893 resultados para Collectors and collecting


Relevância:

30.00% 30.00%

Publicador:

Resumo:

A sealed space between absorber and cover glass makes it possible reducing the influence of humidity condensate and dust at the same time as the enclosed space can be filled with a suitable gas for lowering the losses. This paper is about the size of the losses in these collectors. A calculating model of a gas-filled flat plate solar collector was built in Matlab with standard heat transfer formulas. It showed that the total loss can be reduced up to 20% when changing to an inert gas. It is also possible using a much shorter distance and still achieve low losses at the same time as the mechanical stresses in the material is reduce.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The demand for cooling and air-conditioning of building is increasingly ever growing. This increase is mostly due to population and economic growth in developing countries, and also desire for a higher quality of thermal comfort. Increase in the use of conventional cooling systems results in larger carbon footprint and more greenhouse gases considering their higher electricity consumption, and it occasionally creates peaks in electricity demand from power supply grid. Solar energy as a renewable energy source is an alternative to drive the cooling machines since the cooling load is generally high when solar radiation is high. This thesis examines the performance of PV/T solar collector manufactured by Solarus company in a solar cooling system for an office building in Dubai, New Delhi, Los Angeles and Cape Town. The study is carried out by analyzing climate data and the requirements for thermal comfort in office buildings. Cooling systems strongly depend on weather conditions and local climate. Cooling load of buildings depend on many parameters such as ambient temperature, indoor comfort temperature, solar gain to the building and internal gains including; number of occupant and electrical devices. The simulations were carried out by selecting a suitable thermally driven chiller and modeling it with PV/T solar collector in Polysun software. Fractional primary energy saving and solar fraction were introduced as key figures of the project to evaluate the performance of cooling system. Several parametric studies and simulations were determined according to PV/T aperture area and hot water storage tank volume. The fractional primary energy saving analysis revealed that thermally driven chillers, particularly adsorption chillers are not suitable to be utilizing in small size of solar cooling systems in hot and tropic climates such as Dubai and New Delhi. Adsorption chillers require more thermal energy to meet the cooling load in hot and dry climates. The adsorption chillers operate in their full capacity and in higher coefficient of performance when they run in a moderate climate since they can properly reject the exhaust heat. The simulation results also indicated that PV/T solar collector have higher efficiency in warmer climates, however it requires a larger size of PV/T collectors to supply the thermally driven chillers for providing cooling in hot climates. Therefore using an electrical chiller as backup gives much better results in terms of primary energy savings, since PV/T electrical production also can be used for backup electrical chiller in a net metering mechanism.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Hybrid Photovoltaic Thermal (PVT) collectors are an emerging technology that combines PV and solar thermal systems in a single solar collector producing heat and electricity simultaneously. The focus of this thesis work is to evaluate the performance of unglazed open loop PVT air system integrated on a garage roof in Borlänge. As it is thought to have a significant potential for preheating ventilation of the building and improving the PV modules electrical efficiency. The performance evaluation is important to optimize the cooling strategy of the collector in order to enhance its electrical efficiency and maximize the production of thermal energy. The evaluation process involves monitoring the electrical and thermal energies for a certain period of time and investigating the cooling effect on the performance through controlling the air mass flow provided by a variable speed fan connected to the collector by an air distribution duct. The distribution duct transfers the heated outlet air from the collector to inside the building. The PVT air collector consists of 34 Solibro CIGS type PV modules (115 Wp for each module) which are roof integrated and have replaced the traditional roof material. The collector is oriented toward the south-west with a tilt of 29 ᵒ. The collector consists of 17 parallel air ducts formed between the PV modules and the insulated roof surface. Each air duct has a depth of 0.05 m, length of 2.38 m and width of 2.38 m. The air ducts are connected to each other through holes. The monitoring system is based on using T-type thermocouples to measure the relevant temperatures, air sensor to measure the air mass flow. These parameters are needed to calculate the thermal energy. The monitoring system contains also voltage dividers to measure the PV modules voltage and shunt resistance to measure the PV current, and AC energy meters which are needed to calculate the produced electrical energy. All signals recorded from the thermocouples, voltage dividers and shunt resistances are connected to data loggers. The strategy of cooling in this work was based on