Propolis obtained from honeybee hives has been widely used in medicine, cosmetics, and industry due to its versatile biological activities (antioxidant, antimicrobial, fungicidal, antiviral, antiulcer, immunostimulating, and cytostatic). These activities are mainly attributed to the presence of flavonoids in propolis, which points out the interest in quantifying these constituents in propolis preparations, as well as validation of analytical methodologies. High-performance liquid chromatography (HPLC) methods have been reported to quantify isolated flavonoids or these compounds in complex biological matrices, such as herbal raw materials and extractive preparations. An efficient, precise, and reliable method was developed for quantification of propolis extractive solution using HPLC with UV detection. The chromatograms were obtained from various gradient elution systems (GES) tested in order to establish the ideal conditions for the analysis of propolis extractive solution, using methanol and water: acetonitrile (97.5 : 2.5, v/v) as mobile phase. Gradient reversed phase chromatography was performed using a stainless steel column (250 x 4.6 mm i.d., 5 mum) filled with Chromsep RP 18 (Varian), column temperature at 30.0 +/- 0.1degreesC and detection at 310 nm. The main validation parameters of the method were also determined. The method showed linearity for chrysin in the range 0.24-2.4 mug mL(-1) with good correlation coefficients (0.9975). Precision and accuracy were determined. The obtained results demonstrate the efficiency of the proposed method. The analytical procedure is reliable and offers advantages in terms of speed and cost of reagents.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A sensitive, accurate, reliable and easy method was developed for the quantification of oxamniquine in capsules using high-performance liquid chromatography (HPLC) with UV detection. This technique provided conditions for the separation of the active ingredient from the dosage form by extraction in methanol. Isocratic reversed phase chromatography was performed using methanol, water, and triethanolamine (60:40:0.099, v/v/w) (System C) or methanol, acetonitrile, water and formic acid (40:30:30:0.083, v/v/w) (System D) as mobile phase, a stainless steel column (125 x 4 mm i.d., 5 mum) filled with LiChrospher 100 RP-18 (Merck), column temperature of 28 +/- 2 degreesC and detection at 260 nm. The calibration curves were linear over a wide concentration range (1.0-20.0 mug ml(-1) of oxamniquine) to the Systems C and D with good correlation factor (0.9990 and 0.9982, respectively). The average content obtained were 100.1 +/- 1.5% (System C) and 102.4 +/- 0.8% (System D). The presence of lactose, starch, magnesium stearate and sodium laurylsulphate did not interfere in the results of the analysis. The above findings showed the proposed method to be both simple and added advantage of allowing for fast analysis. (C) 2001 Elsevier B.V. B.V. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The carotenoid composition of Brazilian Valencia orange juice was determined by open column chromatography (OCC) and high-performance liquid chromatography. Carotenoid pigments were extracted using acetone and saponified using 10% methanolic potassium hydroxide. Sixteen pigments were isolated by OCC and identified as alpha-carotene, zeta-carotene, beta-carotene, alpha-cryptoxanthin, beta-cryptoxanthin, lutein-5,6-epoxide, violaxanthin, lutein, antheraxanthin, zeaxanthin, luteoxanthin A, luteoxanthin B, mutatoxanthin A, mutatoxanthin B, auroxanthin B and trollichrome B. Thirteen carotenoid pigments were separated using a ternary gradient (acetonitrile-methanol-ethyl acetate) elution on a C-18 reversed-phase column. Among these, violaxanthin, lutein, zeaxanthin, beta-cryptoxanthin, zeta-carotene, alpha-carotene, and beta-carotene were quantified. The total carotenoid content was 12 +/- 6.7 mg/1, and the major carotenoids were lutein (23%), beta-cryptoxanthin (21%), and zeaxanthin (20%). 2005 Elsevier Ltd. