those patients with paired intravascular ultrasound (IVUS) after procedure and at 9-month follow-up were included in this analysis.Seventy-six patients with 84 lesions, divided into PB-PES (38 patients, 41 lesions) and PF-PES groups (38 patients, 43 lesions) had paired post-procedure and 9-month follow-up IVUS and were therefore included in this substudy. There was a significant lumen decrease at the proximal edge of PF-PES (from 9.02±3.06 mm(2)to 8.47±3.05 mm(2); P=0.040), and a significant plaque increase at the distal edges of PF-PES (from 4.39±2.73 mm(2)to 4.78±2.63 mm(2); P=0.004). At the distal edge there was a significant plaque increase in the PF-PES compared to PB-PES (+8.0% vs. -0.6%, respectively; P=0.015) with subsequent lumen reduction (-5.2% vs. +6.0%, respectively; P=0.024). CONCLUSIONS PF-PES had significant plaque increase and lumen reduction at the distal edge as compared to PB-PES, probably due to difference in polymer-based drug-release kinetics between the 2 platforms.
Resumo:
There is controversy over the use of the Ross procedure with regard to the sub-coronary and root replacement technique and its long-term durability. A systematic review of the literature may provide insight into the outcomes of these two surgical subvariants. A systematic review of reports between 1967 and February 2013 on sub-coronary and root replacement Ross procedures was undertaken. Twenty-four articles were included and divided into (i) sub-coronary technique and (ii) root replacement technique. The 10-year survival rate for a mixed-patient population in the sub-coronary procedure was 87.3% with a 95% confidence interval (CI) of 79.7-93.4 and 89.1% (95% CI, 85.3-92.1) in the root replacement technique category. For adults, it was 94 vs 95.3% (CI, 88.9-98.1) and in the paediatric series it was 90 vs 92.7% (CI, 86.9-96.0), respectively. Freedom from reoperation at 10 years was, in the mixed population, 83.3% (95% CI, 69.9-93.4) and 93.3% (95% CI, 89.4-95.9) for sub-coronary versus root replacement technique, respectively. In adults, it was 98 vs 91.2% (95% CI, 82.4-295.8), and in the paediatric series 93.3 vs 92.0% (95% CI, 86.1-96.5) for sub-coronary versus root replacement technique, respectively. The Ross procedure arguably has satisfactory results over 5 and 10 years for both adults and children. The results do not support the advantages of the sub-coronary technique over the root replacement technique. Root replacement was of benefit to patients undergoing reoperations on neoaorta and for long-term survival in mixed series.
Resumo:
Background: The glycosylated hemoglobin (HbA1c) is used to help monitor the degree of a diabetic’s hyperglycemia. Security and accuracy of the methods used in its detection are affected by variants forms of Hb or elevations in levels of Fetal Hb (HbF). These interference are the result of a change in the haemoglobin total net charge of the variant due of a substitution of one amino acid in the remaining amino terminal of the beta chain. International Standardization for HbA1c values (NGSP) not include interference assessment as part of the certification program. Therefore, the effect of each variant or the lifting of the HbF on HbA1c result should be examined in each sample depending on the detected variant and the method used for the detection of the same. The objectives were: to describe the possible variants of Hb and their interference in HbA1c measurement by our method, after the implementation of a computer program for their detection. To identify some variants detected by chromatography liquid ion exchange high resolution (HPLC) with DNA molecular sequencing.
Resumo:
OBJECTIVE To evaluate immediate transcatheter aortic valve implantation (TAVI) results and medium-term follow-up in very elderly patients with severe and symptomatic aortic stenosis (AS). METHODS This multicenter, observational and prospective study was carried out in three hospitals. We included consecutive very elderly (> 85 years) patients with severe AS treated by TAVI. The primary endpoint was to evaluate death rates from any cause at two years. RESULTS The study included 160 consecutive patients with a mean age of 87 ± 2.1 years (range from 85 to 94 years) and a mean logistic EuroSCORE of 18.8% ± 11.2% with 57 (35.6%) patients scoring ≥ 20%. Procedural success rate was 97.5%, with 25 (15.6%) patients experiencing acute complications with major bleeding (the most frequent). Global mortality rate during hospitalization was 8.8% (n = 14) and 30-day mortality rate was 10% (n = 16). Median follow up period was 252.24 ± 232.17 days. During the follow-up period, 28 (17.5%) patients died (17 of them due to cardiac causes). The estimated two year overall and cardiac survival rates using the Kaplan-Meier method were 71% and 86.4%, respectively. Cox proportional hazard regression showed that the variable EuroSCORE ≥ 20 was the unique variable associated with overall mortality. CONCLUSIONS TAVI is safe and effective in a selected population of very elderly patients. Our findings support the adoption of this new procedure in this complex group of patients.