switching the fan on, only when the difference between the air duct temperature (under the middle of top of PV column) and the room temperature becomes higher than 5 °C. This strategy was effective in term of avoiding high electrical consumption by the fan, and it is recommended for further development. The temperature difference of 5 °C is the minimum value to compensate the heat losses in the collecting duct and distribution duct. The PVT air collector has an area of (Ac=32 m2), and air mass flow of 0.002 kg/s m2. The nominal output power of the collector is 4 kWppv (34 CIGS modules with 115 Wppvfor each module). The collector produces thermal output energy of 6.88 kWth/day (0.21 kWth/m2 day) and an electrical output energy of 13.46 kWhel/day (0.42 kWhel/m2 day) with cooling case. The PVT air collector has a daily thermal energy yield of 1.72 kWhth/kWppv, and a daily PV electrical energy yield of 3.36 kWhel /kWppv. The fan energy requirement in this case was 0.18 kWh/day which is very small compared to the electrical energy generated by the PV collector. The obtained thermal efficiency was 8 % which is small compared to the results reported in literature for PVT air collectors. The small thermal efficiency was due to small operating air mass flow. Therefore, the study suggests increasing the air mass flow by a factor of 25. The electrical efficiency was fluctuating around 14 %, which is higher than the theoretical efficiency of the PV modules, and this discrepancy was due to the poor method of recording the solar irradiance in the location. Due to shading effect, it was better to use more than one pyranometer.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Grammar has always been an important part of language learning. Based on various theories, such as the universal grammar theory (Chomsky, 1959) and, the input theory (Krashen, 1970), the explicit and implicit teaching methods have been developed. Research shows that both methods may have some benefits and disadvantages. The attitude towards English grammar teaching methods in schools has also changed and nowadays grammar teaching methods and learning strategies, as a part of language mastery, are one of the discussion topics among linguists. This study focuses on teacher and learner experiences and beliefs about teaching English grammar and difficulties learners may face. The aim of the study is to conduct a literature review and to find out what scientific knowledge exists concerning the previously named topics. Along with this, the relevant steering documents are investigated focusing on grammar teaching at Swedish upper secondary schools. The universal grammar theory of Chomsky as well as Krashen’s input hypotheses provide the theoretical background for the current study. The study has been conducted applying qualitative and quantitative methods. The systematic search in four databases LIBRIS, ERIK, LLBA and Google Scholar were used for collecting relevant publications. The result shows that scientists’ publications name different grammar areas that are perceived as problematic for learners all over the world. The most common explanation of these difficulties is the influence of learner L1. Research presents teachers’ and learners’ beliefs to the benefits of grammar teaching methods. An effective combination of teaching methods needs to be done to fit learners’ expectations and individual needs. Together, they will contribute to the achieving of higher language proficiency levels and, therefore, they can be successfully applied at Swedish upper secondary schools.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper studies the influence of hydraulics and control of thermal storage in systems combined with solar thermal and heat pump for the production of warm water and space heating in dwellings. A reference air source heat pump system with flat plate collectors connected to a combistore was defined and modeled together with the IEA SHC Task 44 / HPP Annex 38 (T44A38) “Solar and Heat Pump Systems” boundary conditions of Strasbourg climate and SFH45 building. Three and four pipe connections as well as use of internal and external heat exchangers for DHW preparation were investigated as well as sensor height for charging of the DHW zone in the store. The temperature in this zone was varied to ensure the same DHW comfort was achieved in all cases. The results show that the four pipe connection results in 9% improvement in SPF compared to three pipe and that the external heat exchanger for DHW preparation leads to a 2% improvement compared to the reference case. Additionally the sensor height for charging the DHW zone of the store should not be too low, otherwise system performance is adversely affected

