913 resultados para Corneal biomechanics


Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Collateral damage to upper eyelid margin during proton beam radiotherapy (PBR) for choroidal melanoma may cause squamous metaplasia of the tarsal conjunctiva with keratinisation, corneal irritation, discomfort and, rarely, corneal perforation. We evaluated transpalpebral PBR as a means of avoiding collateral damage to the upper eyelid margin without increasing the risk of failure of local tumour control. METHODS: Retrospective study of consecutive patients who underwent PBR for choroidal melanoma between 1992 and 2007 at the Royal Liverpool University Hospital and the Douglas Cyclotron at Clatterbridge Cancer Centre, UK. RESULTS: Sixty-three patients were included in this study. Mean basal tumour diameter and tumour thickness were 11.8 mm and 3.6 mm, respectively. PBR mean beam range and modulation were 26.5 mm and 16.9 mm respectively. The eyelid margin was included in the radiation field in 15 (24%) eyes. The median follow-up was 2.5 years. Local tumour recurrence developed in 2 (3.2%) patients. In these two cases that developed tumour recurrence the transpalpebral treatment did not involve the eyelid margin. Six (9.5%) patients died of metastatic disease. No eyelid or ocular surface problems developed in any of the 48 patients who were treated without eyelid rim involvement, while 7 of the 15 patients with unavoidable irradiation of the eyelid rim developed some degree of madarosis. These seven patients all received more than 26.55 proton Gy to the eyelid margin. Symptoms, such as grittiness occurred in 12% of 48 patients without eyelid margin irradiation as compared with 53% of 15 patients whose lid margin was irradiated. CONCLUSIONS: Transpalpebral PBR of choroidal melanoma avoids eyelid and ocular surface complications without increasing failure of local tumour control.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The joint angles of multi-segment foot models have been primarily described using two mathematical methods: the joint coordinate system and the attitude vector. This study aimed to determine whether the angles obtained through these two descriptors are comparable, and whether these descriptors have similar sensitivity to experimental errors. Six subjects walked eight times on an instrumented walkway while the joint angles among shank, hindfoot, medial forefoot, and lateral forefoot were measured. The angles obtained using both descriptors and their sensitivity to experimental errors were compared. There was no overall significant difference between the ranges of motion obtained using both descriptors. However, median differences of more than 6° were noticed for the medial-lateral forefoot joint. For all joints and rotation planes, both descriptors provided highly similar angle patterns (median correlation coefficient: R>0.90), except for the medial-lateral forefoot angle in the transverse plane (median R=0.77). The joint coordinate system was significantly more sensitive to anatomical landmarks misplacement errors. However, the absolute differences of sensitivity were small relative to the joints ranges of motion. In conclusion, the angles obtained using these two descriptors were not identical, but were similar for at least the shank-hindfoot and hindfoot-medial forefoot joints. Therefore, the angle comparison across descriptors is possible for these two joints. Comparison should be done more carefully for the medial-lateral forefoot joint. Moreover, despite different sensitivities to experimental errors, the effects of the experimental errors on the angles were small for both descriptors suggesting that both descriptors can be considered for multi-segment foot models.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The malformations in the amniotic band syndrome (ABS) are due to entrapment of fetal parts by fibrous band in the amniotic sac. Limbs are most commonly affected followed by craniofacial defects in one third of patients. Ocular defects include corneal leukomas and lid colobomas often contiguous with facial clefts, strabismus, hypertelorism, and microphthalmos. Unilateral chorioretinal defects or lacunae are rare findings in the ABS. We report a female infant with such a lacunar defect along with central nervous abnormalities, and discuss the differential diagnosis and the embryopathic implications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the present review, microvascular remodelling refers to alterations in the structure of resistance vessels contributing to elevated systemic vascular resistance in hypertension. We start with some historical aspects, underscoring the importance of Folkow's contribution made half a century ago. We then move to some basic concepts on the biomechanics of blood vessels, and explicit the definitions proposed by Mulvany for specific forms of remodelling, especially inward eutrophic and inward hypertrophic. The available evidence for the existence of remodelled resistance vessels in hypertension comes next, with relatively more weight given to human, in comparison with animal data. Mechanisms are discussed. The impact of antihypertensive drug treatment on remodelling is described, again with emphasis on human data. Some details are given on the three studies to date which point to remodelling of subcutaneous resistance arteries as an independent predictor of cardiovascular risk in hypertensive patients. We terminate by considering the potential role of remodelling in the pathogenesis of end-organ damage and in the perpetuation of hypertension.