Resumo:
El SPION (Super Paramagnetic Iron Oxide Nanoparticles) ha estat estudiat com un nou adsorbent per eliminar l’arsènic d’aigües contaminades. Les condicions òptimes de treball es van assolir per un pH de 3,6 i per concentracions inferiors als 100ppm. No es van trobar interferències significatives produïdes pels cations Cu, Ni i Zn en l’adsorció de l’As, sent el fosfat l’anió que més interfereix. Una esponja de cel·lulosa s’ha utilitzat com a suport del SPION, per disminuir les agregacions de les nanopartícules en suspensió i per proporcionar una material adequat per l’adsorció en continu, experiment amb columnes. Així, es va obtenir un augment de la capacitat d’adsorció del SPION per l’As(V), mentre que per l’As(III) continua sent baixa, per tant s’augmenta la selectivitat per l’As(V). Les interferències aniòniques afecten d’igual manera a l’adsorció de l’As(III) i l’As(V) quan l’adsorció és en continu o en discontinu. Els cations metàl·lics no interfereixen en l’adsorció de l’arsènic, a excepció del coure que és adsorbit i porta a la disminució de l’adsorció d’arsènic.
Resumo:
The Guelb Moghrein Fe oxide-Cu-Au-Co deposit is located at the western boundary of the West African craton in NW Mauritania. The wall rocks to the mineralization represent a meta-volcanosedimentary succession typical of Archaean greenstone belts. Two types of meta-volcanic rocks are distinguished: (1) volcanoclastic rocks of rhyodacite-dacite composition (Sainte Barbe volcanic unit), which form the stratigraphic base; (2) tholeiitic andesites-basalts (Akjoujt meta-basalt unit). The trace element signature of both types is characteristic of a volcanic arc setting. A small meta-pelitic division belongs to the Sainte Barbe volcanic unit. A meta-carbonate body, which contains the mineralization, forms a tectonic lens in the Akjoujt meta-basalt unit. It can be defined by the high X(mg) (=36) of Fe-Mg carbonate, the REE pattern and the delta(13)C values of -18 to -17 parts per thousand as a marine precipitate similar to Archaean banded iron formation (BIF). Additionally, small slices of Fe-Mg clinoamphibole-chlorite schist in the meta-carbonate show characteristics of marine shale. This assemblage, therefore, does not represent an alteration product, but represents an iron formation unit deposited on a continental shelf, which probably belongs to the Lembeitih Formation. The hydrothermal mineralization at 2492 Ma was contemporaneous with regional D(2) thrusting of the Sainte Barbe volcanic unit and imbrications of the meta-carbonate in the upper greenschist facies. This resulted in the formation of an ore breccia in the meta-carbonate, which is enriched in Fe, Ni, Co, Cu, Bi, Mo, As and Au. Massive sulphide ore breccia contains up to 20 wt% Cu. The ore fluid was aqueous-carbonic in nature and either changed its composition from a Mg-rich oxidizing to an Fe-rich reducing fluid or the two fluid types mixed at the trap site. All lithologies at Guelb Moghrein were deformed by D(3) thrusting to the east in the lower greenschist facies. The mobility of REE in the retrogressed rocks explains the formation of a second generation of hydrothermal monazite, which was dated at c. 1742 Ma. Archaean rocks of the West African craton extend to the west to Guelb Moghrein. The active continental margin was deformed and mineralized in the Late Archaean-Early Proterozoic and again reactivated in the Mid-Proterozoic and Westphalian, showing that the western boundary of the craton was reactivated several times.