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Vocational teachers in Swedish upper secondary schools are a heterogeneous category of teachers, connected to different types of trade. These teachers represent a broad set of trade skills varying in content and character. In their teacher role, they continue to wear the clothes, speak the language, share the culture and remain mentally in their former professions. Still, it is central that they keep up this contact to be able to school the pupils into the environment of the trade in question, but also to help them to understand what skills a profession demands. However, the individual teacher also has to distance himself from the negative elements in the culture of the profession: patterns and habits that, for various reasons, have to be broken or changed. This paper draws attention to the ways in which a group of vocational teachers, who were participants in a project that aimed to train unauthorized vocational teachers, expressed their ambitions to prepare the pupils for a future professional career. When collecting information, we used the degree dissertations they produced and discussed in seminars, and informal dialogues. The result shows that it is important that the instruction location resembles a real working site as far as possible. These places are more or less realistic copies of a garage, a restaurant kitchen, a hairdressing salon, and so on, in order to give the pupils a realistic setting for instruction. However, the fact that these simulated workplaces lack the necessary support functions that exist in a company creates problems, problems which make a lot of extra work for the teachers. Vocational teachers also have to instruct the pupil in the experienced practitioner’s professional skills and working situation, but the pupil herself/himself must learn the job by doing it in practice. Some vocational upper secondary programs lack relevant course literature and the businesses give little support. This also makes extra work for the teachers. Moreover, the distance between the vocational programs and the trainee jobs was experienced as being difficult to overcome. One reason seems to be differences between businesses and differing preconditions between small and big companies’ abilities to take care of these pupils. The upper secondary school vocational programs also play a role in cementing existing gender roles, as well as perpetuating class-related patterns on the labour market.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Vocational teachers in Swedish upper secondary schools are a heterogeneous category of teachers, connected to different types of trade. These teachers represent a broad set of trade skills varying in content and character. In their teacher role, they continue to wear the clothes, speak the language, share the culture and remain mentally in their former professions. Still, it is central that they keep up this contact to be able to school the pupils into the environment of the trade in question, but also to help them to understand what skills a profession demands. However, the individual teacher also has to distance himself from the negative elements in the culture of the profession: patterns and habits that, for various reasons, have to be broken or changed. This paper draws attention to the ways in which a group of vocational teachers, who were participants in a project that aimed to train unauthorized vocational teachers, expressed their ambitions to prepare the pupils for a future professional career. When collecting information, we used the degree dissertations they produced and discussed in seminars, and informal dialogues. The result shows that it is important that the instruction location resembles a real working site as far as possible. These places are more or less realistic copies of a garage, a restaurant kitchen, a hairdressing salon, and so on, in order to give the pupils a realistic setting for instruction. However, the fact that these simulated workplaces lack the necessary support functions that exist in a company creates problems, problems which make a lot of extra work for the teachers. Vocational teachers also have to instruct the pupil in the experienced practitioner’s professional skills and working situation, but the pupil herself/himself must learn the job by doing it in practice. Some vocational upper secondary programs lack relevant course literature and the businesses give little support. This also makes extra work for the teachers. Moreover, the distance between the vocational programs and the trainee jobs was experienced as being difficult to overcome. One reason seems to be differences between businesses and differing preconditions between small and big companies’ abilities to take care of these pupils. The upper secondary school vocational programs also play a role in cementing existing gender roles, as well as perpetuating class-related patterns on the labour market.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work is an ethnographic research with collectors women of Mangaba in the village of Ponta Negra in Natal - RN. This Women also known as Mangabeira's women reproduce a practice learned with their ancestors, collecting this fruit in the coastal tablelands forests and latter commercializing it in the local markets. This research uses the methodology of oral history and visual anthropology with presentation of collected images on board. It is intended to emphasize the botanical and environmental aspects of the Mangabeira plant, its ecosystem, territorial, economic and historical aspects of it, also the knowledge of this extractive practice of our immaterial culture.