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A practical set of HPLC methods was developed for the separation and determination of the eggplant steroidal glycoalkaloids, solanine, chaconine, solasonine, solamargine, and their aglycones, solasodine and solanidine. A gradient method was initially developed, but proved to be neither robust nor practical. Three separate isocratic methods using acetonitrile and ammonium dihydrogen phosphate were developed and shown to be more repeatable, less subject to fluctuations in mobile phase composition, and less time consuming. The effect of adjusting buffer pH, column temperature, and buffer type (triethylammonium phosphate vs. ammonium dihydrogen phosphate) were evaluated. It was also discovered that, by addition of 10% methanol to the acetonitrile portion of the mobile phase, more control over the separations was possible. The use of methanol as a mobile phase entrainer greatly improved separations in some cases and its effectiveness was also dependent upon column temperature. Assessments of the method recovery, limit of detection, and limit of quantitation were made using extracts from S. melongena and S. linnaeanum.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A high performance liquid chromatography (HPLC) method for extraction and determination of pesticides from raw milk was developed. The method involves direct injection of raw milk samples on a bovine serum albumin-dimethyl-octyl-silica gel (BSA-Si-Cs) column. The mobile phase 0.05 mol.L-1 phosphate buffer pH6.0 in acetonitrile (70:30 v/v) was employed for extraction and separation of bendiocarb, methylparathion, pentachlorophenol, and methomyl pesticides. The method shows good results of recovery in the pesticides studied, higher than 99.6%.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Absorbance detection in capillary electrophoresis (CE), offers an excellent mass sensitivity, but poor concentration detection limits owing to very small injection volumes (normally I to 10 nL). This aspect can be a limiting factor in the applicability of CE/UV to detect species at trace levels, particularly pesticide residues. In the present work, the optical path length of an on-column detection cell was increased through a proper connection of the column (75 mu m i.d.) to a capillary detection cell of 180 mu m optical path length in order to improve detectability. It is shown that the cell with an extended optical path length results in a significant gain in terms of signal to noise ratio. The effect of the increase in the optical path length has been evaluated for six pesticides, namely, carbendazim, thiabendazole, imazalil, procymidone triadimefon, and prochloraz. The resulting optical enhancement of the detection cell provided detection limits of ca. 0.3 mu g/mL for the studied compounds, thus enabling the residue analysis by CE/UV.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This method has been developed for extraction and determination of phenol in a urine sample by high performance liquid chromatography.After acid hydrolysis, the free phenol was extracted with isoamyl alcohol solvent, followed by back extraction with 0.5 mol.L-1 sodium hydroxide solution and analyzed by an isocratic HPLC Varian System, equipped with reverse-phase column (MicroPak-C-18). The mobile phase was acetonitrile in 0.01 mol.L-1 hydrochloric acid solution, (20:80 v/v), and at a now-rate of 1.0 mL.min-1. The chromatogram was monitored at 220 nm in room temperature. The identification was based on retention time and the quantification was performed by automatic peak-area determination, corrected for the external standards method.The recovery was higher than 99.5 % for phenol and reproducibility of method was shown to be 2.3% standard deviation and 5.6% coefficient of variance (n=20). The limit detection was 0.05 mgL(-1) and a range of 0.05 to 20.0 mgL(-1) of phenol for linearity.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In this study, we worked with the validation of a methodology for analysis of bioactive amines in shrimp, considering it to be one of the main products of the northriograndense trade balance, maintaining the state of Rio Grande do Norte topped the list of Brazilian exports of this product the last decade. The sector of the Brazilian shrimp works exclusively with gray shrimp Litopenaeus Vannamei since the late 1990s. This study used liquid chromatography with conductimetric detector, using as the mobile phase methylsulfonic 3 mM acid (MSA) with gradient and phase C18 column with reverse the development of methodology for the analysis of bioactive amines in shrimp. In the sample preparation was used as 5% trichloroacetic acid (TCA) extraction solution. Validation analysis of biotativas amines (putrescine - PUT, histamine - HIST, agmatine - AGM, spermidine - EPD and spermine - EPN) in shrimp, the linear working range was 0.1 to 2.0 mg L-1 to was sensitive, homoscedastic, in effect, selective, accurate and precise array. Thus, considered feasible for these determinations bioactive amines in this array. Determined the concentration of these amines in fresh shrimps (AGM = 