Resumo:
La síntesis mecánica es un proceso basado en la molturación de una mezcla de polvosometida a altas energías que se producen por los choques entre las partículas y lasbolas de un micromolino, entre las partículas y las paredes del recipiente y entre lasmismas partículas. Los dos procesos involucrados en el proceso de síntesis mecánicason la soldadura en frío y la fractura.El proyecto que se presenta es una continuación de los diferentes estudios realizadosen el departamento de Recerca de Materials i Termodinàmica de la Universidad deGirona sobre el proceso de aleado mecánico, en especial del proyecto de Ivan Darnés(Abril 2005) donde se realizaba un estudio comparativo de los micromolinosPulverisette 7 (P7) y SPEX8000 a partir de dos aleaciones en polvo de base Fe.El presente proyecto tiene como objetivo principal realizar nuevamente unacomparación de los equipos P7 y SPEX8000, pero utilizando otras mezclas de polvoiniciales y modificando los parámetros del proceso. Para tal comparación se estudiaránlas muestras obtenidas a nivel estructural, térmico y morfológico
Resumo:
Background: Cardiac computed tomographic scans, coronary angiograms, and aortographies are routinely performed in transcatheter heart valve therapies. Consequently, all patients are exposed to multiple contrast injections with a following risk of nephrotoxicity and postoperative renal failure. The transapical aortic valve implantation without angiography can prevent contrast-related complications. Methods: Between November 2008 and November 2009, 30 consecutive high-risk patients (16 female, 53.3%) underwent transapical aortic valve implantation without angiography. The landmarks identification, the stent-valve positioning, and the postoperative control were routinely performed under transesophageal echocardiogram and fluoroscopic visualization without contrast injections. Results: Mean age was 80.1 +/- 8.7 years. Mean valve gradient, aortic orifice area, and ejection fraction were 60.3 +/- 20.9 mm Hg, 0.7 +/- 0.16 cm(2), and 0.526 +/- 0.128, respectively. Risk factors were pulmonary hypertension (60%), peripheral vascular disease (70%), chronic pulmonary disease (50%), previous cardiac surgery (13.3%), and chronic renal insufficiency (40%) (mean blood creatinine and urea levels: 96.8 +/- 54 mu g/dL and 8.45 +/- 5.15 mmol/L). Average European System for Cardiac Operative Risk Evaluation was 32.2 +/- 13.3%. Valve deployment in the ideal landing zone was 96.7% successful and valve embolization occurred once. Thirty-day mortality was 10% (3 patients). Causes of death were the following: intraoperative ventricular rupture (conversion to sternotomy), right ventricular failure, and bilateral pneumonia. Stroke occurred in one patient at postoperative day 9. Renal failure (postoperative mean blood creatinine and urea levels: 91.1 +/- 66.8 mu g/dL and 7.27 +/- 3.45 mmol/L), myocardial infarction, and atrioventricular block were not detected. Conclusions: Transapical aortic valve implantation without angiography requires a short learning curve and can be performed routinely by experienced teams. Our report confirms that this procedure is feasible and safe, and provides good results with low incidence of postoperative renal disorders. (Ann Thorac Surg 2010; 89: 1925-33) (C) 2010 by The Society of Thoracic Surgeons
Resumo:
Acid-sensing ion channels (ASICs) are neuronal Na(+) channels that belong to the epithelial Na(+) channel/degenerin family. ASICs are transiently activated by a rapid drop in extracellular pH. Conditions of low extracellular pH, such as ischemia and inflammation in which ASICs are thought to be active, are accompanied by increased protease activity. We show here that serine proteases modulate the function of ASIC1a and ASIC1b but not of ASIC2a and ASIC3. We show that protease exposure shifts the pH dependence of ASIC1a activation and steady-state inactivation to more acidic pH. As a consequence, protease exposure leads to a decrease in current response if ASIC1a is activated by a pH drop from pH 7.4. If, however, acidification occurs from a basal pH of approximately 7, protease-exposed ASIC1a shows higher activity than untreated ASIC1a. We provide evidence that this bi-directional regulation of ASIC1a function also occurs in neurons. Thus, we have identified a mechanism that modulates ASIC function and may allow ASIC1a to adapt its gating to situations of persistent extracellular acidification.