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Settlement rate may not reflect larval supply to coastal waters in different marine invertebrates and demersal fishes. The importance of near-shore oceanography and behaviour of late larval stages may be underestimated. The present study conducted neustonic sampling over station grids and along full-length transects at two embayments in south-eastern Brazil to (1) compare diurnal and nocturnal occurrence of most frequent decapod stages to assess their vertical movements, (2) describe the formation of larval patches and (3) measure competence of crab megalopae according to their distance to recruitment grounds. Several shrimp species apparently undergo a diel vertical migration, swimming crab megalopae showed no vertical movements and megalopae of the intertidal crab Pachygrapsus transversus revealed a reversed vertical migration. During the day, crab megalopae aggregated in convergence zones just below surface slicks. These larvae consisted of advanced, pre-moult stages, at both mid-bay and near-shore patches. Competence, measured as the time to metamorphosis in captivity, was similar between larval patches within each taxon. Yet, subtidal portunids moulted faster to juveniles than intertidal grapsids, possibly because they were closer to settlement grounds. Megalopae of Pachygrapsus from benthic collectors moulted faster than those from bay areas. These results suggest that alternative vertical migration patterns of late megalopae favour onshore transport, and actual competence takes place very close to suitable substrates, where larvae may remain for days before settlement. Lack of correlation between larval supply and settlement for Pachygrapsus suggests that biological processes, besides onshore transport, may play an important role in determining settlement success of coastal crabs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Settlement is a critical process in the life history of crabs, and thus affecting the abundance, distribution and structure of estuarine communities. The spatial pattern of settlement of megalopae of the shore crab Carcinus maenas along a longitudinal estuarine gradient (Mira River Estuary, Portugal) was examined, as well as its effects on the juvenile population. To measure megalopal settlement, four replicate collectors were deployed in six equally spaced stations along the estuarine axis. Juveniles were collected on the same locations with a quadrat randomly deployed on the substrate. To assess fine-scale megalopal settlement within a curved region of the estuary, replicate collectors were deployed on both margins along Moinho da Asneira curve. Megalopae settled differently along the six longitudinal points, with a tendency to attenuate their settlement upstream. Within the curved region, megalopae preferentially settled on the left margin collectors, probably due to the weaker velocity speeds felt on this margin. Concerning the overall juvenile density, there were significant differences among the stations distributed along the estuary, but they did no reflect a longitudinal dispersion attenuation pattern. Size-frequency distribution of the juvenile population showed that the average size is higher on the left margin. Recruits (carapace length between 1.0 mm and 3.4 mm) were more abundant on the upstream stations. Density of early juveniles (3.4 mm-6.5 mm) and juveniles (6.5 mm-10 mm) was more stable throughout the estuary axis than that of recruits. This distribution pattern may result from tidal excursion processes or mechanisms to avoid biotic interactions, such as predation and competition. (c) 2006 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aimed to establish patterns of dynamics of litter and redistribution of rainfall of Caatinga vegetation. Sampling was done monthly for twenty three months in four areas: degraded, successional primary stage, secondary stage and late stage. We installed 72 collectors of 1.0 mx 1.0 m, with nylon fabric background in three areas. Litter deposited was fractionated into leaves, twigs, reproductive structures and miscellaneous, dried and weighed. To assess the stock of accumulated litter we used metal frame with dimensions of 0.5 mx 0.5 m, thrown randomly and collected monthly, taken to the laboratory for oven drying and weighed. To evaluate the decomposition, 40g of litter were placed in nylon bags (litterbags) mesh 1 mm ², dimensions 20.0 x 20.0 cm, being distributed on the soil surface and removed monthly, cleaned, dried and weighed. To evaluate the contribution of rainfall we used interceptometers installed 1.0 m above the ground surface, distributed under the canopy of six species of the caatinga, which evaluated the stemflow through collecting system installed around the stems of these species. The deposition of litter in the primary stage was 2.631,26 kg ha-1; 3.144,89 kg ha-1 in the secondary stage; 3.144,89 kg ha-1 in the late stage. The fraction of leaves was the largest contributor to the formation of litter in three stages. The degraded area showed greater accumulation of litter and decomposition has been sluggish during the dry period. We conclude that occurred greater litterfall in later stages. The late successional stage showed faster decomposition of litter, the evidence that is a better use of litter in nutrient cycling processes and incorporation of organic matter to the soil. The time required to decompose 50 % of the litter in the later stages of succession was lower indicating greater speed of release and reuse of nutrients by the vegetation. The specie jurema preta with less leaf area and consists of leaflets, showed greater internal precipitation in rain events of greater magnitude. The stemflow was not influenced by DAP and basal area. The water lost by trapping represented the largest proportion of total rainfall in all species studied