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Wilson disease (WD) is an inherited disorder of hepatic copper excretion leading to toxic accumulation of copper in the liver as well as the brain, cornea, and other organs. The defect is due to mutations of the copper-transporting ATPase ATP7B. Clinical manifestations are highly variable and comprise acute liver failure, chronic hepatitis and cirrhosis as well as neurological or psychiatric symptoms. The Kayser-Fleischer corneal ring is pathognomonic but absent in about 50% of patients with hepatic manifestations alone. A high index of suspicion in clinically compatible situations is key, with a combination of laboratory tests allowing the diagnosis of WD. Treatment is based on the use of chelating agents, D-penicillamine or trientine. Liver transplantation should be considered for patients with acute liver failure or advanced cirrhosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The interfacial micromotion is closely associated to the long-term success of cementless hip prostheses. Various techniques have been proposed to measure them, but only a few number of points over the stem surface can be measured simultaneously. In this paper, we propose a new technique based on micro-Computer Tomography (μCT) to measure locally the relative interfacial micromotions between the metallic stem and the surrounding femoral bone. Tantalum beads were stuck at the stem surface and spread at the endosteal surface. Relative micromotions between the stem and the endosteal bone surfaces were measured at different loading amplitudes. The estimated error was 10μm and the maximal micromotion was 60μm, in the loading direction, at 1400N. This pilot study provided a local measurement of the micromotions in the 3 direction and at 8 locations on the stem surface simultaneously. This technique could be easily extended to higher loads and a much larger number of points, covering the entire stem surface and providing a quasi-continuous distribution of the 3D interfacial micromotions around the stem. The new measurement method would be very useful to compare the induced micromotions of different stem designs and to optimize the primary stability of cementless total hip arthroplasty.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the last few years, some of the visionary concepts behind the virtual physiological human began to be demonstrated on various clinical domains, showing great promise for improving healthcare management. In the current work, we provide an overview of image- and biomechanics-based techniques that, when put together, provide a patient-specific pipeline for the management of intracranial aneurysms. The derivation and subsequent integration of morphological, morphodynamic, haemodynamic and structural analyses allow us to extract patient-specific models and information from which diagnostic and prognostic descriptors can be obtained. Linking such new indices with relevant clinical events should bring new insights into the processes behind aneurysm genesis, growth and rupture. The development of techniques for modelling endovascular devices such as stents and coils allows the evaluation of alternative treatment scenarios before the intervention takes place and could also contribute to the understanding and improved design of more effective devices. A key element to facilitate the clinical take-up of all these developments is their comprehensive validation. Although a number of previously published results have shown the accuracy and robustness of individual components, further efforts should be directed to demonstrate the diagnostic and prognostic efficacy of these advanced tools through large-scale clinical trials.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The development and maintenance of excess body mass in many children is partly attributable to levels of physical activity that are lower than the recommended 60 minutes/day. Walking is a recommended form of physical activity for obese children, due to its convenience and perceived ease of adoption. Unfortunately, studies that have used objective physical activity assessment continue to report low step counts and levels of physical activity in obese children. This may be due to physiological and/or biomechanical factors that make walking more difficult for obese children. The purpose of this review is to highlight the current recommended and measured levels of physical activity for children and to discuss the physiological and biomechanical challenges of walking for obese children that may help explain why these children are not meeting physical activity goals.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the last few years, there has been a growing focus on faster computational methods to support clinicians in planning stenting procedures. This study investigates the possibility of introducing computational approximations in modelling stent deployment in aneurysmatic cerebral vessels to achieve simulations compatible with the constraints of real clinical workflows. The release of a self-expandable stent in a simplified aneurysmatic vessel was modelled in four different initial positions. Six progressively simplified modelling approaches (based on Finite Element method and Fast Virtual Stenting – FVS) have been used. Comparing accuracy of the results, the final configuration of the stent is more affected by neglecting mechanical properties of materials (FVS) than by adopting 1D instead of 3D stent models. Nevertheless, the differencesshowed are acceptable compared to those achieved by considering different stent initial positions. Regarding computationalcosts, simulations involving 1D stent features are the only ones feasible in clinical context.