0.61 ± 0.05 mg kg- 1 EPD = 2.57 ± 0.14 mg kg-1 and EPN = 1.79 ± 0.11 mg kg-1), and freezing weather predetermined in cooked shrimp (AGM = 6.28 ± 0.18 mg kg-1, EPD = 12.72 ± 0.02 mg kg- 1 and EPN = 22.30 ± 0.60 mg kg-1), the shrimp with twenty-four hour stay at room temperature (PUT = 879.52 ± 28.12 mg kg-1, AGM = 848.13 ± 19.40 mg kg-1, ESPD = 13.59 ± 0.97 mg kg-1 and ESPN = 18.47 + 1.57 mg kg-1). In shrimp subjected to freezing for a week, two weeks, three weeks and four weeks, the results showed that there is an increase in the content of agmatine (7.31 ± 0.21 mg kg-1) while in spermine ( 1.22 ± 0.14 mg kg-1) and spermidine (below limit of quantification) there was a decrease in the freeze time, while there is a decrease in the level of spermidine not reaching detectad. The putrescine was only found in shrimp that remained for 24 hours at room temperature and histamine was not found in any of the samples

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The pharmacokinetics of enrofloxacin (ENRO), a fluoroquinolone antimicrobial agent, was studied in male broiler chickens (Cobb) after single oral administration of 10 mg of ENRO/kg b.w. A high-performance liquid chromatography-photodiode array detector (DAD) (HPLC-DAD) method was developed and validated and used for quantitation of ENRO and its major metabolite ciprofloxacin in plasma. The HPLC analyses were carried out using a cationic-octadecyl mixed column and 0.05 mol/L phosphate buffer (pH 2.5)/acetonitrile as mobile phase. The sample preparation of plasma consisted of the precipitation of proteins followed by solid phase extraction on cationic-octadecyl mixed cartridges. The method was validated considering linear range, linearity, selectivity, sensitivity, limit of detection (LOD), limit of quantitation (LOQ), intra- and inter-day precisions and accuracy. The LOD and LOQ for both fluoroquinolones were 60 and 200 ng/mL for plasma. The plasma concentration vs. time graph was characteristic of a two-compartment open model. The maximal plasma concentration of 1.5 +/- 0.2 mg/mL was achieved at 9 +/- 2 h. The elimination half-life and the mean residence time of ENRO were 1.5 +/- 0.2 and 15.64 h, respectively. The area under the concentration-time curve was calculated as 35 +/- 4 mg(.)h/mL.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Several factors render carotenoid determination inherently difficult. Thus, in spite of advances in analytical instrumentation, discrepancies in quantitative results on carotenoids can be encountered in the international literature. A good part of the errors comes from the pre-chromatographic steps such as sampling scheme that does not yield samples representative of the food lots under investigation; sample preparation which does not maintain representativity and guarantee homogeneity of the analytical sample; incomplete extraction; physical losses of carotenoids during the various steps, especially during partition or washing and by adsorption to glass walls of containers; isomerization and oxidation of carotenoids during analysis. on the otherhand, although currently considered the method of choice for carotenoids, high performance liquid chromatography (HPLC) is subject to various sources of errors, such as: incompatibility of the injection solvent and the mobile phase, resulting in distorted or split peaks; erroneous identification; unavailability, impurity and instability of carotenoid standards; quantification of highly overlapping peaks; low recovery from the HPLC column; errors in the preparation of standard solutions and in the calibration procedure; calculation errors. Illustrations of the possible errors in the quantification of carotenoids by HPLC are presented.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A reversed phase liquid chromatographic method was developed for the simultaneous determination of carboxylic acids and phenolics in white wines. The samples, diluted, were injected onto a Spherisorb ODS-2 column with a gradient of sulfuric acid (pH 2.5)/methanol as mobile phase. A diode array detector was used which was set at 210nm for carboxylic acids and altered to 278nm, during the run, far phenolics and sorbic acid. The identification of compounds was based on retention time, co-chromatography and UV spectrum. Some clean-up methods (sep-pak C-18 and an ion exchange column) mere tested and did not improve the results.The analysis was simple, with no sample preparation. Application of this method was illustrated by analyses of Brazilian Welchriesling wines.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)