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Agouti paca is both considered as a species vulnerable to extinction and recognised with the potential for domestication. In spite of this, its behaviour is poorly documented and captive breeding is mainly based on trial and error. The aim of the present research was to analyse whether different strategies of straw supply could affect the behaviour and welfare of pacas in captivity. The study was done with eight adult pacas grouped in four mated pairs, three of them with one offspring. Each group was housed separately in 10 m 2 pens and the straw collecting behaviour was recorded. The quantity of straw collected per day was measured to compare four different strategies for straw supply and nest removal, where: every day nest removal treatment (1R) = supplying 1 kg of straw every day (outside the burrow) and removing all straw from inside the burrow every day; every 3 days nest removal treatment (3R) = supplying 1 kg every day and removing after 3, 6, and 9 days; no nest removal treatment (9R) = supplying 1 kg every day and removing after 9 days; nest deprivation treatment (Dep) = supplying 1 kg every day except at days 3, 4, and 5 and removing after 3 and 9 days. Straw collecting was always performed after 17:30 h, with three behavioural acts being performed: mouthing, transporting, and depositing the straw into the artificial burrow. The straw collected per day mean of 1R was significantly higher than the means of other treatments. During the deprivation period of Dep, chips cut from the eucalyptus branches and a great quantity of fruits and manioc were found inside the burrows. The motivation to collect seemed to increase as a consequence of straw deprivation. By these we conclude that straw should be offered to pacas in captivity, giving them the opportunity to collect straw by themselves. Doing this we expect to promote an effective environmental enrichment for this species in captivity. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the petroleum industry, water is always present in the reservoir formation together with petroleum and natural gas and this fact provokes the production of water with petroleum, resulting in a great environmental impact. Several methods can be applied for treatment of oily waters, such as: gravitational vases, granulated media filtration systems, flotation process, centrifugation process and the use of hydrocyclones, which can also be used in a combined way. However, the flotation process has showed a great efficiency as compared with other methods, because these methods do not remove great part of the emulsified oil. In this work was investigated the use of surfactants derived from vegetable oils, OSS and OGS, as collectors, using the flotation process in a glass column with a porous plate filter in its base for the input of the gaseous steam. For this purpose, oil/water emulsions were prepared using mechanical stirring, with concentrations around 300 ppm. The air flow rate was set at 700 cm3/min and the porous plate filter used for the generation of the air bubbles has pore size varying from 16 to 40 Pm. The column operated at constant volume (1500mL). A new methodology has been developed to collect the samples, where, instead of collecting the water phase, it was collected the oil phase removed by the process in the top of the flotation column. It has been observed that it is necessary to find an optimum surfactant concentration to achieve enhanced removal efficiency. Being for OSS 1.275 mmol/L and for OGS 0.840 mmol/L, with removal efficiencies of 93% and 99%, respectively, using synthetic solutions. For the produced water, the removal in these concentrations was 75% for OSS and 65% for OGS. It is possible to remove oil from water in a flotation process using surfactants of high HLB, fact that is against the own definition of HLB (Hydrophile-Lipophile Balance). The interfacial tension is an important factor in the oil removal process using a flotation process, because it has direct interference in the coalescence of the oil drops. The spreading of the oil of the air bubble should be considered in the process, and for the optimum surfactant concentrations it reached a maximum value. The removal kinetics for the flotation process using surfactants in the optimum concentration has been adjusted according to a first order model, for synthetic water as for the produced water.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

When GNSS receivers capable of collecting dual-frequency data are available, it is possible to eliminate the first-order ionospheric effect in the data processing through the ionosphere-free linear combination. However, the second- and third-order ionospheric effects still remain. The first-, second- and third-order ionospheric effects are directly proportional to the total electron content (TEC), although the second- and third-order effects are influenced, respectively, by the geomagnetic field and the maximum electron density. In recent years, the international scientific community has given more attention to these kinds of effects and some works have shown that for high precision GNSS positioning these effects have to be taken into consideration. We present a software tool called RINEX_HO that was developed to correct GPS observables for second- and third-order ionosphere effects. RINEX_HO requires as input a RINEX observation file, then computes the second- and third-order ionospheric effects, and applies the corrections to the original GPS observables, creating a corrected RINEX file. The mathematical models implemented to compute these effects are presented, as well as the transformations involving the earth's magnetic field. The use of TEC from global ionospheric maps and TEC calculated from raw pseudorange measurements or pseudoranges smoothed by phase is also investigated.