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To evaluate subconjunctival mitomycin C (MMC) injection efficacy and safety in patients with failing glaucoma non-penetrating filtering blebs. METHODS: Twenty-eight eyes were consecutively recruited for this study. Only one eye for each patient was randomly selected. All the recruited patients had glaucoma and uncontrolled intraocular pressure after a non-penetrating filtering glaucoma surgery and/or a pathological aspect of the filtering bleb (i.e., vascularized and/or encysted). One or more MMC injections were performed under the conjunctiva closed to the bleb to improve filtration. Local effects and complications of subconjunctival MMC injections were analyzed. RESULTS: Out of the 28 patients, 21 (75%) had MMC also applied intraoperatively. The mean postoperative IOP before MMC injections was 17 +/- 6.6 mmHg. The final IOP after MMC injections was 13.9 +/- 2.9 mmHg after a mean follow-up of 6 months. A total of 67 subconjunctival MMC injections were performed with a mean of 2.9 (ranging from 1 to 5) injections per patient. The only complication found to be possibly related to MMC injections was two cases of corneal Dellen. CONCLUSION: From these preliminary results, subconjunctival MMC injections in selected cases appear to be not only safe but also effective in promoting further the postoperative IOP drop.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: Performing total knee replacement, accurate alignment and neutral rotation of the femoral component are widely believed to be crucial for the ultimate success. Contrary to absolute bone referenced alignment, using a ligament balancing technique does not automatically rotate the femoral component parallel to the transepicondylar axis. In this context we established the hypothesis that rotational alignment of the femoral component parallel to the transepicondylar axis (0° ± 3°) results in better outcome than alignment outside of this range. METHODS: We analysed 204 primary cemented mobile bearing total knee replacements five years postoperatively. Femoral component rotation was measured on axial radiographs using the condylar twist angle (CTA). Knee society score, range of motion as well as subjective rating documented outcome. RESULTS: In 96 knees the femoral component rotation was within the range 0 ± 3° (neutral rotation group), and in 108 knees the five-year postoperative rotational alignment of the femoral component was outside of this range (outlier group). Postoperative CTA showed a mean of 2.8° (±3.4°) internal rotation (IR) with a range between 6° external rotation (ER) and 15° IR (CI 95). No difference with regard to subjective and objective outcome could be detected. CONCLUSION: The present work shows that there is a large given natural variability in optimal rotational orientation, in this study between 6° ER and 15° IR, with numerous co-factors determining correct positioning of the femoral component. Further studies substantiating pre- and postoperative determinants are required to complete the understanding of resulting biomechanics in primary TKA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Reversed shoulder arthroplasty is an accepted treatment for glenohumeral arthritis associated to rotator cuff deficiency. For most reversed shoulder prostheses, the baseplate of the glenoid component is uncemented and its primary stability is provided by a central peg and peripheral screws. Because of the importance of the primary stability for a good osteo-integration of the baseplate, the optimal fixation of the screws is crucial. In particular, the amplitude of the tightening force of the nonlocking screws is clearly associated to this stability. Since this force is unknown, it is currently not accounted for in experimental or numerical analyses. Thus, the primary goal of this work is to measure this tightening force experimentally. In addition, the tightening torque was also measured, to estimate an optimal surgical value. METHODS: An experimental setup with an instrumented baseplate was developed to measure simultaneously the tightening force, tightening torque and screwing angle, of the nonlocking screws of the Aquealis reversed prosthesis. In addition, the amount of bone volume around each screw was measured with a micro-CT. Measurements were performed on 6 human cadaveric scapulae. FINDINGS: A statistically correlated relationship (p<0.05, R=0.83) was obtained between the maximal tightening force and the bone volume. The relationship between the tightening torque and the bone volume was not statistically significant. INTERPRETATION: The experimental relationship presented in this paper can be used in numerical analyses to improve the baseplate fixation in the glenoid bone.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Résumé : Ce travail porte sur l'étude rétrospective d'une série de jeunes patients opérés de glaucomes pédiatriques. Le but est d'évaluer le résultat au long cours d'une intervention chirurgicale combinant une sclérectomie profonde et une trabéculectomie (sclérectomie profonde pénétrante). Durant la période de mars 1997 à octobre 2006, 28 patients on été suivis pour évaluer le résultat de cette chirurgie effectuées sur 35 yeux. Un examen ophtalmologique complet a été pratiqué avant la chirurgie, 1 et 7 jours, puis 1, 2, 3, 4, 6, 9, 12 mois, enfin tous les 6 mois après l'opération. Les critères d'évaluation du résultat postopératoire sont : les changements de pression intraoculaire, le traitement antiglaucomateux adjuvant, le taux de complication, le nombre de reprises chirurgicales,- l'erreur de réfraction, la meilleure acuité visuelle corrigée, l'état et le diamètre de la cornée. L'âge moyen est de 3.6 ± 4.5 ans et le suivi moyen de 3.6 ± 2.9 ans. La pression intraoculaire préopératoire de 31.9 ± 11.5 mmHg baisse de 58.3% (p<0.005) à la fin du suivi. Sur les 14 patients dont l'acuité visuelle a pu être mesurée, 8 (57.1 %) ont une acuité égale ou supérieure à 5/10e, 3 (21.4%) une acuité de 2/10e après intervention. Le taux de succès cumulatif complet à 9 ans est de 52.3%, le succès relatif 70.6%. Les complications menaçant la vision (8.6%) ont été plus fréquentes dans les cas de glaucome réfractaire. Pour conclure la sclérectomie profonde combinée à une trabéculectomie est une technique chirurgicale développée afin de contrôler la pression intraoculaire dans les cas de glaucomes congénitaux, juvéniles et secondaires. Les