Resumo:
Rapport de synthèseObjectif: le remplacement valvulaire aortique par voie transcathétère est, actuellement, une méthode fiable indiquée pour des patients à haut risque porteurs d'une sténose valvulaire aortique. La voie transfémorale est utilisable seulement en cas d'absence de maladie vasculaire et la voie transapicale est contrindiquée en cas de dysfonction pulmonaire chronique sévère. Une alternative pour ne pas passer a travers l'espace pleural serait par voie sous- xiphoïdienne et trans-septale à travers le ventricule droit.Méthode: une expérience animale a été amené au laboratoire de recherche du CHUV. Cinq cochons (poids : 52.3±10.9 kg) ont été endormi et, sous anesthésie générale, le ventricule droit a été préparé a travers un accès sous- xiphoïdien. Ensuite, sous guide fluoroscopique et avec l'utilisation d'une échocardiographie intracardiaque, un accès trans-septal a été crée entre le ventricule droit et le ventricule gauche en utilisant des dilatateur de diamètre croissant (de 8F à 26F). Par la suite, une valve stentée crée dans le laboratoire en utilisant un stent en nitinol et du péricarde a été chargé dans une cartouche et introduite dans le ventricule gauche à travers un introducteur trans-septal. Enfin, la valve a été amené dans la chambre de chasse du ventricule gauche et ensuite dans la racine aortique et puis déployé au bon endroit. Quand le système a été retiré, le septum ventriculaire a pu être réparé par mise en place d'un système d'occlusion septal Amplazer. Trente minutes après la procédure, les animaux ont été sacrifié et le coeur a été analysé pour étudier le positionnement da la valve stentée, l'efficacité de la fermeture du septum inter-ventriculaire et la fermeture de la paroi du ventricule droit.Résultat : les cinq cochon ont tous eu un parfait positionnement et pose de la prothèse en position aortique au premier essai (efficacité 100%). Les procédures ont duré, moyennement, 49±4 minutes et la progressive dilatation de l'accès trans-septale à donné lieu à une communication inter-ventriculaire mesurable après dilatation avec du 18F et plus. Toutes les valves stentées ont été déployées au bon endroit avec un bon résultat du fonctionnement des valves prothétiques et absence d'insuffisance para prothétique. Pendant les procédures, des battement prématurés ainsi que des épisodes isolées de tachycardie supra ventriculaire ont été détectés. Par contre, il n'y a pas eu de bloc atrio-ventriculaire. Les pertes sanguines pendant les procédures étaient de 280±10mL, et les systèmes d'occlusion Amplatzer étaient tous bien déployés sans shunts inter-ventriculaires résiduels.Conclusion: la technique d'introduction de valve stentées par voie extrapleural (trans-ventriculaire et trans-septale) est techniquement possible et elle jette les bases pour le remplacement valvulaire aortique trans-ventriculaire sous anesthésie locale.
Resumo:
Objective: To analyze the vascularization of the endometrium via hysteroscopy and to assess its correlation with angiogenic factor gene expression and embryo implantation rate.Design: Cross-sectional study.Setting: Public university hospital.Patient(s): Patients undergoing hysteroscopy for supposed infertility.Intervention(s): Endometrial quality assessment according to Sakumoto-Masamoto, performed in the early secretory phase of the cycle. Collection of an endometrial tissue biopsy.Main Outcome Measure(s): RNA extraction, reverse transcription, and determination of gene expression of angiogenesis- and implantation-relevant factors using quantitative polymerase chain reaction. Retrieval of pregnancy information from the medical records.Result(s): Good quantity/quality RNA with infertility history was obtained from 63 participating women. Those with a "good" endometrium and subsequent pregnancy showed increased gene expression for placenta growth factor when compared with patients with a "bad" endometrium and who did not succeed with pregnancy to date. Nonpregnant women with a "good" endometrium presented an intermediate result. No significant differences were observed for several other genes tested, but trends in the same direction were observed.Conclusion(s): This study demonstrates for the first time that endometrial PLGF expression corresponds to the hysteroscopic appearance of the endometrium, and therefore has potential as a clinically relevant prognosticator for infertility treatment success. (Fertil Steril (R) 2011;96:663-8. (C)2011 by American Society for Reproductive Medicine.)