résultats intermédiaires sont encourageants et prometteurs. Les cas préalablement opérés avant cette nouvelle technique ont cependant un pronostic moins favorable. Le nombre de complications menaçant la vision est essentiellement lié à la sévérité du glaucome et au nombre d'interventions préalables. Abstract : Purpose : To evaluate the outcomes of combined deep sclerectomy and trabeculectomy (penetrating deep sclerectomy) in pediatric glaucoma. Design : Retrospective, non-consecutive, non-comparative, interventional case series. Participants : Children suffering from pediatric glaucoma who underwent surgery between March 1997 and October 2006 were included in this study. Methods : A primary combined deep sclerectomy and trabeculectomy was performed in 35 eyes of 28 patients. Complete examinations were performed before surgery, postoperatively at 1 and 7 days, at 1, 2, 3, 4, 6, 9, 12 months and then every 6 months after surgery. Main Outcome Measures : Surgical outcome was assessed in terms of intraocular pressure (IOP) change, additional glaucoma medication, complication rate, need for surgical revision, as well as refractive errors, best corrected visual acuity (BCVA), and corneal clarity and diameters. Results : The mean age before surgery was 3.6 ± 4.5 years, and the mean follow-up was 3.5 ± 2.9 years. The mean preoperative IOP was 31.9 ± 11.5 mmHg. At the end of follow-up, the mean IOP decreased by 58.3% (p<0.005), and from 14 patients with available BCVA 8 patients (57.1 %) achieved. 0.5 (20/40) or better, 3 (21.4%) 0.2 (20/100), and 2 (14.3%) 0.1 (20/200) in their better eye. The mean refractive error (spherical equivalent) at final follow-up visits was +0.83 ± 5.4. Six patients (43%) were affected by myopia. The complete and qualified success rates, based on a cumulative survival curve, after- 9 years were 52.3% and 70.6%, respectively (p<0.05). Sight threatening complications were more common (8.6%) in refractory glaucomas. Conclusions : Combined deep sclerectomy and trabeculectomy is a surgical technique developed to control IOP in congenital, secondary and juvenile glaucomas. The intermediate results are satisfactory and promising. Previous classic glaucoma surgeries performed before this new technique had less favourable results. The number of sight threatening complications is related to the severity of glaucoma and number of previous surgeries.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In a biophysical approach to the study of swimming performance (blending biomechanics and bioenergetics), inter-limb coordination is typically considered and analysed to improve propulsion and propelling efficiency. In this approach, 'opposition' or 'continuous' patterns of inter-limb coordination, where continuity between propulsive actions occurs, are promoted in the acquisition of expertise. Indeed a 'continuous' pattern theoretically minimizes intra-cyclic speed variations of the centre of mass. Consequently, it may also minimize the energy cost of locomotion. However, in skilled swimming performance there is a need to strike a delicate balance between inter-limb coordination pattern stability and variability, suggesting the absence of an 'ideal' pattern of coordination toward which all swimmers must converge or seek to imitate. Instead, an ecological dynamics framework advocates that there is an intertwined relationship between the specific intentions, perceptions and actions of individual swimmers, which constrains this relationship between coordination pattern stability and variability. This perspective explains how behaviours emerge from a set of interacting constraints, which each swimmer has to satisfy in order to achieve specific task performance goals and produce particular task outcomes. This overview updates understanding on inter-limb coordination in swimming to analyse the relationship between coordination variability and stability in relation to interacting constraints (related to task, environment and organism) that swimmers may encounter during training and performance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: Aerodynamic drag plays an important role in performance for athletes practicing sports that involve high-velocity motions. In giant slalom, the skier is continuously changing his/her body posture, and this affects the energy dissipated in aerodynamic drag. It is therefore important to quantify this energy to understand the dynamic behavior of the skier. The aims of this study were to model the aerodynamic drag of alpine skiers in giant slalom simulated conditions and to apply these models in a field experiment to estimate energy dissipated through aerodynamic drag. METHODS: The aerodynamic characteristics of 15 recreational male and female skiers were measured in a wind tunnel while holding nine different skiing-specific postures. The drag and the frontal area were recorded simultaneously for each posture. Four generalized and two individualized models of the drag coefficient were built, using different sets of parameters. These models were subsequently applied in a field study designed to compare the aerodynamic energy losses between a dynamic and a compact skiing technique. RESULTS: The generalized models estimated aerodynamic drag with an accuracy of between 11.00% and 14.28%, and the individualized models estimated aerodynamic drag with an accuracy between 4.52% and 5.30%. The individualized model used for the field study showed that using a dynamic technique led to 10% more aerodynamic drag energy loss than using a compact technique. DISCUSSION: The individualized models were capable of discriminating different techniques performed by advanced skiers and seemed more accurate than the generalized models. The models presented here offer a simple yet accurate method to estimate the aerodynamic drag acting upon alpine skiers while rapidly moving through the range of positions typical to turning technique.